logstash-input-snmp 0.1.0.beta4 → 0.1.0.beta5

Sign up to get free protection for your applications and to get access to all the features.
Files changed (309) hide show
  1. checksums.yaml +4 -4
  2. data/CHANGELOG.md +5 -0
  3. data/lib/logstash/inputs/snmp.rb +75 -12
  4. data/lib/logstash/inputs/snmp/base_client.rb +162 -0
  5. data/lib/logstash/inputs/snmp/client.rb +11 -109
  6. data/lib/logstash/inputs/snmp/clientv3.rb +139 -0
  7. data/lib/logstash/inputs/snmp/mib.rb +22 -20
  8. data/lib/mibs/ietf/ACCOUNTING-CONTROL-MIB.dic +1316 -0
  9. data/lib/mibs/ietf/ADSL-LINE-EXT-MIB.dic +1724 -0
  10. data/lib/mibs/ietf/ADSL-LINE-MIB.dic +7297 -0
  11. data/lib/mibs/ietf/ADSL-TC-MIB.dic +160 -0
  12. data/lib/mibs/ietf/ADSL2-LINE-MIB.dic +8663 -0
  13. data/lib/mibs/ietf/ADSL2-LINE-TC-MIB.dic +1462 -0
  14. data/lib/mibs/ietf/AGENTX-MIB.dic +817 -0
  15. data/lib/mibs/ietf/AGGREGATE-MIB.dic +708 -0
  16. data/lib/mibs/ietf/ALARM-MIB.dic +1734 -0
  17. data/lib/mibs/ietf/APM-MIB.dic +2870 -0
  18. data/lib/mibs/ietf/APPC-MIB.dic +8687 -0
  19. data/lib/mibs/ietf/APPLETALK-MIB.dic +4399 -0
  20. data/lib/mibs/ietf/APPLICATION-MIB.dic +3750 -0
  21. data/lib/mibs/ietf/APPN-DLUR-MIB.dic +972 -0
  22. data/lib/mibs/ietf/APPN-MIB.dic +9364 -0
  23. data/lib/mibs/ietf/APPN-TRAP-MIB.dic +664 -0
  24. data/lib/mibs/ietf/APS-MIB.dic +2430 -0
  25. data/lib/mibs/ietf/ARC-MIB.dic +552 -0
  26. data/lib/mibs/ietf/ATM-ACCOUNTING-INFORMATION-MIB.dic +816 -0
  27. data/lib/mibs/ietf/ATM-MIB.dic +4104 -0
  28. data/lib/mibs/ietf/ATM-TC-MIB.dic +914 -0
  29. data/lib/mibs/ietf/ATM2-MIB.dic +4715 -0
  30. data/lib/mibs/ietf/BFD-STD-MIB.dic +2367 -0
  31. data/lib/mibs/ietf/BFD-TC-STD-MIB.dic +202 -0
  32. data/lib/mibs/ietf/BGP4-MIB.dic +1931 -0
  33. data/lib/mibs/ietf/BLDG-HVAC-MIB.dic +812 -0
  34. data/lib/mibs/ietf/BRIDGE-MIB.dic +2257 -0
  35. data/lib/mibs/ietf/CAPWAP-BASE-MIB.dic +4128 -0
  36. data/lib/mibs/ietf/CAPWAP-DOT11-MIB.dic +482 -0
  37. data/lib/mibs/ietf/CHARACTER-MIB.dic +1140 -0
  38. data/lib/mibs/ietf/CIRCUIT-IF-MIB.dic +493 -0
  39. data/lib/mibs/ietf/CLNS-MIB.dic +1702 -0
  40. data/lib/mibs/ietf/COFFEE-POT-MIB.dic +282 -0
  41. data/lib/mibs/ietf/COPS-CLIENT-MIB.dic +1270 -0
  42. data/lib/mibs/ietf/DECNET-PHIV-MIB.dic +5837 -0
  43. data/lib/mibs/ietf/DIAL-CONTROL-MIB.dic +2139 -0
  44. data/lib/mibs/ietf/DIFFSERV-CONFIG-MIB.dic +378 -0
  45. data/lib/mibs/ietf/DIFFSERV-MIB.dic +5073 -0
  46. data/lib/mibs/ietf/DIRECTORY-SERVER-MIB.dic +1041 -0
  47. data/lib/mibs/ietf/DISMAN-EVENT-MIB.dic +3151 -0
  48. data/lib/mibs/ietf/DISMAN-EXPRESSION-MIB.dic +1716 -0
  49. data/lib/mibs/ietf/DISMAN-NSLOOKUP-MIB.dic +698 -0
  50. data/lib/mibs/ietf/DISMAN-PING-MIB.dic +2635 -0
  51. data/lib/mibs/ietf/DISMAN-SCHEDULE-MIB.dic +1744 -0
  52. data/lib/mibs/ietf/DISMAN-SCRIPT-MIB.dic +2820 -0
  53. data/lib/mibs/ietf/DISMAN-TRACEROUTE-MIB.dic +3239 -0
  54. data/lib/mibs/ietf/DLSW-MIB.dic +5635 -0
  55. data/lib/mibs/ietf/DNS-RESOLVER-MIB.dic +1765 -0
  56. data/lib/mibs/ietf/DNS-SERVER-MIB.dic +1593 -0
  57. data/lib/mibs/ietf/DOCS-BPI-MIB.dic +2634 -0
  58. data/lib/mibs/ietf/DOCS-CABLE-DEVICE-MIB.dic +5042 -0
  59. data/lib/mibs/ietf/DOCS-IETF-BPI2-MIB.dic +5478 -0
  60. data/lib/mibs/ietf/DOCS-IETF-CABLE-DEVICE-NOTIFICATION-MIB.dic +2447 -0
  61. data/lib/mibs/ietf/DOCS-IETF-QOS-MIB.dic +4886 -0
  62. data/lib/mibs/ietf/DOCS-IETF-SUBMGT-MIB.dic +1331 -0
  63. data/lib/mibs/ietf/DOCS-IF-MIB.dic +7980 -0
  64. data/lib/mibs/ietf/DOT12-IF-MIB.dic +1066 -0
  65. data/lib/mibs/ietf/DOT12-RPTR-MIB.dic +2669 -0
  66. data/lib/mibs/ietf/DOT3-EPON-MIB.dic +3297 -0
  67. data/lib/mibs/ietf/DOT3-OAM-MIB.dic +2830 -0
  68. data/lib/mibs/ietf/DS0-MIB.dic +466 -0
  69. data/lib/mibs/ietf/DS0BUNDLE-MIB.dic +468 -0
  70. data/lib/mibs/ietf/DS1-MIB.dic +4890 -0
  71. data/lib/mibs/ietf/DS3-MIB.dic +2719 -0
  72. data/lib/mibs/ietf/DSA-MIB.dic +888 -0
  73. data/lib/mibs/ietf/DSMON-MIB.dic +6177 -0
  74. data/lib/mibs/ietf/DVB-RCS-MIB.dic +5764 -0
  75. data/lib/mibs/ietf/EBN-MIB.dic +1026 -0
  76. data/lib/mibs/ietf/EFM-CU-MIB.dic +4335 -0
  77. data/lib/mibs/ietf/ENTITY-MIB.dic +2235 -0
  78. data/lib/mibs/ietf/ENTITY-SENSOR-MIB.dic +653 -0
  79. data/lib/mibs/ietf/ENTITY-STATE-MIB.dic +457 -0
  80. data/lib/mibs/ietf/ENTITY-STATE-TC-MIB.dic +260 -0
  81. data/lib/mibs/ietf/ETHER-CHIPSET-MIB.dic +787 -0
  82. data/lib/mibs/ietf/EtherLike-MIB.dic +2548 -0
  83. data/lib/mibs/ietf/FC-MGMT-MIB.dic +3465 -0
  84. data/lib/mibs/ietf/FCIP-MGMT-MIB.dic +1596 -0
  85. data/lib/mibs/ietf/FDDI-SMT73-MIB.dic +3378 -0
  86. data/lib/mibs/ietf/FIBRE-CHANNEL-FE-MIB.dic +2504 -0
  87. data/lib/mibs/ietf/FLOAT-TC-MIB.dic +128 -0
  88. data/lib/mibs/ietf/FLOW-METER-MIB.dic +3201 -0
  89. data/lib/mibs/ietf/FORCES-MIB.dic +598 -0
  90. data/lib/mibs/ietf/FR-ATM-PVC-SERVICE-IWF-MIB.dic +1601 -0
  91. data/lib/mibs/ietf/FR-MFR-MIB.dic +1351 -0
  92. data/lib/mibs/ietf/FRAME-RELAY-DTE-MIB.dic +1688 -0
  93. data/lib/mibs/ietf/FRNETSERV-MIB.dic +3940 -0
  94. data/lib/mibs/ietf/FRSLD-MIB.dic +2580 -0
  95. data/lib/mibs/ietf/Finisher-MIB.dic +1416 -0
  96. data/lib/mibs/ietf/GMPLS-LABEL-STD-MIB.dic +965 -0
  97. data/lib/mibs/ietf/GMPLS-LSR-STD-MIB.dic +693 -0
  98. data/lib/mibs/ietf/GMPLS-TC-STD-MIB.dic +180 -0
  99. data/lib/mibs/ietf/GMPLS-TE-STD-MIB.dic +2542 -0
  100. data/lib/mibs/ietf/GSMP-MIB.dic +2468 -0
  101. data/lib/mibs/ietf/HC-ALARM-MIB.dic +1050 -0
  102. data/lib/mibs/ietf/HC-PerfHist-TC-MIB.dic +310 -0
  103. data/lib/mibs/ietf/HC-RMON-MIB.dic +4456 -0
  104. data/lib/mibs/ietf/HDSL2-SHDSL-LINE-MIB.dic +3955 -0
  105. data/lib/mibs/ietf/HOST-RESOURCES-MIB.dic +2453 -0
  106. data/lib/mibs/ietf/HPR-IP-MIB.dic +640 -0
  107. data/lib/mibs/ietf/HPR-MIB.dic +1959 -0
  108. data/lib/mibs/ietf/IANA-ITU-ALARM-TC-MIB.dic +936 -0
  109. data/lib/mibs/ietf/IF-CAP-STACK-MIB.dic +356 -0
  110. data/lib/mibs/ietf/IF-INVERTED-STACK-MIB.dic +220 -0
  111. data/lib/mibs/ietf/IF-MIB.dic +2753 -0
  112. data/lib/mibs/ietf/IFCP-MGMT-MIB.dic +1717 -0
  113. data/lib/mibs/ietf/IGMP-STD-MIB.dic +809 -0
  114. data/lib/mibs/ietf/INET-ADDRESS-MIB.dic +570 -0
  115. data/lib/mibs/ietf/INTEGRATED-SERVICES-GUARANTEED-MIB.dic +319 -0
  116. data/lib/mibs/ietf/INTEGRATED-SERVICES-MIB.dic +1196 -0
  117. data/lib/mibs/ietf/INTERFACETOPN-MIB.dic +1705 -0
  118. data/lib/mibs/ietf/IP-FORWARD-MIB.dic +1853 -0
  119. data/lib/mibs/ietf/IP-MIB.dic +7064 -0
  120. data/lib/mibs/ietf/IPATM-IPMC-MIB.dic +4830 -0
  121. data/lib/mibs/ietf/IPFIX-MIB.dic +2334 -0
  122. data/lib/mibs/ietf/IPFIX-SELECTOR-MIB.dic +215 -0
  123. data/lib/mibs/ietf/IPMCAST-MIB.dic +3390 -0
  124. data/lib/mibs/ietf/IPMROUTE-STD-MIB.dic +1246 -0
  125. data/lib/mibs/ietf/IPOA-MIB.dic +2372 -0
  126. data/lib/mibs/ietf/IPS-AUTH-MIB.dic +1609 -0
  127. data/lib/mibs/ietf/IPSEC-SPD-MIB.dic +3989 -0
  128. data/lib/mibs/ietf/IPV6-FLOW-LABEL-MIB.dic +110 -0
  129. data/lib/mibs/ietf/IPV6-ICMP-MIB.dic +748 -0
  130. data/lib/mibs/ietf/IPV6-MIB.dic +2028 -0
  131. data/lib/mibs/ietf/IPV6-MLD-MIB.dic +659 -0
  132. data/lib/mibs/ietf/IPV6-TCP-MIB.dic +332 -0
  133. data/lib/mibs/ietf/IPV6-UDP-MIB.dic +209 -0
  134. data/lib/mibs/ietf/ISCSI-MIB.dic +4613 -0
  135. data/lib/mibs/ietf/ISDN-MIB.dic +1796 -0
  136. data/lib/mibs/ietf/ISIS-MIB.dic +6215 -0
  137. data/lib/mibs/ietf/ISNS-MIB.dic +6578 -0
  138. data/lib/mibs/ietf/ITU-ALARM-MIB.dic +665 -0
  139. data/lib/mibs/ietf/ITU-ALARM-TC-MIB.dic +137 -0
  140. data/lib/mibs/ietf/Job-Monitoring-MIB.dic +2519 -0
  141. data/lib/mibs/ietf/L2TP-MIB.dic +4050 -0
  142. data/lib/mibs/ietf/LANGTAG-TC-MIB.dic +104 -0
  143. data/lib/mibs/ietf/LISP-MIB.dic +4067 -0
  144. data/lib/mibs/ietf/LMP-MIB.dic +5166 -0
  145. data/lib/mibs/ietf/MALLOC-MIB.dic +2156 -0
  146. data/lib/mibs/ietf/MAU-MIB.dic +2619 -0
  147. data/lib/mibs/ietf/MIDCOM-MIB.dic +2856 -0
  148. data/lib/mibs/ietf/MIOX25-MIB.dic +828 -0
  149. data/lib/mibs/ietf/MIP-MIB.dic +3473 -0
  150. data/lib/mibs/ietf/MOBILEIPV6-MIB.dic +5228 -0
  151. data/lib/mibs/ietf/MPLS-FTN-STD-MIB.dic +1594 -0
  152. data/lib/mibs/ietf/MPLS-L3VPN-STD-MIB.dic +2548 -0
  153. data/lib/mibs/ietf/MPLS-LC-ATM-STD-MIB.dic +491 -0
  154. data/lib/mibs/ietf/MPLS-LC-FR-STD-MIB.dic +395 -0
  155. data/lib/mibs/ietf/MPLS-LDP-ATM-STD-MIB.dic +1019 -0
  156. data/lib/mibs/ietf/MPLS-LDP-FRAME-RELAY-STD-MIB.dic +862 -0
  157. data/lib/mibs/ietf/MPLS-LDP-GENERIC-STD-MIB.dic +445 -0
  158. data/lib/mibs/ietf/MPLS-LDP-STD-MIB.dic +3657 -0
  159. data/lib/mibs/ietf/MPLS-LSR-STD-MIB.dic +3103 -0
  160. data/lib/mibs/ietf/MPLS-TC-STD-MIB.dic +911 -0
  161. data/lib/mibs/ietf/MPLS-TE-STD-MIB.dic +3673 -0
  162. data/lib/mibs/ietf/MSDP-MIB.dic +1893 -0
  163. data/lib/mibs/ietf/MTA-MIB.dic +1898 -0
  164. data/lib/mibs/ietf/Modem-MIB.dic +2054 -0
  165. data/lib/mibs/ietf/NAT-MIB.dic +3866 -0
  166. data/lib/mibs/ietf/NETWORK-SERVICES-MIB.dic +1034 -0
  167. data/lib/mibs/ietf/NHDP-MIB.dic +3005 -0
  168. data/lib/mibs/ietf/NHRP-MIB.dic +3660 -0
  169. data/lib/mibs/ietf/NOTIFICATION-LOG-MIB.dic +1156 -0
  170. data/lib/mibs/ietf/NTPv4-MIB.dic +1535 -0
  171. data/lib/mibs/ietf/OPT-IF-MIB.dic +8972 -0
  172. data/lib/mibs/ietf/OSPF-MIB.dic +5963 -0
  173. data/lib/mibs/ietf/OSPF-TRAP-MIB.dic +1190 -0
  174. data/lib/mibs/ietf/OSPFV3-MIB.dic +5708 -0
  175. data/lib/mibs/ietf/P-BRIDGE-MIB.dic +1499 -0
  176. data/lib/mibs/ietf/PARALLEL-MIB.dic +476 -0
  177. data/lib/mibs/ietf/PIM-MIB.dic +1393 -0
  178. data/lib/mibs/ietf/PIM-STD-MIB.dic +6819 -0
  179. data/lib/mibs/ietf/PINT-MIB.dic +830 -0
  180. data/lib/mibs/ietf/PKTC-IETF-MTA-MIB.dic +3191 -0
  181. data/lib/mibs/ietf/PKTC-IETF-SIG-MIB.dic +4713 -0
  182. data/lib/mibs/ietf/PMIPV6-MIB.dic +3010 -0
  183. data/lib/mibs/ietf/PMIPV6-TC-MIB.dic +293 -0
  184. data/lib/mibs/ietf/POLICY-BASED-MANAGEMENT-MIB.dic +3316 -0
  185. data/lib/mibs/ietf/POWER-ETHERNET-MIB.dic +959 -0
  186. data/lib/mibs/ietf/PPP-BRIDGE-NCP-MIB.dic +587 -0
  187. data/lib/mibs/ietf/PPP-IP-NCP-MIB.dic +269 -0
  188. data/lib/mibs/ietf/PPP-LCP-MIB.dic +994 -0
  189. data/lib/mibs/ietf/PPP-SEC-MIB.dic +411 -0
  190. data/lib/mibs/ietf/PSAMP-MIB.dic +998 -0
  191. data/lib/mibs/ietf/PTOPO-MIB.dic +1135 -0
  192. data/lib/mibs/ietf/PW-ATM-MIB.dic +1642 -0
  193. data/lib/mibs/ietf/PW-CEP-STD-MIB.dic +3661 -0
  194. data/lib/mibs/ietf/PW-STD-MIB.dic +3592 -0
  195. data/lib/mibs/ietf/PW-TC-STD-MIB.dic +437 -0
  196. data/lib/mibs/ietf/PW-TDM-MIB.dic +1896 -0
  197. data/lib/mibs/ietf/PerfHist-TC-MIB.dic +152 -0
  198. data/lib/mibs/ietf/Printer-MIB.dic +6665 -0
  199. data/lib/mibs/ietf/Q-BRIDGE-MIB.dic +3115 -0
  200. data/lib/mibs/ietf/RADIUS-ACC-CLIENT-MIB.dic +991 -0
  201. data/lib/mibs/ietf/RADIUS-ACC-SERVER-MIB.dic +1183 -0
  202. data/lib/mibs/ietf/RADIUS-AUTH-CLIENT-MIB.dic +1073 -0
  203. data/lib/mibs/ietf/RADIUS-AUTH-SERVER-MIB.dic +1251 -0
  204. data/lib/mibs/ietf/RADIUS-DYNAUTH-CLIENT-MIB.dic +1116 -0
  205. data/lib/mibs/ietf/RADIUS-DYNAUTH-SERVER-MIB.dic +1003 -0
  206. data/lib/mibs/ietf/RAQMON-MIB.dic +2695 -0
  207. data/lib/mibs/ietf/RBRIDGE-MIB.dic +2981 -0
  208. data/lib/mibs/ietf/RDBMS-MIB.dic +1935 -0
  209. data/lib/mibs/ietf/RFC1065-SMI.dic +108 -0
  210. data/lib/mibs/ietf/RFC1155-SMI.dic +118 -0
  211. data/lib/mibs/ietf/RFC1158-MIB.dic +2440 -0
  212. data/lib/mibs/ietf/RFC1213-MIB.dic +3434 -0
  213. data/lib/mibs/ietf/RFC1269-MIB.dic +557 -0
  214. data/lib/mibs/ietf/RFC1271-MIB.dic +4135 -0
  215. data/lib/mibs/ietf/RFC1285-MIB.dic +2842 -0
  216. data/lib/mibs/ietf/RFC1316-MIB.dic +800 -0
  217. data/lib/mibs/ietf/RFC1381-MIB.dic +1347 -0
  218. data/lib/mibs/ietf/RFC1382-MIB.dic +3820 -0
  219. data/lib/mibs/ietf/RFC1414-MIB.dic +214 -0
  220. data/lib/mibs/ietf/RIPv2-MIB.dic +773 -0
  221. data/lib/mibs/ietf/RMON-MIB.dic +5551 -0
  222. data/lib/mibs/ietf/RMON2-MIB.dic +8224 -0
  223. data/lib/mibs/ietf/ROHC-MIB.dic +1613 -0
  224. data/lib/mibs/ietf/ROHC-RTP-MIB.dic +859 -0
  225. data/lib/mibs/ietf/ROHC-UNCOMPRESSED-MIB.dic +267 -0
  226. data/lib/mibs/ietf/RPKI-ROUTER-MIB.dic +1363 -0
  227. data/lib/mibs/ietf/RS-232-MIB.dic +1335 -0
  228. data/lib/mibs/ietf/RSERPOOL-MIB.dic +2501 -0
  229. data/lib/mibs/ietf/RSTP-MIB.dic +427 -0
  230. data/lib/mibs/ietf/RSVP-MIB.dic +4135 -0
  231. data/lib/mibs/ietf/RTP-MIB.dic +1376 -0
  232. data/lib/mibs/ietf/SCSI-MIB.dic +3804 -0
  233. data/lib/mibs/ietf/SCTP-MIB.dic +1924 -0
  234. data/lib/mibs/ietf/SFLOW-MIB.dic +568 -0
  235. data/lib/mibs/ietf/SIP-COMMON-MIB.dic +2769 -0
  236. data/lib/mibs/ietf/SIP-MIB.dic +1438 -0
  237. data/lib/mibs/ietf/SIP-SERVER-MIB.dic +1150 -0
  238. data/lib/mibs/ietf/SIP-TC-MIB.dic +257 -0
  239. data/lib/mibs/ietf/SIP-UA-MIB.dic +268 -0
  240. data/lib/mibs/ietf/SLAPM-MIB.dic +4527 -0
  241. data/lib/mibs/ietf/SMON-MIB.dic +1758 -0
  242. data/lib/mibs/ietf/SNA-NAU-MIB.dic +4042 -0
  243. data/lib/mibs/ietf/SNA-SDLC-MIB.dic +3858 -0
  244. data/lib/mibs/ietf/SNMP-COMMUNITY-MIB.dic +715 -0
  245. data/lib/mibs/ietf/SNMP-FRAMEWORK-MIB.dic +709 -0
  246. data/lib/mibs/ietf/SNMP-MPD-MIB.dic +230 -0
  247. data/lib/mibs/ietf/SNMP-NOTIFICATION-MIB.dic +859 -0
  248. data/lib/mibs/ietf/SNMP-PROXY-MIB.dic +414 -0
  249. data/lib/mibs/ietf/SNMP-REPEATER-MIB.dic +4335 -0
  250. data/lib/mibs/ietf/SNMP-SSH-TM-MIB.dic +447 -0
  251. data/lib/mibs/ietf/SNMP-TARGET-MIB.dic +924 -0
  252. data/lib/mibs/ietf/SNMP-TLS-TM-MIB.dic +1449 -0
  253. data/lib/mibs/ietf/SNMP-TSM-MIB.dic +315 -0
  254. data/lib/mibs/ietf/SNMP-USER-BASED-SM-MIB.dic +1164 -0
  255. data/lib/mibs/ietf/SNMP-USM-AES-MIB.dic +95 -0
  256. data/lib/mibs/ietf/SNMP-USM-DH-OBJECTS-MIB.dic +653 -0
  257. data/lib/mibs/ietf/SNMP-VIEW-BASED-ACM-MIB.dic +1202 -0
  258. data/lib/mibs/ietf/SNMPv2-MIB.dic +1382 -0
  259. data/lib/mibs/ietf/SNMPv2-SMI.dic +223 -0
  260. data/lib/mibs/ietf/SNMPv2-USEC-MIB.dic +405 -0
  261. data/lib/mibs/ietf/SONET-MIB.dic +3308 -0
  262. data/lib/mibs/ietf/SOURCE-ROUTING-MIB.dic +542 -0
  263. data/lib/mibs/ietf/SSPM-MIB.dic +1530 -0
  264. data/lib/mibs/ietf/SYSAPPL-MIB.dic +2092 -0
  265. data/lib/mibs/ietf/T11-FC-FABRIC-ADDR-MGR-MIB.dic +1779 -0
  266. data/lib/mibs/ietf/T11-FC-FABRIC-CONFIG-SERVER-MIB.dic +2822 -0
  267. data/lib/mibs/ietf/T11-FC-FABRIC-LOCK-MIB.dic +700 -0
  268. data/lib/mibs/ietf/T11-FC-FSPF-MIB.dic +1889 -0
  269. data/lib/mibs/ietf/T11-FC-NAME-SERVER-MIB.dic +1775 -0
  270. data/lib/mibs/ietf/T11-FC-ROUTE-MIB.dic +655 -0
  271. data/lib/mibs/ietf/T11-FC-RSCN-MIB.dic +1110 -0
  272. data/lib/mibs/ietf/T11-FC-VIRTUAL-FABRIC-MIB.dic +770 -0
  273. data/lib/mibs/ietf/T11-FC-ZONE-SERVER-MIB.dic +3886 -0
  274. data/lib/mibs/ietf/T11-TC-MIB.dic +110 -0
  275. data/lib/mibs/ietf/TCP-ESTATS-MIB.dic +3926 -0
  276. data/lib/mibs/ietf/TCP-MIB.dic +1319 -0
  277. data/lib/mibs/ietf/TCPIPX-MIB.dic +457 -0
  278. data/lib/mibs/ietf/TE-LINK-STD-MIB.dic +2876 -0
  279. data/lib/mibs/ietf/TE-MIB.dic +2924 -0
  280. data/lib/mibs/ietf/TED-MIB.dic +1749 -0
  281. data/lib/mibs/ietf/TIME-AGGREGATE-MIB.dic +550 -0
  282. data/lib/mibs/ietf/TN3270E-MIB.dic +2785 -0
  283. data/lib/mibs/ietf/TN3270E-RT-MIB.dic +1317 -0
  284. data/lib/mibs/ietf/TOKEN-RING-RMON-MIB.dic +2820 -0
  285. data/lib/mibs/ietf/TOKENRING-MIB.dic +1184 -0
  286. data/lib/mibs/ietf/TOKENRING-STATION-SR-MIB.dic +292 -0
  287. data/lib/mibs/ietf/TRANSPORT-ADDRESS-MIB.dic +610 -0
  288. data/lib/mibs/ietf/TRIP-MIB.dic +3159 -0
  289. data/lib/mibs/ietf/TRIP-TC-MIB.dic +241 -0
  290. data/lib/mibs/ietf/TUNNEL-MIB.dic +1095 -0
  291. data/lib/mibs/ietf/UDP-MIB.dic +751 -0
  292. data/lib/mibs/ietf/UDPLITE-MIB.dic +704 -0
  293. data/lib/mibs/ietf/UPS-MIB.dic +3088 -0
  294. data/lib/mibs/ietf/URI-TC-MIB.dic +193 -0
  295. data/lib/mibs/ietf/UUID-TC-MIB.dic +135 -0
  296. data/lib/mibs/ietf/VDSL-LINE-EXT-MCM-MIB.dic +989 -0
  297. data/lib/mibs/ietf/VDSL-LINE-EXT-SCM-MIB.dic +605 -0
  298. data/lib/mibs/ietf/VDSL-LINE-MIB.dic +4518 -0
  299. data/lib/mibs/ietf/VDSL2-LINE-MIB.dic +11029 -0
  300. data/lib/mibs/ietf/VDSL2-LINE-TC-MIB.dic +3152 -0
  301. data/lib/mibs/ietf/VPN-TC-STD-MIB.dic +121 -0
  302. data/lib/mibs/ietf/VRRP-MIB.dic +1163 -0
  303. data/lib/mibs/ietf/VRRPV3-MIB.dic +1403 -0
  304. data/lib/mibs/ietf/WWW-MIB.dic +1810 -0
  305. data/lib/mibs/logstash/iso.dic +18 -0
  306. data/logstash-input-snmp.gemspec +1 -1
  307. data/spec/inputs/snmp/mib_spec.rb +10 -17
  308. data/spec/inputs/snmp_spec.rb +27 -1
  309. metadata +302 -2
@@ -0,0 +1,3820 @@
1
+ # python version 1.0 DO NOT EDIT
2
+ #
3
+ # This python file has been generated by smidump version 0.5.0:
4
+ #
5
+ # smidump -f python RFC1382-MIB
6
+
7
+ FILENAME = "./libsmi-0.5.0/mibs/ietf/RFC1382-MIB"
8
+
9
+ MIB = {
10
+ "moduleName" : "RFC1382-MIB",
11
+
12
+ "RFC1382-MIB" : {
13
+ "nodetype" : "module",
14
+ "language" : "SMIv1",
15
+ },
16
+
17
+ "imports" : (
18
+ {"module" : "RFC1155-SMI", "name" : "Counter"},
19
+ {"module" : "RFC1155-SMI", "name" : "Gauge"},
20
+ {"module" : "RFC1155-SMI", "name" : "TimeTicks"},
21
+ {"module" : "RFC-1212", "name" : "OBJECT-TYPE"},
22
+ {"module" : "RFC1213-MIB", "name" : "DisplayString"},
23
+ {"module" : "RFC1213-MIB", "name" : "transmission"},
24
+ {"module" : "RFC-1215", "name" : "TRAP-TYPE"},
25
+ {"module" : "RFC1271-MIB", "name" : "EntryStatus"},
26
+ {"module" : "RFC1381-MIB", "name" : "PositiveInteger"},
27
+ {"module" : "RFC1381-MIB", "name" : "IfIndexType"},
28
+ ),
29
+
30
+ "typedefs" : {
31
+ "X121Address" : {
32
+ "basetype" : "OctetString",
33
+ "ranges" : [
34
+ {
35
+ "min" : "0",
36
+ "max" : "17"
37
+ },
38
+ ],
39
+ "range" : {
40
+ "min" : "0",
41
+ "max" : "17"
42
+ },
43
+ },
44
+ }, # typedefs
45
+
46
+ "nodes" : {
47
+ "x25" : {
48
+ "nodetype" : "node",
49
+ "moduleName" : "RFC1382-MIB",
50
+ "oid" : "1.3.6.1.2.1.10.5",
51
+ }, # node
52
+ "x25AdmnTable" : {
53
+ "nodetype" : "table",
54
+ "moduleName" : "RFC1382-MIB",
55
+ "oid" : "1.3.6.1.2.1.10.5.1",
56
+ "status" : "current",
57
+ "description" :
58
+ """This table contains the administratively
59
+ set configuration parameters for an X.25
60
+ Packet Level Entity (PLE).
61
+
62
+ Most of the objects in this table have
63
+ corresponding objects in the x25OperTable.
64
+ This table contains the values as last set
65
+ by the administrator. The x25OperTable
66
+ contains the values actually in use by an
67
+ X.25 PLE.
68
+
69
+ Changing an administrative value may or may
70
+ not change a current operating value. The
71
+ operating value may not change until the
72
+ interface is restarted. Some
73
+ implementations may change the values
74
+ immediately upon changing the administrative
75
+ table. All implementations are required to
76
+ load the values from the administrative
77
+ table when initializing a PLE.""",
78
+ }, # table
79
+ "x25AdmnEntry" : {
80
+ "nodetype" : "row",
81
+ "moduleName" : "RFC1382-MIB",
82
+ "oid" : "1.3.6.1.2.1.10.5.1.1",
83
+ "status" : "current",
84
+ "linkage" : [
85
+ "x25AdmnIndex",
86
+ ],
87
+ "description" :
88
+ """Entries of x25AdmnTable.""",
89
+ }, # row
90
+ "x25AdmnIndex" : {
91
+ "nodetype" : "column",
92
+ "moduleName" : "RFC1382-MIB",
93
+ "oid" : "1.3.6.1.2.1.10.5.1.1.1",
94
+ "status" : "current",
95
+ "syntax" : {
96
+ "type" : { "module" :"RFC1381-MIB", "name" : "IfIndexType"},
97
+ },
98
+ "access" : "readonly",
99
+ "description" :
100
+ """The ifIndex value for the X.25 Interface.""",
101
+ }, # column
102
+ "x25AdmnInterfaceMode" : {
103
+ "nodetype" : "column",
104
+ "moduleName" : "RFC1382-MIB",
105
+ "oid" : "1.3.6.1.2.1.10.5.1.1.2",
106
+ "status" : "current",
107
+ "syntax" : {
108
+ "type" : {
109
+ "basetype" : "Enumeration",
110
+ "dte" : {
111
+ "nodetype" : "namednumber",
112
+ "number" : "1"
113
+ },
114
+ "dce" : {
115
+ "nodetype" : "namednumber",
116
+ "number" : "2"
117
+ },
118
+ "dxe" : {
119
+ "nodetype" : "namednumber",
120
+ "number" : "3"
121
+ },
122
+ },
123
+ },
124
+ "access" : "readwrite",
125
+ "description" :
126
+ """Identifies DCE/DTE mode in which the
127
+ interface operates. A value of dxe
128
+ indicates the mode will be determined by XID
129
+ negotiation.""",
130
+ "reference" :
131
+ """10733 5.9 interfaceMode""",
132
+ }, # column
133
+ "x25AdmnMaxActiveCircuits" : {
134
+ "nodetype" : "column",
135
+ "moduleName" : "RFC1382-MIB",
136
+ "oid" : "1.3.6.1.2.1.10.5.1.1.3",
137
+ "status" : "current",
138
+ "syntax" : {
139
+ "type" : {
140
+ "basetype" : "Integer32",
141
+ "ranges" : [
142
+ {
143
+ "min" : "0",
144
+ "max" : "4096"
145
+ },
146
+ ],
147
+ "range" : {
148
+ "min" : "0",
149
+ "max" : "4096"
150
+ },
151
+ },
152
+ },
153
+ "access" : "readwrite",
154
+ "description" :
155
+ """The maximum number of circuits this PLE can
156
+ support; including PVCs.""",
157
+ "reference" :
158
+ """10733 5.9 maxActiveCircuits;
159
+ See ISO 8208, Section 3.7""",
160
+ }, # column
161
+ "x25AdmnPacketSequencing" : {
162
+ "nodetype" : "column",
163
+ "moduleName" : "RFC1382-MIB",
164
+ "oid" : "1.3.6.1.2.1.10.5.1.1.4",
165
+ "status" : "current",
166
+ "syntax" : {
167
+ "type" : {
168
+ "basetype" : "Enumeration",
169
+ "modulo8" : {
170
+ "nodetype" : "namednumber",
171
+ "number" : "1"
172
+ },
173
+ "modulo128" : {
174
+ "nodetype" : "namednumber",
175
+ "number" : "2"
176
+ },
177
+ },
178
+ },
179
+ "access" : "readwrite",
180
+ "description" :
181
+ """The modulus of the packet sequence number
182
+ space.""",
183
+ "reference" :
184
+ """10733 extendedPacketSequencing;
185
+ See ISO 8208 Section 7.1.1""",
186
+ }, # column
187
+ "x25AdmnRestartTimer" : {
188
+ "nodetype" : "column",
189
+ "moduleName" : "RFC1382-MIB",
190
+ "oid" : "1.3.6.1.2.1.10.5.1.1.5",
191
+ "status" : "current",
192
+ "syntax" : {
193
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
194
+ },
195
+ "access" : "readwrite",
196
+ "description" :
197
+ """The T20 restart timer in milliseconds.""",
198
+ "reference" :
199
+ """10733 5.9 restartTime
200
+ See ISO 8208 Section 4.1, table 26""",
201
+ }, # column
202
+ "x25AdmnCallTimer" : {
203
+ "nodetype" : "column",
204
+ "moduleName" : "RFC1382-MIB",
205
+ "oid" : "1.3.6.1.2.1.10.5.1.1.6",
206
+ "status" : "current",
207
+ "syntax" : {
208
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
209
+ },
210
+ "access" : "readwrite",
211
+ "description" :
212
+ """The T21 Call timer in milliseconds.""",
213
+ "reference" :
214
+ """10733 callTime;
215
+ See ISO 8208 Section 5.2.1, table 26""",
216
+ }, # column
217
+ "x25AdmnResetTimer" : {
218
+ "nodetype" : "column",
219
+ "moduleName" : "RFC1382-MIB",
220
+ "oid" : "1.3.6.1.2.1.10.5.1.1.7",
221
+ "status" : "current",
222
+ "syntax" : {
223
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
224
+ },
225
+ "access" : "readwrite",
226
+ "description" :
227
+ """The T22 Reset timer in milliseconds.""",
228
+ "reference" :
229
+ """10733 resetTime;
230
+ See ISO 8208 Section 8.1, table 26""",
231
+ }, # column
232
+ "x25AdmnClearTimer" : {
233
+ "nodetype" : "column",
234
+ "moduleName" : "RFC1382-MIB",
235
+ "oid" : "1.3.6.1.2.1.10.5.1.1.8",
236
+ "status" : "current",
237
+ "syntax" : {
238
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
239
+ },
240
+ "access" : "readwrite",
241
+ "description" :
242
+ """The T23 Clear timer in milliseconds.""",
243
+ "reference" :
244
+ """10733 clearTime;
245
+ See ISO 8208 Section 5.5.1, table 26""",
246
+ }, # column
247
+ "x25AdmnWindowTimer" : {
248
+ "nodetype" : "column",
249
+ "moduleName" : "RFC1382-MIB",
250
+ "oid" : "1.3.6.1.2.1.10.5.1.1.9",
251
+ "status" : "current",
252
+ "syntax" : {
253
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
254
+ },
255
+ "access" : "readwrite",
256
+ "description" :
257
+ """The T24 window status transmission timer in
258
+ milliseconds. A value of 2147483647
259
+ indicates no window timer in use.""",
260
+ "reference" :
261
+ """10733 5.10.1 windowTime (opt);
262
+ See ISO 8208 Section 11.2.2, table 26""",
263
+ }, # column
264
+ "x25AdmnDataRxmtTimer" : {
265
+ "nodetype" : "column",
266
+ "moduleName" : "RFC1382-MIB",
267
+ "oid" : "1.3.6.1.2.1.10.5.1.1.10",
268
+ "status" : "current",
269
+ "syntax" : {
270
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
271
+ },
272
+ "access" : "readwrite",
273
+ "description" :
274
+ """The T25 data retransmission timer in
275
+ milliseconds. A value of 2147483647
276
+ indicates no data retransmission timer in
277
+ use.""",
278
+ "reference" :
279
+ """10733 5.10.1 dataRetransmissionTime (opt);
280
+ See ISO 8208 Section 11.2.1, table 26""",
281
+ }, # column
282
+ "x25AdmnInterruptTimer" : {
283
+ "nodetype" : "column",
284
+ "moduleName" : "RFC1382-MIB",
285
+ "oid" : "1.3.6.1.2.1.10.5.1.1.11",
286
+ "status" : "current",
287
+ "syntax" : {
288
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
289
+ },
290
+ "access" : "readwrite",
291
+ "description" :
292
+ """The T26 interrupt timer in milliseconds. A
293
+ value of 2147483647 indicates no interrupt
294
+ timer in use.""",
295
+ "reference" :
296
+ """10733 interruptTime;
297
+ See ISO 8208 Section 6.8.1, table 26""",
298
+ }, # column
299
+ "x25AdmnRejectTimer" : {
300
+ "nodetype" : "column",
301
+ "moduleName" : "RFC1382-MIB",
302
+ "oid" : "1.3.6.1.2.1.10.5.1.1.12",
303
+ "status" : "current",
304
+ "syntax" : {
305
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
306
+ },
307
+ "access" : "readwrite",
308
+ "description" :
309
+ """The T27 Reject retransmission timer in
310
+ milliseconds. A value of 2147483647
311
+ indicates no reject timer in use.""",
312
+ "reference" :
313
+ """10733 5.10.1 dataRejectTime (opt);
314
+ See ISO 8208 Section 13.4.1, table 26""",
315
+ }, # column
316
+ "x25AdmnRegistrationRequestTimer" : {
317
+ "nodetype" : "column",
318
+ "moduleName" : "RFC1382-MIB",
319
+ "oid" : "1.3.6.1.2.1.10.5.1.1.13",
320
+ "status" : "current",
321
+ "syntax" : {
322
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
323
+ },
324
+ "access" : "readwrite",
325
+ "description" :
326
+ """The T28 registration timer in milliseconds.
327
+ A value of 2147483647 indicates no
328
+ registration timer in use.""",
329
+ "reference" :
330
+ """10733 5.8.1 registrationRequestTime (opt)
331
+ See ISO 8208 Section 13.1.1.1, table 26""",
332
+ }, # column
333
+ "x25AdmnMinimumRecallTimer" : {
334
+ "nodetype" : "column",
335
+ "moduleName" : "RFC1382-MIB",
336
+ "oid" : "1.3.6.1.2.1.10.5.1.1.14",
337
+ "status" : "current",
338
+ "syntax" : {
339
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
340
+ },
341
+ "access" : "readwrite",
342
+ "description" :
343
+ """Minimum time interval between unsuccessful
344
+ call attempts in milliseconds.""",
345
+ "reference" :
346
+ """10733 5.9 minimum RecallTimer""",
347
+ }, # column
348
+ "x25AdmnRestartCount" : {
349
+ "nodetype" : "column",
350
+ "moduleName" : "RFC1382-MIB",
351
+ "oid" : "1.3.6.1.2.1.10.5.1.1.15",
352
+ "status" : "current",
353
+ "syntax" : {
354
+ "type" : {
355
+ "basetype" : "Integer32",
356
+ "ranges" : [
357
+ {
358
+ "min" : "0",
359
+ "max" : "65535"
360
+ },
361
+ ],
362
+ "range" : {
363
+ "min" : "0",
364
+ "max" : "65535"
365
+ },
366
+ },
367
+ },
368
+ "access" : "readwrite",
369
+ "description" :
370
+ """The R20 restart retransmission count.""",
371
+ "reference" :
372
+ """10733 5.9 restartCount;
373
+ See ISO 8208 Section 4.1, table 27""",
374
+ }, # column
375
+ "x25AdmnResetCount" : {
376
+ "nodetype" : "column",
377
+ "moduleName" : "RFC1382-MIB",
378
+ "oid" : "1.3.6.1.2.1.10.5.1.1.16",
379
+ "status" : "current",
380
+ "syntax" : {
381
+ "type" : {
382
+ "basetype" : "Integer32",
383
+ "ranges" : [
384
+ {
385
+ "min" : "0",
386
+ "max" : "65535"
387
+ },
388
+ ],
389
+ "range" : {
390
+ "min" : "0",
391
+ "max" : "65535"
392
+ },
393
+ },
394
+ },
395
+ "access" : "readwrite",
396
+ "description" :
397
+ """The r22 Reset retransmission count.""",
398
+ "reference" :
399
+ """10733 resetCount;
400
+ See section ISO 8208 8.1, table 27""",
401
+ }, # column
402
+ "x25AdmnClearCount" : {
403
+ "nodetype" : "column",
404
+ "moduleName" : "RFC1382-MIB",
405
+ "oid" : "1.3.6.1.2.1.10.5.1.1.17",
406
+ "status" : "current",
407
+ "syntax" : {
408
+ "type" : {
409
+ "basetype" : "Integer32",
410
+ "ranges" : [
411
+ {
412
+ "min" : "0",
413
+ "max" : "65535"
414
+ },
415
+ ],
416
+ "range" : {
417
+ "min" : "0",
418
+ "max" : "65535"
419
+ },
420
+ },
421
+ },
422
+ "access" : "readwrite",
423
+ "description" :
424
+ """The r23 Clear retransmission count.""",
425
+ "reference" :
426
+ """10733 clearCount;
427
+ See ISO 8208 Section 5.5.1, table 27""",
428
+ }, # column
429
+ "x25AdmnDataRxmtCount" : {
430
+ "nodetype" : "column",
431
+ "moduleName" : "RFC1382-MIB",
432
+ "oid" : "1.3.6.1.2.1.10.5.1.1.18",
433
+ "status" : "current",
434
+ "syntax" : {
435
+ "type" : {
436
+ "basetype" : "Integer32",
437
+ "ranges" : [
438
+ {
439
+ "min" : "0",
440
+ "max" : "65535"
441
+ },
442
+ ],
443
+ "range" : {
444
+ "min" : "0",
445
+ "max" : "65535"
446
+ },
447
+ },
448
+ },
449
+ "access" : "readwrite",
450
+ "description" :
451
+ """The R25 Data retransmission count. This
452
+ value is irrelevant if the
453
+ x25AdmnDataRxmtTimer indicates no timer in
454
+ use.""",
455
+ "reference" :
456
+ """10733 5.10.1 dataRetransmissionCount (opt)
457
+ See ISO 8208 Section 11.2.1, table 27""",
458
+ }, # column
459
+ "x25AdmnRejectCount" : {
460
+ "nodetype" : "column",
461
+ "moduleName" : "RFC1382-MIB",
462
+ "oid" : "1.3.6.1.2.1.10.5.1.1.19",
463
+ "status" : "current",
464
+ "syntax" : {
465
+ "type" : {
466
+ "basetype" : "Integer32",
467
+ "ranges" : [
468
+ {
469
+ "min" : "0",
470
+ "max" : "65535"
471
+ },
472
+ ],
473
+ "range" : {
474
+ "min" : "0",
475
+ "max" : "65535"
476
+ },
477
+ },
478
+ },
479
+ "access" : "readwrite",
480
+ "description" :
481
+ """The R27 reject retransmission count. This
482
+ value is irrelevant if the
483
+ x25AdmnRejectTimer indicates no timer in
484
+ use.""",
485
+ "reference" :
486
+ """10733 5.10.1 dataRejectCount (opt)""",
487
+ }, # column
488
+ "x25AdmnRegistrationRequestCount" : {
489
+ "nodetype" : "column",
490
+ "moduleName" : "RFC1382-MIB",
491
+ "oid" : "1.3.6.1.2.1.10.5.1.1.20",
492
+ "status" : "current",
493
+ "syntax" : {
494
+ "type" : {
495
+ "basetype" : "Integer32",
496
+ "ranges" : [
497
+ {
498
+ "min" : "0",
499
+ "max" : "65535"
500
+ },
501
+ ],
502
+ "range" : {
503
+ "min" : "0",
504
+ "max" : "65535"
505
+ },
506
+ },
507
+ },
508
+ "access" : "readwrite",
509
+ "description" :
510
+ """The R28 Registration retransmission Count.
511
+ This value is irrelevant if the
512
+ x25AdmnRegistrationRequestTimer indicates no
513
+ timer in use.""",
514
+ "reference" :
515
+ """10733 5.8.1 registrationRequestCount (opt);
516
+ See ISO 8208 Section 13.1.1.1, table 27""",
517
+ }, # column
518
+ "x25AdmnNumberPVCs" : {
519
+ "nodetype" : "column",
520
+ "moduleName" : "RFC1382-MIB",
521
+ "oid" : "1.3.6.1.2.1.10.5.1.1.21",
522
+ "status" : "current",
523
+ "syntax" : {
524
+ "type" : {
525
+ "basetype" : "Integer32",
526
+ "ranges" : [
527
+ {
528
+ "min" : "0",
529
+ "max" : "4096"
530
+ },
531
+ ],
532
+ "range" : {
533
+ "min" : "0",
534
+ "max" : "4096"
535
+ },
536
+ },
537
+ },
538
+ "access" : "readwrite",
539
+ "description" :
540
+ """The number of PVC configured for this PLE.
541
+ The PVCs use channel numbers from 1 to this
542
+ number.""",
543
+ }, # column
544
+ "x25AdmnDefCallParamId" : {
545
+ "nodetype" : "column",
546
+ "moduleName" : "RFC1382-MIB",
547
+ "oid" : "1.3.6.1.2.1.10.5.1.1.22",
548
+ "status" : "current",
549
+ "syntax" : {
550
+ "type" : { "module" :"", "name" : "ObjectIdentifier"},
551
+ },
552
+ "access" : "readwrite",
553
+ "description" :
554
+ """This identifies the instance of the
555
+ x25CallParmIndex for the entry in the
556
+ x25CallParmTable which contains the default
557
+ call parameters for this PLE.""",
558
+ }, # column
559
+ "x25AdmnLocalAddress" : {
560
+ "nodetype" : "column",
561
+ "moduleName" : "RFC1382-MIB",
562
+ "oid" : "1.3.6.1.2.1.10.5.1.1.23",
563
+ "status" : "current",
564
+ "syntax" : {
565
+ "type" : { "module" :"RFC1382-MIB", "name" : "X121Address"},
566
+ },
567
+ "access" : "readwrite",
568
+ "description" :
569
+ """The local address for this PLE subnetwork.
570
+ A zero length address maybe returned by PLEs
571
+ that only support PVCs.""",
572
+ "reference" :
573
+ """10733 5.9 localDTEAddress""",
574
+ }, # column
575
+ "x25AdmnProtocolVersionSupported" : {
576
+ "nodetype" : "column",
577
+ "moduleName" : "RFC1382-MIB",
578
+ "oid" : "1.3.6.1.2.1.10.5.1.1.24",
579
+ "status" : "current",
580
+ "syntax" : {
581
+ "type" : { "module" :"", "name" : "ObjectIdentifier"},
582
+ },
583
+ "access" : "readwrite",
584
+ "description" :
585
+ """Identifies the version of the X.25 protocol
586
+ this interface should support. Object
587
+ identifiers for common versions are defined
588
+ below in the x25ProtocolVersion subtree.""",
589
+ "reference" :
590
+ """10733 5.9 protocolVersionSupported""",
591
+ }, # column
592
+ "x25OperTable" : {
593
+ "nodetype" : "table",
594
+ "moduleName" : "RFC1382-MIB",
595
+ "oid" : "1.3.6.1.2.1.10.5.2",
596
+ "status" : "current",
597
+ "description" :
598
+ """The operation parameters in use by the X.25
599
+ PLE.""",
600
+ }, # table
601
+ "x25OperEntry" : {
602
+ "nodetype" : "row",
603
+ "moduleName" : "RFC1382-MIB",
604
+ "oid" : "1.3.6.1.2.1.10.5.2.1",
605
+ "status" : "current",
606
+ "linkage" : [
607
+ "x25OperIndex",
608
+ ],
609
+ "description" :
610
+ """Entries of x25OperTable.""",
611
+ }, # row
612
+ "x25OperIndex" : {
613
+ "nodetype" : "column",
614
+ "moduleName" : "RFC1382-MIB",
615
+ "oid" : "1.3.6.1.2.1.10.5.2.1.1",
616
+ "status" : "current",
617
+ "syntax" : {
618
+ "type" : { "module" :"RFC1381-MIB", "name" : "IfIndexType"},
619
+ },
620
+ "access" : "readonly",
621
+ "description" :
622
+ """The ifIndex value for the X.25 interface.""",
623
+ }, # column
624
+ "x25OperInterfaceMode" : {
625
+ "nodetype" : "column",
626
+ "moduleName" : "RFC1382-MIB",
627
+ "oid" : "1.3.6.1.2.1.10.5.2.1.2",
628
+ "status" : "current",
629
+ "syntax" : {
630
+ "type" : {
631
+ "basetype" : "Enumeration",
632
+ "dte" : {
633
+ "nodetype" : "namednumber",
634
+ "number" : "1"
635
+ },
636
+ "dce" : {
637
+ "nodetype" : "namednumber",
638
+ "number" : "2"
639
+ },
640
+ "dxe" : {
641
+ "nodetype" : "namednumber",
642
+ "number" : "3"
643
+ },
644
+ },
645
+ },
646
+ "access" : "readonly",
647
+ "description" :
648
+ """Identifies DCE/DTE mode in which the
649
+ interface operates. A value of dxe
650
+ indicates the role will be determined by XID
651
+ negotiation at the Link Layer and that
652
+ negotiation has not yet taken place.""",
653
+ "reference" :
654
+ """10733 5.9 interfaceMode""",
655
+ }, # column
656
+ "x25OperMaxActiveCircuits" : {
657
+ "nodetype" : "column",
658
+ "moduleName" : "RFC1382-MIB",
659
+ "oid" : "1.3.6.1.2.1.10.5.2.1.3",
660
+ "status" : "current",
661
+ "syntax" : {
662
+ "type" : {
663
+ "basetype" : "Integer32",
664
+ "ranges" : [
665
+ {
666
+ "min" : "0",
667
+ "max" : "4096"
668
+ },
669
+ ],
670
+ "range" : {
671
+ "min" : "0",
672
+ "max" : "4096"
673
+ },
674
+ },
675
+ },
676
+ "access" : "readonly",
677
+ "description" :
678
+ """Maximum number of circuits this PLE can
679
+ support.""",
680
+ "reference" :
681
+ """10733 5.9 maxActiveCircuits
682
+ See ISO 8208, Section 3.7""",
683
+ }, # column
684
+ "x25OperPacketSequencing" : {
685
+ "nodetype" : "column",
686
+ "moduleName" : "RFC1382-MIB",
687
+ "oid" : "1.3.6.1.2.1.10.5.2.1.4",
688
+ "status" : "current",
689
+ "syntax" : {
690
+ "type" : {
691
+ "basetype" : "Enumeration",
692
+ "modulo8" : {
693
+ "nodetype" : "namednumber",
694
+ "number" : "1"
695
+ },
696
+ "modulo128" : {
697
+ "nodetype" : "namednumber",
698
+ "number" : "2"
699
+ },
700
+ },
701
+ },
702
+ "access" : "readonly",
703
+ "description" :
704
+ """The modulus of the packet sequence number
705
+ space.""",
706
+ "reference" :
707
+ """10733 extendedPacketSequencing;
708
+ See ISO 8208 Section 7.1.1""",
709
+ }, # column
710
+ "x25OperRestartTimer" : {
711
+ "nodetype" : "column",
712
+ "moduleName" : "RFC1382-MIB",
713
+ "oid" : "1.3.6.1.2.1.10.5.2.1.5",
714
+ "status" : "current",
715
+ "syntax" : {
716
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
717
+ },
718
+ "access" : "readonly",
719
+ "description" :
720
+ """The T20 restart timer in milliseconds.""",
721
+ "reference" :
722
+ """10733 5.9 restartTime;
723
+ See ISO 8208 Section 4.1, table 26""",
724
+ }, # column
725
+ "x25OperCallTimer" : {
726
+ "nodetype" : "column",
727
+ "moduleName" : "RFC1382-MIB",
728
+ "oid" : "1.3.6.1.2.1.10.5.2.1.6",
729
+ "status" : "current",
730
+ "syntax" : {
731
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
732
+ },
733
+ "access" : "readonly",
734
+ "description" :
735
+ """The T21 Call timer in milliseconds.""",
736
+ "reference" :
737
+ """10733 callTime;
738
+ See ISO 8208 Section 5.2.1, table 26""",
739
+ }, # column
740
+ "x25OperResetTimer" : {
741
+ "nodetype" : "column",
742
+ "moduleName" : "RFC1382-MIB",
743
+ "oid" : "1.3.6.1.2.1.10.5.2.1.7",
744
+ "status" : "current",
745
+ "syntax" : {
746
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
747
+ },
748
+ "access" : "readonly",
749
+ "description" :
750
+ """The T22 Reset timer in milliseconds.""",
751
+ "reference" :
752
+ """10733 resetTime;
753
+ See ISO 8208 Section 8.1, table 26""",
754
+ }, # column
755
+ "x25OperClearTimer" : {
756
+ "nodetype" : "column",
757
+ "moduleName" : "RFC1382-MIB",
758
+ "oid" : "1.3.6.1.2.1.10.5.2.1.8",
759
+ "status" : "current",
760
+ "syntax" : {
761
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
762
+ },
763
+ "access" : "readonly",
764
+ "description" :
765
+ """The T23 Clear timer in milliseconds.""",
766
+ "reference" :
767
+ """10733 clearTime;
768
+ See ISO 8208 Section 5.5.1, table 26""",
769
+ }, # column
770
+ "x25OperWindowTimer" : {
771
+ "nodetype" : "column",
772
+ "moduleName" : "RFC1382-MIB",
773
+ "oid" : "1.3.6.1.2.1.10.5.2.1.9",
774
+ "status" : "current",
775
+ "syntax" : {
776
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
777
+ },
778
+ "access" : "readonly",
779
+ "description" :
780
+ """The T24 window status transmission timer
781
+ milliseconds. A value of 2147483647
782
+ indicates no window timer in use.""",
783
+ "reference" :
784
+ """10733 5.10.1 windowTime (opt);
785
+ See ISO 8208 Section 11.2.2, table 26""",
786
+ }, # column
787
+ "x25OperDataRxmtTimer" : {
788
+ "nodetype" : "column",
789
+ "moduleName" : "RFC1382-MIB",
790
+ "oid" : "1.3.6.1.2.1.10.5.2.1.10",
791
+ "status" : "current",
792
+ "syntax" : {
793
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
794
+ },
795
+ "access" : "readonly",
796
+ "description" :
797
+ """The T25 Data Retransmission timer in
798
+ milliseconds. A value of 2147483647
799
+ indicates no data retransmission timer in
800
+ use.""",
801
+ "reference" :
802
+ """10733 5.10.1 dataRetransmissionTime (opt);
803
+ See ISO 8208 Section 11.2.1, table 26""",
804
+ }, # column
805
+ "x25OperInterruptTimer" : {
806
+ "nodetype" : "column",
807
+ "moduleName" : "RFC1382-MIB",
808
+ "oid" : "1.3.6.1.2.1.10.5.2.1.11",
809
+ "status" : "current",
810
+ "syntax" : {
811
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
812
+ },
813
+ "access" : "readonly",
814
+ "description" :
815
+ """The T26 Interrupt timer in milliseconds. A
816
+ value of 2147483647 indicates interrupts are
817
+ not being used.""",
818
+ "reference" :
819
+ """10733 interruptTime;
820
+ See ISO 8208 Section 6.8.1, table 26""",
821
+ }, # column
822
+ "x25OperRejectTimer" : {
823
+ "nodetype" : "column",
824
+ "moduleName" : "RFC1382-MIB",
825
+ "oid" : "1.3.6.1.2.1.10.5.2.1.12",
826
+ "status" : "current",
827
+ "syntax" : {
828
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
829
+ },
830
+ "access" : "readonly",
831
+ "description" :
832
+ """The T27 Reject retransmission timer in
833
+ milliseconds. A value of 2147483647
834
+ indicates no reject timer in use.""",
835
+ "reference" :
836
+ """10733 5.10.1 dataRejectTime (opt);
837
+ See ISO 8208 Section 13.4.1, table 26""",
838
+ }, # column
839
+ "x25OperRegistrationRequestTimer" : {
840
+ "nodetype" : "column",
841
+ "moduleName" : "RFC1382-MIB",
842
+ "oid" : "1.3.6.1.2.1.10.5.2.1.13",
843
+ "status" : "current",
844
+ "syntax" : {
845
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
846
+ },
847
+ "access" : "readonly",
848
+ "description" :
849
+ """The T28 registration timer in milliseconds.
850
+ A value of 2147483647 indicates no
851
+ registration timer in use.""",
852
+ "reference" :
853
+ """10733 5.8.1 registrationRequestTime (opt);
854
+ See ISO 8208 Section 13.1.1.1, table 26""",
855
+ }, # column
856
+ "x25OperMinimumRecallTimer" : {
857
+ "nodetype" : "column",
858
+ "moduleName" : "RFC1382-MIB",
859
+ "oid" : "1.3.6.1.2.1.10.5.2.1.14",
860
+ "status" : "current",
861
+ "syntax" : {
862
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
863
+ },
864
+ "access" : "readonly",
865
+ "description" :
866
+ """Minimum time interval between unsuccessful
867
+ call attempts in milliseconds.""",
868
+ "reference" :
869
+ """10733 5.9 minimum RecallTimer""",
870
+ }, # column
871
+ "x25OperRestartCount" : {
872
+ "nodetype" : "column",
873
+ "moduleName" : "RFC1382-MIB",
874
+ "oid" : "1.3.6.1.2.1.10.5.2.1.15",
875
+ "status" : "current",
876
+ "syntax" : {
877
+ "type" : {
878
+ "basetype" : "Integer32",
879
+ "ranges" : [
880
+ {
881
+ "min" : "0",
882
+ "max" : "65535"
883
+ },
884
+ ],
885
+ "range" : {
886
+ "min" : "0",
887
+ "max" : "65535"
888
+ },
889
+ },
890
+ },
891
+ "access" : "readonly",
892
+ "description" :
893
+ """The R20 restart retransmission count.""",
894
+ "reference" :
895
+ """10733 5.9 restartCount
896
+ See ISO 8208 Section 4.1, table 27""",
897
+ }, # column
898
+ "x25OperResetCount" : {
899
+ "nodetype" : "column",
900
+ "moduleName" : "RFC1382-MIB",
901
+ "oid" : "1.3.6.1.2.1.10.5.2.1.16",
902
+ "status" : "current",
903
+ "syntax" : {
904
+ "type" : {
905
+ "basetype" : "Integer32",
906
+ "ranges" : [
907
+ {
908
+ "min" : "0",
909
+ "max" : "65535"
910
+ },
911
+ ],
912
+ "range" : {
913
+ "min" : "0",
914
+ "max" : "65535"
915
+ },
916
+ },
917
+ },
918
+ "access" : "readonly",
919
+ "description" :
920
+ """The r22 Reset retransmission count.""",
921
+ "reference" :
922
+ """10733 resetCount;
923
+ See section ISO 8208 8.1, table 27""",
924
+ }, # column
925
+ "x25OperClearCount" : {
926
+ "nodetype" : "column",
927
+ "moduleName" : "RFC1382-MIB",
928
+ "oid" : "1.3.6.1.2.1.10.5.2.1.17",
929
+ "status" : "current",
930
+ "syntax" : {
931
+ "type" : {
932
+ "basetype" : "Integer32",
933
+ "ranges" : [
934
+ {
935
+ "min" : "0",
936
+ "max" : "65535"
937
+ },
938
+ ],
939
+ "range" : {
940
+ "min" : "0",
941
+ "max" : "65535"
942
+ },
943
+ },
944
+ },
945
+ "access" : "readonly",
946
+ "description" :
947
+ """The r23 Clear retransmission count.""",
948
+ "reference" :
949
+ """10733 clearCount;
950
+ See ISO 8208 Section 5.5.1, table 27""",
951
+ }, # column
952
+ "x25OperDataRxmtCount" : {
953
+ "nodetype" : "column",
954
+ "moduleName" : "RFC1382-MIB",
955
+ "oid" : "1.3.6.1.2.1.10.5.2.1.18",
956
+ "status" : "current",
957
+ "syntax" : {
958
+ "type" : {
959
+ "basetype" : "Integer32",
960
+ "ranges" : [
961
+ {
962
+ "min" : "0",
963
+ "max" : "65535"
964
+ },
965
+ ],
966
+ "range" : {
967
+ "min" : "0",
968
+ "max" : "65535"
969
+ },
970
+ },
971
+ },
972
+ "access" : "readonly",
973
+ "description" :
974
+ """The R25 Data retransmission count. This
975
+ value is undefined if the
976
+ x25OperDataRxmtTimer indicates no timer in
977
+ use.""",
978
+ "reference" :
979
+ """10733 5.10.1 dataRetransmissionCount (opt);
980
+ See ISO 8208 Section 11.2.1, table 27""",
981
+ }, # column
982
+ "x25OperRejectCount" : {
983
+ "nodetype" : "column",
984
+ "moduleName" : "RFC1382-MIB",
985
+ "oid" : "1.3.6.1.2.1.10.5.2.1.19",
986
+ "status" : "current",
987
+ "syntax" : {
988
+ "type" : {
989
+ "basetype" : "Integer32",
990
+ "ranges" : [
991
+ {
992
+ "min" : "0",
993
+ "max" : "65535"
994
+ },
995
+ ],
996
+ "range" : {
997
+ "min" : "0",
998
+ "max" : "65535"
999
+ },
1000
+ },
1001
+ },
1002
+ "access" : "readonly",
1003
+ "description" :
1004
+ """The R27 reject retransmission count. This
1005
+ value is undefined if the x25OperRejectTimer
1006
+ indicates no timer in use.""",
1007
+ "reference" :
1008
+ """10733 5.10.1 dataRejectCount (opt)""",
1009
+ }, # column
1010
+ "x25OperRegistrationRequestCount" : {
1011
+ "nodetype" : "column",
1012
+ "moduleName" : "RFC1382-MIB",
1013
+ "oid" : "1.3.6.1.2.1.10.5.2.1.20",
1014
+ "status" : "current",
1015
+ "syntax" : {
1016
+ "type" : {
1017
+ "basetype" : "Integer32",
1018
+ "ranges" : [
1019
+ {
1020
+ "min" : "0",
1021
+ "max" : "65535"
1022
+ },
1023
+ ],
1024
+ "range" : {
1025
+ "min" : "0",
1026
+ "max" : "65535"
1027
+ },
1028
+ },
1029
+ },
1030
+ "access" : "readonly",
1031
+ "description" :
1032
+ """The R28 Registration retransmission Count.
1033
+ This value is undefined if the
1034
+ x25OperREgistrationRequestTimer indicates no
1035
+ timer in use.""",
1036
+ "reference" :
1037
+ """10733 5.8.1 registrationRequestCount (opt);
1038
+ See ISO 8208 Section 13.1.1.1, table 27""",
1039
+ }, # column
1040
+ "x25OperNumberPVCs" : {
1041
+ "nodetype" : "column",
1042
+ "moduleName" : "RFC1382-MIB",
1043
+ "oid" : "1.3.6.1.2.1.10.5.2.1.21",
1044
+ "status" : "current",
1045
+ "syntax" : {
1046
+ "type" : {
1047
+ "basetype" : "Integer32",
1048
+ "ranges" : [
1049
+ {
1050
+ "min" : "0",
1051
+ "max" : "4096"
1052
+ },
1053
+ ],
1054
+ "range" : {
1055
+ "min" : "0",
1056
+ "max" : "4096"
1057
+ },
1058
+ },
1059
+ },
1060
+ "access" : "readonly",
1061
+ "description" :
1062
+ """The number of PVC configured for this PLE.
1063
+ The PVCs use channel numbers from 1 to this
1064
+ number.""",
1065
+ }, # column
1066
+ "x25OperDefCallParamId" : {
1067
+ "nodetype" : "column",
1068
+ "moduleName" : "RFC1382-MIB",
1069
+ "oid" : "1.3.6.1.2.1.10.5.2.1.22",
1070
+ "status" : "current",
1071
+ "syntax" : {
1072
+ "type" : { "module" :"", "name" : "ObjectIdentifier"},
1073
+ },
1074
+ "access" : "readonly",
1075
+ "description" :
1076
+ """This identifies the instance of the
1077
+ x25CallParmIndex for the entry in the
1078
+ x25CallParmTable that contains the default
1079
+ call parameters for this PLE.""",
1080
+ }, # column
1081
+ "x25OperLocalAddress" : {
1082
+ "nodetype" : "column",
1083
+ "moduleName" : "RFC1382-MIB",
1084
+ "oid" : "1.3.6.1.2.1.10.5.2.1.23",
1085
+ "status" : "current",
1086
+ "syntax" : {
1087
+ "type" : { "module" :"RFC1382-MIB", "name" : "X121Address"},
1088
+ },
1089
+ "access" : "readonly",
1090
+ "description" :
1091
+ """The local address for this PLE subnetwork.
1092
+ A zero length address maybe returned by PLEs
1093
+ that only support PVCs.""",
1094
+ "reference" :
1095
+ """10733 5.9 localDTEAddress""",
1096
+ }, # column
1097
+ "x25OperDataLinkId" : {
1098
+ "nodetype" : "column",
1099
+ "moduleName" : "RFC1382-MIB",
1100
+ "oid" : "1.3.6.1.2.1.10.5.2.1.24",
1101
+ "status" : "current",
1102
+ "syntax" : {
1103
+ "type" : { "module" :"", "name" : "ObjectIdentifier"},
1104
+ },
1105
+ "access" : "readonly",
1106
+ "description" :
1107
+ """This identifies the instance of the index
1108
+ object in the first table of the most device
1109
+ specific MIB for the interface used by this
1110
+ PLE.""",
1111
+ }, # column
1112
+ "x25OperProtocolVersionSupported" : {
1113
+ "nodetype" : "column",
1114
+ "moduleName" : "RFC1382-MIB",
1115
+ "oid" : "1.3.6.1.2.1.10.5.2.1.25",
1116
+ "status" : "current",
1117
+ "syntax" : {
1118
+ "type" : { "module" :"", "name" : "ObjectIdentifier"},
1119
+ },
1120
+ "access" : "readonly",
1121
+ "description" :
1122
+ """Identifies the version of the X.25 protocol
1123
+ this interface supports. Object identifiers
1124
+ for common versions are defined below in the
1125
+ x25ProtocolVersion subtree.""",
1126
+ "reference" :
1127
+ """10733 5.9 protocolVersionSupported""",
1128
+ }, # column
1129
+ "x25StatTable" : {
1130
+ "nodetype" : "table",
1131
+ "moduleName" : "RFC1382-MIB",
1132
+ "oid" : "1.3.6.1.2.1.10.5.3",
1133
+ "status" : "current",
1134
+ "description" :
1135
+ """Statistics information about this X.25
1136
+ PLE.""",
1137
+ }, # table
1138
+ "x25StatEntry" : {
1139
+ "nodetype" : "row",
1140
+ "moduleName" : "RFC1382-MIB",
1141
+ "oid" : "1.3.6.1.2.1.10.5.3.1",
1142
+ "status" : "current",
1143
+ "linkage" : [
1144
+ "x25StatIndex",
1145
+ ],
1146
+ "description" :
1147
+ """Entries of the x25StatTable.""",
1148
+ }, # row
1149
+ "x25StatIndex" : {
1150
+ "nodetype" : "column",
1151
+ "moduleName" : "RFC1382-MIB",
1152
+ "oid" : "1.3.6.1.2.1.10.5.3.1.1",
1153
+ "status" : "current",
1154
+ "syntax" : {
1155
+ "type" : { "module" :"RFC1381-MIB", "name" : "IfIndexType"},
1156
+ },
1157
+ "access" : "readonly",
1158
+ "description" :
1159
+ """The ifIndex value for the X.25 interface.""",
1160
+ }, # column
1161
+ "x25StatInCalls" : {
1162
+ "nodetype" : "column",
1163
+ "moduleName" : "RFC1382-MIB",
1164
+ "oid" : "1.3.6.1.2.1.10.5.3.1.2",
1165
+ "status" : "current",
1166
+ "syntax" : {
1167
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1168
+ },
1169
+ "access" : "readonly",
1170
+ "description" :
1171
+ """The number of incoming calls received.""",
1172
+ }, # column
1173
+ "x25StatInCallRefusals" : {
1174
+ "nodetype" : "column",
1175
+ "moduleName" : "RFC1382-MIB",
1176
+ "oid" : "1.3.6.1.2.1.10.5.3.1.3",
1177
+ "status" : "current",
1178
+ "syntax" : {
1179
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1180
+ },
1181
+ "access" : "readonly",
1182
+ "description" :
1183
+ """The number of incoming calls refused. This
1184
+ includes calls refused by the PLE and by
1185
+ higher layers. This also includes calls
1186
+ cleared because of restricted fast select.""",
1187
+ }, # column
1188
+ "x25StatInProviderInitiatedClears" : {
1189
+ "nodetype" : "column",
1190
+ "moduleName" : "RFC1382-MIB",
1191
+ "oid" : "1.3.6.1.2.1.10.5.3.1.4",
1192
+ "status" : "current",
1193
+ "syntax" : {
1194
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1195
+ },
1196
+ "access" : "readonly",
1197
+ "description" :
1198
+ """The number of clear requests with a cause
1199
+ code other than DTE initiated.""",
1200
+ "reference" :
1201
+ """10733 providerInitiatedDisconnect""",
1202
+ }, # column
1203
+ "x25StatInRemotelyInitiatedResets" : {
1204
+ "nodetype" : "column",
1205
+ "moduleName" : "RFC1382-MIB",
1206
+ "oid" : "1.3.6.1.2.1.10.5.3.1.5",
1207
+ "status" : "current",
1208
+ "syntax" : {
1209
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1210
+ },
1211
+ "access" : "readonly",
1212
+ "description" :
1213
+ """The number of reset requests received with
1214
+ cause code DTE initiated.""",
1215
+ "reference" :
1216
+ """10733 remotelyInitiatedResets""",
1217
+ }, # column
1218
+ "x25StatInProviderInitiatedResets" : {
1219
+ "nodetype" : "column",
1220
+ "moduleName" : "RFC1382-MIB",
1221
+ "oid" : "1.3.6.1.2.1.10.5.3.1.6",
1222
+ "status" : "current",
1223
+ "syntax" : {
1224
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1225
+ },
1226
+ "access" : "readonly",
1227
+ "description" :
1228
+ """The number of reset requests received with
1229
+ cause code other than DTE initiated.""",
1230
+ "reference" :
1231
+ """10733 ProviderInitiatedResets""",
1232
+ }, # column
1233
+ "x25StatInRestarts" : {
1234
+ "nodetype" : "column",
1235
+ "moduleName" : "RFC1382-MIB",
1236
+ "oid" : "1.3.6.1.2.1.10.5.3.1.7",
1237
+ "status" : "current",
1238
+ "syntax" : {
1239
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1240
+ },
1241
+ "access" : "readonly",
1242
+ "description" :
1243
+ """The number of remotely initiated (including
1244
+ provider initiated) restarts experienced by
1245
+ the PLE excluding the restart associated
1246
+ with bringing up the PLE interface. This
1247
+ only counts restarts received when the PLE
1248
+ already has an established connection with
1249
+ the remove PLE.""",
1250
+ "reference" :
1251
+ """10733 5.9 remotelyInitiatedRestarts""",
1252
+ }, # column
1253
+ "x25StatInDataPackets" : {
1254
+ "nodetype" : "column",
1255
+ "moduleName" : "RFC1382-MIB",
1256
+ "oid" : "1.3.6.1.2.1.10.5.3.1.8",
1257
+ "status" : "current",
1258
+ "syntax" : {
1259
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1260
+ },
1261
+ "access" : "readonly",
1262
+ "description" :
1263
+ """The number of data packets received.""",
1264
+ "reference" :
1265
+ """10733 5.9 dataPacketsReceived.""",
1266
+ }, # column
1267
+ "x25StatInAccusedOfProtocolErrors" : {
1268
+ "nodetype" : "column",
1269
+ "moduleName" : "RFC1382-MIB",
1270
+ "oid" : "1.3.6.1.2.1.10.5.3.1.9",
1271
+ "status" : "current",
1272
+ "syntax" : {
1273
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1274
+ },
1275
+ "access" : "readonly",
1276
+ "description" :
1277
+ """The number of packets received containing a
1278
+ procedure error cause code. These include
1279
+ clear, reset, restart, or diagnostic
1280
+ packets.""",
1281
+ "reference" :
1282
+ """CD 10733 5.9 accusedOfProtocolError""",
1283
+ }, # column
1284
+ "x25StatInInterrupts" : {
1285
+ "nodetype" : "column",
1286
+ "moduleName" : "RFC1382-MIB",
1287
+ "oid" : "1.3.6.1.2.1.10.5.3.1.10",
1288
+ "status" : "current",
1289
+ "syntax" : {
1290
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1291
+ },
1292
+ "access" : "readonly",
1293
+ "description" :
1294
+ """The number of interrupt packets received by
1295
+ the PLE or over the PVC/VC.""",
1296
+ "reference" :
1297
+ """10733 interruptPacketsReceived""",
1298
+ }, # column
1299
+ "x25StatOutCallAttempts" : {
1300
+ "nodetype" : "column",
1301
+ "moduleName" : "RFC1382-MIB",
1302
+ "oid" : "1.3.6.1.2.1.10.5.3.1.11",
1303
+ "status" : "current",
1304
+ "syntax" : {
1305
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1306
+ },
1307
+ "access" : "readonly",
1308
+ "description" :
1309
+ """The number of calls attempted.""",
1310
+ "reference" :
1311
+ """10733 5.9 callAttempts""",
1312
+ }, # column
1313
+ "x25StatOutCallFailures" : {
1314
+ "nodetype" : "column",
1315
+ "moduleName" : "RFC1382-MIB",
1316
+ "oid" : "1.3.6.1.2.1.10.5.3.1.12",
1317
+ "status" : "current",
1318
+ "syntax" : {
1319
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1320
+ },
1321
+ "access" : "readonly",
1322
+ "description" :
1323
+ """The number of call attempts which failed.
1324
+ This includes calls that were cleared
1325
+ because of restrictive fast select.""",
1326
+ }, # column
1327
+ "x25StatOutInterrupts" : {
1328
+ "nodetype" : "column",
1329
+ "moduleName" : "RFC1382-MIB",
1330
+ "oid" : "1.3.6.1.2.1.10.5.3.1.13",
1331
+ "status" : "current",
1332
+ "syntax" : {
1333
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1334
+ },
1335
+ "access" : "readonly",
1336
+ "description" :
1337
+ """The number of interrupt packets send by the
1338
+ PLE or over the PVC/VC.""",
1339
+ "reference" :
1340
+ """10733 InterruptPacketsSent""",
1341
+ }, # column
1342
+ "x25StatOutDataPackets" : {
1343
+ "nodetype" : "column",
1344
+ "moduleName" : "RFC1382-MIB",
1345
+ "oid" : "1.3.6.1.2.1.10.5.3.1.14",
1346
+ "status" : "current",
1347
+ "syntax" : {
1348
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1349
+ },
1350
+ "access" : "readonly",
1351
+ "description" :
1352
+ """The number of data packets sent by this
1353
+ PLE.""",
1354
+ "reference" :
1355
+ """10733 dataPacketSent""",
1356
+ }, # column
1357
+ "x25StatOutgoingCircuits" : {
1358
+ "nodetype" : "column",
1359
+ "moduleName" : "RFC1382-MIB",
1360
+ "oid" : "1.3.6.1.2.1.10.5.3.1.15",
1361
+ "status" : "current",
1362
+ "syntax" : {
1363
+ "type" : { "module" :"RFC1155-SMI", "name" : "Gauge"},
1364
+ },
1365
+ "access" : "readonly",
1366
+ "description" :
1367
+ """The number of active outgoing circuits.
1368
+ This includes call requests sent but not yet
1369
+ confirmed. This does not count PVCs.""",
1370
+ }, # column
1371
+ "x25StatIncomingCircuits" : {
1372
+ "nodetype" : "column",
1373
+ "moduleName" : "RFC1382-MIB",
1374
+ "oid" : "1.3.6.1.2.1.10.5.3.1.16",
1375
+ "status" : "current",
1376
+ "syntax" : {
1377
+ "type" : { "module" :"RFC1155-SMI", "name" : "Gauge"},
1378
+ },
1379
+ "access" : "readonly",
1380
+ "description" :
1381
+ """The number of active Incoming Circuits.
1382
+ This includes call indications received but
1383
+ not yet acknowledged. This does not count
1384
+ PVCs.""",
1385
+ }, # column
1386
+ "x25StatTwowayCircuits" : {
1387
+ "nodetype" : "column",
1388
+ "moduleName" : "RFC1382-MIB",
1389
+ "oid" : "1.3.6.1.2.1.10.5.3.1.17",
1390
+ "status" : "current",
1391
+ "syntax" : {
1392
+ "type" : { "module" :"RFC1155-SMI", "name" : "Gauge"},
1393
+ },
1394
+ "access" : "readonly",
1395
+ "description" :
1396
+ """The number of active two-way Circuits.
1397
+ This includes call requests sent but not yet
1398
+ confirmed. This does not count PVCs.""",
1399
+ }, # column
1400
+ "x25StatRestartTimeouts" : {
1401
+ "nodetype" : "column",
1402
+ "moduleName" : "RFC1382-MIB",
1403
+ "oid" : "1.3.6.1.2.1.10.5.3.1.18",
1404
+ "status" : "current",
1405
+ "syntax" : {
1406
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1407
+ },
1408
+ "access" : "readonly",
1409
+ "description" :
1410
+ """The number of times the T20 restart timer
1411
+ expired.""",
1412
+ "reference" :
1413
+ """10733 5.9 restartTimeouts""",
1414
+ }, # column
1415
+ "x25StatCallTimeouts" : {
1416
+ "nodetype" : "column",
1417
+ "moduleName" : "RFC1382-MIB",
1418
+ "oid" : "1.3.6.1.2.1.10.5.3.1.19",
1419
+ "status" : "current",
1420
+ "syntax" : {
1421
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1422
+ },
1423
+ "access" : "readonly",
1424
+ "description" :
1425
+ """The number of times the T21 call timer
1426
+ expired.""",
1427
+ "reference" :
1428
+ """10733 5.9 callTimeouts""",
1429
+ }, # column
1430
+ "x25StatResetTimeouts" : {
1431
+ "nodetype" : "column",
1432
+ "moduleName" : "RFC1382-MIB",
1433
+ "oid" : "1.3.6.1.2.1.10.5.3.1.20",
1434
+ "status" : "current",
1435
+ "syntax" : {
1436
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1437
+ },
1438
+ "access" : "readonly",
1439
+ "description" :
1440
+ """The number of times the T22 reset timer
1441
+ expired.""",
1442
+ "reference" :
1443
+ """10733 5.9 resetTimeouts""",
1444
+ }, # column
1445
+ "x25StatClearTimeouts" : {
1446
+ "nodetype" : "column",
1447
+ "moduleName" : "RFC1382-MIB",
1448
+ "oid" : "1.3.6.1.2.1.10.5.3.1.21",
1449
+ "status" : "current",
1450
+ "syntax" : {
1451
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1452
+ },
1453
+ "access" : "readonly",
1454
+ "description" :
1455
+ """The number of times the T23 clear timer
1456
+ expired.""",
1457
+ "reference" :
1458
+ """10733 5.9 clearTimeouts""",
1459
+ }, # column
1460
+ "x25StatDataRxmtTimeouts" : {
1461
+ "nodetype" : "column",
1462
+ "moduleName" : "RFC1382-MIB",
1463
+ "oid" : "1.3.6.1.2.1.10.5.3.1.22",
1464
+ "status" : "current",
1465
+ "syntax" : {
1466
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1467
+ },
1468
+ "access" : "readonly",
1469
+ "description" :
1470
+ """The number of times the T25 data timer
1471
+ expired.""",
1472
+ "reference" :
1473
+ """10733 5.9 dataRetransmissionsTimerExpiries""",
1474
+ }, # column
1475
+ "x25StatInterruptTimeouts" : {
1476
+ "nodetype" : "column",
1477
+ "moduleName" : "RFC1382-MIB",
1478
+ "oid" : "1.3.6.1.2.1.10.5.3.1.23",
1479
+ "status" : "current",
1480
+ "syntax" : {
1481
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1482
+ },
1483
+ "access" : "readonly",
1484
+ "description" :
1485
+ """The number of times the T26 interrupt timer
1486
+ expired.""",
1487
+ "reference" :
1488
+ """10733 5.9 interruptTimerExpires""",
1489
+ }, # column
1490
+ "x25StatRetryCountExceededs" : {
1491
+ "nodetype" : "column",
1492
+ "moduleName" : "RFC1382-MIB",
1493
+ "oid" : "1.3.6.1.2.1.10.5.3.1.24",
1494
+ "status" : "current",
1495
+ "syntax" : {
1496
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1497
+ },
1498
+ "access" : "readonly",
1499
+ "description" :
1500
+ """The number of times a retry counter was
1501
+ exhausted.""",
1502
+ "reference" :
1503
+ """10733 5.9 retryCountsExceeded""",
1504
+ }, # column
1505
+ "x25StatClearCountExceededs" : {
1506
+ "nodetype" : "column",
1507
+ "moduleName" : "RFC1382-MIB",
1508
+ "oid" : "1.3.6.1.2.1.10.5.3.1.25",
1509
+ "status" : "current",
1510
+ "syntax" : {
1511
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1512
+ },
1513
+ "access" : "readonly",
1514
+ "description" :
1515
+ """The number of times the R23 clear count was
1516
+ exceeded.""",
1517
+ "reference" :
1518
+ """10733 5.9 clearCountsExceeded""",
1519
+ }, # column
1520
+ "x25ChannelTable" : {
1521
+ "nodetype" : "table",
1522
+ "moduleName" : "RFC1382-MIB",
1523
+ "oid" : "1.3.6.1.2.1.10.5.4",
1524
+ "status" : "current",
1525
+ "description" :
1526
+ """These objects contain information about the
1527
+ channel number configuration in an X.25 PLE.
1528
+ These values are the configured values.
1529
+ changes in these values after the interfaces
1530
+ has started may not be reflected in the
1531
+ operating PLE.""",
1532
+ "reference" :
1533
+ """See ISO 8208, Section 3.7""",
1534
+ }, # table
1535
+ "x25ChannelEntry" : {
1536
+ "nodetype" : "row",
1537
+ "moduleName" : "RFC1382-MIB",
1538
+ "oid" : "1.3.6.1.2.1.10.5.4.1",
1539
+ "status" : "current",
1540
+ "linkage" : [
1541
+ "x25ChannelIndex",
1542
+ ],
1543
+ "description" :
1544
+ """Entries of x25ChannelTable.""",
1545
+ "reference" :
1546
+ """This provides the information available
1547
+ in 10733 logicalChannelAssignments.""",
1548
+ }, # row
1549
+ "x25ChannelIndex" : {
1550
+ "nodetype" : "column",
1551
+ "moduleName" : "RFC1382-MIB",
1552
+ "oid" : "1.3.6.1.2.1.10.5.4.1.1",
1553
+ "status" : "current",
1554
+ "syntax" : {
1555
+ "type" : { "module" :"RFC1381-MIB", "name" : "IfIndexType"},
1556
+ },
1557
+ "access" : "readonly",
1558
+ "description" :
1559
+ """The ifIndex value for the X.25 Interface.""",
1560
+ }, # column
1561
+ "x25ChannelLIC" : {
1562
+ "nodetype" : "column",
1563
+ "moduleName" : "RFC1382-MIB",
1564
+ "oid" : "1.3.6.1.2.1.10.5.4.1.2",
1565
+ "status" : "current",
1566
+ "syntax" : {
1567
+ "type" : {
1568
+ "basetype" : "Integer32",
1569
+ "ranges" : [
1570
+ {
1571
+ "min" : "0",
1572
+ "max" : "4095"
1573
+ },
1574
+ ],
1575
+ "range" : {
1576
+ "min" : "0",
1577
+ "max" : "4095"
1578
+ },
1579
+ },
1580
+ },
1581
+ "access" : "readwrite",
1582
+ "description" :
1583
+ """Lowest Incoming channel.""",
1584
+ }, # column
1585
+ "x25ChannelHIC" : {
1586
+ "nodetype" : "column",
1587
+ "moduleName" : "RFC1382-MIB",
1588
+ "oid" : "1.3.6.1.2.1.10.5.4.1.3",
1589
+ "status" : "current",
1590
+ "syntax" : {
1591
+ "type" : {
1592
+ "basetype" : "Integer32",
1593
+ "ranges" : [
1594
+ {
1595
+ "min" : "0",
1596
+ "max" : "4095"
1597
+ },
1598
+ ],
1599
+ "range" : {
1600
+ "min" : "0",
1601
+ "max" : "4095"
1602
+ },
1603
+ },
1604
+ },
1605
+ "access" : "readwrite",
1606
+ "description" :
1607
+ """Highest Incoming channel. A value of zero
1608
+ indicates no channels in this range.""",
1609
+ }, # column
1610
+ "x25ChannelLTC" : {
1611
+ "nodetype" : "column",
1612
+ "moduleName" : "RFC1382-MIB",
1613
+ "oid" : "1.3.6.1.2.1.10.5.4.1.4",
1614
+ "status" : "current",
1615
+ "syntax" : {
1616
+ "type" : {
1617
+ "basetype" : "Integer32",
1618
+ "ranges" : [
1619
+ {
1620
+ "min" : "0",
1621
+ "max" : "4095"
1622
+ },
1623
+ ],
1624
+ "range" : {
1625
+ "min" : "0",
1626
+ "max" : "4095"
1627
+ },
1628
+ },
1629
+ },
1630
+ "access" : "readwrite",
1631
+ "description" :
1632
+ """Lowest Two-way channel.""",
1633
+ }, # column
1634
+ "x25ChannelHTC" : {
1635
+ "nodetype" : "column",
1636
+ "moduleName" : "RFC1382-MIB",
1637
+ "oid" : "1.3.6.1.2.1.10.5.4.1.5",
1638
+ "status" : "current",
1639
+ "syntax" : {
1640
+ "type" : {
1641
+ "basetype" : "Integer32",
1642
+ "ranges" : [
1643
+ {
1644
+ "min" : "0",
1645
+ "max" : "4095"
1646
+ },
1647
+ ],
1648
+ "range" : {
1649
+ "min" : "0",
1650
+ "max" : "4095"
1651
+ },
1652
+ },
1653
+ },
1654
+ "access" : "readwrite",
1655
+ "description" :
1656
+ """Highest Two-way channel. A value of zero
1657
+ indicates no channels in this range.""",
1658
+ }, # column
1659
+ "x25ChannelLOC" : {
1660
+ "nodetype" : "column",
1661
+ "moduleName" : "RFC1382-MIB",
1662
+ "oid" : "1.3.6.1.2.1.10.5.4.1.6",
1663
+ "status" : "current",
1664
+ "syntax" : {
1665
+ "type" : {
1666
+ "basetype" : "Integer32",
1667
+ "ranges" : [
1668
+ {
1669
+ "min" : "0",
1670
+ "max" : "4095"
1671
+ },
1672
+ ],
1673
+ "range" : {
1674
+ "min" : "0",
1675
+ "max" : "4095"
1676
+ },
1677
+ },
1678
+ },
1679
+ "access" : "readwrite",
1680
+ "description" :
1681
+ """Lowest outgoing channel.""",
1682
+ }, # column
1683
+ "x25ChannelHOC" : {
1684
+ "nodetype" : "column",
1685
+ "moduleName" : "RFC1382-MIB",
1686
+ "oid" : "1.3.6.1.2.1.10.5.4.1.7",
1687
+ "status" : "current",
1688
+ "syntax" : {
1689
+ "type" : {
1690
+ "basetype" : "Integer32",
1691
+ "ranges" : [
1692
+ {
1693
+ "min" : "0",
1694
+ "max" : "4095"
1695
+ },
1696
+ ],
1697
+ "range" : {
1698
+ "min" : "0",
1699
+ "max" : "4095"
1700
+ },
1701
+ },
1702
+ },
1703
+ "access" : "readwrite",
1704
+ "description" :
1705
+ """Highest outgoing channel. A value of zero
1706
+ indicates no channels in this range.""",
1707
+ }, # column
1708
+ "x25CircuitTable" : {
1709
+ "nodetype" : "table",
1710
+ "moduleName" : "RFC1382-MIB",
1711
+ "oid" : "1.3.6.1.2.1.10.5.5",
1712
+ "status" : "current",
1713
+ "description" :
1714
+ """These objects contain general information
1715
+ about a specific circuit of an X.25 PLE.""",
1716
+ }, # table
1717
+ "x25CircuitEntry" : {
1718
+ "nodetype" : "row",
1719
+ "moduleName" : "RFC1382-MIB",
1720
+ "oid" : "1.3.6.1.2.1.10.5.5.1",
1721
+ "status" : "current",
1722
+ "linkage" : [
1723
+ "x25CircuitIndex",
1724
+ "x25CircuitChannel",
1725
+ ],
1726
+ "description" :
1727
+ """Entries of x25CircuitTable.""",
1728
+ }, # row
1729
+ "x25CircuitIndex" : {
1730
+ "nodetype" : "column",
1731
+ "moduleName" : "RFC1382-MIB",
1732
+ "oid" : "1.3.6.1.2.1.10.5.5.1.1",
1733
+ "status" : "current",
1734
+ "syntax" : {
1735
+ "type" : { "module" :"RFC1381-MIB", "name" : "IfIndexType"},
1736
+ },
1737
+ "access" : "readonly",
1738
+ "description" :
1739
+ """The ifIndex value for the X.25 Interface.""",
1740
+ }, # column
1741
+ "x25CircuitChannel" : {
1742
+ "nodetype" : "column",
1743
+ "moduleName" : "RFC1382-MIB",
1744
+ "oid" : "1.3.6.1.2.1.10.5.5.1.2",
1745
+ "status" : "current",
1746
+ "syntax" : {
1747
+ "type" : {
1748
+ "basetype" : "Integer32",
1749
+ "ranges" : [
1750
+ {
1751
+ "min" : "0",
1752
+ "max" : "4095"
1753
+ },
1754
+ ],
1755
+ "range" : {
1756
+ "min" : "0",
1757
+ "max" : "4095"
1758
+ },
1759
+ },
1760
+ },
1761
+ "access" : "readonly",
1762
+ "description" :
1763
+ """The channel number for this circuit.""",
1764
+ }, # column
1765
+ "x25CircuitStatus" : {
1766
+ "nodetype" : "column",
1767
+ "moduleName" : "RFC1382-MIB",
1768
+ "oid" : "1.3.6.1.2.1.10.5.5.1.3",
1769
+ "status" : "current",
1770
+ "syntax" : {
1771
+ "type" : {
1772
+ "basetype" : "Enumeration",
1773
+ "invalid" : {
1774
+ "nodetype" : "namednumber",
1775
+ "number" : "1"
1776
+ },
1777
+ "closed" : {
1778
+ "nodetype" : "namednumber",
1779
+ "number" : "2"
1780
+ },
1781
+ "calling" : {
1782
+ "nodetype" : "namednumber",
1783
+ "number" : "3"
1784
+ },
1785
+ "open" : {
1786
+ "nodetype" : "namednumber",
1787
+ "number" : "4"
1788
+ },
1789
+ "clearing" : {
1790
+ "nodetype" : "namednumber",
1791
+ "number" : "5"
1792
+ },
1793
+ "pvc" : {
1794
+ "nodetype" : "namednumber",
1795
+ "number" : "6"
1796
+ },
1797
+ "pvcResetting" : {
1798
+ "nodetype" : "namednumber",
1799
+ "number" : "7"
1800
+ },
1801
+ "startClear" : {
1802
+ "nodetype" : "namednumber",
1803
+ "number" : "8"
1804
+ },
1805
+ "startPvcResetting" : {
1806
+ "nodetype" : "namednumber",
1807
+ "number" : "9"
1808
+ },
1809
+ "other" : {
1810
+ "nodetype" : "namednumber",
1811
+ "number" : "10"
1812
+ },
1813
+ },
1814
+ },
1815
+ "access" : "readwrite",
1816
+ "description" :
1817
+ """This object reports the current status of
1818
+ the circuit.
1819
+
1820
+ An existing instance of this object can only
1821
+ be set to startClear, startPvcResetting, or
1822
+ invalid. An instance with the value calling
1823
+ or open can only be set to startClear and
1824
+ that action will start clearing the circuit.
1825
+ An instance with the value PVC can only be
1826
+ set to startPvcResetting or invalid and that
1827
+ action resets the PVC or deletes the circuit
1828
+ respectively. The values startClear or
1829
+ startPvcResetting will never be returned by
1830
+ an agent. An attempt to set the status of
1831
+ an existing instance to a value other than
1832
+ one of these values will result in an error.
1833
+
1834
+ A non-existing instance can be set to PVC to
1835
+ create a PVC if the implementation supports
1836
+ dynamic creation of PVCs. Some
1837
+ implementations may only allow creation and
1838
+ deletion of PVCs if the interface is down.
1839
+ Since the instance identifier will supply
1840
+ the PLE index and the channel number,
1841
+ setting this object alone supplies
1842
+ sufficient information to create the
1843
+ instance. All the DEFVAL clauses for the
1844
+ other objects of this table are appropriate
1845
+ for creating a PVC; PLEs creating entries
1846
+ for placed or accepted calls will use values
1847
+ appropriate for the call rather than the
1848
+ value of the DEFVAL clause. Two managers
1849
+ trying to create the same PVC can determine
1850
+ from the return code which manager succeeded
1851
+ and which failed (the failing manager fails
1852
+ because it can not set a value of PVC for an
1853
+ existing object).
1854
+ An entry in the closed or invalid state may
1855
+ be deleted or reused at the agent's
1856
+ convence. If the entry is kept in the
1857
+ closed state, the values of the parameters
1858
+ associated with the entry must be correct.
1859
+ Closed implies the values in the circuit
1860
+ table are correct.
1861
+
1862
+ The value of invalid indicates the other
1863
+ values in the table are invalid. Many
1864
+ agents may never return a value of invalid
1865
+ because they dynamically allocate and free
1866
+ unused table entries. An agent for a
1867
+ statically configured systems can return
1868
+ invalid to indicate the entry has not yet
1869
+ been used so the counters contain no
1870
+ information.""",
1871
+ "reference" :
1872
+ """See ISO 8208,
1873
+ table 33 for (p<n>) state table""",
1874
+ }, # column
1875
+ "x25CircuitEstablishTime" : {
1876
+ "nodetype" : "column",
1877
+ "moduleName" : "RFC1382-MIB",
1878
+ "oid" : "1.3.6.1.2.1.10.5.5.1.4",
1879
+ "status" : "current",
1880
+ "syntax" : {
1881
+ "type" : { "module" :"RFC1155-SMI", "name" : "TimeTicks"},
1882
+ },
1883
+ "access" : "readonly",
1884
+ "description" :
1885
+ """The value of sysUpTime when the channel was
1886
+ associated with this circuit. For outgoing
1887
+ SVCs, this is the time the first call packet
1888
+ was sent. For incoming SVCs, this is the
1889
+ time the call indication was received. For
1890
+ PVCs this is the time the PVC was able to
1891
+ pass data to a higher layer entity without
1892
+ loss of data.""",
1893
+ }, # column
1894
+ "x25CircuitDirection" : {
1895
+ "nodetype" : "column",
1896
+ "moduleName" : "RFC1382-MIB",
1897
+ "oid" : "1.3.6.1.2.1.10.5.5.1.5",
1898
+ "status" : "current",
1899
+ "syntax" : {
1900
+ "type" : {
1901
+ "basetype" : "Enumeration",
1902
+ "incoming" : {
1903
+ "nodetype" : "namednumber",
1904
+ "number" : "1"
1905
+ },
1906
+ "outgoing" : {
1907
+ "nodetype" : "namednumber",
1908
+ "number" : "2"
1909
+ },
1910
+ "pvc" : {
1911
+ "nodetype" : "namednumber",
1912
+ "number" : "3"
1913
+ },
1914
+ },
1915
+ },
1916
+ "access" : "readwrite",
1917
+ "default" : "pvc",
1918
+ "description" :
1919
+ """The direction of the call that established
1920
+ this circuit.""",
1921
+ "reference" :
1922
+ """10733 direction""",
1923
+ }, # column
1924
+ "x25CircuitInOctets" : {
1925
+ "nodetype" : "column",
1926
+ "moduleName" : "RFC1382-MIB",
1927
+ "oid" : "1.3.6.1.2.1.10.5.5.1.6",
1928
+ "status" : "current",
1929
+ "syntax" : {
1930
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1931
+ },
1932
+ "access" : "readonly",
1933
+ "description" :
1934
+ """The number of octets of user data delivered
1935
+ to upper layer.""",
1936
+ "reference" :
1937
+ """5.11 octetsReceivedCounter""",
1938
+ }, # column
1939
+ "x25CircuitInPdus" : {
1940
+ "nodetype" : "column",
1941
+ "moduleName" : "RFC1382-MIB",
1942
+ "oid" : "1.3.6.1.2.1.10.5.5.1.7",
1943
+ "status" : "current",
1944
+ "syntax" : {
1945
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1946
+ },
1947
+ "access" : "readonly",
1948
+ "description" :
1949
+ """The number of PDUs received for this
1950
+ circuit.""",
1951
+ "reference" :
1952
+ """10733 5.11 dataPacketsReceived""",
1953
+ }, # column
1954
+ "x25CircuitInRemotelyInitiatedResets" : {
1955
+ "nodetype" : "column",
1956
+ "moduleName" : "RFC1382-MIB",
1957
+ "oid" : "1.3.6.1.2.1.10.5.5.1.8",
1958
+ "status" : "current",
1959
+ "syntax" : {
1960
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1961
+ },
1962
+ "access" : "readonly",
1963
+ "description" :
1964
+ """The number of Resets received for this
1965
+ circuit with cause code of DTE initiated.""",
1966
+ "reference" :
1967
+ """10733 remotelyInitiatedResets""",
1968
+ }, # column
1969
+ "x25CircuitInProviderInitiatedResets" : {
1970
+ "nodetype" : "column",
1971
+ "moduleName" : "RFC1382-MIB",
1972
+ "oid" : "1.3.6.1.2.1.10.5.5.1.9",
1973
+ "status" : "current",
1974
+ "syntax" : {
1975
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1976
+ },
1977
+ "access" : "readonly",
1978
+ "description" :
1979
+ """The number of Resets received for this
1980
+ circuit with cause code other than DTE
1981
+ initiated.""",
1982
+ "reference" :
1983
+ """10733 ProviderInitiatedResets""",
1984
+ }, # column
1985
+ "x25CircuitInInterrupts" : {
1986
+ "nodetype" : "column",
1987
+ "moduleName" : "RFC1382-MIB",
1988
+ "oid" : "1.3.6.1.2.1.10.5.5.1.10",
1989
+ "status" : "current",
1990
+ "syntax" : {
1991
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1992
+ },
1993
+ "access" : "readonly",
1994
+ "description" :
1995
+ """The number of interrupt packets received
1996
+ for this circuit.""",
1997
+ "reference" :
1998
+ """10733 interruptPacketsReceived""",
1999
+ }, # column
2000
+ "x25CircuitOutOctets" : {
2001
+ "nodetype" : "column",
2002
+ "moduleName" : "RFC1382-MIB",
2003
+ "oid" : "1.3.6.1.2.1.10.5.5.1.11",
2004
+ "status" : "current",
2005
+ "syntax" : {
2006
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
2007
+ },
2008
+ "access" : "readonly",
2009
+ "description" :
2010
+ """The number of octets of user data sent for
2011
+ this circuit.""",
2012
+ "reference" :
2013
+ """10733 5.11 octetsSentCounter""",
2014
+ }, # column
2015
+ "x25CircuitOutPdus" : {
2016
+ "nodetype" : "column",
2017
+ "moduleName" : "RFC1382-MIB",
2018
+ "oid" : "1.3.6.1.2.1.10.5.5.1.12",
2019
+ "status" : "current",
2020
+ "syntax" : {
2021
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
2022
+ },
2023
+ "access" : "readonly",
2024
+ "description" :
2025
+ """The number of PDUs sent for this circuit.""",
2026
+ "reference" :
2027
+ """10733 5.11 dataPacketsSent""",
2028
+ }, # column
2029
+ "x25CircuitOutInterrupts" : {
2030
+ "nodetype" : "column",
2031
+ "moduleName" : "RFC1382-MIB",
2032
+ "oid" : "1.3.6.1.2.1.10.5.5.1.13",
2033
+ "status" : "current",
2034
+ "syntax" : {
2035
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
2036
+ },
2037
+ "access" : "readonly",
2038
+ "description" :
2039
+ """The number of interrupt packets sent on
2040
+ this circuit.""",
2041
+ "reference" :
2042
+ """10733 interruptPacketsSent""",
2043
+ }, # column
2044
+ "x25CircuitDataRetransmissionTimeouts" : {
2045
+ "nodetype" : "column",
2046
+ "moduleName" : "RFC1382-MIB",
2047
+ "oid" : "1.3.6.1.2.1.10.5.5.1.14",
2048
+ "status" : "current",
2049
+ "syntax" : {
2050
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
2051
+ },
2052
+ "access" : "readonly",
2053
+ "description" :
2054
+ """The number of times the T25 data
2055
+ retransmission timer expired for this
2056
+ circuit.""",
2057
+ "reference" :
2058
+ """10733 5.11 dataRetransmissionTimerExpiries""",
2059
+ }, # column
2060
+ "x25CircuitResetTimeouts" : {
2061
+ "nodetype" : "column",
2062
+ "moduleName" : "RFC1382-MIB",
2063
+ "oid" : "1.3.6.1.2.1.10.5.5.1.15",
2064
+ "status" : "current",
2065
+ "syntax" : {
2066
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
2067
+ },
2068
+ "access" : "readonly",
2069
+ "description" :
2070
+ """The number of times the T22 reset timer
2071
+ expired for this circuit.""",
2072
+ "reference" :
2073
+ """10733 5.11 resetTimeouts""",
2074
+ }, # column
2075
+ "x25CircuitInterruptTimeouts" : {
2076
+ "nodetype" : "column",
2077
+ "moduleName" : "RFC1382-MIB",
2078
+ "oid" : "1.3.6.1.2.1.10.5.5.1.16",
2079
+ "status" : "current",
2080
+ "syntax" : {
2081
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
2082
+ },
2083
+ "access" : "readonly",
2084
+ "description" :
2085
+ """The number of times the T26 Interrupt timer
2086
+ expired for this circuit.""",
2087
+ "reference" :
2088
+ """10733 interruptTimerExpiries""",
2089
+ }, # column
2090
+ "x25CircuitCallParamId" : {
2091
+ "nodetype" : "column",
2092
+ "moduleName" : "RFC1382-MIB",
2093
+ "oid" : "1.3.6.1.2.1.10.5.5.1.17",
2094
+ "status" : "current",
2095
+ "syntax" : {
2096
+ "type" : { "module" :"", "name" : "ObjectIdentifier"},
2097
+ },
2098
+ "access" : "readwrite",
2099
+ "default" : "0.0",
2100
+ "description" :
2101
+ """This identifies the instance of the
2102
+ x25CallParmIndex for the entry in the
2103
+ x25CallParmTable which contains the call
2104
+ parameters in use with this circuit. The
2105
+ entry referenced must contain the values
2106
+ that are currently in use by the circuit
2107
+ rather than proposed values. A value of
2108
+ NULL indicates the circuit is a PVC or is
2109
+ using all the default parameters.""",
2110
+ }, # column
2111
+ "x25CircuitCalledDteAddress" : {
2112
+ "nodetype" : "column",
2113
+ "moduleName" : "RFC1382-MIB",
2114
+ "oid" : "1.3.6.1.2.1.10.5.5.1.18",
2115
+ "status" : "current",
2116
+ "syntax" : {
2117
+ "type" : { "module" :"RFC1382-MIB", "name" : "X121Address"},
2118
+ },
2119
+ "access" : "readwrite",
2120
+ "default" : "",
2121
+ "description" :
2122
+ """For incoming calls, this is the called
2123
+ address from the call indication packet.
2124
+ For outgoing calls, this is the called
2125
+ address from the call confirmation packet.
2126
+ This will be zero length for PVCs.""",
2127
+ "reference" :
2128
+ """10733 calledDTEAddress""",
2129
+ }, # column
2130
+ "x25CircuitCallingDteAddress" : {
2131
+ "nodetype" : "column",
2132
+ "moduleName" : "RFC1382-MIB",
2133
+ "oid" : "1.3.6.1.2.1.10.5.5.1.19",
2134
+ "status" : "current",
2135
+ "syntax" : {
2136
+ "type" : { "module" :"RFC1382-MIB", "name" : "X121Address"},
2137
+ },
2138
+ "access" : "readwrite",
2139
+ "default" : "",
2140
+ "description" :
2141
+ """For incoming calls, this is the calling
2142
+ address from the call indication packet.
2143
+ For outgoing calls, this is the calling
2144
+ address from the call confirmation packet.
2145
+ This will be zero length for PVCs.""",
2146
+ "reference" :
2147
+ """10733 callingDTEAddress""",
2148
+ }, # column
2149
+ "x25CircuitOriginallyCalledAddress" : {
2150
+ "nodetype" : "column",
2151
+ "moduleName" : "RFC1382-MIB",
2152
+ "oid" : "1.3.6.1.2.1.10.5.5.1.20",
2153
+ "status" : "current",
2154
+ "syntax" : {
2155
+ "type" : { "module" :"RFC1382-MIB", "name" : "X121Address"},
2156
+ },
2157
+ "access" : "readwrite",
2158
+ "default" : "",
2159
+ "description" :
2160
+ """For incoming calls, this is the address in
2161
+ the call Redirection or Call Deflection
2162
+ Notification facility if the call was
2163
+ deflected or redirected, otherwise it will
2164
+ be called address from the call indication
2165
+ packet. For outgoing calls, this is the
2166
+ address from the call request packet. This
2167
+ will be zero length for PVCs.""",
2168
+ "reference" :
2169
+ """10733 originallyCalledAddress""",
2170
+ }, # column
2171
+ "x25CircuitDescr" : {
2172
+ "nodetype" : "column",
2173
+ "moduleName" : "RFC1382-MIB",
2174
+ "oid" : "1.3.6.1.2.1.10.5.5.1.21",
2175
+ "status" : "current",
2176
+ "syntax" : {
2177
+ "type" : {
2178
+ "basetype" : "OctetString",
2179
+ "parent module" : {
2180
+ "name" : "RFC1213-MIB",
2181
+ "type" : "DisplayString",
2182
+ },
2183
+ "ranges" : [
2184
+ {
2185
+ "min" : "0",
2186
+ "max" : "255"
2187
+ },
2188
+ ],
2189
+ "range" : {
2190
+ "min" : "0",
2191
+ "max" : "255"
2192
+ },
2193
+ },
2194
+ },
2195
+ "access" : "readwrite",
2196
+ "default" : "",
2197
+ "description" :
2198
+ """A descriptive string associated with this
2199
+ circuit. This provides a place for the
2200
+ agent to supply any descriptive information
2201
+ it knows about the use or owner of the
2202
+ circuit. The agent may return the process
2203
+ identifier and user name for the process
2204
+ using the circuit. Alternative the agent
2205
+ may return the name of the configuration
2206
+ entry that caused a bridge to establish the
2207
+ circuit. A zero length value indicates the
2208
+ agent doesn't have any additional
2209
+ information.""",
2210
+ }, # column
2211
+ "x25ClearedCircuitEntriesRequested" : {
2212
+ "nodetype" : "scalar",
2213
+ "moduleName" : "RFC1382-MIB",
2214
+ "oid" : "1.3.6.1.2.1.10.5.6",
2215
+ "status" : "current",
2216
+ "syntax" : {
2217
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
2218
+ },
2219
+ "access" : "readwrite",
2220
+ "description" :
2221
+ """The requested number of entries for the
2222
+ agent to keep in the x25ClearedCircuit
2223
+ table.""",
2224
+ }, # scalar
2225
+ "x25ClearedCircuitEntriesGranted" : {
2226
+ "nodetype" : "scalar",
2227
+ "moduleName" : "RFC1382-MIB",
2228
+ "oid" : "1.3.6.1.2.1.10.5.7",
2229
+ "status" : "current",
2230
+ "syntax" : {
2231
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
2232
+ },
2233
+ "access" : "readonly",
2234
+ "description" :
2235
+ """The actual number of entries the agent will
2236
+ keep in the x25ClearedCircuit Table.""",
2237
+ }, # scalar
2238
+ "x25ClearedCircuitTable" : {
2239
+ "nodetype" : "table",
2240
+ "moduleName" : "RFC1382-MIB",
2241
+ "oid" : "1.3.6.1.2.1.10.5.8",
2242
+ "status" : "current",
2243
+ "description" :
2244
+ """A table of entries about closed circuits.
2245
+ Entries must be made in this table whenever
2246
+ circuits are closed and the close request or
2247
+ close indication packet contains a clearing
2248
+ cause other than DTE Originated or a
2249
+ Diagnostic code field other than Higher
2250
+ Layer Initiated disconnection-normal. An
2251
+ agent may optionally make entries for normal
2252
+ closes (to record closing facilities or
2253
+ other information).
2254
+
2255
+ Agents will delete the oldest entry in the
2256
+ table when adding a new entry would exceed
2257
+ agent resources. Agents are required to
2258
+ keep the last entry put in the table and may
2259
+ keep more entries. The object
2260
+ x25OperClearEntriesGranted returns the
2261
+ maximum number of entries kept in the
2262
+ table.""",
2263
+ "reference" :
2264
+ """See ISO 8208 Section 12.2.3.1.1
2265
+ and 12.2.3.1.2""",
2266
+ }, # table
2267
+ "x25ClearedCircuitEntry" : {
2268
+ "nodetype" : "row",
2269
+ "moduleName" : "RFC1382-MIB",
2270
+ "oid" : "1.3.6.1.2.1.10.5.8.1",
2271
+ "status" : "current",
2272
+ "linkage" : [
2273
+ "x25ClearedCircuitIndex",
2274
+ ],
2275
+ "description" :
2276
+ """Information about a cleared circuit.""",
2277
+ }, # row
2278
+ "x25ClearedCircuitIndex" : {
2279
+ "nodetype" : "column",
2280
+ "moduleName" : "RFC1382-MIB",
2281
+ "oid" : "1.3.6.1.2.1.10.5.8.1.1",
2282
+ "status" : "current",
2283
+ "syntax" : {
2284
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
2285
+ },
2286
+ "access" : "readonly",
2287
+ "description" :
2288
+ """An index that uniquely distinguishes one
2289
+ entry in the clearedCircuitTable from
2290
+ another. This index will start at
2291
+ 2147483647 and will decrease by one for each
2292
+ new entry added to the table. Upon reaching
2293
+ one, the index will reset to 2147483647.
2294
+ Because the index starts at 2147483647 and
2295
+ decreases, a manager may do a getnext on
2296
+ entry zero and obtain the most recent entry.
2297
+ When the index has the value of 1, the next
2298
+ entry will delete all entries in the table
2299
+ and that entry will be numbered 2147483647.""",
2300
+ }, # column
2301
+ "x25ClearedCircuitPleIndex" : {
2302
+ "nodetype" : "column",
2303
+ "moduleName" : "RFC1382-MIB",
2304
+ "oid" : "1.3.6.1.2.1.10.5.8.1.2",
2305
+ "status" : "current",
2306
+ "syntax" : {
2307
+ "type" : { "module" :"RFC1381-MIB", "name" : "IfIndexType"},
2308
+ },
2309
+ "access" : "readonly",
2310
+ "description" :
2311
+ """The value of ifIndex for the PLE which
2312
+ cleared the circuit that created the entry.""",
2313
+ }, # column
2314
+ "x25ClearedCircuitTimeEstablished" : {
2315
+ "nodetype" : "column",
2316
+ "moduleName" : "RFC1382-MIB",
2317
+ "oid" : "1.3.6.1.2.1.10.5.8.1.3",
2318
+ "status" : "current",
2319
+ "syntax" : {
2320
+ "type" : { "module" :"RFC1155-SMI", "name" : "TimeTicks"},
2321
+ },
2322
+ "access" : "readonly",
2323
+ "description" :
2324
+ """The value of sysUpTime when the circuit was
2325
+ established. This will be the same value
2326
+ that was in the x25CircuitEstablishTime for
2327
+ the circuit.""",
2328
+ }, # column
2329
+ "x25ClearedCircuitTimeCleared" : {
2330
+ "nodetype" : "column",
2331
+ "moduleName" : "RFC1382-MIB",
2332
+ "oid" : "1.3.6.1.2.1.10.5.8.1.4",
2333
+ "status" : "current",
2334
+ "syntax" : {
2335
+ "type" : { "module" :"RFC1155-SMI", "name" : "TimeTicks"},
2336
+ },
2337
+ "access" : "readonly",
2338
+ "description" :
2339
+ """The value of sysUpTime when the circuit was
2340
+ cleared. For locally initiated clears, this
2341
+ will be the time when the clear confirmation
2342
+ was received. For remotely initiated
2343
+ clears, this will be the time when the clear
2344
+ indication was received.""",
2345
+ }, # column
2346
+ "x25ClearedCircuitChannel" : {
2347
+ "nodetype" : "column",
2348
+ "moduleName" : "RFC1382-MIB",
2349
+ "oid" : "1.3.6.1.2.1.10.5.8.1.5",
2350
+ "status" : "current",
2351
+ "syntax" : {
2352
+ "type" : {
2353
+ "basetype" : "Integer32",
2354
+ "ranges" : [
2355
+ {
2356
+ "min" : "0",
2357
+ "max" : "4095"
2358
+ },
2359
+ ],
2360
+ "range" : {
2361
+ "min" : "0",
2362
+ "max" : "4095"
2363
+ },
2364
+ },
2365
+ },
2366
+ "access" : "readonly",
2367
+ "description" :
2368
+ """The channel number for the circuit that was
2369
+ cleared.""",
2370
+ }, # column
2371
+ "x25ClearedCircuitClearingCause" : {
2372
+ "nodetype" : "column",
2373
+ "moduleName" : "RFC1382-MIB",
2374
+ "oid" : "1.3.6.1.2.1.10.5.8.1.6",
2375
+ "status" : "current",
2376
+ "syntax" : {
2377
+ "type" : {
2378
+ "basetype" : "Integer32",
2379
+ "ranges" : [
2380
+ {
2381
+ "min" : "0",
2382
+ "max" : "255"
2383
+ },
2384
+ ],
2385
+ "range" : {
2386
+ "min" : "0",
2387
+ "max" : "255"
2388
+ },
2389
+ },
2390
+ },
2391
+ "access" : "readonly",
2392
+ "description" :
2393
+ """The Clearing Cause from the clear request
2394
+ or clear indication packet that cleared the
2395
+ circuit.""",
2396
+ "reference" :
2397
+ """See ISO 8208 Section 12.2.3.1.1""",
2398
+ }, # column
2399
+ "x25ClearedCircuitDiagnosticCode" : {
2400
+ "nodetype" : "column",
2401
+ "moduleName" : "RFC1382-MIB",
2402
+ "oid" : "1.3.6.1.2.1.10.5.8.1.7",
2403
+ "status" : "current",
2404
+ "syntax" : {
2405
+ "type" : {
2406
+ "basetype" : "Integer32",
2407
+ "ranges" : [
2408
+ {
2409
+ "min" : "0",
2410
+ "max" : "255"
2411
+ },
2412
+ ],
2413
+ "range" : {
2414
+ "min" : "0",
2415
+ "max" : "255"
2416
+ },
2417
+ },
2418
+ },
2419
+ "access" : "readonly",
2420
+ "description" :
2421
+ """The Diagnostic Code from the clear request
2422
+ or clear indication packet that cleared the
2423
+ circuit.""",
2424
+ "reference" :
2425
+ """See ISO 8208 Section 12.2.3.1.2""",
2426
+ }, # column
2427
+ "x25ClearedCircuitInPdus" : {
2428
+ "nodetype" : "column",
2429
+ "moduleName" : "RFC1382-MIB",
2430
+ "oid" : "1.3.6.1.2.1.10.5.8.1.8",
2431
+ "status" : "current",
2432
+ "syntax" : {
2433
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
2434
+ },
2435
+ "access" : "readonly",
2436
+ "description" :
2437
+ """The number of PDUs received on the
2438
+ circuit.""",
2439
+ }, # column
2440
+ "x25ClearedCircuitOutPdus" : {
2441
+ "nodetype" : "column",
2442
+ "moduleName" : "RFC1382-MIB",
2443
+ "oid" : "1.3.6.1.2.1.10.5.8.1.9",
2444
+ "status" : "current",
2445
+ "syntax" : {
2446
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
2447
+ },
2448
+ "access" : "readonly",
2449
+ "description" :
2450
+ """The number of PDUs transmitted on the
2451
+ circuit.""",
2452
+ }, # column
2453
+ "x25ClearedCircuitCalledAddress" : {
2454
+ "nodetype" : "column",
2455
+ "moduleName" : "RFC1382-MIB",
2456
+ "oid" : "1.3.6.1.2.1.10.5.8.1.10",
2457
+ "status" : "current",
2458
+ "syntax" : {
2459
+ "type" : { "module" :"RFC1382-MIB", "name" : "X121Address"},
2460
+ },
2461
+ "access" : "readonly",
2462
+ "description" :
2463
+ """The called address from the cleared
2464
+ circuit.""",
2465
+ }, # column
2466
+ "x25ClearedCircuitCallingAddress" : {
2467
+ "nodetype" : "column",
2468
+ "moduleName" : "RFC1382-MIB",
2469
+ "oid" : "1.3.6.1.2.1.10.5.8.1.11",
2470
+ "status" : "current",
2471
+ "syntax" : {
2472
+ "type" : { "module" :"RFC1382-MIB", "name" : "X121Address"},
2473
+ },
2474
+ "access" : "readonly",
2475
+ "description" :
2476
+ """The calling address from the cleared
2477
+ circuit.""",
2478
+ }, # column
2479
+ "x25ClearedCircuitClearFacilities" : {
2480
+ "nodetype" : "column",
2481
+ "moduleName" : "RFC1382-MIB",
2482
+ "oid" : "1.3.6.1.2.1.10.5.8.1.12",
2483
+ "status" : "current",
2484
+ "syntax" : {
2485
+ "type" : {
2486
+ "basetype" : "OctetString",
2487
+ "ranges" : [
2488
+ {
2489
+ "min" : "0",
2490
+ "max" : "109"
2491
+ },
2492
+ ],
2493
+ "range" : {
2494
+ "min" : "0",
2495
+ "max" : "109"
2496
+ },
2497
+ },
2498
+ },
2499
+ "access" : "readonly",
2500
+ "description" :
2501
+ """The facilities field from the clear request
2502
+ or clear indication packet that cleared the
2503
+ circuit. A size of zero indicates no
2504
+ facilities were present.""",
2505
+ }, # column
2506
+ "x25CallParmTable" : {
2507
+ "nodetype" : "table",
2508
+ "moduleName" : "RFC1382-MIB",
2509
+ "oid" : "1.3.6.1.2.1.10.5.9",
2510
+ "status" : "current",
2511
+ "description" :
2512
+ """These objects contain the parameters that
2513
+ can be varied between X.25 calls. The
2514
+ entries in this table are independent of the
2515
+ PLE. There exists only one of these tables
2516
+ for the entire system. The indexes for the
2517
+ entries are independent of any PLE or any
2518
+ circuit. Other tables reference entries in
2519
+ this table. Entries in this table can be
2520
+ used for default PLE parameters, for
2521
+ parameters to use to place/answer a call,
2522
+ for the parameters currently in use for a
2523
+ circuit, or parameters that were used by a
2524
+ circuit.
2525
+
2526
+ The number of references to a given set of
2527
+ parameters can be found in the
2528
+ x25CallParmRefCount object sharing the same
2529
+ instance identifier with the parameters.
2530
+ The value of this reference count also
2531
+ affects the access of the objects in this
2532
+ table. An object in this table with the
2533
+ same instance identifier as the instance
2534
+ identifier of an x25CallParmRefCount must be
2535
+ consider associated with that reference
2536
+ count. An object with an associated
2537
+ reference count of zero can be written (if
2538
+ its ACCESS clause allows it). An object
2539
+ with an associated reference count greater
2540
+ than zero can not be written (regardless of
2541
+ the ACCESS clause). This ensures that a set
2542
+ of call parameters being referenced from
2543
+ another table can not be modified or changed
2544
+ in a ways inappropriate for continued use by
2545
+ that table.""",
2546
+ }, # table
2547
+ "x25CallParmEntry" : {
2548
+ "nodetype" : "row",
2549
+ "moduleName" : "RFC1382-MIB",
2550
+ "oid" : "1.3.6.1.2.1.10.5.9.1",
2551
+ "status" : "current",
2552
+ "linkage" : [
2553
+ "x25CallParmIndex",
2554
+ ],
2555
+ "description" :
2556
+ """Entries of x25CallParmTable.""",
2557
+ }, # row
2558
+ "x25CallParmIndex" : {
2559
+ "nodetype" : "column",
2560
+ "moduleName" : "RFC1382-MIB",
2561
+ "oid" : "1.3.6.1.2.1.10.5.9.1.1",
2562
+ "status" : "current",
2563
+ "syntax" : {
2564
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
2565
+ },
2566
+ "access" : "readonly",
2567
+ "description" :
2568
+ """A value that distinguishes this entry from
2569
+ another entry. Entries in this table are
2570
+ referenced from other objects which identify
2571
+ call parameters.
2572
+
2573
+ It is impossible to know which other objects
2574
+ in the MIB reference entries in the table by
2575
+ looking at this table. Because of this,
2576
+ changes to parameters must be accomplished
2577
+ by creating a new entry in this table and
2578
+ then changing the referencing table to
2579
+ identify the new entry.
2580
+
2581
+ Note that an agent will only use the values
2582
+ in this table when another table is changed
2583
+ to reference those values. The number of
2584
+ other tables that reference an index object
2585
+ in this table can be found in
2586
+ x25CallParmRefCount. The value of the
2587
+ reference count will affect the writability
2588
+ of the objects as explained above.
2589
+
2590
+ Entries in this table which have a reference
2591
+ count of zero maybe deleted at the convence
2592
+ of the agent. Care should be taken by the
2593
+ agent to give the NMS sufficient time to
2594
+ create a reference to newly created entries.
2595
+
2596
+ Should a Management Station not find a free
2597
+ index with which to create a new entry, it
2598
+ may feel free to delete entries with a
2599
+ reference count of zero. However in doing
2600
+ so the Management Station much realize it
2601
+ may impact other Management Stations.""",
2602
+ }, # column
2603
+ "x25CallParmStatus" : {
2604
+ "nodetype" : "column",
2605
+ "moduleName" : "RFC1382-MIB",
2606
+ "oid" : "1.3.6.1.2.1.10.5.9.1.2",
2607
+ "status" : "current",
2608
+ "syntax" : {
2609
+ "type" : { "module" :"RFC1271-MIB", "name" : "EntryStatus"},
2610
+ },
2611
+ "access" : "readwrite",
2612
+ "description" :
2613
+ """The status of this call parameter entry.
2614
+ See RFC 1271 for details of usage.""",
2615
+ }, # column
2616
+ "x25CallParmRefCount" : {
2617
+ "nodetype" : "column",
2618
+ "moduleName" : "RFC1382-MIB",
2619
+ "oid" : "1.3.6.1.2.1.10.5.9.1.3",
2620
+ "status" : "current",
2621
+ "syntax" : {
2622
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
2623
+ },
2624
+ "access" : "readonly",
2625
+ "description" :
2626
+ """The number of references know by a
2627
+ management station to exist to this set of
2628
+ call parameters. This is the number of
2629
+ other objects that have returned a value of,
2630
+ and will return a value of, the index for
2631
+ this set of call parameters. Examples of
2632
+ such objects are the x25AdmnDefCallParamId,
2633
+ x25OperDataLinkId, or x25AdmnDefCallParamId
2634
+ objects defined above.""",
2635
+ }, # column
2636
+ "x25CallParmInPacketSize" : {
2637
+ "nodetype" : "column",
2638
+ "moduleName" : "RFC1382-MIB",
2639
+ "oid" : "1.3.6.1.2.1.10.5.9.1.4",
2640
+ "status" : "current",
2641
+ "syntax" : {
2642
+ "type" : {
2643
+ "basetype" : "Integer32",
2644
+ "ranges" : [
2645
+ {
2646
+ "min" : "0",
2647
+ "max" : "4096"
2648
+ },
2649
+ ],
2650
+ "range" : {
2651
+ "min" : "0",
2652
+ "max" : "4096"
2653
+ },
2654
+ },
2655
+ },
2656
+ "access" : "readwrite",
2657
+ "default" : "128",
2658
+ "description" :
2659
+ """The maximum receive packet size in octets
2660
+ for a circuit. A size of zero for a circuit
2661
+ means use the PLE default size. A size of
2662
+ zero for the PLE means use a default size of
2663
+ 128.""",
2664
+ "reference" :
2665
+ """10733 proposedPacketSize;
2666
+ See ISO 8208 Section 15.2.2.1.1""",
2667
+ }, # column
2668
+ "x25CallParmOutPacketSize" : {
2669
+ "nodetype" : "column",
2670
+ "moduleName" : "RFC1382-MIB",
2671
+ "oid" : "1.3.6.1.2.1.10.5.9.1.5",
2672
+ "status" : "current",
2673
+ "syntax" : {
2674
+ "type" : {
2675
+ "basetype" : "Integer32",
2676
+ "ranges" : [
2677
+ {
2678
+ "min" : "0",
2679
+ "max" : "4096"
2680
+ },
2681
+ ],
2682
+ "range" : {
2683
+ "min" : "0",
2684
+ "max" : "4096"
2685
+ },
2686
+ },
2687
+ },
2688
+ "access" : "readwrite",
2689
+ "default" : "128",
2690
+ "description" :
2691
+ """The maximum transmit packet size in octets
2692
+ for a circuit. A size of zero for a circuit
2693
+ means use the PLE default size. A size of
2694
+ zero for the PLE default means use a default
2695
+ size of 128.""",
2696
+ "reference" :
2697
+ """10733 proposedPacketSize;
2698
+ See ISO 8208 Section 15.2.2.1.1""",
2699
+ }, # column
2700
+ "x25CallParmInWindowSize" : {
2701
+ "nodetype" : "column",
2702
+ "moduleName" : "RFC1382-MIB",
2703
+ "oid" : "1.3.6.1.2.1.10.5.9.1.6",
2704
+ "status" : "current",
2705
+ "syntax" : {
2706
+ "type" : {
2707
+ "basetype" : "Integer32",
2708
+ "ranges" : [
2709
+ {
2710
+ "min" : "0",
2711
+ "max" : "127"
2712
+ },
2713
+ ],
2714
+ "range" : {
2715
+ "min" : "0",
2716
+ "max" : "127"
2717
+ },
2718
+ },
2719
+ },
2720
+ "access" : "readwrite",
2721
+ "default" : "2",
2722
+ "description" :
2723
+ """The receive window size for a circuit. A
2724
+ size of zero for a circuit means use the PLE
2725
+ default size. A size of zero for the PLE
2726
+ default means use 2.""",
2727
+ "reference" :
2728
+ """10733 proposedWindowSize;
2729
+ See ISO 8208 Section 15.2.2.1.2""",
2730
+ }, # column
2731
+ "x25CallParmOutWindowSize" : {
2732
+ "nodetype" : "column",
2733
+ "moduleName" : "RFC1382-MIB",
2734
+ "oid" : "1.3.6.1.2.1.10.5.9.1.7",
2735
+ "status" : "current",
2736
+ "syntax" : {
2737
+ "type" : {
2738
+ "basetype" : "Integer32",
2739
+ "ranges" : [
2740
+ {
2741
+ "min" : "0",
2742
+ "max" : "127"
2743
+ },
2744
+ ],
2745
+ "range" : {
2746
+ "min" : "0",
2747
+ "max" : "127"
2748
+ },
2749
+ },
2750
+ },
2751
+ "access" : "readwrite",
2752
+ "default" : "2",
2753
+ "description" :
2754
+ """The transmit window size for a circuit. A
2755
+ size of zero for a circuit means use the PLE
2756
+ default size. A size of zero for the PLE
2757
+ default means use 2.""",
2758
+ "reference" :
2759
+ """10733 proposedWindowSize;
2760
+ See ISO 8208 Section 15.2.2.1.2""",
2761
+ }, # column
2762
+ "x25CallParmAcceptReverseCharging" : {
2763
+ "nodetype" : "column",
2764
+ "moduleName" : "RFC1382-MIB",
2765
+ "oid" : "1.3.6.1.2.1.10.5.9.1.8",
2766
+ "status" : "current",
2767
+ "syntax" : {
2768
+ "type" : {
2769
+ "basetype" : "Enumeration",
2770
+ "default" : {
2771
+ "nodetype" : "namednumber",
2772
+ "number" : "1"
2773
+ },
2774
+ "accept" : {
2775
+ "nodetype" : "namednumber",
2776
+ "number" : "2"
2777
+ },
2778
+ "refuse" : {
2779
+ "nodetype" : "namednumber",
2780
+ "number" : "3"
2781
+ },
2782
+ "neverAccept" : {
2783
+ "nodetype" : "namednumber",
2784
+ "number" : "4"
2785
+ },
2786
+ },
2787
+ },
2788
+ "access" : "readwrite",
2789
+ "default" : "refuse",
2790
+ "description" :
2791
+ """An enumeration defining if the PLE will
2792
+ accept or refuse charges. A value of
2793
+ default for a circuit means use the PLE
2794
+ default value. A value of neverAccept is
2795
+ only used for the PLE default and indicates
2796
+ the PLE will never accept reverse charging.
2797
+ A value of default for a PLE default means
2798
+ refuse.""",
2799
+ "reference" :
2800
+ """10733 acceptReverseCharging""",
2801
+ }, # column
2802
+ "x25CallParmProposeReverseCharging" : {
2803
+ "nodetype" : "column",
2804
+ "moduleName" : "RFC1382-MIB",
2805
+ "oid" : "1.3.6.1.2.1.10.5.9.1.9",
2806
+ "status" : "current",
2807
+ "syntax" : {
2808
+ "type" : {
2809
+ "basetype" : "Enumeration",
2810
+ "default" : {
2811
+ "nodetype" : "namednumber",
2812
+ "number" : "1"
2813
+ },
2814
+ "reverse" : {
2815
+ "nodetype" : "namednumber",
2816
+ "number" : "2"
2817
+ },
2818
+ "local" : {
2819
+ "nodetype" : "namednumber",
2820
+ "number" : "3"
2821
+ },
2822
+ },
2823
+ },
2824
+ "access" : "readwrite",
2825
+ "default" : "local",
2826
+ "description" :
2827
+ """An enumeration defining if the PLE should
2828
+ propose reverse or local charging. The
2829
+ value of default for a circuit means use the
2830
+ PLE default. The value of default for the
2831
+ PLE default means use local.""",
2832
+ "reference" :
2833
+ """10733 proposedPacketSize;
2834
+ See ISO 8208 Section 15.2.2.6""",
2835
+ }, # column
2836
+ "x25CallParmFastSelect" : {
2837
+ "nodetype" : "column",
2838
+ "moduleName" : "RFC1382-MIB",
2839
+ "oid" : "1.3.6.1.2.1.10.5.9.1.10",
2840
+ "status" : "current",
2841
+ "syntax" : {
2842
+ "type" : {
2843
+ "basetype" : "Enumeration",
2844
+ "default" : {
2845
+ "nodetype" : "namednumber",
2846
+ "number" : "1"
2847
+ },
2848
+ "notSpecified" : {
2849
+ "nodetype" : "namednumber",
2850
+ "number" : "2"
2851
+ },
2852
+ "fastSelect" : {
2853
+ "nodetype" : "namednumber",
2854
+ "number" : "3"
2855
+ },
2856
+ "restrictedFastResponse" : {
2857
+ "nodetype" : "namednumber",
2858
+ "number" : "4"
2859
+ },
2860
+ "noFastSelect" : {
2861
+ "nodetype" : "namednumber",
2862
+ "number" : "5"
2863
+ },
2864
+ "noRestrictedFastResponse" : {
2865
+ "nodetype" : "namednumber",
2866
+ "number" : "6"
2867
+ },
2868
+ },
2869
+ },
2870
+ "access" : "readwrite",
2871
+ "default" : "noFastSelect",
2872
+ "description" :
2873
+ """Expresses preference for use of fast select
2874
+ facility. The value of default for a
2875
+ circuit is the PLE default. A value of
2876
+ default for the PLE means noFastSelect. A
2877
+ value of noFastSelect or
2878
+ noRestrictedFastResponse indicates a circuit
2879
+ may not use fast select or restricted fast
2880
+ response.""",
2881
+ "reference" :
2882
+ """10733 fastSelect;
2883
+ Sec ISO 8208 Section 15.2.2.6""",
2884
+ }, # column
2885
+ "x25CallParmInThruPutClasSize" : {
2886
+ "nodetype" : "column",
2887
+ "moduleName" : "RFC1382-MIB",
2888
+ "oid" : "1.3.6.1.2.1.10.5.9.1.11",
2889
+ "status" : "current",
2890
+ "syntax" : {
2891
+ "type" : {
2892
+ "basetype" : "Enumeration",
2893
+ "tcReserved1" : {
2894
+ "nodetype" : "namednumber",
2895
+ "number" : "1"
2896
+ },
2897
+ "tcReserved2" : {
2898
+ "nodetype" : "namednumber",
2899
+ "number" : "2"
2900
+ },
2901
+ "tc75" : {
2902
+ "nodetype" : "namednumber",
2903
+ "number" : "3"
2904
+ },
2905
+ "tc150" : {
2906
+ "nodetype" : "namednumber",
2907
+ "number" : "4"
2908
+ },
2909
+ "tc300" : {
2910
+ "nodetype" : "namednumber",
2911
+ "number" : "5"
2912
+ },
2913
+ "tc600" : {
2914
+ "nodetype" : "namednumber",
2915
+ "number" : "6"
2916
+ },
2917
+ "tc1200" : {
2918
+ "nodetype" : "namednumber",
2919
+ "number" : "7"
2920
+ },
2921
+ "tc2400" : {
2922
+ "nodetype" : "namednumber",
2923
+ "number" : "8"
2924
+ },
2925
+ "tc4800" : {
2926
+ "nodetype" : "namednumber",
2927
+ "number" : "9"
2928
+ },
2929
+ "tc9600" : {
2930
+ "nodetype" : "namednumber",
2931
+ "number" : "10"
2932
+ },
2933
+ "tc19200" : {
2934
+ "nodetype" : "namednumber",
2935
+ "number" : "11"
2936
+ },
2937
+ "tc48000" : {
2938
+ "nodetype" : "namednumber",
2939
+ "number" : "12"
2940
+ },
2941
+ "tc64000" : {
2942
+ "nodetype" : "namednumber",
2943
+ "number" : "13"
2944
+ },
2945
+ "tcReserved14" : {
2946
+ "nodetype" : "namednumber",
2947
+ "number" : "14"
2948
+ },
2949
+ "tcReserved15" : {
2950
+ "nodetype" : "namednumber",
2951
+ "number" : "15"
2952
+ },
2953
+ "tcReserved0" : {
2954
+ "nodetype" : "namednumber",
2955
+ "number" : "16"
2956
+ },
2957
+ "tcNone" : {
2958
+ "nodetype" : "namednumber",
2959
+ "number" : "17"
2960
+ },
2961
+ "tcDefault" : {
2962
+ "nodetype" : "namednumber",
2963
+ "number" : "18"
2964
+ },
2965
+ },
2966
+ },
2967
+ "access" : "readwrite",
2968
+ "default" : "tcNone",
2969
+ "description" :
2970
+ """The incoming throughput class to negotiate.
2971
+ A value of tcDefault for a circuit means use
2972
+ the PLE default. A value of tcDefault for
2973
+ the PLE default means tcNone. A value of
2974
+ tcNone means do not negotiate throughtput
2975
+ class.""",
2976
+ "reference" :
2977
+ """See ISO 8208 Section 15.2.2.2, table 18""",
2978
+ }, # column
2979
+ "x25CallParmOutThruPutClasSize" : {
2980
+ "nodetype" : "column",
2981
+ "moduleName" : "RFC1382-MIB",
2982
+ "oid" : "1.3.6.1.2.1.10.5.9.1.12",
2983
+ "status" : "current",
2984
+ "syntax" : {
2985
+ "type" : {
2986
+ "basetype" : "Enumeration",
2987
+ "tcReserved1" : {
2988
+ "nodetype" : "namednumber",
2989
+ "number" : "1"
2990
+ },
2991
+ "tcReserved2" : {
2992
+ "nodetype" : "namednumber",
2993
+ "number" : "2"
2994
+ },
2995
+ "tc75" : {
2996
+ "nodetype" : "namednumber",
2997
+ "number" : "3"
2998
+ },
2999
+ "tc150" : {
3000
+ "nodetype" : "namednumber",
3001
+ "number" : "4"
3002
+ },
3003
+ "tc300" : {
3004
+ "nodetype" : "namednumber",
3005
+ "number" : "5"
3006
+ },
3007
+ "tc600" : {
3008
+ "nodetype" : "namednumber",
3009
+ "number" : "6"
3010
+ },
3011
+ "tc1200" : {
3012
+ "nodetype" : "namednumber",
3013
+ "number" : "7"
3014
+ },
3015
+ "tc2400" : {
3016
+ "nodetype" : "namednumber",
3017
+ "number" : "8"
3018
+ },
3019
+ "tc4800" : {
3020
+ "nodetype" : "namednumber",
3021
+ "number" : "9"
3022
+ },
3023
+ "tc9600" : {
3024
+ "nodetype" : "namednumber",
3025
+ "number" : "10"
3026
+ },
3027
+ "tc19200" : {
3028
+ "nodetype" : "namednumber",
3029
+ "number" : "11"
3030
+ },
3031
+ "tc48000" : {
3032
+ "nodetype" : "namednumber",
3033
+ "number" : "12"
3034
+ },
3035
+ "tc64000" : {
3036
+ "nodetype" : "namednumber",
3037
+ "number" : "13"
3038
+ },
3039
+ "tcReserved14" : {
3040
+ "nodetype" : "namednumber",
3041
+ "number" : "14"
3042
+ },
3043
+ "tcReserved15" : {
3044
+ "nodetype" : "namednumber",
3045
+ "number" : "15"
3046
+ },
3047
+ "tcReserved0" : {
3048
+ "nodetype" : "namednumber",
3049
+ "number" : "16"
3050
+ },
3051
+ "tcNone" : {
3052
+ "nodetype" : "namednumber",
3053
+ "number" : "17"
3054
+ },
3055
+ "tcDefault" : {
3056
+ "nodetype" : "namednumber",
3057
+ "number" : "18"
3058
+ },
3059
+ },
3060
+ },
3061
+ "access" : "readwrite",
3062
+ "default" : "tcNone",
3063
+ "description" :
3064
+ """The outgoing throughput class to negotiate.
3065
+ A value of tcDefault for a circuit means use
3066
+ the PLE default. A value of tcDefault for
3067
+ the PLE default means use tcNone. A value
3068
+ of tcNone means do not negotiate throughtput
3069
+ class.""",
3070
+ "reference" :
3071
+ """See ISO 8208 Section 15.2.2.2, table 18""",
3072
+ }, # column
3073
+ "x25CallParmCug" : {
3074
+ "nodetype" : "column",
3075
+ "moduleName" : "RFC1382-MIB",
3076
+ "oid" : "1.3.6.1.2.1.10.5.9.1.13",
3077
+ "status" : "current",
3078
+ "syntax" : {
3079
+ "type" : {
3080
+ "basetype" : "OctetString",
3081
+ "parent module" : {
3082
+ "name" : "RFC1213-MIB",
3083
+ "type" : "DisplayString",
3084
+ },
3085
+ "ranges" : [
3086
+ {
3087
+ "min" : "0",
3088
+ "max" : "4"
3089
+ },
3090
+ ],
3091
+ "range" : {
3092
+ "min" : "0",
3093
+ "max" : "4"
3094
+ },
3095
+ },
3096
+ },
3097
+ "access" : "readwrite",
3098
+ "default" : "",
3099
+ "description" :
3100
+ """The Closed User Group to specify. This
3101
+ consists of two or four octets containing
3102
+ the characters 0 through 9. A zero length
3103
+ string indicates no facility requested. A
3104
+ string length of three containing the
3105
+ characters DEF for a circuit means use the
3106
+ PLE default, (the PLE default parameter may
3107
+ not reference an entry of DEF.)""",
3108
+ "reference" :
3109
+ """See ISO 8208 Section 15.2.2.3""",
3110
+ }, # column
3111
+ "x25CallParmCugoa" : {
3112
+ "nodetype" : "column",
3113
+ "moduleName" : "RFC1382-MIB",
3114
+ "oid" : "1.3.6.1.2.1.10.5.9.1.14",
3115
+ "status" : "current",
3116
+ "syntax" : {
3117
+ "type" : {
3118
+ "basetype" : "OctetString",
3119
+ "parent module" : {
3120
+ "name" : "RFC1213-MIB",
3121
+ "type" : "DisplayString",
3122
+ },
3123
+ "ranges" : [
3124
+ {
3125
+ "min" : "0",
3126
+ "max" : "4"
3127
+ },
3128
+ ],
3129
+ "range" : {
3130
+ "min" : "0",
3131
+ "max" : "4"
3132
+ },
3133
+ },
3134
+ },
3135
+ "access" : "readwrite",
3136
+ "default" : "",
3137
+ "description" :
3138
+ """The Closed User Group with Outgoing Access
3139
+ to specify. This consists of two or four
3140
+ octets containing the characters 0 through
3141
+ 9. A string length of three containing the
3142
+ characters DEF for a circuit means use the
3143
+ PLE default (the PLE default parameters may
3144
+ not reference an entry of DEF). A zero
3145
+ length string indicates no facility
3146
+ requested.""",
3147
+ "reference" :
3148
+ """See ISO 8208 Section 15.2.2.4""",
3149
+ }, # column
3150
+ "x25CallParmBcug" : {
3151
+ "nodetype" : "column",
3152
+ "moduleName" : "RFC1382-MIB",
3153
+ "oid" : "1.3.6.1.2.1.10.5.9.1.15",
3154
+ "status" : "current",
3155
+ "syntax" : {
3156
+ "type" : {
3157
+ "basetype" : "OctetString",
3158
+ "parent module" : {
3159
+ "name" : "RFC1213-MIB",
3160
+ "type" : "DisplayString",
3161
+ },
3162
+ "ranges" : [
3163
+ {
3164
+ "min" : "0",
3165
+ "max" : "3"
3166
+ },
3167
+ ],
3168
+ "range" : {
3169
+ "min" : "0",
3170
+ "max" : "3"
3171
+ },
3172
+ },
3173
+ },
3174
+ "access" : "readwrite",
3175
+ "default" : "",
3176
+ "description" :
3177
+ """The Bilateral Closed User Group to specify.
3178
+ This consists of two octets containing the
3179
+ characters 0 through 9. A string length of
3180
+ three containing the characters DEF for a
3181
+ circuit means use the PLE default (the PLE
3182
+ default parameter may not reference an entry
3183
+ of DEF). A zero length string indicates no
3184
+ facility requested.""",
3185
+ "reference" :
3186
+ """See ISO 8208 Section 15.2.2.5""",
3187
+ }, # column
3188
+ "x25CallParmNui" : {
3189
+ "nodetype" : "column",
3190
+ "moduleName" : "RFC1382-MIB",
3191
+ "oid" : "1.3.6.1.2.1.10.5.9.1.16",
3192
+ "status" : "current",
3193
+ "syntax" : {
3194
+ "type" : {
3195
+ "basetype" : "OctetString",
3196
+ "ranges" : [
3197
+ {
3198
+ "min" : "0",
3199
+ "max" : "108"
3200
+ },
3201
+ ],
3202
+ "range" : {
3203
+ "min" : "0",
3204
+ "max" : "108"
3205
+ },
3206
+ },
3207
+ },
3208
+ "access" : "readwrite",
3209
+ "default" : "",
3210
+ "description" :
3211
+ """The Network User Identifier facility. This
3212
+ is binary value to be included immediately
3213
+ after the length field. The PLE will supply
3214
+ the length octet. A zero length string
3215
+ indicates no facility requested. This value
3216
+ is ignored for the PLE default parameters
3217
+ entry.""",
3218
+ "reference" :
3219
+ """See ISO 8208 Section 15.2.2.7""",
3220
+ }, # column
3221
+ "x25CallParmChargingInfo" : {
3222
+ "nodetype" : "column",
3223
+ "moduleName" : "RFC1382-MIB",
3224
+ "oid" : "1.3.6.1.2.1.10.5.9.1.17",
3225
+ "status" : "current",
3226
+ "syntax" : {
3227
+ "type" : {
3228
+ "basetype" : "Enumeration",
3229
+ "default" : {
3230
+ "nodetype" : "namednumber",
3231
+ "number" : "1"
3232
+ },
3233
+ "noFacility" : {
3234
+ "nodetype" : "namednumber",
3235
+ "number" : "2"
3236
+ },
3237
+ "noChargingInfo" : {
3238
+ "nodetype" : "namednumber",
3239
+ "number" : "3"
3240
+ },
3241
+ "chargingInfo" : {
3242
+ "nodetype" : "namednumber",
3243
+ "number" : "4"
3244
+ },
3245
+ },
3246
+ },
3247
+ "access" : "readwrite",
3248
+ "default" : "noFacility",
3249
+ "description" :
3250
+ """The charging Information facility. A value
3251
+ of default for a circuit means use the PLE
3252
+ default. The value of default for the
3253
+ default PLE parameters means use noFacility.
3254
+ The value of noFacility means do not include
3255
+ a facility.""",
3256
+ "reference" :
3257
+ """See ISO 8208 Section 15.2.2.8""",
3258
+ }, # column
3259
+ "x25CallParmRpoa" : {
3260
+ "nodetype" : "column",
3261
+ "moduleName" : "RFC1382-MIB",
3262
+ "oid" : "1.3.6.1.2.1.10.5.9.1.18",
3263
+ "status" : "current",
3264
+ "syntax" : {
3265
+ "type" : {
3266
+ "basetype" : "OctetString",
3267
+ "parent module" : {
3268
+ "name" : "RFC1213-MIB",
3269
+ "type" : "DisplayString",
3270
+ },
3271
+ "ranges" : [
3272
+ {
3273
+ "min" : "0",
3274
+ "max" : "108"
3275
+ },
3276
+ ],
3277
+ "range" : {
3278
+ "min" : "0",
3279
+ "max" : "108"
3280
+ },
3281
+ },
3282
+ },
3283
+ "access" : "readwrite",
3284
+ "default" : "",
3285
+ "description" :
3286
+ """The RPOA facility. The octet string
3287
+ contains n * 4 sequences of the characters
3288
+ 0-9 to specify a facility with n entries.
3289
+ The octet string containing the 3 characters
3290
+ DEF for a circuit specifies use of the PLE
3291
+ default (the entry for the PLE default may
3292
+ not contain DEF). A zero length string
3293
+ indicates no facility requested.""",
3294
+ "reference" :
3295
+ """See ISO 8208, section 15.2.2.9""",
3296
+ }, # column
3297
+ "x25CallParmTrnstDly" : {
3298
+ "nodetype" : "column",
3299
+ "moduleName" : "RFC1382-MIB",
3300
+ "oid" : "1.3.6.1.2.1.10.5.9.1.19",
3301
+ "status" : "current",
3302
+ "syntax" : {
3303
+ "type" : {
3304
+ "basetype" : "Integer32",
3305
+ "ranges" : [
3306
+ {
3307
+ "min" : "0",
3308
+ "max" : "65537"
3309
+ },
3310
+ ],
3311
+ "range" : {
3312
+ "min" : "0",
3313
+ "max" : "65537"
3314
+ },
3315
+ },
3316
+ },
3317
+ "access" : "readwrite",
3318
+ "default" : "65536",
3319
+ "description" :
3320
+ """The Transit Delay Selection and Indication
3321
+ value. A value of 65536 indicates no
3322
+ facility requested. A value of 65537 for a
3323
+ circuit means use the PLE default (the PLE
3324
+ default parameters entry may not use the
3325
+ value 65537). The value 65535 may only be
3326
+ used to indicate the value in use by a
3327
+ circuit.""",
3328
+ "reference" :
3329
+ """See ISO 8208, Section 15.2.2.13""",
3330
+ }, # column
3331
+ "x25CallParmCallingExt" : {
3332
+ "nodetype" : "column",
3333
+ "moduleName" : "RFC1382-MIB",
3334
+ "oid" : "1.3.6.1.2.1.10.5.9.1.20",
3335
+ "status" : "current",
3336
+ "syntax" : {
3337
+ "type" : {
3338
+ "basetype" : "OctetString",
3339
+ "parent module" : {
3340
+ "name" : "RFC1213-MIB",
3341
+ "type" : "DisplayString",
3342
+ },
3343
+ "ranges" : [
3344
+ {
3345
+ "min" : "0",
3346
+ "max" : "40"
3347
+ },
3348
+ ],
3349
+ "range" : {
3350
+ "min" : "0",
3351
+ "max" : "40"
3352
+ },
3353
+ },
3354
+ },
3355
+ "access" : "readwrite",
3356
+ "default" : "",
3357
+ "description" :
3358
+ """The Calling Extension facility. This
3359
+ contains one of the following:
3360
+
3361
+ A sequence of hex digits with the value to
3362
+ be put in the facility. These digits will be
3363
+ converted to binary by the agent and put in
3364
+ the facility. These octets do not include
3365
+ the length octet.
3366
+
3367
+ A value containing the three character DEF
3368
+ for a circuit means use the PLE default,
3369
+ (the entry for the PLE default parameters
3370
+ may not use the value DEF).
3371
+
3372
+ A zero length string indicates no facility
3373
+ requested.""",
3374
+ "reference" :
3375
+ """See ISO 8208 Section 15.3.2.1""",
3376
+ }, # column
3377
+ "x25CallParmCalledExt" : {
3378
+ "nodetype" : "column",
3379
+ "moduleName" : "RFC1382-MIB",
3380
+ "oid" : "1.3.6.1.2.1.10.5.9.1.21",
3381
+ "status" : "current",
3382
+ "syntax" : {
3383
+ "type" : {
3384
+ "basetype" : "OctetString",
3385
+ "parent module" : {
3386
+ "name" : "RFC1213-MIB",
3387
+ "type" : "DisplayString",
3388
+ },
3389
+ "ranges" : [
3390
+ {
3391
+ "min" : "0",
3392
+ "max" : "40"
3393
+ },
3394
+ ],
3395
+ "range" : {
3396
+ "min" : "0",
3397
+ "max" : "40"
3398
+ },
3399
+ },
3400
+ },
3401
+ "access" : "readwrite",
3402
+ "default" : "",
3403
+ "description" :
3404
+ """The Called Extension facility. This
3405
+ contains one of the following:
3406
+
3407
+ A sequence of hex digits with the value to
3408
+ be put in the facility. These digits will be
3409
+ converted to binary by the agent and put in
3410
+ the facility. These octets do not include
3411
+ the length octet.
3412
+
3413
+ A value containing the three character DEF
3414
+ for a circuit means use the PLE default,
3415
+ (the entry for the PLE default parameters
3416
+ may not use the value DEF).
3417
+
3418
+ A zero length string indicates no facility
3419
+ requested.""",
3420
+ "reference" :
3421
+ """See ISO 8208 Section 15.3.2.2""",
3422
+ }, # column
3423
+ "x25CallParmInMinThuPutCls" : {
3424
+ "nodetype" : "column",
3425
+ "moduleName" : "RFC1382-MIB",
3426
+ "oid" : "1.3.6.1.2.1.10.5.9.1.22",
3427
+ "status" : "current",
3428
+ "syntax" : {
3429
+ "type" : {
3430
+ "basetype" : "Integer32",
3431
+ "ranges" : [
3432
+ {
3433
+ "min" : "0",
3434
+ "max" : "17"
3435
+ },
3436
+ ],
3437
+ "range" : {
3438
+ "min" : "0",
3439
+ "max" : "17"
3440
+ },
3441
+ },
3442
+ },
3443
+ "access" : "readwrite",
3444
+ "default" : "17",
3445
+ "description" :
3446
+ """The minimum input throughput Class. A
3447
+ value of 16 for a circuit means use the PLE
3448
+ default (the PLE parameters entry may not
3449
+ use this value). A value of 17 indicates no
3450
+ facility requested.""",
3451
+ "reference" :
3452
+ """See ISO 8208 Section 15.3.2.3""",
3453
+ }, # column
3454
+ "x25CallParmOutMinThuPutCls" : {
3455
+ "nodetype" : "column",
3456
+ "moduleName" : "RFC1382-MIB",
3457
+ "oid" : "1.3.6.1.2.1.10.5.9.1.23",
3458
+ "status" : "current",
3459
+ "syntax" : {
3460
+ "type" : {
3461
+ "basetype" : "Integer32",
3462
+ "ranges" : [
3463
+ {
3464
+ "min" : "0",
3465
+ "max" : "17"
3466
+ },
3467
+ ],
3468
+ "range" : {
3469
+ "min" : "0",
3470
+ "max" : "17"
3471
+ },
3472
+ },
3473
+ },
3474
+ "access" : "readwrite",
3475
+ "default" : "17",
3476
+ "description" :
3477
+ """The minimum output throughput Class. A
3478
+ value of 16 for a circuit means use the PLE
3479
+ default (the PLE parameters entry may not
3480
+ use this value). A value of 17 indicates no
3481
+ facility requested.""",
3482
+ "reference" :
3483
+ """See ISO 8208 Section 15.3.2.3""",
3484
+ }, # column
3485
+ "x25CallParmEndTrnsDly" : {
3486
+ "nodetype" : "column",
3487
+ "moduleName" : "RFC1382-MIB",
3488
+ "oid" : "1.3.6.1.2.1.10.5.9.1.24",
3489
+ "status" : "current",
3490
+ "syntax" : {
3491
+ "type" : {
3492
+ "basetype" : "OctetString",
3493
+ "ranges" : [
3494
+ {
3495
+ "min" : "0",
3496
+ "max" : "6"
3497
+ },
3498
+ ],
3499
+ "range" : {
3500
+ "min" : "0",
3501
+ "max" : "6"
3502
+ },
3503
+ },
3504
+ },
3505
+ "access" : "readwrite",
3506
+ "default" : "",
3507
+ "description" :
3508
+ """The End-to-End Transit Delay to negotiate.
3509
+ An octet string of length 2, 4, or 6
3510
+ contains the facility encoded as specified
3511
+ in ISO/IEC 8208 section 15.3.2.4. An octet
3512
+ string of length 3 containing the three
3513
+ character DEF for a circuit means use the
3514
+ PLE default (the entry for the PLE default
3515
+ can not contain the characters DEF). A zero
3516
+ length string indicates no facility
3517
+ requested.""",
3518
+ "reference" :
3519
+ """See ISO 8208 Section 15.3.2.4""",
3520
+ }, # column
3521
+ "x25CallParmPriority" : {
3522
+ "nodetype" : "column",
3523
+ "moduleName" : "RFC1382-MIB",
3524
+ "oid" : "1.3.6.1.2.1.10.5.9.1.25",
3525
+ "status" : "current",
3526
+ "syntax" : {
3527
+ "type" : {
3528
+ "basetype" : "OctetString",
3529
+ "ranges" : [
3530
+ {
3531
+ "min" : "0",
3532
+ "max" : "6"
3533
+ },
3534
+ ],
3535
+ "range" : {
3536
+ "min" : "0",
3537
+ "max" : "6"
3538
+ },
3539
+ },
3540
+ },
3541
+ "access" : "readwrite",
3542
+ "default" : "",
3543
+ "description" :
3544
+ """The priority facility to negotiate. The
3545
+ octet string encoded as specified in ISO/IEC
3546
+ 8208 section 15.3.2.5. A zero length string
3547
+ indicates no facility requested. The entry
3548
+ for the PLE default parameters must be zero
3549
+ length.""",
3550
+ "reference" :
3551
+ """See ISO 8208 Section 15.3.2.5""",
3552
+ }, # column
3553
+ "x25CallParmProtection" : {
3554
+ "nodetype" : "column",
3555
+ "moduleName" : "RFC1382-MIB",
3556
+ "oid" : "1.3.6.1.2.1.10.5.9.1.26",
3557
+ "status" : "current",
3558
+ "syntax" : {
3559
+ "type" : {
3560
+ "basetype" : "OctetString",
3561
+ "parent module" : {
3562
+ "name" : "RFC1213-MIB",
3563
+ "type" : "DisplayString",
3564
+ },
3565
+ "ranges" : [
3566
+ {
3567
+ "min" : "0",
3568
+ "max" : "108"
3569
+ },
3570
+ ],
3571
+ "range" : {
3572
+ "min" : "0",
3573
+ "max" : "108"
3574
+ },
3575
+ },
3576
+ },
3577
+ "access" : "readwrite",
3578
+ "default" : "",
3579
+ "description" :
3580
+ """A string contains the following:
3581
+ A hex string containing the value for the
3582
+ protection facility. This will be converted
3583
+ from hex to the octets actually in the
3584
+ packet by the agent. The agent will supply
3585
+ the length field and the length octet is not
3586
+ contained in this string.
3587
+
3588
+ An string containing the 3 characters DEF
3589
+ for a circuit means use the PLE default (the
3590
+ entry for the PLE default parameters may not
3591
+ use the value DEF).
3592
+
3593
+ A zero length string mean no facility
3594
+ requested.""",
3595
+ "reference" :
3596
+ """See ISO 8208 Section 15.3.2.5""",
3597
+ }, # column
3598
+ "x25CallParmExptData" : {
3599
+ "nodetype" : "column",
3600
+ "moduleName" : "RFC1382-MIB",
3601
+ "oid" : "1.3.6.1.2.1.10.5.9.1.27",
3602
+ "status" : "current",
3603
+ "syntax" : {
3604
+ "type" : {
3605
+ "basetype" : "Enumeration",
3606
+ "default" : {
3607
+ "nodetype" : "namednumber",
3608
+ "number" : "1"
3609
+ },
3610
+ "noExpeditedData" : {
3611
+ "nodetype" : "namednumber",
3612
+ "number" : "2"
3613
+ },
3614
+ "expeditedData" : {
3615
+ "nodetype" : "namednumber",
3616
+ "number" : "3"
3617
+ },
3618
+ },
3619
+ },
3620
+ "access" : "readwrite",
3621
+ "default" : "noExpeditedData",
3622
+ "description" :
3623
+ """The Expedited Data facility to negotiate.
3624
+ A value of default for a circuit means use
3625
+ the PLE default value. The entry for the
3626
+ PLE default parameters may not have the
3627
+ value default.""",
3628
+ "reference" :
3629
+ """See ISO 8208 Section 15.3.2.7""",
3630
+ }, # column
3631
+ "x25CallParmUserData" : {
3632
+ "nodetype" : "column",
3633
+ "moduleName" : "RFC1382-MIB",
3634
+ "oid" : "1.3.6.1.2.1.10.5.9.1.28",
3635
+ "status" : "current",
3636
+ "syntax" : {
3637
+ "type" : {
3638
+ "basetype" : "OctetString",
3639
+ "ranges" : [
3640
+ {
3641
+ "min" : "0",
3642
+ "max" : "128"
3643
+ },
3644
+ ],
3645
+ "range" : {
3646
+ "min" : "0",
3647
+ "max" : "128"
3648
+ },
3649
+ },
3650
+ },
3651
+ "access" : "readwrite",
3652
+ "default" : "",
3653
+ "description" :
3654
+ """The call user data as placed in the packet.
3655
+ A zero length string indicates no call user
3656
+ data. If both the circuit call parameters
3657
+ and the PLE default have call user data
3658
+ defined, the data from the circuit call
3659
+ parameters will be used. If only the PLE
3660
+ has data defined, the PLE entry will be
3661
+ used. If neither the circuit call
3662
+ parameters or the PLE default entry has a
3663
+ value, no call user data will be sent.""",
3664
+ "reference" :
3665
+ """See ISO 8208 Section 12.2.1.1.6, 12.2.1.2""",
3666
+ }, # column
3667
+ "x25CallParmCallingNetworkFacilities" : {
3668
+ "nodetype" : "column",
3669
+ "moduleName" : "RFC1382-MIB",
3670
+ "oid" : "1.3.6.1.2.1.10.5.9.1.29",
3671
+ "status" : "current",
3672
+ "syntax" : {
3673
+ "type" : {
3674
+ "basetype" : "OctetString",
3675
+ "ranges" : [
3676
+ {
3677
+ "min" : "0",
3678
+ "max" : "108"
3679
+ },
3680
+ ],
3681
+ "range" : {
3682
+ "min" : "0",
3683
+ "max" : "108"
3684
+ },
3685
+ },
3686
+ },
3687
+ "access" : "readwrite",
3688
+ "default" : "",
3689
+ "description" :
3690
+ """The calling network facilities. The
3691
+ facilities are encoded here exactly as
3692
+ encoded in the call packet. These
3693
+ facilities do not include the marker
3694
+ facility code.
3695
+
3696
+ A zero length string in the entry for the
3697
+ parameter to use when establishing a circuit
3698
+ means use the PLE default. A zero length
3699
+ string in the entry for PLE default
3700
+ parameters indicates no default facilities.""",
3701
+ "reference" :
3702
+ """See ISO 8206 Section 15.1, category b""",
3703
+ }, # column
3704
+ "x25CallParmCalledNetworkFacilities" : {
3705
+ "nodetype" : "column",
3706
+ "moduleName" : "RFC1382-MIB",
3707
+ "oid" : "1.3.6.1.2.1.10.5.9.1.30",
3708
+ "status" : "current",
3709
+ "syntax" : {
3710
+ "type" : {
3711
+ "basetype" : "OctetString",
3712
+ "ranges" : [
3713
+ {
3714
+ "min" : "0",
3715
+ "max" : "108"
3716
+ },
3717
+ ],
3718
+ "range" : {
3719
+ "min" : "0",
3720
+ "max" : "108"
3721
+ },
3722
+ },
3723
+ },
3724
+ "access" : "readwrite",
3725
+ "default" : "",
3726
+ "description" :
3727
+ """The called network facilities. The
3728
+ facilities are encoded here exactly as
3729
+ encoded in the call packet. These
3730
+ facilities do not include the marker
3731
+ facility code.
3732
+
3733
+ A zero length string in the entry for the
3734
+ parameter to use when establishing a circuit
3735
+ means use the PLE default. A zero length
3736
+ string in the entry for PLE default
3737
+ parameters indicates no default facilities.""",
3738
+ "reference" :
3739
+ """See ISO 8206 Section 15.1, category c""",
3740
+ }, # column
3741
+ "x25ProtocolVersion" : {
3742
+ "nodetype" : "node",
3743
+ "moduleName" : "RFC1382-MIB",
3744
+ "oid" : "1.3.6.1.2.1.10.5.10",
3745
+ }, # node
3746
+ "x25protocolCcittV1976" : {
3747
+ "nodetype" : "node",
3748
+ "moduleName" : "RFC1382-MIB",
3749
+ "oid" : "1.3.6.1.2.1.10.5.10.1",
3750
+ }, # node
3751
+ "x25protocolCcittV1980" : {
3752
+ "nodetype" : "node",
3753
+ "moduleName" : "RFC1382-MIB",
3754
+ "oid" : "1.3.6.1.2.1.10.5.10.2",
3755
+ }, # node
3756
+ "x25protocolCcittV1984" : {
3757
+ "nodetype" : "node",
3758
+ "moduleName" : "RFC1382-MIB",
3759
+ "oid" : "1.3.6.1.2.1.10.5.10.3",
3760
+ }, # node
3761
+ "x25protocolCcittV1988" : {
3762
+ "nodetype" : "node",
3763
+ "moduleName" : "RFC1382-MIB",
3764
+ "oid" : "1.3.6.1.2.1.10.5.10.4",
3765
+ }, # node
3766
+ "x25protocolIso8208V1987" : {
3767
+ "nodetype" : "node",
3768
+ "moduleName" : "RFC1382-MIB",
3769
+ "oid" : "1.3.6.1.2.1.10.5.10.5",
3770
+ }, # node
3771
+ "x25protocolIso8208V1989" : {
3772
+ "nodetype" : "node",
3773
+ "moduleName" : "RFC1382-MIB",
3774
+ "oid" : "1.3.6.1.2.1.10.5.10.6",
3775
+ }, # node
3776
+ }, # nodes
3777
+
3778
+ "notifications" : {
3779
+ "x25Restart" : {
3780
+ "nodetype" : "notification",
3781
+ "moduleName" : "RFC1382-MIB",
3782
+ "oid" : "1.3.6.1.2.1.10.5.0.1",
3783
+ "status" : "current",
3784
+ "objects" : {
3785
+ "x25OperIndex" : {
3786
+ "nodetype" : "object",
3787
+ "module" : "RFC1382-MIB"
3788
+ },
3789
+ },
3790
+ "description" :
3791
+ """This trap means the X.25 PLE sent or
3792
+ received a restart packet. The restart that
3793
+ brings up the link should not send a
3794
+ x25Restart trap so the interface should send
3795
+ a linkUp trap. Sending this trap means the
3796
+ agent does not send a linkDown and linkUp
3797
+ trap.""",
3798
+ }, # notification
3799
+ "x25Reset" : {
3800
+ "nodetype" : "notification",
3801
+ "moduleName" : "RFC1382-MIB",
3802
+ "oid" : "1.3.6.1.2.1.10.5.0.2",
3803
+ "status" : "current",
3804
+ "objects" : {
3805
+ "x25CircuitIndex" : {
3806
+ "nodetype" : "object",
3807
+ "module" : "RFC1382-MIB"
3808
+ },
3809
+ "x25CircuitChannel" : {
3810
+ "nodetype" : "object",
3811
+ "module" : "RFC1382-MIB"
3812
+ },
3813
+ },
3814
+ "description" :
3815
+ """If the PLE sends or receives a reset, the
3816
+ agent should send an x25Reset trap.""",
3817
+ }, # notification
3818
+ }, # notifications
3819
+
3820
+ }