logstash-input-snmp 0.1.0.beta4 → 0.1.0.beta5

Sign up to get free protection for your applications and to get access to all the features.
Files changed (309) hide show
  1. checksums.yaml +4 -4
  2. data/CHANGELOG.md +5 -0
  3. data/lib/logstash/inputs/snmp.rb +75 -12
  4. data/lib/logstash/inputs/snmp/base_client.rb +162 -0
  5. data/lib/logstash/inputs/snmp/client.rb +11 -109
  6. data/lib/logstash/inputs/snmp/clientv3.rb +139 -0
  7. data/lib/logstash/inputs/snmp/mib.rb +22 -20
  8. data/lib/mibs/ietf/ACCOUNTING-CONTROL-MIB.dic +1316 -0
  9. data/lib/mibs/ietf/ADSL-LINE-EXT-MIB.dic +1724 -0
  10. data/lib/mibs/ietf/ADSL-LINE-MIB.dic +7297 -0
  11. data/lib/mibs/ietf/ADSL-TC-MIB.dic +160 -0
  12. data/lib/mibs/ietf/ADSL2-LINE-MIB.dic +8663 -0
  13. data/lib/mibs/ietf/ADSL2-LINE-TC-MIB.dic +1462 -0
  14. data/lib/mibs/ietf/AGENTX-MIB.dic +817 -0
  15. data/lib/mibs/ietf/AGGREGATE-MIB.dic +708 -0
  16. data/lib/mibs/ietf/ALARM-MIB.dic +1734 -0
  17. data/lib/mibs/ietf/APM-MIB.dic +2870 -0
  18. data/lib/mibs/ietf/APPC-MIB.dic +8687 -0
  19. data/lib/mibs/ietf/APPLETALK-MIB.dic +4399 -0
  20. data/lib/mibs/ietf/APPLICATION-MIB.dic +3750 -0
  21. data/lib/mibs/ietf/APPN-DLUR-MIB.dic +972 -0
  22. data/lib/mibs/ietf/APPN-MIB.dic +9364 -0
  23. data/lib/mibs/ietf/APPN-TRAP-MIB.dic +664 -0
  24. data/lib/mibs/ietf/APS-MIB.dic +2430 -0
  25. data/lib/mibs/ietf/ARC-MIB.dic +552 -0
  26. data/lib/mibs/ietf/ATM-ACCOUNTING-INFORMATION-MIB.dic +816 -0
  27. data/lib/mibs/ietf/ATM-MIB.dic +4104 -0
  28. data/lib/mibs/ietf/ATM-TC-MIB.dic +914 -0
  29. data/lib/mibs/ietf/ATM2-MIB.dic +4715 -0
  30. data/lib/mibs/ietf/BFD-STD-MIB.dic +2367 -0
  31. data/lib/mibs/ietf/BFD-TC-STD-MIB.dic +202 -0
  32. data/lib/mibs/ietf/BGP4-MIB.dic +1931 -0
  33. data/lib/mibs/ietf/BLDG-HVAC-MIB.dic +812 -0
  34. data/lib/mibs/ietf/BRIDGE-MIB.dic +2257 -0
  35. data/lib/mibs/ietf/CAPWAP-BASE-MIB.dic +4128 -0
  36. data/lib/mibs/ietf/CAPWAP-DOT11-MIB.dic +482 -0
  37. data/lib/mibs/ietf/CHARACTER-MIB.dic +1140 -0
  38. data/lib/mibs/ietf/CIRCUIT-IF-MIB.dic +493 -0
  39. data/lib/mibs/ietf/CLNS-MIB.dic +1702 -0
  40. data/lib/mibs/ietf/COFFEE-POT-MIB.dic +282 -0
  41. data/lib/mibs/ietf/COPS-CLIENT-MIB.dic +1270 -0
  42. data/lib/mibs/ietf/DECNET-PHIV-MIB.dic +5837 -0
  43. data/lib/mibs/ietf/DIAL-CONTROL-MIB.dic +2139 -0
  44. data/lib/mibs/ietf/DIFFSERV-CONFIG-MIB.dic +378 -0
  45. data/lib/mibs/ietf/DIFFSERV-MIB.dic +5073 -0
  46. data/lib/mibs/ietf/DIRECTORY-SERVER-MIB.dic +1041 -0
  47. data/lib/mibs/ietf/DISMAN-EVENT-MIB.dic +3151 -0
  48. data/lib/mibs/ietf/DISMAN-EXPRESSION-MIB.dic +1716 -0
  49. data/lib/mibs/ietf/DISMAN-NSLOOKUP-MIB.dic +698 -0
  50. data/lib/mibs/ietf/DISMAN-PING-MIB.dic +2635 -0
  51. data/lib/mibs/ietf/DISMAN-SCHEDULE-MIB.dic +1744 -0
  52. data/lib/mibs/ietf/DISMAN-SCRIPT-MIB.dic +2820 -0
  53. data/lib/mibs/ietf/DISMAN-TRACEROUTE-MIB.dic +3239 -0
  54. data/lib/mibs/ietf/DLSW-MIB.dic +5635 -0
  55. data/lib/mibs/ietf/DNS-RESOLVER-MIB.dic +1765 -0
  56. data/lib/mibs/ietf/DNS-SERVER-MIB.dic +1593 -0
  57. data/lib/mibs/ietf/DOCS-BPI-MIB.dic +2634 -0
  58. data/lib/mibs/ietf/DOCS-CABLE-DEVICE-MIB.dic +5042 -0
  59. data/lib/mibs/ietf/DOCS-IETF-BPI2-MIB.dic +5478 -0
  60. data/lib/mibs/ietf/DOCS-IETF-CABLE-DEVICE-NOTIFICATION-MIB.dic +2447 -0
  61. data/lib/mibs/ietf/DOCS-IETF-QOS-MIB.dic +4886 -0
  62. data/lib/mibs/ietf/DOCS-IETF-SUBMGT-MIB.dic +1331 -0
  63. data/lib/mibs/ietf/DOCS-IF-MIB.dic +7980 -0
  64. data/lib/mibs/ietf/DOT12-IF-MIB.dic +1066 -0
  65. data/lib/mibs/ietf/DOT12-RPTR-MIB.dic +2669 -0
  66. data/lib/mibs/ietf/DOT3-EPON-MIB.dic +3297 -0
  67. data/lib/mibs/ietf/DOT3-OAM-MIB.dic +2830 -0
  68. data/lib/mibs/ietf/DS0-MIB.dic +466 -0
  69. data/lib/mibs/ietf/DS0BUNDLE-MIB.dic +468 -0
  70. data/lib/mibs/ietf/DS1-MIB.dic +4890 -0
  71. data/lib/mibs/ietf/DS3-MIB.dic +2719 -0
  72. data/lib/mibs/ietf/DSA-MIB.dic +888 -0
  73. data/lib/mibs/ietf/DSMON-MIB.dic +6177 -0
  74. data/lib/mibs/ietf/DVB-RCS-MIB.dic +5764 -0
  75. data/lib/mibs/ietf/EBN-MIB.dic +1026 -0
  76. data/lib/mibs/ietf/EFM-CU-MIB.dic +4335 -0
  77. data/lib/mibs/ietf/ENTITY-MIB.dic +2235 -0
  78. data/lib/mibs/ietf/ENTITY-SENSOR-MIB.dic +653 -0
  79. data/lib/mibs/ietf/ENTITY-STATE-MIB.dic +457 -0
  80. data/lib/mibs/ietf/ENTITY-STATE-TC-MIB.dic +260 -0
  81. data/lib/mibs/ietf/ETHER-CHIPSET-MIB.dic +787 -0
  82. data/lib/mibs/ietf/EtherLike-MIB.dic +2548 -0
  83. data/lib/mibs/ietf/FC-MGMT-MIB.dic +3465 -0
  84. data/lib/mibs/ietf/FCIP-MGMT-MIB.dic +1596 -0
  85. data/lib/mibs/ietf/FDDI-SMT73-MIB.dic +3378 -0
  86. data/lib/mibs/ietf/FIBRE-CHANNEL-FE-MIB.dic +2504 -0
  87. data/lib/mibs/ietf/FLOAT-TC-MIB.dic +128 -0
  88. data/lib/mibs/ietf/FLOW-METER-MIB.dic +3201 -0
  89. data/lib/mibs/ietf/FORCES-MIB.dic +598 -0
  90. data/lib/mibs/ietf/FR-ATM-PVC-SERVICE-IWF-MIB.dic +1601 -0
  91. data/lib/mibs/ietf/FR-MFR-MIB.dic +1351 -0
  92. data/lib/mibs/ietf/FRAME-RELAY-DTE-MIB.dic +1688 -0
  93. data/lib/mibs/ietf/FRNETSERV-MIB.dic +3940 -0
  94. data/lib/mibs/ietf/FRSLD-MIB.dic +2580 -0
  95. data/lib/mibs/ietf/Finisher-MIB.dic +1416 -0
  96. data/lib/mibs/ietf/GMPLS-LABEL-STD-MIB.dic +965 -0
  97. data/lib/mibs/ietf/GMPLS-LSR-STD-MIB.dic +693 -0
  98. data/lib/mibs/ietf/GMPLS-TC-STD-MIB.dic +180 -0
  99. data/lib/mibs/ietf/GMPLS-TE-STD-MIB.dic +2542 -0
  100. data/lib/mibs/ietf/GSMP-MIB.dic +2468 -0
  101. data/lib/mibs/ietf/HC-ALARM-MIB.dic +1050 -0
  102. data/lib/mibs/ietf/HC-PerfHist-TC-MIB.dic +310 -0
  103. data/lib/mibs/ietf/HC-RMON-MIB.dic +4456 -0
  104. data/lib/mibs/ietf/HDSL2-SHDSL-LINE-MIB.dic +3955 -0
  105. data/lib/mibs/ietf/HOST-RESOURCES-MIB.dic +2453 -0
  106. data/lib/mibs/ietf/HPR-IP-MIB.dic +640 -0
  107. data/lib/mibs/ietf/HPR-MIB.dic +1959 -0
  108. data/lib/mibs/ietf/IANA-ITU-ALARM-TC-MIB.dic +936 -0
  109. data/lib/mibs/ietf/IF-CAP-STACK-MIB.dic +356 -0
  110. data/lib/mibs/ietf/IF-INVERTED-STACK-MIB.dic +220 -0
  111. data/lib/mibs/ietf/IF-MIB.dic +2753 -0
  112. data/lib/mibs/ietf/IFCP-MGMT-MIB.dic +1717 -0
  113. data/lib/mibs/ietf/IGMP-STD-MIB.dic +809 -0
  114. data/lib/mibs/ietf/INET-ADDRESS-MIB.dic +570 -0
  115. data/lib/mibs/ietf/INTEGRATED-SERVICES-GUARANTEED-MIB.dic +319 -0
  116. data/lib/mibs/ietf/INTEGRATED-SERVICES-MIB.dic +1196 -0
  117. data/lib/mibs/ietf/INTERFACETOPN-MIB.dic +1705 -0
  118. data/lib/mibs/ietf/IP-FORWARD-MIB.dic +1853 -0
  119. data/lib/mibs/ietf/IP-MIB.dic +7064 -0
  120. data/lib/mibs/ietf/IPATM-IPMC-MIB.dic +4830 -0
  121. data/lib/mibs/ietf/IPFIX-MIB.dic +2334 -0
  122. data/lib/mibs/ietf/IPFIX-SELECTOR-MIB.dic +215 -0
  123. data/lib/mibs/ietf/IPMCAST-MIB.dic +3390 -0
  124. data/lib/mibs/ietf/IPMROUTE-STD-MIB.dic +1246 -0
  125. data/lib/mibs/ietf/IPOA-MIB.dic +2372 -0
  126. data/lib/mibs/ietf/IPS-AUTH-MIB.dic +1609 -0
  127. data/lib/mibs/ietf/IPSEC-SPD-MIB.dic +3989 -0
  128. data/lib/mibs/ietf/IPV6-FLOW-LABEL-MIB.dic +110 -0
  129. data/lib/mibs/ietf/IPV6-ICMP-MIB.dic +748 -0
  130. data/lib/mibs/ietf/IPV6-MIB.dic +2028 -0
  131. data/lib/mibs/ietf/IPV6-MLD-MIB.dic +659 -0
  132. data/lib/mibs/ietf/IPV6-TCP-MIB.dic +332 -0
  133. data/lib/mibs/ietf/IPV6-UDP-MIB.dic +209 -0
  134. data/lib/mibs/ietf/ISCSI-MIB.dic +4613 -0
  135. data/lib/mibs/ietf/ISDN-MIB.dic +1796 -0
  136. data/lib/mibs/ietf/ISIS-MIB.dic +6215 -0
  137. data/lib/mibs/ietf/ISNS-MIB.dic +6578 -0
  138. data/lib/mibs/ietf/ITU-ALARM-MIB.dic +665 -0
  139. data/lib/mibs/ietf/ITU-ALARM-TC-MIB.dic +137 -0
  140. data/lib/mibs/ietf/Job-Monitoring-MIB.dic +2519 -0
  141. data/lib/mibs/ietf/L2TP-MIB.dic +4050 -0
  142. data/lib/mibs/ietf/LANGTAG-TC-MIB.dic +104 -0
  143. data/lib/mibs/ietf/LISP-MIB.dic +4067 -0
  144. data/lib/mibs/ietf/LMP-MIB.dic +5166 -0
  145. data/lib/mibs/ietf/MALLOC-MIB.dic +2156 -0
  146. data/lib/mibs/ietf/MAU-MIB.dic +2619 -0
  147. data/lib/mibs/ietf/MIDCOM-MIB.dic +2856 -0
  148. data/lib/mibs/ietf/MIOX25-MIB.dic +828 -0
  149. data/lib/mibs/ietf/MIP-MIB.dic +3473 -0
  150. data/lib/mibs/ietf/MOBILEIPV6-MIB.dic +5228 -0
  151. data/lib/mibs/ietf/MPLS-FTN-STD-MIB.dic +1594 -0
  152. data/lib/mibs/ietf/MPLS-L3VPN-STD-MIB.dic +2548 -0
  153. data/lib/mibs/ietf/MPLS-LC-ATM-STD-MIB.dic +491 -0
  154. data/lib/mibs/ietf/MPLS-LC-FR-STD-MIB.dic +395 -0
  155. data/lib/mibs/ietf/MPLS-LDP-ATM-STD-MIB.dic +1019 -0
  156. data/lib/mibs/ietf/MPLS-LDP-FRAME-RELAY-STD-MIB.dic +862 -0
  157. data/lib/mibs/ietf/MPLS-LDP-GENERIC-STD-MIB.dic +445 -0
  158. data/lib/mibs/ietf/MPLS-LDP-STD-MIB.dic +3657 -0
  159. data/lib/mibs/ietf/MPLS-LSR-STD-MIB.dic +3103 -0
  160. data/lib/mibs/ietf/MPLS-TC-STD-MIB.dic +911 -0
  161. data/lib/mibs/ietf/MPLS-TE-STD-MIB.dic +3673 -0
  162. data/lib/mibs/ietf/MSDP-MIB.dic +1893 -0
  163. data/lib/mibs/ietf/MTA-MIB.dic +1898 -0
  164. data/lib/mibs/ietf/Modem-MIB.dic +2054 -0
  165. data/lib/mibs/ietf/NAT-MIB.dic +3866 -0
  166. data/lib/mibs/ietf/NETWORK-SERVICES-MIB.dic +1034 -0
  167. data/lib/mibs/ietf/NHDP-MIB.dic +3005 -0
  168. data/lib/mibs/ietf/NHRP-MIB.dic +3660 -0
  169. data/lib/mibs/ietf/NOTIFICATION-LOG-MIB.dic +1156 -0
  170. data/lib/mibs/ietf/NTPv4-MIB.dic +1535 -0
  171. data/lib/mibs/ietf/OPT-IF-MIB.dic +8972 -0
  172. data/lib/mibs/ietf/OSPF-MIB.dic +5963 -0
  173. data/lib/mibs/ietf/OSPF-TRAP-MIB.dic +1190 -0
  174. data/lib/mibs/ietf/OSPFV3-MIB.dic +5708 -0
  175. data/lib/mibs/ietf/P-BRIDGE-MIB.dic +1499 -0
  176. data/lib/mibs/ietf/PARALLEL-MIB.dic +476 -0
  177. data/lib/mibs/ietf/PIM-MIB.dic +1393 -0
  178. data/lib/mibs/ietf/PIM-STD-MIB.dic +6819 -0
  179. data/lib/mibs/ietf/PINT-MIB.dic +830 -0
  180. data/lib/mibs/ietf/PKTC-IETF-MTA-MIB.dic +3191 -0
  181. data/lib/mibs/ietf/PKTC-IETF-SIG-MIB.dic +4713 -0
  182. data/lib/mibs/ietf/PMIPV6-MIB.dic +3010 -0
  183. data/lib/mibs/ietf/PMIPV6-TC-MIB.dic +293 -0
  184. data/lib/mibs/ietf/POLICY-BASED-MANAGEMENT-MIB.dic +3316 -0
  185. data/lib/mibs/ietf/POWER-ETHERNET-MIB.dic +959 -0
  186. data/lib/mibs/ietf/PPP-BRIDGE-NCP-MIB.dic +587 -0
  187. data/lib/mibs/ietf/PPP-IP-NCP-MIB.dic +269 -0
  188. data/lib/mibs/ietf/PPP-LCP-MIB.dic +994 -0
  189. data/lib/mibs/ietf/PPP-SEC-MIB.dic +411 -0
  190. data/lib/mibs/ietf/PSAMP-MIB.dic +998 -0
  191. data/lib/mibs/ietf/PTOPO-MIB.dic +1135 -0
  192. data/lib/mibs/ietf/PW-ATM-MIB.dic +1642 -0
  193. data/lib/mibs/ietf/PW-CEP-STD-MIB.dic +3661 -0
  194. data/lib/mibs/ietf/PW-STD-MIB.dic +3592 -0
  195. data/lib/mibs/ietf/PW-TC-STD-MIB.dic +437 -0
  196. data/lib/mibs/ietf/PW-TDM-MIB.dic +1896 -0
  197. data/lib/mibs/ietf/PerfHist-TC-MIB.dic +152 -0
  198. data/lib/mibs/ietf/Printer-MIB.dic +6665 -0
  199. data/lib/mibs/ietf/Q-BRIDGE-MIB.dic +3115 -0
  200. data/lib/mibs/ietf/RADIUS-ACC-CLIENT-MIB.dic +991 -0
  201. data/lib/mibs/ietf/RADIUS-ACC-SERVER-MIB.dic +1183 -0
  202. data/lib/mibs/ietf/RADIUS-AUTH-CLIENT-MIB.dic +1073 -0
  203. data/lib/mibs/ietf/RADIUS-AUTH-SERVER-MIB.dic +1251 -0
  204. data/lib/mibs/ietf/RADIUS-DYNAUTH-CLIENT-MIB.dic +1116 -0
  205. data/lib/mibs/ietf/RADIUS-DYNAUTH-SERVER-MIB.dic +1003 -0
  206. data/lib/mibs/ietf/RAQMON-MIB.dic +2695 -0
  207. data/lib/mibs/ietf/RBRIDGE-MIB.dic +2981 -0
  208. data/lib/mibs/ietf/RDBMS-MIB.dic +1935 -0
  209. data/lib/mibs/ietf/RFC1065-SMI.dic +108 -0
  210. data/lib/mibs/ietf/RFC1155-SMI.dic +118 -0
  211. data/lib/mibs/ietf/RFC1158-MIB.dic +2440 -0
  212. data/lib/mibs/ietf/RFC1213-MIB.dic +3434 -0
  213. data/lib/mibs/ietf/RFC1269-MIB.dic +557 -0
  214. data/lib/mibs/ietf/RFC1271-MIB.dic +4135 -0
  215. data/lib/mibs/ietf/RFC1285-MIB.dic +2842 -0
  216. data/lib/mibs/ietf/RFC1316-MIB.dic +800 -0
  217. data/lib/mibs/ietf/RFC1381-MIB.dic +1347 -0
  218. data/lib/mibs/ietf/RFC1382-MIB.dic +3820 -0
  219. data/lib/mibs/ietf/RFC1414-MIB.dic +214 -0
  220. data/lib/mibs/ietf/RIPv2-MIB.dic +773 -0
  221. data/lib/mibs/ietf/RMON-MIB.dic +5551 -0
  222. data/lib/mibs/ietf/RMON2-MIB.dic +8224 -0
  223. data/lib/mibs/ietf/ROHC-MIB.dic +1613 -0
  224. data/lib/mibs/ietf/ROHC-RTP-MIB.dic +859 -0
  225. data/lib/mibs/ietf/ROHC-UNCOMPRESSED-MIB.dic +267 -0
  226. data/lib/mibs/ietf/RPKI-ROUTER-MIB.dic +1363 -0
  227. data/lib/mibs/ietf/RS-232-MIB.dic +1335 -0
  228. data/lib/mibs/ietf/RSERPOOL-MIB.dic +2501 -0
  229. data/lib/mibs/ietf/RSTP-MIB.dic +427 -0
  230. data/lib/mibs/ietf/RSVP-MIB.dic +4135 -0
  231. data/lib/mibs/ietf/RTP-MIB.dic +1376 -0
  232. data/lib/mibs/ietf/SCSI-MIB.dic +3804 -0
  233. data/lib/mibs/ietf/SCTP-MIB.dic +1924 -0
  234. data/lib/mibs/ietf/SFLOW-MIB.dic +568 -0
  235. data/lib/mibs/ietf/SIP-COMMON-MIB.dic +2769 -0
  236. data/lib/mibs/ietf/SIP-MIB.dic +1438 -0
  237. data/lib/mibs/ietf/SIP-SERVER-MIB.dic +1150 -0
  238. data/lib/mibs/ietf/SIP-TC-MIB.dic +257 -0
  239. data/lib/mibs/ietf/SIP-UA-MIB.dic +268 -0
  240. data/lib/mibs/ietf/SLAPM-MIB.dic +4527 -0
  241. data/lib/mibs/ietf/SMON-MIB.dic +1758 -0
  242. data/lib/mibs/ietf/SNA-NAU-MIB.dic +4042 -0
  243. data/lib/mibs/ietf/SNA-SDLC-MIB.dic +3858 -0
  244. data/lib/mibs/ietf/SNMP-COMMUNITY-MIB.dic +715 -0
  245. data/lib/mibs/ietf/SNMP-FRAMEWORK-MIB.dic +709 -0
  246. data/lib/mibs/ietf/SNMP-MPD-MIB.dic +230 -0
  247. data/lib/mibs/ietf/SNMP-NOTIFICATION-MIB.dic +859 -0
  248. data/lib/mibs/ietf/SNMP-PROXY-MIB.dic +414 -0
  249. data/lib/mibs/ietf/SNMP-REPEATER-MIB.dic +4335 -0
  250. data/lib/mibs/ietf/SNMP-SSH-TM-MIB.dic +447 -0
  251. data/lib/mibs/ietf/SNMP-TARGET-MIB.dic +924 -0
  252. data/lib/mibs/ietf/SNMP-TLS-TM-MIB.dic +1449 -0
  253. data/lib/mibs/ietf/SNMP-TSM-MIB.dic +315 -0
  254. data/lib/mibs/ietf/SNMP-USER-BASED-SM-MIB.dic +1164 -0
  255. data/lib/mibs/ietf/SNMP-USM-AES-MIB.dic +95 -0
  256. data/lib/mibs/ietf/SNMP-USM-DH-OBJECTS-MIB.dic +653 -0
  257. data/lib/mibs/ietf/SNMP-VIEW-BASED-ACM-MIB.dic +1202 -0
  258. data/lib/mibs/ietf/SNMPv2-MIB.dic +1382 -0
  259. data/lib/mibs/ietf/SNMPv2-SMI.dic +223 -0
  260. data/lib/mibs/ietf/SNMPv2-USEC-MIB.dic +405 -0
  261. data/lib/mibs/ietf/SONET-MIB.dic +3308 -0
  262. data/lib/mibs/ietf/SOURCE-ROUTING-MIB.dic +542 -0
  263. data/lib/mibs/ietf/SSPM-MIB.dic +1530 -0
  264. data/lib/mibs/ietf/SYSAPPL-MIB.dic +2092 -0
  265. data/lib/mibs/ietf/T11-FC-FABRIC-ADDR-MGR-MIB.dic +1779 -0
  266. data/lib/mibs/ietf/T11-FC-FABRIC-CONFIG-SERVER-MIB.dic +2822 -0
  267. data/lib/mibs/ietf/T11-FC-FABRIC-LOCK-MIB.dic +700 -0
  268. data/lib/mibs/ietf/T11-FC-FSPF-MIB.dic +1889 -0
  269. data/lib/mibs/ietf/T11-FC-NAME-SERVER-MIB.dic +1775 -0
  270. data/lib/mibs/ietf/T11-FC-ROUTE-MIB.dic +655 -0
  271. data/lib/mibs/ietf/T11-FC-RSCN-MIB.dic +1110 -0
  272. data/lib/mibs/ietf/T11-FC-VIRTUAL-FABRIC-MIB.dic +770 -0
  273. data/lib/mibs/ietf/T11-FC-ZONE-SERVER-MIB.dic +3886 -0
  274. data/lib/mibs/ietf/T11-TC-MIB.dic +110 -0
  275. data/lib/mibs/ietf/TCP-ESTATS-MIB.dic +3926 -0
  276. data/lib/mibs/ietf/TCP-MIB.dic +1319 -0
  277. data/lib/mibs/ietf/TCPIPX-MIB.dic +457 -0
  278. data/lib/mibs/ietf/TE-LINK-STD-MIB.dic +2876 -0
  279. data/lib/mibs/ietf/TE-MIB.dic +2924 -0
  280. data/lib/mibs/ietf/TED-MIB.dic +1749 -0
  281. data/lib/mibs/ietf/TIME-AGGREGATE-MIB.dic +550 -0
  282. data/lib/mibs/ietf/TN3270E-MIB.dic +2785 -0
  283. data/lib/mibs/ietf/TN3270E-RT-MIB.dic +1317 -0
  284. data/lib/mibs/ietf/TOKEN-RING-RMON-MIB.dic +2820 -0
  285. data/lib/mibs/ietf/TOKENRING-MIB.dic +1184 -0
  286. data/lib/mibs/ietf/TOKENRING-STATION-SR-MIB.dic +292 -0
  287. data/lib/mibs/ietf/TRANSPORT-ADDRESS-MIB.dic +610 -0
  288. data/lib/mibs/ietf/TRIP-MIB.dic +3159 -0
  289. data/lib/mibs/ietf/TRIP-TC-MIB.dic +241 -0
  290. data/lib/mibs/ietf/TUNNEL-MIB.dic +1095 -0
  291. data/lib/mibs/ietf/UDP-MIB.dic +751 -0
  292. data/lib/mibs/ietf/UDPLITE-MIB.dic +704 -0
  293. data/lib/mibs/ietf/UPS-MIB.dic +3088 -0
  294. data/lib/mibs/ietf/URI-TC-MIB.dic +193 -0
  295. data/lib/mibs/ietf/UUID-TC-MIB.dic +135 -0
  296. data/lib/mibs/ietf/VDSL-LINE-EXT-MCM-MIB.dic +989 -0
  297. data/lib/mibs/ietf/VDSL-LINE-EXT-SCM-MIB.dic +605 -0
  298. data/lib/mibs/ietf/VDSL-LINE-MIB.dic +4518 -0
  299. data/lib/mibs/ietf/VDSL2-LINE-MIB.dic +11029 -0
  300. data/lib/mibs/ietf/VDSL2-LINE-TC-MIB.dic +3152 -0
  301. data/lib/mibs/ietf/VPN-TC-STD-MIB.dic +121 -0
  302. data/lib/mibs/ietf/VRRP-MIB.dic +1163 -0
  303. data/lib/mibs/ietf/VRRPV3-MIB.dic +1403 -0
  304. data/lib/mibs/ietf/WWW-MIB.dic +1810 -0
  305. data/lib/mibs/logstash/iso.dic +18 -0
  306. data/logstash-input-snmp.gemspec +1 -1
  307. data/spec/inputs/snmp/mib_spec.rb +10 -17
  308. data/spec/inputs/snmp_spec.rb +27 -1
  309. metadata +302 -2
@@ -0,0 +1,1613 @@
1
+ # python version 1.0 DO NOT EDIT
2
+ #
3
+ # This python file has been generated by smidump version 0.5.0:
4
+ #
5
+ # smidump -f python ROHC-MIB
6
+
7
+ FILENAME = "./libsmi-0.5.0/mibs/ietf/ROHC-MIB"
8
+
9
+ MIB = {
10
+ "moduleName" : "ROHC-MIB",
11
+
12
+ "ROHC-MIB" : {
13
+ "nodetype" : "module",
14
+ "language" : "SMIv2",
15
+ "organization" :
16
+ """IETF Robust Header Compression Working Group""",
17
+ "contact" :
18
+ """WG charter:
19
+ http://www.ietf.org/html.charters/rohc-charter.html
20
+
21
+ Mailing Lists:
22
+ General Discussion: rohc@ietf.org
23
+ To Subscribe: rohc-request@ietf.org
24
+ In Body: subscribe your_email_address
25
+
26
+ Editor:
27
+ Juergen Quittek
28
+ NEC Europe Ltd.
29
+ Network Laboratories
30
+ Kurfuersten-Anlage 36
31
+
32
+
33
+
34
+ 69221 Heidelberg
35
+ Germany
36
+ Tel: +49 6221 90511-15
37
+ EMail: quittek@netlab.nec.de""",
38
+ "description" :
39
+ """This MIB module defines a set of basic objects for
40
+ monitoring and configuring robust header compression.
41
+ The module covers information about running instances
42
+ of ROHC (compressors or decompressors) at IP interfaces.
43
+
44
+ Information about compressor contexts and decompressor
45
+ contexts has different structure for different profiles.
46
+ Therefore it is not provided by this MIB module, but by
47
+ individual modules for different profiles.
48
+
49
+ Copyright (C) The Internet Society (2004). The
50
+ initial version of this MIB module was published
51
+ in RFC 3816. For full legal notices see the RFC
52
+ itself or see:
53
+ http://www.ietf.org/copyrights/ianamib.html""",
54
+ "revisions" : (
55
+ {
56
+ "date" : "2004-06-03 00:00",
57
+ "description" :
58
+ """Initial version, published as RFC 3816.""",
59
+ },
60
+ ),
61
+ "identity node" : "rohcMIB",
62
+ },
63
+
64
+ "imports" : (
65
+ {"module" : "SNMPv2-SMI", "name" : "MODULE-IDENTITY"},
66
+ {"module" : "SNMPv2-SMI", "name" : "OBJECT-TYPE"},
67
+ {"module" : "SNMPv2-SMI", "name" : "Unsigned32"},
68
+ {"module" : "SNMPv2-SMI", "name" : "Counter32"},
69
+ {"module" : "SNMPv2-SMI", "name" : "mib-2"},
70
+ {"module" : "SNMPv2-TC", "name" : "TEXTUAL-CONVENTION"},
71
+ {"module" : "SNMPv2-TC", "name" : "TruthValue"},
72
+ {"module" : "SNMPv2-TC", "name" : "TimeInterval"},
73
+ {"module" : "SNMPv2-TC", "name" : "DateAndTime"},
74
+ {"module" : "SNMPv2-CONF", "name" : "MODULE-COMPLIANCE"},
75
+ {"module" : "SNMPv2-CONF", "name" : "OBJECT-GROUP"},
76
+ {"module" : "SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
77
+ {"module" : "IF-MIB", "name" : "ifIndex"},
78
+ ),
79
+
80
+ "typedefs" : {
81
+ "RohcChannelIdentifier" : {
82
+ "basetype" : "Unsigned32",
83
+ "status" : "current",
84
+ "ranges" : [
85
+ {
86
+ "min" : "1",
87
+ "max" : "4294967295"
88
+ },
89
+ ],
90
+ "range" : {
91
+ "min" : "1",
92
+ "max" : "4294967295"
93
+ },
94
+ "format" : "d",
95
+ "description" :
96
+ """A number identifying a channel.
97
+ The value of 0 must not be used as identifier
98
+ of an existing channel.""",
99
+ },
100
+ "RohcChannelIdentifierOrZero" : {
101
+ "basetype" : "Unsigned32",
102
+ "status" : "current",
103
+ "ranges" : [
104
+ {
105
+ "min" : "0",
106
+ "max" : "4294967295"
107
+ },
108
+ ],
109
+ "range" : {
110
+ "min" : "0",
111
+ "max" : "4294967295"
112
+ },
113
+ "format" : "d",
114
+ "description" :
115
+ """A number identifying a channel.
116
+ The value of 0 is indicates that
117
+ no channel is identified.""",
118
+ },
119
+ "RohcCompressionRatio" : {
120
+ "basetype" : "Unsigned32",
121
+ "status" : "current",
122
+ "format" : "d",
123
+ "description" :
124
+ """A number indicating a compression ratio over
125
+
126
+
127
+
128
+ a set of bytes. The value is defined as
129
+ 1000 * bytes(compressed) / bytes(original)
130
+ rounded to the next integer value.
131
+
132
+ Note that compressed sets of bytes can be larger
133
+ than the corresponding uncompressed ones.
134
+ Therefore, the number can be greater than 1000.""",
135
+ },
136
+ }, # typedefs
137
+
138
+ "nodes" : {
139
+ "rohcMIB" : {
140
+ "nodetype" : "node",
141
+ "moduleName" : "ROHC-MIB",
142
+ "oid" : "1.3.6.1.2.1.112",
143
+ "status" : "current",
144
+ }, # node
145
+ "rohcObjects" : {
146
+ "nodetype" : "node",
147
+ "moduleName" : "ROHC-MIB",
148
+ "oid" : "1.3.6.1.2.1.112.1",
149
+ }, # node
150
+ "rohcInstanceObjects" : {
151
+ "nodetype" : "node",
152
+ "moduleName" : "ROHC-MIB",
153
+ "oid" : "1.3.6.1.2.1.112.1.1",
154
+ }, # node
155
+ "rohcChannelTable" : {
156
+ "nodetype" : "table",
157
+ "moduleName" : "ROHC-MIB",
158
+ "oid" : "1.3.6.1.2.1.112.1.1.1",
159
+ "status" : "current",
160
+ "description" :
161
+ """This table lists and describes all ROHC channels
162
+ per interface.""",
163
+ }, # table
164
+ "rohcChannelEntry" : {
165
+ "nodetype" : "row",
166
+ "moduleName" : "ROHC-MIB",
167
+ "oid" : "1.3.6.1.2.1.112.1.1.1.1",
168
+ "status" : "current",
169
+ "linkage" : [
170
+ "ifIndex",
171
+ "rohcChannelID",
172
+ ],
173
+ "description" :
174
+ """An entry describing a particular script. Every script that
175
+ is stored in non-volatile memory is required to appear in
176
+
177
+
178
+
179
+ this script table.
180
+
181
+ Note, that the rohcChannelID identifies the channel
182
+ uniquely. The ifIndex is part of the index of this table
183
+ just in order to allow addressing channels per interface.""",
184
+ }, # row
185
+ "rohcChannelID" : {
186
+ "nodetype" : "column",
187
+ "moduleName" : "ROHC-MIB",
188
+ "oid" : "1.3.6.1.2.1.112.1.1.1.1.2",
189
+ "status" : "current",
190
+ "syntax" : {
191
+ "type" : { "module" :"ROHC-MIB", "name" : "RohcChannelIdentifier"},
192
+ },
193
+ "access" : "noaccess",
194
+ "description" :
195
+ """The locally arbitrary, but unique identifier associated
196
+ with this channel. The value is REQUIRED to be unique
197
+ per ROHC MIB implementation independent of the associated
198
+ interface.
199
+
200
+ The value is REQUIRED to remain constant at least from one
201
+ re-initialization of the entity's network management system
202
+ to the next re-initialization. It is RECOMMENDED that the
203
+ value persist across such re-initializations.""",
204
+ "reference" :
205
+ """RFC 3095, Section 5.1.1""",
206
+ }, # column
207
+ "rohcChannelType" : {
208
+ "nodetype" : "column",
209
+ "moduleName" : "ROHC-MIB",
210
+ "oid" : "1.3.6.1.2.1.112.1.1.1.1.3",
211
+ "status" : "current",
212
+ "syntax" : {
213
+ "type" : {
214
+ "basetype" : "Enumeration",
215
+ "notInUse" : {
216
+ "nodetype" : "namednumber",
217
+ "number" : "1"
218
+ },
219
+ "rohc" : {
220
+ "nodetype" : "namednumber",
221
+ "number" : "2"
222
+ },
223
+ "dedicatedFeedback" : {
224
+ "nodetype" : "namednumber",
225
+ "number" : "3"
226
+ },
227
+ },
228
+ },
229
+ "access" : "readonly",
230
+ "description" :
231
+ """Type of usage of the channel. A channel might be currently
232
+ not in use for ROHC or feedback, it might be in use as
233
+ a ROHC channel carrying packets and optional piggy-backed
234
+ feedback, or it might be used as a dedicated feedback
235
+ channel exclusively carrying feedback.""",
236
+ }, # column
237
+ "rohcChannelFeedbackFor" : {
238
+ "nodetype" : "column",
239
+ "moduleName" : "ROHC-MIB",
240
+ "oid" : "1.3.6.1.2.1.112.1.1.1.1.4",
241
+ "status" : "current",
242
+ "syntax" : {
243
+ "type" : { "module" :"ROHC-MIB", "name" : "RohcChannelIdentifierOrZero"},
244
+ },
245
+ "access" : "readonly",
246
+ "description" :
247
+ """The index of another channel of this interface for which
248
+ the channel serves as feedback channel.
249
+
250
+ If no feedback information is transferred on this channel,
251
+ then the value of this ID is 0. If the channel type is set
252
+ to notInUse(1), then the value of this object must be 0.
253
+ If the channel type is rohc(2) and the value of this object
254
+ is a valid channel ID, then feedback information is
255
+ piggy-backed on the ROHC channel. If the channel type is
256
+ dedicatedFeedback(3), then feedback is transferred on this
257
+ channel and the value of this object MUST be different from
258
+ 0 and MUST identify an existing ROHC channel.""",
259
+ "reference" :
260
+ """RFC 3095, Section 5.1.1""",
261
+ }, # column
262
+ "rohcChannelDescr" : {
263
+ "nodetype" : "column",
264
+ "moduleName" : "ROHC-MIB",
265
+ "oid" : "1.3.6.1.2.1.112.1.1.1.1.5",
266
+ "status" : "current",
267
+ "syntax" : {
268
+ "type" : { "module" :"SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
269
+ },
270
+ "access" : "readonly",
271
+ "description" :
272
+ """A textual description of the channel.""",
273
+ }, # column
274
+ "rohcChannelStatus" : {
275
+ "nodetype" : "column",
276
+ "moduleName" : "ROHC-MIB",
277
+ "oid" : "1.3.6.1.2.1.112.1.1.1.1.6",
278
+ "status" : "current",
279
+ "syntax" : {
280
+ "type" : {
281
+ "basetype" : "Enumeration",
282
+ "enabled" : {
283
+ "nodetype" : "namednumber",
284
+ "number" : "1"
285
+ },
286
+ "disabled" : {
287
+ "nodetype" : "namednumber",
288
+ "number" : "2"
289
+ },
290
+ },
291
+ },
292
+ "access" : "readonly",
293
+ "description" :
294
+ """Status of the channel.""",
295
+ }, # column
296
+ "rohcInstanceTable" : {
297
+ "nodetype" : "table",
298
+ "moduleName" : "ROHC-MIB",
299
+ "oid" : "1.3.6.1.2.1.112.1.1.2",
300
+ "status" : "current",
301
+ "description" :
302
+ """This table lists properties of running instances
303
+ of robust header compressors and decompressors
304
+ at IP interfaces. It is indexed by interface number,
305
+ the type of instance (compressor or decompressor),
306
+ and the ID of the channel used by the instance as
307
+ ROHC channel.
308
+
309
+ Note that the rohcChannelID uniquely identifies an
310
+ instance. The ifIndex and rohcInstanceType are part
311
+ of the index, because it simplifies accessing instances
312
+ per interface and for addressing either compressors or
313
+ decompressors only.""",
314
+ }, # table
315
+ "rohcInstanceEntry" : {
316
+ "nodetype" : "row",
317
+ "moduleName" : "ROHC-MIB",
318
+ "oid" : "1.3.6.1.2.1.112.1.1.2.1",
319
+ "status" : "current",
320
+ "linkage" : [
321
+ "ifIndex",
322
+ "rohcInstanceType",
323
+ "rohcChannelID",
324
+ ],
325
+ "description" :
326
+ """An entry describing a particular instance
327
+ of a robust header compressor or decompressor.""",
328
+ }, # row
329
+ "rohcInstanceType" : {
330
+ "nodetype" : "column",
331
+ "moduleName" : "ROHC-MIB",
332
+ "oid" : "1.3.6.1.2.1.112.1.1.2.1.2",
333
+ "status" : "current",
334
+ "syntax" : {
335
+ "type" : {
336
+ "basetype" : "Enumeration",
337
+ "compressor" : {
338
+ "nodetype" : "namednumber",
339
+ "number" : "1"
340
+ },
341
+ "decompressor" : {
342
+ "nodetype" : "namednumber",
343
+ "number" : "2"
344
+ },
345
+ },
346
+ },
347
+ "access" : "noaccess",
348
+ "description" :
349
+ """Type of the instance of ROHC. It is either a
350
+ compressor instance or a decompressor instance.""",
351
+ }, # column
352
+ "rohcInstanceFBChannelID" : {
353
+ "nodetype" : "column",
354
+ "moduleName" : "ROHC-MIB",
355
+ "oid" : "1.3.6.1.2.1.112.1.1.2.1.4",
356
+ "status" : "current",
357
+ "syntax" : {
358
+ "type" : { "module" :"ROHC-MIB", "name" : "RohcChannelIdentifierOrZero"},
359
+ },
360
+ "access" : "readonly",
361
+ "description" :
362
+ """Identifier of the channel used for feedback.
363
+ If no feedback channel is used, the value of
364
+ this object is 0 .""",
365
+ "reference" :
366
+ """RFC 3095, Section 5.1.1""",
367
+ }, # column
368
+ "rohcInstanceVendor" : {
369
+ "nodetype" : "column",
370
+ "moduleName" : "ROHC-MIB",
371
+ "oid" : "1.3.6.1.2.1.112.1.1.2.1.5",
372
+ "status" : "current",
373
+ "syntax" : {
374
+ "type" : { "module" :"", "name" : "ObjectIdentifier"},
375
+ },
376
+ "access" : "readonly",
377
+ "description" :
378
+ """An object identifier that identifies the vendor who
379
+ provides the implementation of robust header description.
380
+ This object identifier SHALL point to the object identifier
381
+ directly below the enterprise object identifier
382
+ {1 3 6 1 4 1} allocated for the vendor. The value must be
383
+ the object identifier {0 0} if the vendor is not known.""",
384
+ }, # column
385
+ "rohcInstanceVersion" : {
386
+ "nodetype" : "column",
387
+ "moduleName" : "ROHC-MIB",
388
+ "oid" : "1.3.6.1.2.1.112.1.1.2.1.6",
389
+ "status" : "current",
390
+ "syntax" : {
391
+ "type" : {
392
+ "basetype" : "OctetString",
393
+ "parent module" : {
394
+ "name" : "SNMP-FRAMEWORK-MIB",
395
+ "type" : "SnmpAdminString",
396
+ },
397
+ "ranges" : [
398
+ {
399
+ "min" : "0",
400
+ "max" : "32"
401
+ },
402
+ ],
403
+ "range" : {
404
+ "min" : "0",
405
+ "max" : "32"
406
+ },
407
+ },
408
+ },
409
+ "access" : "readonly",
410
+ "description" :
411
+ """The version number of the implementation of robust header
412
+ compression. The zero-length string shall be used if the
413
+ implementation does not have a version number.
414
+
415
+
416
+
417
+
418
+ It is suggested that the version number consist of one or
419
+ more decimal numbers separated by dots, where the first
420
+ number is called the major version number.""",
421
+ }, # column
422
+ "rohcInstanceDescr" : {
423
+ "nodetype" : "column",
424
+ "moduleName" : "ROHC-MIB",
425
+ "oid" : "1.3.6.1.2.1.112.1.1.2.1.7",
426
+ "status" : "current",
427
+ "syntax" : {
428
+ "type" : { "module" :"SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
429
+ },
430
+ "access" : "readonly",
431
+ "description" :
432
+ """A textual description of the implementation.""",
433
+ }, # column
434
+ "rohcInstanceClockRes" : {
435
+ "nodetype" : "column",
436
+ "moduleName" : "ROHC-MIB",
437
+ "oid" : "1.3.6.1.2.1.112.1.1.2.1.8",
438
+ "status" : "current",
439
+ "syntax" : {
440
+ "type" : { "module" :"", "name" : "Unsigned32"},
441
+ },
442
+ "access" : "readonly",
443
+ "units" : "milliseconds",
444
+ "description" :
445
+ """This object indicates the system clock resolution in
446
+ units of milliseconds. A zero (0) value means that there
447
+ is no clock available.""",
448
+ }, # column
449
+ "rohcInstanceMaxCID" : {
450
+ "nodetype" : "column",
451
+ "moduleName" : "ROHC-MIB",
452
+ "oid" : "1.3.6.1.2.1.112.1.1.2.1.9",
453
+ "status" : "current",
454
+ "syntax" : {
455
+ "type" : {
456
+ "basetype" : "Unsigned32",
457
+ "ranges" : [
458
+ {
459
+ "min" : "1",
460
+ "max" : "16383"
461
+ },
462
+ ],
463
+ "range" : {
464
+ "min" : "1",
465
+ "max" : "16383"
466
+ },
467
+ },
468
+ },
469
+ "access" : "readonly",
470
+ "description" :
471
+ """The highest context ID number to be used by the
472
+ compressor. Note that this parameter is not coupled to,
473
+ but in effect further constrained by,
474
+ rohcChannelLargeCIDs.""",
475
+ "reference" :
476
+ """RFC 3095, Section 5.1.1""",
477
+ }, # column
478
+ "rohcInstanceLargeCIDs" : {
479
+ "nodetype" : "column",
480
+ "moduleName" : "ROHC-MIB",
481
+ "oid" : "1.3.6.1.2.1.112.1.1.2.1.10",
482
+ "status" : "current",
483
+ "syntax" : {
484
+ "type" : { "module" :"SNMPv2-TC", "name" : "TruthValue"},
485
+ },
486
+ "access" : "readonly",
487
+ "description" :
488
+ """When retrieved, this boolean object returns false if
489
+ the short CID representation (0 bytes or 1 prefix byte,
490
+ covering CID 0 to 15) is used; it returns true, if the
491
+ embedded CID representation (1 or 2 embedded CID bytes
492
+ covering CID 0 to 16383) is used.""",
493
+ "reference" :
494
+ """RFC 3095, Section 5.1.1""",
495
+ }, # column
496
+ "rohcInstanceMRRU" : {
497
+ "nodetype" : "column",
498
+ "moduleName" : "ROHC-MIB",
499
+ "oid" : "1.3.6.1.2.1.112.1.1.2.1.11",
500
+ "status" : "current",
501
+ "syntax" : {
502
+ "type" : { "module" :"", "name" : "Unsigned32"},
503
+ },
504
+ "access" : "readonly",
505
+ "description" :
506
+ """Maximum reconstructed reception unit. This is the
507
+ size of the largest reconstructed unit in octets that
508
+ the decompressor is expected to reassemble from
509
+ segments (see RFC 3095, Section 5.2.5). Note that this
510
+ size includes the CRC. If MRRU is negotiated to be 0,
511
+ no segment headers are allowed on the channel.""",
512
+ "reference" :
513
+ """RFC 3095, Section 5.1.1""",
514
+ }, # column
515
+ "rohcInstanceContextStorageTime" : {
516
+ "nodetype" : "column",
517
+ "moduleName" : "ROHC-MIB",
518
+ "oid" : "1.3.6.1.2.1.112.1.1.2.1.12",
519
+ "status" : "current",
520
+ "syntax" : {
521
+ "type" : { "module" :"SNMPv2-TC", "name" : "TimeInterval"},
522
+ },
523
+ "access" : "readwrite",
524
+ "default" : "360000",
525
+ "units" : "centi-seconds",
526
+ "description" :
527
+ """This object indicates the default maximum amount of time
528
+ information on a context belonging to this instance is kept
529
+ as entry in the rohcContextTable after the context is
530
+ expired or terminated. The value of this object is used
531
+ to initialize rohcContexStorageTime object when a new
532
+ context is created.
533
+ Changing the value of an rohcInstanceContextStorageTime
534
+ instance does not affect any entry of the rohcContextTable
535
+ created previously.
536
+ ROHC-MIB implementations SHOULD store the set value of this
537
+ object persistently.""",
538
+ }, # column
539
+ "rohcInstanceStatus" : {
540
+ "nodetype" : "column",
541
+ "moduleName" : "ROHC-MIB",
542
+ "oid" : "1.3.6.1.2.1.112.1.1.2.1.13",
543
+ "status" : "current",
544
+ "syntax" : {
545
+ "type" : {
546
+ "basetype" : "Enumeration",
547
+ "enabled" : {
548
+ "nodetype" : "namednumber",
549
+ "number" : "1"
550
+ },
551
+ "disabled" : {
552
+ "nodetype" : "namednumber",
553
+ "number" : "2"
554
+ },
555
+ },
556
+ },
557
+ "access" : "readonly",
558
+ "description" :
559
+ """Status of the instance of ROHC.""",
560
+ }, # column
561
+ "rohcInstanceContextsTotal" : {
562
+ "nodetype" : "column",
563
+ "moduleName" : "ROHC-MIB",
564
+ "oid" : "1.3.6.1.2.1.112.1.1.2.1.14",
565
+ "status" : "current",
566
+ "syntax" : {
567
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
568
+ },
569
+ "access" : "readonly",
570
+ "description" :
571
+ """Counter of all contexts created by this instance.
572
+
573
+ Discontinuities in the value of this counter can
574
+ occur at re-initialization of the management
575
+ system, and at other times as indicated by the
576
+ value of ifCounterDiscontinuityTime.""",
577
+ }, # column
578
+ "rohcInstanceContextsCurrent" : {
579
+ "nodetype" : "column",
580
+ "moduleName" : "ROHC-MIB",
581
+ "oid" : "1.3.6.1.2.1.112.1.1.2.1.15",
582
+ "status" : "current",
583
+ "syntax" : {
584
+ "type" : { "module" :"", "name" : "Unsigned32"},
585
+ },
586
+ "access" : "readonly",
587
+ "description" :
588
+ """Number of currently active contexts created by this
589
+ instance.""",
590
+ }, # column
591
+ "rohcInstancePackets" : {
592
+ "nodetype" : "column",
593
+ "moduleName" : "ROHC-MIB",
594
+ "oid" : "1.3.6.1.2.1.112.1.1.2.1.16",
595
+ "status" : "current",
596
+ "syntax" : {
597
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
598
+ },
599
+ "access" : "readonly",
600
+ "description" :
601
+ """Counter of all packets passing this instance.
602
+
603
+ Discontinuities in the value of this counter can
604
+ occur at re-initialization of the management
605
+ system, and at other times as indicated by the
606
+ value of ifCounterDiscontinuityTime.""",
607
+ }, # column
608
+ "rohcInstanceIRs" : {
609
+ "nodetype" : "column",
610
+ "moduleName" : "ROHC-MIB",
611
+ "oid" : "1.3.6.1.2.1.112.1.1.2.1.17",
612
+ "status" : "current",
613
+ "syntax" : {
614
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
615
+ },
616
+ "access" : "readonly",
617
+ "description" :
618
+ """The number of all IR packets that are either sent
619
+ or received by this instance.
620
+
621
+ Discontinuities in the value of this counter can
622
+ occur at re-initialization of the management
623
+ system, and at other times as indicated by the
624
+
625
+
626
+
627
+ value of ifCounterDiscontinuityTime.""",
628
+ "reference" :
629
+ """RFC 3095, Section 5.7.7.1""",
630
+ }, # column
631
+ "rohcInstanceIRDYNs" : {
632
+ "nodetype" : "column",
633
+ "moduleName" : "ROHC-MIB",
634
+ "oid" : "1.3.6.1.2.1.112.1.1.2.1.18",
635
+ "status" : "current",
636
+ "syntax" : {
637
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
638
+ },
639
+ "access" : "readonly",
640
+ "description" :
641
+ """The number of all IR-DYN packets that are either sent
642
+ or received by this instance.
643
+
644
+ Discontinuities in the value of this counter can
645
+ occur at re-initialization of the management
646
+ system, and at other times as indicated by the
647
+ value of ifCounterDiscontinuityTime.""",
648
+ "reference" :
649
+ """RFC 3095, Section 5.7.7.2""",
650
+ }, # column
651
+ "rohcInstanceFeedbacks" : {
652
+ "nodetype" : "column",
653
+ "moduleName" : "ROHC-MIB",
654
+ "oid" : "1.3.6.1.2.1.112.1.1.2.1.19",
655
+ "status" : "current",
656
+ "syntax" : {
657
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
658
+ },
659
+ "access" : "readonly",
660
+ "description" :
661
+ """The number of all feedbacks that are either sent
662
+ or received by this instance.
663
+
664
+ Discontinuities in the value of this counter can
665
+ occur at re-initialization of the management
666
+ system, and at other times as indicated by the
667
+ value of ifCounterDiscontinuityTime.""",
668
+ }, # column
669
+ "rohcInstanceCompressionRatio" : {
670
+ "nodetype" : "column",
671
+ "moduleName" : "ROHC-MIB",
672
+ "oid" : "1.3.6.1.2.1.112.1.1.2.1.20",
673
+ "status" : "current",
674
+ "syntax" : {
675
+ "type" : { "module" :"ROHC-MIB", "name" : "RohcCompressionRatio"},
676
+ },
677
+ "access" : "readonly",
678
+ "description" :
679
+ """This object indicates the compression ratio so far over all
680
+ packets on the channel served by this instance. The
681
+ compression is computed over all bytes of the IP packets
682
+ including the IP header but excluding all lower layer
683
+ headers.""",
684
+ }, # column
685
+ "rohcProfileTable" : {
686
+ "nodetype" : "table",
687
+ "moduleName" : "ROHC-MIB",
688
+ "oid" : "1.3.6.1.2.1.112.1.1.3",
689
+ "status" : "current",
690
+ "description" :
691
+ """This table lists a set of profiles supported by the
692
+ instance.""",
693
+ "reference" :
694
+ """RFC 3095, Section 5.1.1""",
695
+ }, # table
696
+ "rohcProfileEntry" : {
697
+ "nodetype" : "row",
698
+ "moduleName" : "ROHC-MIB",
699
+ "oid" : "1.3.6.1.2.1.112.1.1.3.1",
700
+ "status" : "current",
701
+ "linkage" : [
702
+ "rohcChannelID",
703
+ "rohcProfile",
704
+ ],
705
+ "description" :
706
+ """An entry describing a particular profile supported by
707
+ the instance. It is indexed by the rohcChannelID
708
+ identifying the instance and by the rohcProfile.""",
709
+ }, # row
710
+ "rohcProfile" : {
711
+ "nodetype" : "column",
712
+ "moduleName" : "ROHC-MIB",
713
+ "oid" : "1.3.6.1.2.1.112.1.1.3.1.2",
714
+ "status" : "current",
715
+ "syntax" : {
716
+ "type" : {
717
+ "basetype" : "Unsigned32",
718
+ "ranges" : [
719
+ {
720
+ "min" : "0",
721
+ "max" : "65535"
722
+ },
723
+ ],
724
+ "range" : {
725
+ "min" : "0",
726
+ "max" : "65535"
727
+ },
728
+ },
729
+ },
730
+ "access" : "noaccess",
731
+ "description" :
732
+ """Identifier of a profile supported. For a listing of
733
+ possible profile values, see the IANA registry for
734
+ 'RObust Header Compression (ROHC) Profile Identifiers'
735
+ at http://www.iana.org/assignments/rohc-pro-ids""",
736
+ }, # column
737
+ "rohcProfileVendor" : {
738
+ "nodetype" : "column",
739
+ "moduleName" : "ROHC-MIB",
740
+ "oid" : "1.3.6.1.2.1.112.1.1.3.1.3",
741
+ "status" : "current",
742
+ "syntax" : {
743
+ "type" : { "module" :"", "name" : "ObjectIdentifier"},
744
+ },
745
+ "access" : "readonly",
746
+ "description" :
747
+ """An object identifier that identifies the vendor who
748
+ provides the implementation of robust header description.
749
+ This object identifier SHALL point to the object identifier
750
+ directly below the enterprise object identifier
751
+ {1 3 6 1 4 1} allocated for the vendor. The value must be
752
+ the object identifier {0 0} if the vendor is not known.""",
753
+ }, # column
754
+ "rohcProfileVersion" : {
755
+ "nodetype" : "column",
756
+ "moduleName" : "ROHC-MIB",
757
+ "oid" : "1.3.6.1.2.1.112.1.1.3.1.4",
758
+ "status" : "current",
759
+ "syntax" : {
760
+ "type" : {
761
+ "basetype" : "OctetString",
762
+ "parent module" : {
763
+ "name" : "SNMP-FRAMEWORK-MIB",
764
+ "type" : "SnmpAdminString",
765
+ },
766
+ "ranges" : [
767
+ {
768
+ "min" : "0",
769
+ "max" : "32"
770
+ },
771
+ ],
772
+ "range" : {
773
+ "min" : "0",
774
+ "max" : "32"
775
+ },
776
+ },
777
+ },
778
+ "access" : "readonly",
779
+ "description" :
780
+ """The version number of the implementation of robust header
781
+ compression. The zero-length string shall be used if the
782
+ implementation does not have a version number.
783
+
784
+ It is suggested that the version number consist of one or
785
+ more decimal numbers separated by dots, where the first
786
+ number is called the major version number.""",
787
+ }, # column
788
+ "rohcProfileDescr" : {
789
+ "nodetype" : "column",
790
+ "moduleName" : "ROHC-MIB",
791
+ "oid" : "1.3.6.1.2.1.112.1.1.3.1.5",
792
+ "status" : "current",
793
+ "syntax" : {
794
+ "type" : { "module" :"SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
795
+ },
796
+ "access" : "readonly",
797
+ "description" :
798
+ """A textual description of the implementation.""",
799
+ }, # column
800
+ "rohcProfileNegotiated" : {
801
+ "nodetype" : "column",
802
+ "moduleName" : "ROHC-MIB",
803
+ "oid" : "1.3.6.1.2.1.112.1.1.3.1.6",
804
+ "status" : "current",
805
+ "syntax" : {
806
+ "type" : { "module" :"SNMPv2-TC", "name" : "TruthValue"},
807
+ },
808
+ "access" : "readonly",
809
+ "description" :
810
+ """When retrieved, this boolean object returns true
811
+ if the profile has been negotiated to be used at
812
+ the instance, i.e., is supported also be the
813
+ corresponding compressor/decompressor.""",
814
+ }, # column
815
+ "rohcContextTable" : {
816
+ "nodetype" : "table",
817
+ "moduleName" : "ROHC-MIB",
818
+ "oid" : "1.3.6.1.2.1.112.1.2",
819
+ "status" : "current",
820
+ "description" :
821
+ """This table lists and describes all compressor contexts
822
+ per instance.""",
823
+ }, # table
824
+ "rohcContextEntry" : {
825
+ "nodetype" : "row",
826
+ "moduleName" : "ROHC-MIB",
827
+ "oid" : "1.3.6.1.2.1.112.1.2.1",
828
+ "status" : "current",
829
+ "linkage" : [
830
+ "rohcChannelID",
831
+ "rohcContextCID",
832
+ ],
833
+ "description" :
834
+ """An entry describing a particular compressor context.""",
835
+ }, # row
836
+ "rohcContextCID" : {
837
+ "nodetype" : "column",
838
+ "moduleName" : "ROHC-MIB",
839
+ "oid" : "1.3.6.1.2.1.112.1.2.1.2",
840
+ "status" : "current",
841
+ "syntax" : {
842
+ "type" : {
843
+ "basetype" : "Unsigned32",
844
+ "ranges" : [
845
+ {
846
+ "min" : "0",
847
+ "max" : "16383"
848
+ },
849
+ ],
850
+ "range" : {
851
+ "min" : "0",
852
+ "max" : "16383"
853
+ },
854
+ },
855
+ },
856
+ "access" : "noaccess",
857
+ "description" :
858
+ """The context identifier (CID) of this context.""",
859
+ "reference" :
860
+ """RFC 3095, Sections 5.1.1 and 5.1.3""",
861
+ }, # column
862
+ "rohcContextCIDState" : {
863
+ "nodetype" : "column",
864
+ "moduleName" : "ROHC-MIB",
865
+ "oid" : "1.3.6.1.2.1.112.1.2.1.3",
866
+ "status" : "current",
867
+ "syntax" : {
868
+ "type" : {
869
+ "basetype" : "Enumeration",
870
+ "unused" : {
871
+ "nodetype" : "namednumber",
872
+ "number" : "1"
873
+ },
874
+ "active" : {
875
+ "nodetype" : "namednumber",
876
+ "number" : "2"
877
+ },
878
+ "expired" : {
879
+ "nodetype" : "namednumber",
880
+ "number" : "3"
881
+ },
882
+ "terminated" : {
883
+ "nodetype" : "namednumber",
884
+ "number" : "4"
885
+ },
886
+ },
887
+ },
888
+ "access" : "readonly",
889
+ "description" :
890
+ """State of the CID. When a CID is assigned to a context,
891
+ its state changes from `unused' to `active'. The active
892
+ context may stop operation due to some explicit
893
+ signalling or after observing no packet for some specified
894
+ time. In the first case then the CID state changes to
895
+ `terminated', in the latter case it changes to `expired'.
896
+ If the CID is re-used again for another context, the
897
+ state changes back to `active'.""",
898
+ }, # column
899
+ "rohcContextProfile" : {
900
+ "nodetype" : "column",
901
+ "moduleName" : "ROHC-MIB",
902
+ "oid" : "1.3.6.1.2.1.112.1.2.1.4",
903
+ "status" : "current",
904
+ "syntax" : {
905
+ "type" : {
906
+ "basetype" : "Unsigned32",
907
+ "ranges" : [
908
+ {
909
+ "min" : "0",
910
+ "max" : "65535"
911
+ },
912
+ ],
913
+ "range" : {
914
+ "min" : "0",
915
+ "max" : "65535"
916
+ },
917
+ },
918
+ },
919
+ "access" : "readonly",
920
+ "description" :
921
+ """Identifier of the profile for this context.
922
+ The profile is identified by its index in the
923
+ rohcProfileTable for this instance. There MUST exist a
924
+ corresponding entry in the rohcProfileTable using the
925
+ value of rohcContextProfile as second part of the index
926
+ (and using the same rohcChannelID as first part of the
927
+ index).""",
928
+ }, # column
929
+ "rohcContextDecompressorDepth" : {
930
+ "nodetype" : "column",
931
+ "moduleName" : "ROHC-MIB",
932
+ "oid" : "1.3.6.1.2.1.112.1.2.1.5",
933
+ "status" : "current",
934
+ "syntax" : {
935
+ "type" : { "module" :"", "name" : "Unsigned32"},
936
+ },
937
+ "access" : "readonly",
938
+ "description" :
939
+ """This object indicates whether reverse decompression, for
940
+ example as described in RFC 3095, Section 6.1, is used
941
+ on this channel or not, and if used, to what extent.
942
+
943
+
944
+
945
+
946
+ Its value is only valid for decompressor contexts, i.e.,
947
+ if rohcInstanceType has the value decompressor(2). For
948
+ compressor contexts where rohcInstanceType has the value
949
+ compressor(1), the value of this object is irrelevant
950
+ and MUST be set to zero (0).
951
+
952
+ The value of the reverse decompression depth indicates
953
+ the maximum number of packets that are buffered, and thus
954
+ possibly be reverse decompressed by the decompressor.
955
+ A zero (0) value means that reverse decompression is not
956
+ used.""",
957
+ }, # column
958
+ "rohcContextStorageTime" : {
959
+ "nodetype" : "column",
960
+ "moduleName" : "ROHC-MIB",
961
+ "oid" : "1.3.6.1.2.1.112.1.2.1.6",
962
+ "status" : "current",
963
+ "syntax" : {
964
+ "type" : { "module" :"SNMPv2-TC", "name" : "TimeInterval"},
965
+ },
966
+ "access" : "readwrite",
967
+ "units" : "centi-seconds",
968
+ "description" :
969
+ """The value of this object specifies how long this row
970
+ can exist in the rohcContextTable after the
971
+ rohcContextCIDState switched to expired(3) or
972
+ terminated(4). This object returns the remaining time
973
+ that the row may exist before it is aged out. The object
974
+ is initialized with the value of the associated
975
+ rohcContextStorageTime object. After expiration or
976
+ termination of the context, the value of this object ticks
977
+ backwards. The entry in the rohcContextTable is destroyed
978
+ when the value reaches 0.
979
+
980
+ The value of this object may be set in order to increase or
981
+ reduce the remaining time that the row may exist. Setting
982
+ the value to 0 will destroy this entry as soon as the
983
+ rochContextCIDState has the value expired(3) or
984
+ terminated(4).
985
+
986
+ Note that there is no guarantee that the row is stored as
987
+ long as this object indicates. In case of limited CID
988
+ space, the instance may re-use a CID before the storage
989
+ time of the corresponding row in rohcContextTable reaches
990
+ the value of 0. In this case the information stored in this
991
+ row is not anymore available.""",
992
+ }, # column
993
+ "rohcContextActivationTime" : {
994
+ "nodetype" : "column",
995
+ "moduleName" : "ROHC-MIB",
996
+ "oid" : "1.3.6.1.2.1.112.1.2.1.7",
997
+ "status" : "current",
998
+ "syntax" : {
999
+ "type" : { "module" :"SNMPv2-TC", "name" : "DateAndTime"},
1000
+ },
1001
+ "access" : "readonly",
1002
+ "default" : "0x0000000000000000",
1003
+ "description" :
1004
+ """The date and time when the context started to be able to
1005
+ compress packets or decompress packets, respectively.
1006
+ The value '0000000000000000'H is returned if the context
1007
+ has not been activated yet.""",
1008
+ }, # column
1009
+ "rohcContextDeactivationTime" : {
1010
+ "nodetype" : "column",
1011
+ "moduleName" : "ROHC-MIB",
1012
+ "oid" : "1.3.6.1.2.1.112.1.2.1.8",
1013
+ "status" : "current",
1014
+ "syntax" : {
1015
+ "type" : { "module" :"SNMPv2-TC", "name" : "DateAndTime"},
1016
+ },
1017
+ "access" : "readonly",
1018
+ "default" : "0x0000000000000000",
1019
+ "description" :
1020
+ """The date and time when the context stopped being able to
1021
+ compress packets or decompress packets, respectively,
1022
+ because it expired or was terminated for other reasons.
1023
+ The value '0000000000000000'H is returned if the context
1024
+ has not been deactivated yet.""",
1025
+ }, # column
1026
+ "rohcContextPackets" : {
1027
+ "nodetype" : "column",
1028
+ "moduleName" : "ROHC-MIB",
1029
+ "oid" : "1.3.6.1.2.1.112.1.2.1.9",
1030
+ "status" : "current",
1031
+ "syntax" : {
1032
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1033
+ },
1034
+ "access" : "readonly",
1035
+ "description" :
1036
+ """The number of all packets passing this context.
1037
+
1038
+ Discontinuities in the value of this counter can
1039
+ occur at re-initialization of the management
1040
+ system, and at other times as indicated by the
1041
+ value of ifCounterDiscontinuityTime. For checking
1042
+ ifCounterDiscontinuityTime, the interface index is
1043
+ required. It can be determined by reading the
1044
+ rohcChannelTable.""",
1045
+ }, # column
1046
+ "rohcContextIRs" : {
1047
+ "nodetype" : "column",
1048
+ "moduleName" : "ROHC-MIB",
1049
+ "oid" : "1.3.6.1.2.1.112.1.2.1.10",
1050
+ "status" : "current",
1051
+ "syntax" : {
1052
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1053
+ },
1054
+ "access" : "readonly",
1055
+ "description" :
1056
+ """The number of all IR packets sent or received,
1057
+ respectively, by this context.
1058
+
1059
+ Discontinuities in the value of this counter can
1060
+ occur at re-initialization of the management
1061
+ system, and at other times as indicated by the
1062
+
1063
+
1064
+
1065
+ value of ifCounterDiscontinuityTime. For checking
1066
+ ifCounterDiscontinuityTime, the interface index is
1067
+ required. It can be determined by reading the
1068
+ rohcChannelTable.""",
1069
+ "reference" :
1070
+ """RFC 3095, Section 5.7.7.1""",
1071
+ }, # column
1072
+ "rohcContextIRDYNs" : {
1073
+ "nodetype" : "column",
1074
+ "moduleName" : "ROHC-MIB",
1075
+ "oid" : "1.3.6.1.2.1.112.1.2.1.11",
1076
+ "status" : "current",
1077
+ "syntax" : {
1078
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1079
+ },
1080
+ "access" : "readonly",
1081
+ "description" :
1082
+ """The number of all IR-DYN packets sent or received,
1083
+ respectively, by this context.
1084
+
1085
+ Discontinuities in the value of this counter can
1086
+ occur at re-initialization of the management
1087
+ system, and at other times as indicated by the
1088
+ value of ifCounterDiscontinuityTime. For checking
1089
+ ifCounterDiscontinuityTime, the interface index is
1090
+ required. It can be determined by reading the
1091
+ rohcChannelTable.""",
1092
+ "reference" :
1093
+ """RFC 3095, Section 5.7.7.2""",
1094
+ }, # column
1095
+ "rohcContextFeedbacks" : {
1096
+ "nodetype" : "column",
1097
+ "moduleName" : "ROHC-MIB",
1098
+ "oid" : "1.3.6.1.2.1.112.1.2.1.12",
1099
+ "status" : "current",
1100
+ "syntax" : {
1101
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1102
+ },
1103
+ "access" : "readonly",
1104
+ "description" :
1105
+ """The number of all feedbacks sent or received,
1106
+ respectively, by this context.
1107
+
1108
+ Discontinuities in the value of this counter can
1109
+ occur at re-initialization of the management
1110
+ system, and at other times as indicated by the
1111
+ value of ifCounterDiscontinuityTime. For checking
1112
+ ifCounterDiscontinuityTime, the interface index is
1113
+ required. It can be determined by reading the
1114
+ rohcChannelTable.""",
1115
+ }, # column
1116
+ "rohcContextDecompressorFailures" : {
1117
+ "nodetype" : "column",
1118
+ "moduleName" : "ROHC-MIB",
1119
+ "oid" : "1.3.6.1.2.1.112.1.2.1.13",
1120
+ "status" : "current",
1121
+ "syntax" : {
1122
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1123
+ },
1124
+ "access" : "readonly",
1125
+ "description" :
1126
+ """The number of all decompressor failures so far in this
1127
+ context. The number is only valid for decompressor
1128
+ contexts, i.e., if rohcInstanceType has the value
1129
+ decompressor(2).
1130
+
1131
+ Discontinuities in the value of this counter can
1132
+ occur at re-initialization of the management
1133
+ system, and at other times as indicated by the
1134
+ value of ifCounterDiscontinuityTime. For checking
1135
+ ifCounterDiscontinuityTime, the interface index is
1136
+ required. It can be determined by reading the
1137
+ rohcChannelTable.""",
1138
+ }, # column
1139
+ "rohcContextDecompressorRepairs" : {
1140
+ "nodetype" : "column",
1141
+ "moduleName" : "ROHC-MIB",
1142
+ "oid" : "1.3.6.1.2.1.112.1.2.1.14",
1143
+ "status" : "current",
1144
+ "syntax" : {
1145
+ "type" : { "module" :"SNMPv2-SMI", "name" : "Counter32"},
1146
+ },
1147
+ "access" : "readonly",
1148
+ "description" :
1149
+ """The number of all context repairs so far in this
1150
+ context. The number is only valid for decompressor
1151
+ contexts, i.e., if rohcInstanceType has the value
1152
+ decompressor(2).
1153
+
1154
+ Discontinuities in the value of this counter can
1155
+ occur at re-initialization of the management
1156
+ system, and at other times as indicated by the
1157
+ value of ifCounterDiscontinuityTime. For checking
1158
+ ifCounterDiscontinuityTime, the interface index is
1159
+ required. It can be determined by reading the
1160
+ rohcChannelTable.""",
1161
+ }, # column
1162
+ "rohcContextAllPacketsRatio" : {
1163
+ "nodetype" : "column",
1164
+ "moduleName" : "ROHC-MIB",
1165
+ "oid" : "1.3.6.1.2.1.112.1.2.1.15",
1166
+ "status" : "current",
1167
+ "syntax" : {
1168
+ "type" : { "module" :"ROHC-MIB", "name" : "RohcCompressionRatio"},
1169
+ },
1170
+ "access" : "readonly",
1171
+ "description" :
1172
+ """This object indicates the compression ratio so far over all
1173
+ packets passing this context. The compression is computed
1174
+ over all bytes of the IP packets including the IP header
1175
+ but excluding all lower layer headers.""",
1176
+ }, # column
1177
+ "rohcContextAllHeadersRatio" : {
1178
+ "nodetype" : "column",
1179
+ "moduleName" : "ROHC-MIB",
1180
+ "oid" : "1.3.6.1.2.1.112.1.2.1.16",
1181
+ "status" : "current",
1182
+ "syntax" : {
1183
+ "type" : { "module" :"ROHC-MIB", "name" : "RohcCompressionRatio"},
1184
+ },
1185
+ "access" : "readonly",
1186
+ "description" :
1187
+ """This object indicates the compression ratio so far over all
1188
+ packet headers passing this context. The compression is
1189
+ computed over all bytes of all headers that are subject to
1190
+ compression for the used profile.""",
1191
+ }, # column
1192
+ "rohcContextAllPacketsMeanSize" : {
1193
+ "nodetype" : "column",
1194
+ "moduleName" : "ROHC-MIB",
1195
+ "oid" : "1.3.6.1.2.1.112.1.2.1.17",
1196
+ "status" : "current",
1197
+ "syntax" : {
1198
+ "type" : { "module" :"", "name" : "Unsigned32"},
1199
+ },
1200
+ "access" : "readonly",
1201
+ "description" :
1202
+ """This object indicates the mean compressed packet size
1203
+ of all packets passing this context. The packet size
1204
+ includes the IP header and payload but excludes all lower
1205
+ layer headers. The mean value is given in byte rounded
1206
+ to the next integer value.""",
1207
+ }, # column
1208
+ "rohcContextAllHeadersMeanSize" : {
1209
+ "nodetype" : "column",
1210
+ "moduleName" : "ROHC-MIB",
1211
+ "oid" : "1.3.6.1.2.1.112.1.2.1.18",
1212
+ "status" : "current",
1213
+ "syntax" : {
1214
+ "type" : { "module" :"", "name" : "Unsigned32"},
1215
+ },
1216
+ "access" : "readonly",
1217
+ "description" :
1218
+ """This object indicates the mean compressed packet header size
1219
+ of all packets passing this context. The packet header size
1220
+ is the sum of the size of all headers of a packet that are
1221
+ subject to compression for the used profile. The mean value
1222
+ is given in byte rounded to the next integer value.""",
1223
+ }, # column
1224
+ "rohcContextLastPacketsRatio" : {
1225
+ "nodetype" : "column",
1226
+ "moduleName" : "ROHC-MIB",
1227
+ "oid" : "1.3.6.1.2.1.112.1.2.1.19",
1228
+ "status" : "current",
1229
+ "syntax" : {
1230
+ "type" : { "module" :"ROHC-MIB", "name" : "RohcCompressionRatio"},
1231
+ },
1232
+ "access" : "readonly",
1233
+ "description" :
1234
+ """This object indicates the compression ratio
1235
+ concerning the last 16 packets passing this context
1236
+ or concerning all packets passing this context
1237
+ if they are less than 16, so far. The compression is
1238
+ computed over all bytes of the IP packets including the IP
1239
+ header but excluding all lower layer headers.""",
1240
+ }, # column
1241
+ "rohcContextLastHeadersRatio" : {
1242
+ "nodetype" : "column",
1243
+ "moduleName" : "ROHC-MIB",
1244
+ "oid" : "1.3.6.1.2.1.112.1.2.1.20",
1245
+ "status" : "current",
1246
+ "syntax" : {
1247
+ "type" : { "module" :"ROHC-MIB", "name" : "RohcCompressionRatio"},
1248
+ },
1249
+ "access" : "readonly",
1250
+ "description" :
1251
+ """This object indicates the compression ratio concerning the
1252
+ headers of the last 16 packets passing this context or
1253
+ concerning the headers of all packets passing this context
1254
+ if they are less than 16, so far. The compression is
1255
+ computed over all bytes of all headers that are subject to
1256
+ compression for the used profile.""",
1257
+ }, # column
1258
+ "rohcContextLastPacketsMeanSize" : {
1259
+ "nodetype" : "column",
1260
+ "moduleName" : "ROHC-MIB",
1261
+ "oid" : "1.3.6.1.2.1.112.1.2.1.21",
1262
+ "status" : "current",
1263
+ "syntax" : {
1264
+ "type" : { "module" :"", "name" : "Unsigned32"},
1265
+ },
1266
+ "access" : "readonly",
1267
+ "description" :
1268
+ """This object indicates the mean compressed packet size
1269
+ concerning the last 16 packets passing this context or
1270
+ concerning all packets passing this context if they are
1271
+ less than 16, so far. The packet size includes the IP
1272
+ header and payload but excludes all lower layer headers.
1273
+ The mean value is given in byte rounded to the next
1274
+ integer value.""",
1275
+ }, # column
1276
+ "rohcContextLastHeadersMeanSize" : {
1277
+ "nodetype" : "column",
1278
+ "moduleName" : "ROHC-MIB",
1279
+ "oid" : "1.3.6.1.2.1.112.1.2.1.22",
1280
+ "status" : "current",
1281
+ "syntax" : {
1282
+ "type" : { "module" :"", "name" : "Unsigned32"},
1283
+ },
1284
+ "access" : "readonly",
1285
+ "description" :
1286
+ """This object indicates the mean compressed packet header size
1287
+ concerning the last 16 packets passing this context or
1288
+ concerning all packets passing this context if they are
1289
+ less than 16, so far. The packet header size is the sum of
1290
+ the size of all headers of a packet that are subject to
1291
+ compression for the used profile. The mean value is given
1292
+ in byte rounded to the next integer value.""",
1293
+ }, # column
1294
+ "rohcConformance" : {
1295
+ "nodetype" : "node",
1296
+ "moduleName" : "ROHC-MIB",
1297
+ "oid" : "1.3.6.1.2.1.112.2",
1298
+ }, # node
1299
+ "rohcCompliances" : {
1300
+ "nodetype" : "node",
1301
+ "moduleName" : "ROHC-MIB",
1302
+ "oid" : "1.3.6.1.2.1.112.2.1",
1303
+ }, # node
1304
+ "rohcGroups" : {
1305
+ "nodetype" : "node",
1306
+ "moduleName" : "ROHC-MIB",
1307
+ "oid" : "1.3.6.1.2.1.112.2.2",
1308
+ }, # node
1309
+ }, # nodes
1310
+
1311
+ "groups" : {
1312
+ "rohcInstanceGroup" : {
1313
+ "nodetype" : "group",
1314
+ "moduleName" : "ROHC-MIB",
1315
+ "oid" : "1.3.6.1.2.1.112.2.2.2",
1316
+ "status" : "current",
1317
+ "members" : {
1318
+ "rohcChannelType" : {
1319
+ "nodetype" : "member",
1320
+ "module" : "ROHC-MIB"
1321
+ },
1322
+ "rohcChannelFeedbackFor" : {
1323
+ "nodetype" : "member",
1324
+ "module" : "ROHC-MIB"
1325
+ },
1326
+ "rohcChannelDescr" : {
1327
+ "nodetype" : "member",
1328
+ "module" : "ROHC-MIB"
1329
+ },
1330
+ "rohcChannelStatus" : {
1331
+ "nodetype" : "member",
1332
+ "module" : "ROHC-MIB"
1333
+ },
1334
+ "rohcInstanceFBChannelID" : {
1335
+ "nodetype" : "member",
1336
+ "module" : "ROHC-MIB"
1337
+ },
1338
+ "rohcInstanceVendor" : {
1339
+ "nodetype" : "member",
1340
+ "module" : "ROHC-MIB"
1341
+ },
1342
+ "rohcInstanceVersion" : {
1343
+ "nodetype" : "member",
1344
+ "module" : "ROHC-MIB"
1345
+ },
1346
+ "rohcInstanceDescr" : {
1347
+ "nodetype" : "member",
1348
+ "module" : "ROHC-MIB"
1349
+ },
1350
+ "rohcInstanceClockRes" : {
1351
+ "nodetype" : "member",
1352
+ "module" : "ROHC-MIB"
1353
+ },
1354
+ "rohcInstanceMaxCID" : {
1355
+ "nodetype" : "member",
1356
+ "module" : "ROHC-MIB"
1357
+ },
1358
+ "rohcInstanceLargeCIDs" : {
1359
+ "nodetype" : "member",
1360
+ "module" : "ROHC-MIB"
1361
+ },
1362
+ "rohcInstanceMRRU" : {
1363
+ "nodetype" : "member",
1364
+ "module" : "ROHC-MIB"
1365
+ },
1366
+ "rohcInstanceStatus" : {
1367
+ "nodetype" : "member",
1368
+ "module" : "ROHC-MIB"
1369
+ },
1370
+ "rohcProfileVendor" : {
1371
+ "nodetype" : "member",
1372
+ "module" : "ROHC-MIB"
1373
+ },
1374
+ "rohcProfileVersion" : {
1375
+ "nodetype" : "member",
1376
+ "module" : "ROHC-MIB"
1377
+ },
1378
+ "rohcProfileDescr" : {
1379
+ "nodetype" : "member",
1380
+ "module" : "ROHC-MIB"
1381
+ },
1382
+ "rohcProfileNegotiated" : {
1383
+ "nodetype" : "member",
1384
+ "module" : "ROHC-MIB"
1385
+ },
1386
+ }, # members
1387
+ "description" :
1388
+ """A collection of objects providing information about
1389
+ ROHC instances, used channels and available profiles.""",
1390
+ }, # group
1391
+ "rohcStatisticsGroup" : {
1392
+ "nodetype" : "group",
1393
+ "moduleName" : "ROHC-MIB",
1394
+ "oid" : "1.3.6.1.2.1.112.2.2.4",
1395
+ "status" : "current",
1396
+ "members" : {
1397
+ "rohcInstanceContextsTotal" : {
1398
+ "nodetype" : "member",
1399
+ "module" : "ROHC-MIB"
1400
+ },
1401
+ "rohcInstanceContextsCurrent" : {
1402
+ "nodetype" : "member",
1403
+ "module" : "ROHC-MIB"
1404
+ },
1405
+ "rohcInstancePackets" : {
1406
+ "nodetype" : "member",
1407
+ "module" : "ROHC-MIB"
1408
+ },
1409
+ "rohcInstanceIRs" : {
1410
+ "nodetype" : "member",
1411
+ "module" : "ROHC-MIB"
1412
+ },
1413
+ "rohcInstanceIRDYNs" : {
1414
+ "nodetype" : "member",
1415
+ "module" : "ROHC-MIB"
1416
+ },
1417
+ "rohcInstanceFeedbacks" : {
1418
+ "nodetype" : "member",
1419
+ "module" : "ROHC-MIB"
1420
+ },
1421
+ "rohcInstanceCompressionRatio" : {
1422
+ "nodetype" : "member",
1423
+ "module" : "ROHC-MIB"
1424
+ },
1425
+ }, # members
1426
+ "description" :
1427
+ """A collection of objects providing ROHC statistics.""",
1428
+ }, # group
1429
+ "rohcContextGroup" : {
1430
+ "nodetype" : "group",
1431
+ "moduleName" : "ROHC-MIB",
1432
+ "oid" : "1.3.6.1.2.1.112.2.2.5",
1433
+ "status" : "current",
1434
+ "members" : {
1435
+ "rohcContextCIDState" : {
1436
+ "nodetype" : "member",
1437
+ "module" : "ROHC-MIB"
1438
+ },
1439
+ "rohcContextProfile" : {
1440
+ "nodetype" : "member",
1441
+ "module" : "ROHC-MIB"
1442
+ },
1443
+ "rohcContextDecompressorDepth" : {
1444
+ "nodetype" : "member",
1445
+ "module" : "ROHC-MIB"
1446
+ },
1447
+ }, # members
1448
+ "description" :
1449
+ """A collection of objects providing information about
1450
+ ROHC compressor contexts and decompressor contexts.""",
1451
+ }, # group
1452
+ "rohcTimerGroup" : {
1453
+ "nodetype" : "group",
1454
+ "moduleName" : "ROHC-MIB",
1455
+ "oid" : "1.3.6.1.2.1.112.2.2.6",
1456
+ "status" : "current",
1457
+ "members" : {
1458
+ "rohcInstanceContextStorageTime" : {
1459
+ "nodetype" : "member",
1460
+ "module" : "ROHC-MIB"
1461
+ },
1462
+ "rohcContextStorageTime" : {
1463
+ "nodetype" : "member",
1464
+ "module" : "ROHC-MIB"
1465
+ },
1466
+ "rohcContextActivationTime" : {
1467
+ "nodetype" : "member",
1468
+ "module" : "ROHC-MIB"
1469
+ },
1470
+ "rohcContextDeactivationTime" : {
1471
+ "nodetype" : "member",
1472
+ "module" : "ROHC-MIB"
1473
+ },
1474
+ }, # members
1475
+ "description" :
1476
+ """A collection of objects providing statistical information
1477
+ about ROHC compressor contexts and decompressor contexts.""",
1478
+ }, # group
1479
+ "rohcContextStatisticsGroup" : {
1480
+ "nodetype" : "group",
1481
+ "moduleName" : "ROHC-MIB",
1482
+ "oid" : "1.3.6.1.2.1.112.2.2.7",
1483
+ "status" : "current",
1484
+ "members" : {
1485
+ "rohcContextPackets" : {
1486
+ "nodetype" : "member",
1487
+ "module" : "ROHC-MIB"
1488
+ },
1489
+ "rohcContextIRs" : {
1490
+ "nodetype" : "member",
1491
+ "module" : "ROHC-MIB"
1492
+ },
1493
+ "rohcContextIRDYNs" : {
1494
+ "nodetype" : "member",
1495
+ "module" : "ROHC-MIB"
1496
+ },
1497
+ "rohcContextFeedbacks" : {
1498
+ "nodetype" : "member",
1499
+ "module" : "ROHC-MIB"
1500
+ },
1501
+ "rohcContextDecompressorFailures" : {
1502
+ "nodetype" : "member",
1503
+ "module" : "ROHC-MIB"
1504
+ },
1505
+ "rohcContextDecompressorRepairs" : {
1506
+ "nodetype" : "member",
1507
+ "module" : "ROHC-MIB"
1508
+ },
1509
+ "rohcContextAllPacketsRatio" : {
1510
+ "nodetype" : "member",
1511
+ "module" : "ROHC-MIB"
1512
+ },
1513
+ "rohcContextAllHeadersRatio" : {
1514
+ "nodetype" : "member",
1515
+ "module" : "ROHC-MIB"
1516
+ },
1517
+ "rohcContextAllPacketsMeanSize" : {
1518
+ "nodetype" : "member",
1519
+ "module" : "ROHC-MIB"
1520
+ },
1521
+ "rohcContextAllHeadersMeanSize" : {
1522
+ "nodetype" : "member",
1523
+ "module" : "ROHC-MIB"
1524
+ },
1525
+ "rohcContextLastPacketsRatio" : {
1526
+ "nodetype" : "member",
1527
+ "module" : "ROHC-MIB"
1528
+ },
1529
+ "rohcContextLastHeadersRatio" : {
1530
+ "nodetype" : "member",
1531
+ "module" : "ROHC-MIB"
1532
+ },
1533
+ "rohcContextLastPacketsMeanSize" : {
1534
+ "nodetype" : "member",
1535
+ "module" : "ROHC-MIB"
1536
+ },
1537
+ "rohcContextLastHeadersMeanSize" : {
1538
+ "nodetype" : "member",
1539
+ "module" : "ROHC-MIB"
1540
+ },
1541
+ }, # members
1542
+ "description" :
1543
+ """A collection of objects providing statistical information
1544
+ about ROHC compressor contexts and decompressor contexts.""",
1545
+ }, # group
1546
+ }, # groups
1547
+
1548
+ "compliances" : {
1549
+ "rohcCompliance" : {
1550
+ "nodetype" : "compliance",
1551
+ "moduleName" : "ROHC-MIB",
1552
+ "oid" : "1.3.6.1.2.1.112.2.1.1",
1553
+ "status" : "current",
1554
+ "description" :
1555
+ """The compliance statement for SNMP entities that implement
1556
+ the ROHC-MIB.
1557
+
1558
+ Note that compliance with this compliance
1559
+ statement requires compliance with the
1560
+ ifCompliance3 MODULE-COMPLIANCE statement of the
1561
+ IF-MIB (RFC2863).""",
1562
+ "requires" : {
1563
+ "rohcInstanceGroup" : {
1564
+ "nodetype" : "mandatory",
1565
+ "module" : "ROHC-MIB"
1566
+ },
1567
+ "rohcContextGroup" : {
1568
+ "nodetype" : "mandatory",
1569
+ "module" : "ROHC-MIB"
1570
+ },
1571
+ "rohcStatisticsGroup" : {
1572
+ "nodetype" : "optional",
1573
+ "module" : "ROHC-MIB",
1574
+ "description" :
1575
+ """A compliant implementation does not have to implement
1576
+ the rohcStatisticsGroup.""",
1577
+ },
1578
+ "rohcTimerGroup" : {
1579
+ "nodetype" : "optional",
1580
+ "module" : "ROHC-MIB",
1581
+ "description" :
1582
+ """A compliant implementation does not have to implement
1583
+ the rohcTimerGroup.""",
1584
+ },
1585
+ "rohcContextStatisticsGroup" : {
1586
+ "nodetype" : "optional",
1587
+ "module" : "ROHC-MIB",
1588
+ "description" :
1589
+ """A compliant implementation does not have to implement
1590
+ the rohcContextStatisticsGroup.""",
1591
+ },
1592
+ }, # requires
1593
+ "refinements" : {
1594
+ "rohcInstanceContextStorageTime" : {
1595
+ "module" : "ROHC-MIB",
1596
+ "access" : "readonly",
1597
+ "description" :
1598
+ """A compliant implementation does not have to support changing
1599
+ the value of object rohcInstanceContextStorageTime.""",
1600
+ },
1601
+ "rohcContextStorageTime" : {
1602
+ "module" : "ROHC-MIB",
1603
+ "access" : "readonly",
1604
+ "description" :
1605
+ """A compliant implementation does not have to support changing
1606
+ the value of object rohcContextStorageTime.""",
1607
+ },
1608
+ }, # refinements
1609
+
1610
+ }, # compliance
1611
+ }, # compliances
1612
+
1613
+ }