logstash-input-snmp 0.1.0.beta4 → 0.1.0.beta5

Sign up to get free protection for your applications and to get access to all the features.
Files changed (309) hide show
  1. checksums.yaml +4 -4
  2. data/CHANGELOG.md +5 -0
  3. data/lib/logstash/inputs/snmp.rb +75 -12
  4. data/lib/logstash/inputs/snmp/base_client.rb +162 -0
  5. data/lib/logstash/inputs/snmp/client.rb +11 -109
  6. data/lib/logstash/inputs/snmp/clientv3.rb +139 -0
  7. data/lib/logstash/inputs/snmp/mib.rb +22 -20
  8. data/lib/mibs/ietf/ACCOUNTING-CONTROL-MIB.dic +1316 -0
  9. data/lib/mibs/ietf/ADSL-LINE-EXT-MIB.dic +1724 -0
  10. data/lib/mibs/ietf/ADSL-LINE-MIB.dic +7297 -0
  11. data/lib/mibs/ietf/ADSL-TC-MIB.dic +160 -0
  12. data/lib/mibs/ietf/ADSL2-LINE-MIB.dic +8663 -0
  13. data/lib/mibs/ietf/ADSL2-LINE-TC-MIB.dic +1462 -0
  14. data/lib/mibs/ietf/AGENTX-MIB.dic +817 -0
  15. data/lib/mibs/ietf/AGGREGATE-MIB.dic +708 -0
  16. data/lib/mibs/ietf/ALARM-MIB.dic +1734 -0
  17. data/lib/mibs/ietf/APM-MIB.dic +2870 -0
  18. data/lib/mibs/ietf/APPC-MIB.dic +8687 -0
  19. data/lib/mibs/ietf/APPLETALK-MIB.dic +4399 -0
  20. data/lib/mibs/ietf/APPLICATION-MIB.dic +3750 -0
  21. data/lib/mibs/ietf/APPN-DLUR-MIB.dic +972 -0
  22. data/lib/mibs/ietf/APPN-MIB.dic +9364 -0
  23. data/lib/mibs/ietf/APPN-TRAP-MIB.dic +664 -0
  24. data/lib/mibs/ietf/APS-MIB.dic +2430 -0
  25. data/lib/mibs/ietf/ARC-MIB.dic +552 -0
  26. data/lib/mibs/ietf/ATM-ACCOUNTING-INFORMATION-MIB.dic +816 -0
  27. data/lib/mibs/ietf/ATM-MIB.dic +4104 -0
  28. data/lib/mibs/ietf/ATM-TC-MIB.dic +914 -0
  29. data/lib/mibs/ietf/ATM2-MIB.dic +4715 -0
  30. data/lib/mibs/ietf/BFD-STD-MIB.dic +2367 -0
  31. data/lib/mibs/ietf/BFD-TC-STD-MIB.dic +202 -0
  32. data/lib/mibs/ietf/BGP4-MIB.dic +1931 -0
  33. data/lib/mibs/ietf/BLDG-HVAC-MIB.dic +812 -0
  34. data/lib/mibs/ietf/BRIDGE-MIB.dic +2257 -0
  35. data/lib/mibs/ietf/CAPWAP-BASE-MIB.dic +4128 -0
  36. data/lib/mibs/ietf/CAPWAP-DOT11-MIB.dic +482 -0
  37. data/lib/mibs/ietf/CHARACTER-MIB.dic +1140 -0
  38. data/lib/mibs/ietf/CIRCUIT-IF-MIB.dic +493 -0
  39. data/lib/mibs/ietf/CLNS-MIB.dic +1702 -0
  40. data/lib/mibs/ietf/COFFEE-POT-MIB.dic +282 -0
  41. data/lib/mibs/ietf/COPS-CLIENT-MIB.dic +1270 -0
  42. data/lib/mibs/ietf/DECNET-PHIV-MIB.dic +5837 -0
  43. data/lib/mibs/ietf/DIAL-CONTROL-MIB.dic +2139 -0
  44. data/lib/mibs/ietf/DIFFSERV-CONFIG-MIB.dic +378 -0
  45. data/lib/mibs/ietf/DIFFSERV-MIB.dic +5073 -0
  46. data/lib/mibs/ietf/DIRECTORY-SERVER-MIB.dic +1041 -0
  47. data/lib/mibs/ietf/DISMAN-EVENT-MIB.dic +3151 -0
  48. data/lib/mibs/ietf/DISMAN-EXPRESSION-MIB.dic +1716 -0
  49. data/lib/mibs/ietf/DISMAN-NSLOOKUP-MIB.dic +698 -0
  50. data/lib/mibs/ietf/DISMAN-PING-MIB.dic +2635 -0
  51. data/lib/mibs/ietf/DISMAN-SCHEDULE-MIB.dic +1744 -0
  52. data/lib/mibs/ietf/DISMAN-SCRIPT-MIB.dic +2820 -0
  53. data/lib/mibs/ietf/DISMAN-TRACEROUTE-MIB.dic +3239 -0
  54. data/lib/mibs/ietf/DLSW-MIB.dic +5635 -0
  55. data/lib/mibs/ietf/DNS-RESOLVER-MIB.dic +1765 -0
  56. data/lib/mibs/ietf/DNS-SERVER-MIB.dic +1593 -0
  57. data/lib/mibs/ietf/DOCS-BPI-MIB.dic +2634 -0
  58. data/lib/mibs/ietf/DOCS-CABLE-DEVICE-MIB.dic +5042 -0
  59. data/lib/mibs/ietf/DOCS-IETF-BPI2-MIB.dic +5478 -0
  60. data/lib/mibs/ietf/DOCS-IETF-CABLE-DEVICE-NOTIFICATION-MIB.dic +2447 -0
  61. data/lib/mibs/ietf/DOCS-IETF-QOS-MIB.dic +4886 -0
  62. data/lib/mibs/ietf/DOCS-IETF-SUBMGT-MIB.dic +1331 -0
  63. data/lib/mibs/ietf/DOCS-IF-MIB.dic +7980 -0
  64. data/lib/mibs/ietf/DOT12-IF-MIB.dic +1066 -0
  65. data/lib/mibs/ietf/DOT12-RPTR-MIB.dic +2669 -0
  66. data/lib/mibs/ietf/DOT3-EPON-MIB.dic +3297 -0
  67. data/lib/mibs/ietf/DOT3-OAM-MIB.dic +2830 -0
  68. data/lib/mibs/ietf/DS0-MIB.dic +466 -0
  69. data/lib/mibs/ietf/DS0BUNDLE-MIB.dic +468 -0
  70. data/lib/mibs/ietf/DS1-MIB.dic +4890 -0
  71. data/lib/mibs/ietf/DS3-MIB.dic +2719 -0
  72. data/lib/mibs/ietf/DSA-MIB.dic +888 -0
  73. data/lib/mibs/ietf/DSMON-MIB.dic +6177 -0
  74. data/lib/mibs/ietf/DVB-RCS-MIB.dic +5764 -0
  75. data/lib/mibs/ietf/EBN-MIB.dic +1026 -0
  76. data/lib/mibs/ietf/EFM-CU-MIB.dic +4335 -0
  77. data/lib/mibs/ietf/ENTITY-MIB.dic +2235 -0
  78. data/lib/mibs/ietf/ENTITY-SENSOR-MIB.dic +653 -0
  79. data/lib/mibs/ietf/ENTITY-STATE-MIB.dic +457 -0
  80. data/lib/mibs/ietf/ENTITY-STATE-TC-MIB.dic +260 -0
  81. data/lib/mibs/ietf/ETHER-CHIPSET-MIB.dic +787 -0
  82. data/lib/mibs/ietf/EtherLike-MIB.dic +2548 -0
  83. data/lib/mibs/ietf/FC-MGMT-MIB.dic +3465 -0
  84. data/lib/mibs/ietf/FCIP-MGMT-MIB.dic +1596 -0
  85. data/lib/mibs/ietf/FDDI-SMT73-MIB.dic +3378 -0
  86. data/lib/mibs/ietf/FIBRE-CHANNEL-FE-MIB.dic +2504 -0
  87. data/lib/mibs/ietf/FLOAT-TC-MIB.dic +128 -0
  88. data/lib/mibs/ietf/FLOW-METER-MIB.dic +3201 -0
  89. data/lib/mibs/ietf/FORCES-MIB.dic +598 -0
  90. data/lib/mibs/ietf/FR-ATM-PVC-SERVICE-IWF-MIB.dic +1601 -0
  91. data/lib/mibs/ietf/FR-MFR-MIB.dic +1351 -0
  92. data/lib/mibs/ietf/FRAME-RELAY-DTE-MIB.dic +1688 -0
  93. data/lib/mibs/ietf/FRNETSERV-MIB.dic +3940 -0
  94. data/lib/mibs/ietf/FRSLD-MIB.dic +2580 -0
  95. data/lib/mibs/ietf/Finisher-MIB.dic +1416 -0
  96. data/lib/mibs/ietf/GMPLS-LABEL-STD-MIB.dic +965 -0
  97. data/lib/mibs/ietf/GMPLS-LSR-STD-MIB.dic +693 -0
  98. data/lib/mibs/ietf/GMPLS-TC-STD-MIB.dic +180 -0
  99. data/lib/mibs/ietf/GMPLS-TE-STD-MIB.dic +2542 -0
  100. data/lib/mibs/ietf/GSMP-MIB.dic +2468 -0
  101. data/lib/mibs/ietf/HC-ALARM-MIB.dic +1050 -0
  102. data/lib/mibs/ietf/HC-PerfHist-TC-MIB.dic +310 -0
  103. data/lib/mibs/ietf/HC-RMON-MIB.dic +4456 -0
  104. data/lib/mibs/ietf/HDSL2-SHDSL-LINE-MIB.dic +3955 -0
  105. data/lib/mibs/ietf/HOST-RESOURCES-MIB.dic +2453 -0
  106. data/lib/mibs/ietf/HPR-IP-MIB.dic +640 -0
  107. data/lib/mibs/ietf/HPR-MIB.dic +1959 -0
  108. data/lib/mibs/ietf/IANA-ITU-ALARM-TC-MIB.dic +936 -0
  109. data/lib/mibs/ietf/IF-CAP-STACK-MIB.dic +356 -0
  110. data/lib/mibs/ietf/IF-INVERTED-STACK-MIB.dic +220 -0
  111. data/lib/mibs/ietf/IF-MIB.dic +2753 -0
  112. data/lib/mibs/ietf/IFCP-MGMT-MIB.dic +1717 -0
  113. data/lib/mibs/ietf/IGMP-STD-MIB.dic +809 -0
  114. data/lib/mibs/ietf/INET-ADDRESS-MIB.dic +570 -0
  115. data/lib/mibs/ietf/INTEGRATED-SERVICES-GUARANTEED-MIB.dic +319 -0
  116. data/lib/mibs/ietf/INTEGRATED-SERVICES-MIB.dic +1196 -0
  117. data/lib/mibs/ietf/INTERFACETOPN-MIB.dic +1705 -0
  118. data/lib/mibs/ietf/IP-FORWARD-MIB.dic +1853 -0
  119. data/lib/mibs/ietf/IP-MIB.dic +7064 -0
  120. data/lib/mibs/ietf/IPATM-IPMC-MIB.dic +4830 -0
  121. data/lib/mibs/ietf/IPFIX-MIB.dic +2334 -0
  122. data/lib/mibs/ietf/IPFIX-SELECTOR-MIB.dic +215 -0
  123. data/lib/mibs/ietf/IPMCAST-MIB.dic +3390 -0
  124. data/lib/mibs/ietf/IPMROUTE-STD-MIB.dic +1246 -0
  125. data/lib/mibs/ietf/IPOA-MIB.dic +2372 -0
  126. data/lib/mibs/ietf/IPS-AUTH-MIB.dic +1609 -0
  127. data/lib/mibs/ietf/IPSEC-SPD-MIB.dic +3989 -0
  128. data/lib/mibs/ietf/IPV6-FLOW-LABEL-MIB.dic +110 -0
  129. data/lib/mibs/ietf/IPV6-ICMP-MIB.dic +748 -0
  130. data/lib/mibs/ietf/IPV6-MIB.dic +2028 -0
  131. data/lib/mibs/ietf/IPV6-MLD-MIB.dic +659 -0
  132. data/lib/mibs/ietf/IPV6-TCP-MIB.dic +332 -0
  133. data/lib/mibs/ietf/IPV6-UDP-MIB.dic +209 -0
  134. data/lib/mibs/ietf/ISCSI-MIB.dic +4613 -0
  135. data/lib/mibs/ietf/ISDN-MIB.dic +1796 -0
  136. data/lib/mibs/ietf/ISIS-MIB.dic +6215 -0
  137. data/lib/mibs/ietf/ISNS-MIB.dic +6578 -0
  138. data/lib/mibs/ietf/ITU-ALARM-MIB.dic +665 -0
  139. data/lib/mibs/ietf/ITU-ALARM-TC-MIB.dic +137 -0
  140. data/lib/mibs/ietf/Job-Monitoring-MIB.dic +2519 -0
  141. data/lib/mibs/ietf/L2TP-MIB.dic +4050 -0
  142. data/lib/mibs/ietf/LANGTAG-TC-MIB.dic +104 -0
  143. data/lib/mibs/ietf/LISP-MIB.dic +4067 -0
  144. data/lib/mibs/ietf/LMP-MIB.dic +5166 -0
  145. data/lib/mibs/ietf/MALLOC-MIB.dic +2156 -0
  146. data/lib/mibs/ietf/MAU-MIB.dic +2619 -0
  147. data/lib/mibs/ietf/MIDCOM-MIB.dic +2856 -0
  148. data/lib/mibs/ietf/MIOX25-MIB.dic +828 -0
  149. data/lib/mibs/ietf/MIP-MIB.dic +3473 -0
  150. data/lib/mibs/ietf/MOBILEIPV6-MIB.dic +5228 -0
  151. data/lib/mibs/ietf/MPLS-FTN-STD-MIB.dic +1594 -0
  152. data/lib/mibs/ietf/MPLS-L3VPN-STD-MIB.dic +2548 -0
  153. data/lib/mibs/ietf/MPLS-LC-ATM-STD-MIB.dic +491 -0
  154. data/lib/mibs/ietf/MPLS-LC-FR-STD-MIB.dic +395 -0
  155. data/lib/mibs/ietf/MPLS-LDP-ATM-STD-MIB.dic +1019 -0
  156. data/lib/mibs/ietf/MPLS-LDP-FRAME-RELAY-STD-MIB.dic +862 -0
  157. data/lib/mibs/ietf/MPLS-LDP-GENERIC-STD-MIB.dic +445 -0
  158. data/lib/mibs/ietf/MPLS-LDP-STD-MIB.dic +3657 -0
  159. data/lib/mibs/ietf/MPLS-LSR-STD-MIB.dic +3103 -0
  160. data/lib/mibs/ietf/MPLS-TC-STD-MIB.dic +911 -0
  161. data/lib/mibs/ietf/MPLS-TE-STD-MIB.dic +3673 -0
  162. data/lib/mibs/ietf/MSDP-MIB.dic +1893 -0
  163. data/lib/mibs/ietf/MTA-MIB.dic +1898 -0
  164. data/lib/mibs/ietf/Modem-MIB.dic +2054 -0
  165. data/lib/mibs/ietf/NAT-MIB.dic +3866 -0
  166. data/lib/mibs/ietf/NETWORK-SERVICES-MIB.dic +1034 -0
  167. data/lib/mibs/ietf/NHDP-MIB.dic +3005 -0
  168. data/lib/mibs/ietf/NHRP-MIB.dic +3660 -0
  169. data/lib/mibs/ietf/NOTIFICATION-LOG-MIB.dic +1156 -0
  170. data/lib/mibs/ietf/NTPv4-MIB.dic +1535 -0
  171. data/lib/mibs/ietf/OPT-IF-MIB.dic +8972 -0
  172. data/lib/mibs/ietf/OSPF-MIB.dic +5963 -0
  173. data/lib/mibs/ietf/OSPF-TRAP-MIB.dic +1190 -0
  174. data/lib/mibs/ietf/OSPFV3-MIB.dic +5708 -0
  175. data/lib/mibs/ietf/P-BRIDGE-MIB.dic +1499 -0
  176. data/lib/mibs/ietf/PARALLEL-MIB.dic +476 -0
  177. data/lib/mibs/ietf/PIM-MIB.dic +1393 -0
  178. data/lib/mibs/ietf/PIM-STD-MIB.dic +6819 -0
  179. data/lib/mibs/ietf/PINT-MIB.dic +830 -0
  180. data/lib/mibs/ietf/PKTC-IETF-MTA-MIB.dic +3191 -0
  181. data/lib/mibs/ietf/PKTC-IETF-SIG-MIB.dic +4713 -0
  182. data/lib/mibs/ietf/PMIPV6-MIB.dic +3010 -0
  183. data/lib/mibs/ietf/PMIPV6-TC-MIB.dic +293 -0
  184. data/lib/mibs/ietf/POLICY-BASED-MANAGEMENT-MIB.dic +3316 -0
  185. data/lib/mibs/ietf/POWER-ETHERNET-MIB.dic +959 -0
  186. data/lib/mibs/ietf/PPP-BRIDGE-NCP-MIB.dic +587 -0
  187. data/lib/mibs/ietf/PPP-IP-NCP-MIB.dic +269 -0
  188. data/lib/mibs/ietf/PPP-LCP-MIB.dic +994 -0
  189. data/lib/mibs/ietf/PPP-SEC-MIB.dic +411 -0
  190. data/lib/mibs/ietf/PSAMP-MIB.dic +998 -0
  191. data/lib/mibs/ietf/PTOPO-MIB.dic +1135 -0
  192. data/lib/mibs/ietf/PW-ATM-MIB.dic +1642 -0
  193. data/lib/mibs/ietf/PW-CEP-STD-MIB.dic +3661 -0
  194. data/lib/mibs/ietf/PW-STD-MIB.dic +3592 -0
  195. data/lib/mibs/ietf/PW-TC-STD-MIB.dic +437 -0
  196. data/lib/mibs/ietf/PW-TDM-MIB.dic +1896 -0
  197. data/lib/mibs/ietf/PerfHist-TC-MIB.dic +152 -0
  198. data/lib/mibs/ietf/Printer-MIB.dic +6665 -0
  199. data/lib/mibs/ietf/Q-BRIDGE-MIB.dic +3115 -0
  200. data/lib/mibs/ietf/RADIUS-ACC-CLIENT-MIB.dic +991 -0
  201. data/lib/mibs/ietf/RADIUS-ACC-SERVER-MIB.dic +1183 -0
  202. data/lib/mibs/ietf/RADIUS-AUTH-CLIENT-MIB.dic +1073 -0
  203. data/lib/mibs/ietf/RADIUS-AUTH-SERVER-MIB.dic +1251 -0
  204. data/lib/mibs/ietf/RADIUS-DYNAUTH-CLIENT-MIB.dic +1116 -0
  205. data/lib/mibs/ietf/RADIUS-DYNAUTH-SERVER-MIB.dic +1003 -0
  206. data/lib/mibs/ietf/RAQMON-MIB.dic +2695 -0
  207. data/lib/mibs/ietf/RBRIDGE-MIB.dic +2981 -0
  208. data/lib/mibs/ietf/RDBMS-MIB.dic +1935 -0
  209. data/lib/mibs/ietf/RFC1065-SMI.dic +108 -0
  210. data/lib/mibs/ietf/RFC1155-SMI.dic +118 -0
  211. data/lib/mibs/ietf/RFC1158-MIB.dic +2440 -0
  212. data/lib/mibs/ietf/RFC1213-MIB.dic +3434 -0
  213. data/lib/mibs/ietf/RFC1269-MIB.dic +557 -0
  214. data/lib/mibs/ietf/RFC1271-MIB.dic +4135 -0
  215. data/lib/mibs/ietf/RFC1285-MIB.dic +2842 -0
  216. data/lib/mibs/ietf/RFC1316-MIB.dic +800 -0
  217. data/lib/mibs/ietf/RFC1381-MIB.dic +1347 -0
  218. data/lib/mibs/ietf/RFC1382-MIB.dic +3820 -0
  219. data/lib/mibs/ietf/RFC1414-MIB.dic +214 -0
  220. data/lib/mibs/ietf/RIPv2-MIB.dic +773 -0
  221. data/lib/mibs/ietf/RMON-MIB.dic +5551 -0
  222. data/lib/mibs/ietf/RMON2-MIB.dic +8224 -0
  223. data/lib/mibs/ietf/ROHC-MIB.dic +1613 -0
  224. data/lib/mibs/ietf/ROHC-RTP-MIB.dic +859 -0
  225. data/lib/mibs/ietf/ROHC-UNCOMPRESSED-MIB.dic +267 -0
  226. data/lib/mibs/ietf/RPKI-ROUTER-MIB.dic +1363 -0
  227. data/lib/mibs/ietf/RS-232-MIB.dic +1335 -0
  228. data/lib/mibs/ietf/RSERPOOL-MIB.dic +2501 -0
  229. data/lib/mibs/ietf/RSTP-MIB.dic +427 -0
  230. data/lib/mibs/ietf/RSVP-MIB.dic +4135 -0
  231. data/lib/mibs/ietf/RTP-MIB.dic +1376 -0
  232. data/lib/mibs/ietf/SCSI-MIB.dic +3804 -0
  233. data/lib/mibs/ietf/SCTP-MIB.dic +1924 -0
  234. data/lib/mibs/ietf/SFLOW-MIB.dic +568 -0
  235. data/lib/mibs/ietf/SIP-COMMON-MIB.dic +2769 -0
  236. data/lib/mibs/ietf/SIP-MIB.dic +1438 -0
  237. data/lib/mibs/ietf/SIP-SERVER-MIB.dic +1150 -0
  238. data/lib/mibs/ietf/SIP-TC-MIB.dic +257 -0
  239. data/lib/mibs/ietf/SIP-UA-MIB.dic +268 -0
  240. data/lib/mibs/ietf/SLAPM-MIB.dic +4527 -0
  241. data/lib/mibs/ietf/SMON-MIB.dic +1758 -0
  242. data/lib/mibs/ietf/SNA-NAU-MIB.dic +4042 -0
  243. data/lib/mibs/ietf/SNA-SDLC-MIB.dic +3858 -0
  244. data/lib/mibs/ietf/SNMP-COMMUNITY-MIB.dic +715 -0
  245. data/lib/mibs/ietf/SNMP-FRAMEWORK-MIB.dic +709 -0
  246. data/lib/mibs/ietf/SNMP-MPD-MIB.dic +230 -0
  247. data/lib/mibs/ietf/SNMP-NOTIFICATION-MIB.dic +859 -0
  248. data/lib/mibs/ietf/SNMP-PROXY-MIB.dic +414 -0
  249. data/lib/mibs/ietf/SNMP-REPEATER-MIB.dic +4335 -0
  250. data/lib/mibs/ietf/SNMP-SSH-TM-MIB.dic +447 -0
  251. data/lib/mibs/ietf/SNMP-TARGET-MIB.dic +924 -0
  252. data/lib/mibs/ietf/SNMP-TLS-TM-MIB.dic +1449 -0
  253. data/lib/mibs/ietf/SNMP-TSM-MIB.dic +315 -0
  254. data/lib/mibs/ietf/SNMP-USER-BASED-SM-MIB.dic +1164 -0
  255. data/lib/mibs/ietf/SNMP-USM-AES-MIB.dic +95 -0
  256. data/lib/mibs/ietf/SNMP-USM-DH-OBJECTS-MIB.dic +653 -0
  257. data/lib/mibs/ietf/SNMP-VIEW-BASED-ACM-MIB.dic +1202 -0
  258. data/lib/mibs/ietf/SNMPv2-MIB.dic +1382 -0
  259. data/lib/mibs/ietf/SNMPv2-SMI.dic +223 -0
  260. data/lib/mibs/ietf/SNMPv2-USEC-MIB.dic +405 -0
  261. data/lib/mibs/ietf/SONET-MIB.dic +3308 -0
  262. data/lib/mibs/ietf/SOURCE-ROUTING-MIB.dic +542 -0
  263. data/lib/mibs/ietf/SSPM-MIB.dic +1530 -0
  264. data/lib/mibs/ietf/SYSAPPL-MIB.dic +2092 -0
  265. data/lib/mibs/ietf/T11-FC-FABRIC-ADDR-MGR-MIB.dic +1779 -0
  266. data/lib/mibs/ietf/T11-FC-FABRIC-CONFIG-SERVER-MIB.dic +2822 -0
  267. data/lib/mibs/ietf/T11-FC-FABRIC-LOCK-MIB.dic +700 -0
  268. data/lib/mibs/ietf/T11-FC-FSPF-MIB.dic +1889 -0
  269. data/lib/mibs/ietf/T11-FC-NAME-SERVER-MIB.dic +1775 -0
  270. data/lib/mibs/ietf/T11-FC-ROUTE-MIB.dic +655 -0
  271. data/lib/mibs/ietf/T11-FC-RSCN-MIB.dic +1110 -0
  272. data/lib/mibs/ietf/T11-FC-VIRTUAL-FABRIC-MIB.dic +770 -0
  273. data/lib/mibs/ietf/T11-FC-ZONE-SERVER-MIB.dic +3886 -0
  274. data/lib/mibs/ietf/T11-TC-MIB.dic +110 -0
  275. data/lib/mibs/ietf/TCP-ESTATS-MIB.dic +3926 -0
  276. data/lib/mibs/ietf/TCP-MIB.dic +1319 -0
  277. data/lib/mibs/ietf/TCPIPX-MIB.dic +457 -0
  278. data/lib/mibs/ietf/TE-LINK-STD-MIB.dic +2876 -0
  279. data/lib/mibs/ietf/TE-MIB.dic +2924 -0
  280. data/lib/mibs/ietf/TED-MIB.dic +1749 -0
  281. data/lib/mibs/ietf/TIME-AGGREGATE-MIB.dic +550 -0
  282. data/lib/mibs/ietf/TN3270E-MIB.dic +2785 -0
  283. data/lib/mibs/ietf/TN3270E-RT-MIB.dic +1317 -0
  284. data/lib/mibs/ietf/TOKEN-RING-RMON-MIB.dic +2820 -0
  285. data/lib/mibs/ietf/TOKENRING-MIB.dic +1184 -0
  286. data/lib/mibs/ietf/TOKENRING-STATION-SR-MIB.dic +292 -0
  287. data/lib/mibs/ietf/TRANSPORT-ADDRESS-MIB.dic +610 -0
  288. data/lib/mibs/ietf/TRIP-MIB.dic +3159 -0
  289. data/lib/mibs/ietf/TRIP-TC-MIB.dic +241 -0
  290. data/lib/mibs/ietf/TUNNEL-MIB.dic +1095 -0
  291. data/lib/mibs/ietf/UDP-MIB.dic +751 -0
  292. data/lib/mibs/ietf/UDPLITE-MIB.dic +704 -0
  293. data/lib/mibs/ietf/UPS-MIB.dic +3088 -0
  294. data/lib/mibs/ietf/URI-TC-MIB.dic +193 -0
  295. data/lib/mibs/ietf/UUID-TC-MIB.dic +135 -0
  296. data/lib/mibs/ietf/VDSL-LINE-EXT-MCM-MIB.dic +989 -0
  297. data/lib/mibs/ietf/VDSL-LINE-EXT-SCM-MIB.dic +605 -0
  298. data/lib/mibs/ietf/VDSL-LINE-MIB.dic +4518 -0
  299. data/lib/mibs/ietf/VDSL2-LINE-MIB.dic +11029 -0
  300. data/lib/mibs/ietf/VDSL2-LINE-TC-MIB.dic +3152 -0
  301. data/lib/mibs/ietf/VPN-TC-STD-MIB.dic +121 -0
  302. data/lib/mibs/ietf/VRRP-MIB.dic +1163 -0
  303. data/lib/mibs/ietf/VRRPV3-MIB.dic +1403 -0
  304. data/lib/mibs/ietf/WWW-MIB.dic +1810 -0
  305. data/lib/mibs/logstash/iso.dic +18 -0
  306. data/logstash-input-snmp.gemspec +1 -1
  307. data/spec/inputs/snmp/mib_spec.rb +10 -17
  308. data/spec/inputs/snmp_spec.rb +27 -1
  309. metadata +302 -2
@@ -0,0 +1,1347 @@
1
+ # python version 1.0 DO NOT EDIT
2
+ #
3
+ # This python file has been generated by smidump version 0.5.0:
4
+ #
5
+ # smidump -f python RFC1381-MIB
6
+
7
+ FILENAME = "./libsmi-0.5.0/mibs/ietf/RFC1381-MIB"
8
+
9
+ MIB = {
10
+ "moduleName" : "RFC1381-MIB",
11
+
12
+ "RFC1381-MIB" : {
13
+ "nodetype" : "module",
14
+ "language" : "SMIv1",
15
+ },
16
+
17
+ "imports" : (
18
+ {"module" : "RFC1155-SMI", "name" : "Counter"},
19
+ {"module" : "RFC1213-MIB", "name" : "transmission"},
20
+ {"module" : "RFC-1212", "name" : "OBJECT-TYPE"},
21
+ ),
22
+
23
+ "typedefs" : {
24
+ "PositiveInteger" : {
25
+ "basetype" : "Integer32",
26
+ "ranges" : [
27
+ {
28
+ "min" : "0",
29
+ "max" : "2147483647"
30
+ },
31
+ ],
32
+ "range" : {
33
+ "min" : "0",
34
+ "max" : "2147483647"
35
+ },
36
+ },
37
+ "IfIndexType" : {
38
+ "basetype" : "Integer32",
39
+ "ranges" : [
40
+ {
41
+ "min" : "1",
42
+ "max" : "2147483647"
43
+ },
44
+ ],
45
+ "range" : {
46
+ "min" : "1",
47
+ "max" : "2147483647"
48
+ },
49
+ },
50
+ }, # typedefs
51
+
52
+ "nodes" : {
53
+ "lapb" : {
54
+ "nodetype" : "node",
55
+ "moduleName" : "RFC1381-MIB",
56
+ "oid" : "1.3.6.1.2.1.10.16",
57
+ }, # node
58
+ "lapbAdmnTable" : {
59
+ "nodetype" : "table",
60
+ "moduleName" : "RFC1381-MIB",
61
+ "oid" : "1.3.6.1.2.1.10.16.1",
62
+ "status" : "current",
63
+ "description" :
64
+ """This table contains objects that can be
65
+ changed to manage a LAPB interface.
66
+ Changing one of these parameters may take
67
+ effect in the operating LAPB immediately or
68
+ may wait until the interface is restarted
69
+ depending on the details of the
70
+ implementation.
71
+
72
+ Most of the objects in this read-write table
73
+ have corresponding read-only objects in the
74
+ lapbOperTable that return the current
75
+ operating value.
76
+
77
+ The operating values may be different from
78
+ these configured values if changed by XID
79
+ negotiation or if a configured parameter was
80
+ changed after the interface was started.""",
81
+ }, # table
82
+ "lapbAdmnEntry" : {
83
+ "nodetype" : "row",
84
+ "moduleName" : "RFC1381-MIB",
85
+ "oid" : "1.3.6.1.2.1.10.16.1.1",
86
+ "status" : "current",
87
+ "linkage" : [
88
+ "lapbAdmnIndex",
89
+ ],
90
+ "description" :
91
+ """Configured parameter values for a specific
92
+ LAPB.""",
93
+ }, # row
94
+ "lapbAdmnIndex" : {
95
+ "nodetype" : "column",
96
+ "moduleName" : "RFC1381-MIB",
97
+ "oid" : "1.3.6.1.2.1.10.16.1.1.1",
98
+ "status" : "current",
99
+ "syntax" : {
100
+ "type" : { "module" :"RFC1381-MIB", "name" : "IfIndexType"},
101
+ },
102
+ "access" : "readonly",
103
+ "description" :
104
+ """The ifIndex value for the LAPB interface.""",
105
+ }, # column
106
+ "lapbAdmnStationType" : {
107
+ "nodetype" : "column",
108
+ "moduleName" : "RFC1381-MIB",
109
+ "oid" : "1.3.6.1.2.1.10.16.1.1.2",
110
+ "status" : "current",
111
+ "syntax" : {
112
+ "type" : {
113
+ "basetype" : "Enumeration",
114
+ "dte" : {
115
+ "nodetype" : "namednumber",
116
+ "number" : "1"
117
+ },
118
+ "dce" : {
119
+ "nodetype" : "namednumber",
120
+ "number" : "2"
121
+ },
122
+ "dxe" : {
123
+ "nodetype" : "namednumber",
124
+ "number" : "3"
125
+ },
126
+ },
127
+ },
128
+ "access" : "readwrite",
129
+ "default" : "dte",
130
+ "description" :
131
+ """Identifies the desired station type of this
132
+ interface.""",
133
+ "reference" :
134
+ """ISO 7776 section 3.1""",
135
+ }, # column
136
+ "lapbAdmnControlField" : {
137
+ "nodetype" : "column",
138
+ "moduleName" : "RFC1381-MIB",
139
+ "oid" : "1.3.6.1.2.1.10.16.1.1.3",
140
+ "status" : "current",
141
+ "syntax" : {
142
+ "type" : {
143
+ "basetype" : "Enumeration",
144
+ "modulo8" : {
145
+ "nodetype" : "namednumber",
146
+ "number" : "1"
147
+ },
148
+ "modulo128" : {
149
+ "nodetype" : "namednumber",
150
+ "number" : "2"
151
+ },
152
+ },
153
+ },
154
+ "access" : "readwrite",
155
+ "default" : "modulo8",
156
+ "description" :
157
+ """The desired size of the sequence numbers
158
+ used to number frames.""",
159
+ "reference" :
160
+ """ISO 8885 Table 3, Name: HDLC Option - 10""",
161
+ }, # column
162
+ "lapbAdmnTransmitN1FrameSize" : {
163
+ "nodetype" : "column",
164
+ "moduleName" : "RFC1381-MIB",
165
+ "oid" : "1.3.6.1.2.1.10.16.1.1.4",
166
+ "status" : "current",
167
+ "syntax" : {
168
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
169
+ },
170
+ "access" : "readwrite",
171
+ "default" : "36000",
172
+ "description" :
173
+ """The default maximum N1 frame size desired
174
+ in number of bits for a frame transmitted by
175
+ this DTE. This excludes flags and 0 bits
176
+ inserted for transparency.""",
177
+ "reference" :
178
+ """ISO 8885 Table 3,
179
+ Name: Information Field length""",
180
+ }, # column
181
+ "lapbAdmnReceiveN1FrameSize" : {
182
+ "nodetype" : "column",
183
+ "moduleName" : "RFC1381-MIB",
184
+ "oid" : "1.3.6.1.2.1.10.16.1.1.5",
185
+ "status" : "current",
186
+ "syntax" : {
187
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
188
+ },
189
+ "access" : "readwrite",
190
+ "default" : "36000",
191
+ "description" :
192
+ """The default maximum N1 frame size desired
193
+ in number of bits for a frame the DCE/remote
194
+ DTE transmits to this DTE. This excludes
195
+ flags and 0 bits inserted for transparency.""",
196
+ }, # column
197
+ "lapbAdmnTransmitKWindowSize" : {
198
+ "nodetype" : "column",
199
+ "moduleName" : "RFC1381-MIB",
200
+ "oid" : "1.3.6.1.2.1.10.16.1.1.6",
201
+ "status" : "current",
202
+ "syntax" : {
203
+ "type" : {
204
+ "basetype" : "Integer32",
205
+ "ranges" : [
206
+ {
207
+ "min" : "1",
208
+ "max" : "127"
209
+ },
210
+ ],
211
+ "range" : {
212
+ "min" : "1",
213
+ "max" : "127"
214
+ },
215
+ },
216
+ },
217
+ "access" : "readwrite",
218
+ "default" : "7",
219
+ "description" :
220
+ """The default transmit window size for this
221
+ Interface. This is the maximum number of
222
+ unacknowledged sequenced PDUs that may be
223
+ outstanding from this DTE at any one time.""",
224
+ "reference" :
225
+ """ISO 8885 Table 3, Name: Window size""",
226
+ }, # column
227
+ "lapbAdmnReceiveKWindowSize" : {
228
+ "nodetype" : "column",
229
+ "moduleName" : "RFC1381-MIB",
230
+ "oid" : "1.3.6.1.2.1.10.16.1.1.7",
231
+ "status" : "current",
232
+ "syntax" : {
233
+ "type" : {
234
+ "basetype" : "Integer32",
235
+ "ranges" : [
236
+ {
237
+ "min" : "1",
238
+ "max" : "127"
239
+ },
240
+ ],
241
+ "range" : {
242
+ "min" : "1",
243
+ "max" : "127"
244
+ },
245
+ },
246
+ },
247
+ "access" : "readwrite",
248
+ "default" : "7",
249
+ "description" :
250
+ """The default receive window size for this
251
+ Interface. This is the maximum number of
252
+ unacknowledged sequenced PDUs that may be
253
+ outstanding from the DCE/remote DTE at any
254
+ one time.""",
255
+ "reference" :
256
+ """ISO 8885 Table 3, Name: Window size""",
257
+ }, # column
258
+ "lapbAdmnN2RxmitCount" : {
259
+ "nodetype" : "column",
260
+ "moduleName" : "RFC1381-MIB",
261
+ "oid" : "1.3.6.1.2.1.10.16.1.1.8",
262
+ "status" : "current",
263
+ "syntax" : {
264
+ "type" : {
265
+ "basetype" : "Integer32",
266
+ "ranges" : [
267
+ {
268
+ "min" : "0",
269
+ "max" : "65535"
270
+ },
271
+ ],
272
+ "range" : {
273
+ "min" : "0",
274
+ "max" : "65535"
275
+ },
276
+ },
277
+ },
278
+ "access" : "readwrite",
279
+ "default" : "20",
280
+ "description" :
281
+ """The default N2 retry counter for this
282
+ interface. This specifies the number of
283
+ times a PDU will be resent after the T1
284
+ timer expires without an acknowledgement for
285
+ the PDU.""",
286
+ "reference" :
287
+ """ISO 8885 Table 3,
288
+ Name: Retransmission Attempts""",
289
+ }, # column
290
+ "lapbAdmnT1AckTimer" : {
291
+ "nodetype" : "column",
292
+ "moduleName" : "RFC1381-MIB",
293
+ "oid" : "1.3.6.1.2.1.10.16.1.1.9",
294
+ "status" : "current",
295
+ "syntax" : {
296
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
297
+ },
298
+ "access" : "readwrite",
299
+ "default" : "3000",
300
+ "description" :
301
+ """The default T1 timer for this interface.
302
+ This specifies the maximum time in
303
+ Milliseconds to wait for acknowledgment of a
304
+ PDU.""",
305
+ "reference" :
306
+ """ISO 8885 Table 3, Name:
307
+ Acknowledgement timer""",
308
+ }, # column
309
+ "lapbAdmnT2AckDelayTimer" : {
310
+ "nodetype" : "column",
311
+ "moduleName" : "RFC1381-MIB",
312
+ "oid" : "1.3.6.1.2.1.10.16.1.1.10",
313
+ "status" : "current",
314
+ "syntax" : {
315
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
316
+ },
317
+ "access" : "readwrite",
318
+ "default" : "0",
319
+ "description" :
320
+ """The default T2 timer for this interface.
321
+ This specifies the maximum time in
322
+ Milliseconds to wait before sending an
323
+ acknowledgment for a sequenced PDU. A value
324
+ of zero means there will be no delay in
325
+ acknowledgement generation.""",
326
+ "reference" :
327
+ """ISO 8885 Table 3,
328
+ Name: Reply delay timer""",
329
+ }, # column
330
+ "lapbAdmnT3DisconnectTimer" : {
331
+ "nodetype" : "column",
332
+ "moduleName" : "RFC1381-MIB",
333
+ "oid" : "1.3.6.1.2.1.10.16.1.1.11",
334
+ "status" : "current",
335
+ "syntax" : {
336
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
337
+ },
338
+ "access" : "readwrite",
339
+ "default" : "60000",
340
+ "description" :
341
+ """The T3 timer for this interface. This
342
+ specifies the time in Milliseconds to wait
343
+ before considering the link disconnected. A
344
+ value of zero indicates the link will be
345
+ considered disconnected upon completion of
346
+ the frame exchange to disconnect the link.""",
347
+ "reference" :
348
+ """ISO 7776 section 5.7.1.3""",
349
+ }, # column
350
+ "lapbAdmnT4IdleTimer" : {
351
+ "nodetype" : "column",
352
+ "moduleName" : "RFC1381-MIB",
353
+ "oid" : "1.3.6.1.2.1.10.16.1.1.12",
354
+ "status" : "current",
355
+ "syntax" : {
356
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
357
+ },
358
+ "access" : "readwrite",
359
+ "default" : "2147483647",
360
+ "description" :
361
+ """The T4 timer for this interface. This
362
+ specifies the maximum time in Milliseconds
363
+ to allow without frames being exchanged on
364
+ the data link. A value of 2147483647
365
+ indicates no idle timer is being kept.""",
366
+ "reference" :
367
+ """ISO 7776 section 5.7.1.4""",
368
+ }, # column
369
+ "lapbAdmnActionInitiate" : {
370
+ "nodetype" : "column",
371
+ "moduleName" : "RFC1381-MIB",
372
+ "oid" : "1.3.6.1.2.1.10.16.1.1.13",
373
+ "status" : "current",
374
+ "syntax" : {
375
+ "type" : {
376
+ "basetype" : "Enumeration",
377
+ "sendSABM" : {
378
+ "nodetype" : "namednumber",
379
+ "number" : "1"
380
+ },
381
+ "sendDISC" : {
382
+ "nodetype" : "namednumber",
383
+ "number" : "2"
384
+ },
385
+ "sendDM" : {
386
+ "nodetype" : "namednumber",
387
+ "number" : "3"
388
+ },
389
+ "none" : {
390
+ "nodetype" : "namednumber",
391
+ "number" : "4"
392
+ },
393
+ "other" : {
394
+ "nodetype" : "namednumber",
395
+ "number" : "5"
396
+ },
397
+ },
398
+ },
399
+ "access" : "readwrite",
400
+ "default" : "sendSABM",
401
+ "description" :
402
+ """This identifies the action LAPB will take
403
+ to initiate link set-up.""",
404
+ }, # column
405
+ "lapbAdmnActionRecvDM" : {
406
+ "nodetype" : "column",
407
+ "moduleName" : "RFC1381-MIB",
408
+ "oid" : "1.3.6.1.2.1.10.16.1.1.14",
409
+ "status" : "current",
410
+ "syntax" : {
411
+ "type" : {
412
+ "basetype" : "Enumeration",
413
+ "sendSABM" : {
414
+ "nodetype" : "namednumber",
415
+ "number" : "1"
416
+ },
417
+ "sendDISC" : {
418
+ "nodetype" : "namednumber",
419
+ "number" : "2"
420
+ },
421
+ "other" : {
422
+ "nodetype" : "namednumber",
423
+ "number" : "3"
424
+ },
425
+ },
426
+ },
427
+ "access" : "readwrite",
428
+ "default" : "sendSABM",
429
+ "description" :
430
+ """This identifies the action LAPB will take
431
+ when it receives a DM response.""",
432
+ }, # column
433
+ "lapbOperTable" : {
434
+ "nodetype" : "table",
435
+ "moduleName" : "RFC1381-MIB",
436
+ "oid" : "1.3.6.1.2.1.10.16.2",
437
+ "status" : "current",
438
+ "description" :
439
+ """This table contains configuration
440
+ information about interface parameters
441
+ currently set in the interface. Many of
442
+ these objects have corresponding objects in
443
+ the lapbAdmnTable.""",
444
+ }, # table
445
+ "lapbOperEntry" : {
446
+ "nodetype" : "row",
447
+ "moduleName" : "RFC1381-MIB",
448
+ "oid" : "1.3.6.1.2.1.10.16.2.1",
449
+ "status" : "current",
450
+ "linkage" : [
451
+ "lapbOperIndex",
452
+ ],
453
+ "description" :
454
+ """Currently set parameter values for a
455
+ specific LAPB.""",
456
+ }, # row
457
+ "lapbOperIndex" : {
458
+ "nodetype" : "column",
459
+ "moduleName" : "RFC1381-MIB",
460
+ "oid" : "1.3.6.1.2.1.10.16.2.1.1",
461
+ "status" : "current",
462
+ "syntax" : {
463
+ "type" : { "module" :"RFC1381-MIB", "name" : "IfIndexType"},
464
+ },
465
+ "access" : "readonly",
466
+ "description" :
467
+ """The ifIndex value for the LAPB interface.""",
468
+ }, # column
469
+ "lapbOperStationType" : {
470
+ "nodetype" : "column",
471
+ "moduleName" : "RFC1381-MIB",
472
+ "oid" : "1.3.6.1.2.1.10.16.2.1.2",
473
+ "status" : "current",
474
+ "syntax" : {
475
+ "type" : {
476
+ "basetype" : "Enumeration",
477
+ "dte" : {
478
+ "nodetype" : "namednumber",
479
+ "number" : "1"
480
+ },
481
+ "dce" : {
482
+ "nodetype" : "namednumber",
483
+ "number" : "2"
484
+ },
485
+ "dxe" : {
486
+ "nodetype" : "namednumber",
487
+ "number" : "3"
488
+ },
489
+ },
490
+ },
491
+ "access" : "readonly",
492
+ "description" :
493
+ """Identifies the current operating station
494
+ type of this interface. A value of dxe (3)
495
+ indicates XID negotiation has not yet taken
496
+ place.""",
497
+ "reference" :
498
+ """ISO 7776 section 3.1""",
499
+ }, # column
500
+ "lapbOperControlField" : {
501
+ "nodetype" : "column",
502
+ "moduleName" : "RFC1381-MIB",
503
+ "oid" : "1.3.6.1.2.1.10.16.2.1.3",
504
+ "status" : "current",
505
+ "syntax" : {
506
+ "type" : {
507
+ "basetype" : "Enumeration",
508
+ "modulo8" : {
509
+ "nodetype" : "namednumber",
510
+ "number" : "1"
511
+ },
512
+ "modulo128" : {
513
+ "nodetype" : "namednumber",
514
+ "number" : "2"
515
+ },
516
+ },
517
+ },
518
+ "access" : "readonly",
519
+ "description" :
520
+ """The current operating size of the sequence
521
+ numbers used to number frames.""",
522
+ "reference" :
523
+ """ISO 7776 section 3.3""",
524
+ }, # column
525
+ "lapbOperTransmitN1FrameSize" : {
526
+ "nodetype" : "column",
527
+ "moduleName" : "RFC1381-MIB",
528
+ "oid" : "1.3.6.1.2.1.10.16.2.1.4",
529
+ "status" : "current",
530
+ "syntax" : {
531
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
532
+ },
533
+ "access" : "readonly",
534
+ "description" :
535
+ """The current operating N1 frame size used
536
+ for the maximum number of bits in a frame
537
+ this DTE can transmit. This excludes flags
538
+ and 0 bits inserted for transparency.""",
539
+ "reference" :
540
+ """ISO 7776 section 5.7.3""",
541
+ }, # column
542
+ "lapbOperReceiveN1FrameSize" : {
543
+ "nodetype" : "column",
544
+ "moduleName" : "RFC1381-MIB",
545
+ "oid" : "1.3.6.1.2.1.10.16.2.1.5",
546
+ "status" : "current",
547
+ "syntax" : {
548
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
549
+ },
550
+ "access" : "readonly",
551
+ "description" :
552
+ """The current operating N1 frame size used
553
+ for the maximum number of bits in a frame
554
+ the DCE/remote DTE can transmit. This
555
+ excludes flags and 0 bits inserted for
556
+ transparency.""",
557
+ }, # column
558
+ "lapbOperTransmitKWindowSize" : {
559
+ "nodetype" : "column",
560
+ "moduleName" : "RFC1381-MIB",
561
+ "oid" : "1.3.6.1.2.1.10.16.2.1.6",
562
+ "status" : "current",
563
+ "syntax" : {
564
+ "type" : {
565
+ "basetype" : "Integer32",
566
+ "ranges" : [
567
+ {
568
+ "min" : "1",
569
+ "max" : "127"
570
+ },
571
+ ],
572
+ "range" : {
573
+ "min" : "1",
574
+ "max" : "127"
575
+ },
576
+ },
577
+ },
578
+ "access" : "readonly",
579
+ "description" :
580
+ """The current PDU window size this Interface
581
+ uses to transmit. This is the maximum
582
+ number of unacknowledged sequenced PDUs that
583
+ may be outstanding from this DTE at any one
584
+ time.""",
585
+ "reference" :
586
+ """ISO 7776 section 5.7.4""",
587
+ }, # column
588
+ "lapbOperReceiveKWindowSize" : {
589
+ "nodetype" : "column",
590
+ "moduleName" : "RFC1381-MIB",
591
+ "oid" : "1.3.6.1.2.1.10.16.2.1.7",
592
+ "status" : "current",
593
+ "syntax" : {
594
+ "type" : {
595
+ "basetype" : "Integer32",
596
+ "ranges" : [
597
+ {
598
+ "min" : "1",
599
+ "max" : "127"
600
+ },
601
+ ],
602
+ "range" : {
603
+ "min" : "1",
604
+ "max" : "127"
605
+ },
606
+ },
607
+ },
608
+ "access" : "readonly",
609
+ "description" :
610
+ """The current receive PDU window size for
611
+ this Interface. This is the maximum number
612
+ of unacknowledged sequenced PDUs that may be
613
+ outstanding from the DCE/remote DTE at any
614
+ one time.""",
615
+ "reference" :
616
+ """ISO 7776 section 5.7.4""",
617
+ }, # column
618
+ "lapbOperN2RxmitCount" : {
619
+ "nodetype" : "column",
620
+ "moduleName" : "RFC1381-MIB",
621
+ "oid" : "1.3.6.1.2.1.10.16.2.1.8",
622
+ "status" : "current",
623
+ "syntax" : {
624
+ "type" : {
625
+ "basetype" : "Integer32",
626
+ "ranges" : [
627
+ {
628
+ "min" : "0",
629
+ "max" : "65535"
630
+ },
631
+ ],
632
+ "range" : {
633
+ "min" : "0",
634
+ "max" : "65535"
635
+ },
636
+ },
637
+ },
638
+ "access" : "readonly",
639
+ "description" :
640
+ """The current N2 retry counter used for this
641
+ interface. This specifies the number of
642
+ times a PDU will be resent after the T1
643
+ timer expires without an acknowledgement for
644
+ the PDU.""",
645
+ "reference" :
646
+ """ISO 7776 section 5.7.2""",
647
+ }, # column
648
+ "lapbOperT1AckTimer" : {
649
+ "nodetype" : "column",
650
+ "moduleName" : "RFC1381-MIB",
651
+ "oid" : "1.3.6.1.2.1.10.16.2.1.9",
652
+ "status" : "current",
653
+ "syntax" : {
654
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
655
+ },
656
+ "access" : "readonly",
657
+ "description" :
658
+ """The current T1 timer for this interface.
659
+ This specifies the maximum time in
660
+ Milliseconds to wait for acknowledgment of a
661
+ PDU.""",
662
+ "reference" :
663
+ """ISO 7776 section 5.7.1.1""",
664
+ }, # column
665
+ "lapbOperT2AckDelayTimer" : {
666
+ "nodetype" : "column",
667
+ "moduleName" : "RFC1381-MIB",
668
+ "oid" : "1.3.6.1.2.1.10.16.2.1.10",
669
+ "status" : "current",
670
+ "syntax" : {
671
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
672
+ },
673
+ "access" : "readonly",
674
+ "description" :
675
+ """The current T2 timer for this interface.
676
+ This specifies the maximum time in
677
+ Milliseconds to wait before sending an
678
+ acknowledgment for a sequenced PDU. A value
679
+ of zero means there will be no delay in
680
+ acknowledgement generation.""",
681
+ "reference" :
682
+ """ISO 7776 section 5.7.1.2""",
683
+ }, # column
684
+ "lapbOperT3DisconnectTimer" : {
685
+ "nodetype" : "column",
686
+ "moduleName" : "RFC1381-MIB",
687
+ "oid" : "1.3.6.1.2.1.10.16.2.1.11",
688
+ "status" : "current",
689
+ "syntax" : {
690
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
691
+ },
692
+ "access" : "readonly",
693
+ "description" :
694
+ """The current T3 timer for this interface.
695
+ This specifies the time in Milliseconds to
696
+ wait before considering the link
697
+ disconnected. A value of zero indicates the
698
+ link will be considered disconnected upon
699
+ completion of the frame exchange to
700
+ disconnect the link.""",
701
+ "reference" :
702
+ """ISO 7776 section 5.7.1.3""",
703
+ }, # column
704
+ "lapbOperT4IdleTimer" : {
705
+ "nodetype" : "column",
706
+ "moduleName" : "RFC1381-MIB",
707
+ "oid" : "1.3.6.1.2.1.10.16.2.1.12",
708
+ "status" : "current",
709
+ "syntax" : {
710
+ "type" : { "module" :"RFC1381-MIB", "name" : "PositiveInteger"},
711
+ },
712
+ "access" : "readwrite",
713
+ "description" :
714
+ """The current T4 timer for this interface.
715
+ This specifies the maximum time in
716
+ Milliseconds to allow without frames being
717
+ exchanged on the data link. A value of
718
+ 2147483647 indicates no idle timer is being
719
+ kept.""",
720
+ "reference" :
721
+ """ISO 7776 section 5.7.1.4""",
722
+ }, # column
723
+ "lapbOperPortId" : {
724
+ "nodetype" : "column",
725
+ "moduleName" : "RFC1381-MIB",
726
+ "oid" : "1.3.6.1.2.1.10.16.2.1.13",
727
+ "status" : "current",
728
+ "syntax" : {
729
+ "type" : { "module" :"", "name" : "ObjectIdentifier"},
730
+ },
731
+ "access" : "readonly",
732
+ "description" :
733
+ """This object identifies an instance of the
734
+ index object in the first group of objects
735
+ in the MIB specific to the physical device
736
+ or interface used to send and receive
737
+ frames. If an agent does not support any
738
+ such objects, it should return nullSpec
739
+ OBJECT IDENTIFIER {0 0}.""",
740
+ }, # column
741
+ "lapbOperProtocolVersionId" : {
742
+ "nodetype" : "column",
743
+ "moduleName" : "RFC1381-MIB",
744
+ "oid" : "1.3.6.1.2.1.10.16.2.1.14",
745
+ "status" : "current",
746
+ "syntax" : {
747
+ "type" : { "module" :"", "name" : "ObjectIdentifier"},
748
+ },
749
+ "access" : "readonly",
750
+ "description" :
751
+ """This object identifies the version of the
752
+ lapb protocol implemented by this
753
+ interface.""",
754
+ }, # column
755
+ "lapbFlowTable" : {
756
+ "nodetype" : "table",
757
+ "moduleName" : "RFC1381-MIB",
758
+ "oid" : "1.3.6.1.2.1.10.16.3",
759
+ "status" : "current",
760
+ "description" :
761
+ """This table defines the objects recorded by
762
+ LAPB to provide information about the
763
+ traffic flow through the interface.""",
764
+ }, # table
765
+ "lapbFlowEntry" : {
766
+ "nodetype" : "row",
767
+ "moduleName" : "RFC1381-MIB",
768
+ "oid" : "1.3.6.1.2.1.10.16.3.1",
769
+ "status" : "current",
770
+ "linkage" : [
771
+ "lapbFlowIfIndex",
772
+ ],
773
+ "description" :
774
+ """The information regarding the effects of
775
+ flow controls in LAPB.""",
776
+ }, # row
777
+ "lapbFlowIfIndex" : {
778
+ "nodetype" : "column",
779
+ "moduleName" : "RFC1381-MIB",
780
+ "oid" : "1.3.6.1.2.1.10.16.3.1.1",
781
+ "status" : "current",
782
+ "syntax" : {
783
+ "type" : { "module" :"RFC1381-MIB", "name" : "IfIndexType"},
784
+ },
785
+ "access" : "readonly",
786
+ "description" :
787
+ """The ifIndex value for the LAPB Interface.""",
788
+ }, # column
789
+ "lapbFlowStateChanges" : {
790
+ "nodetype" : "column",
791
+ "moduleName" : "RFC1381-MIB",
792
+ "oid" : "1.3.6.1.2.1.10.16.3.1.2",
793
+ "status" : "current",
794
+ "syntax" : {
795
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
796
+ },
797
+ "access" : "readonly",
798
+ "description" :
799
+ """The number of LAPB State Changes, including
800
+ resets.""",
801
+ }, # column
802
+ "lapbFlowChangeReason" : {
803
+ "nodetype" : "column",
804
+ "moduleName" : "RFC1381-MIB",
805
+ "oid" : "1.3.6.1.2.1.10.16.3.1.3",
806
+ "status" : "current",
807
+ "syntax" : {
808
+ "type" : {
809
+ "basetype" : "Enumeration",
810
+ "notStarted" : {
811
+ "nodetype" : "namednumber",
812
+ "number" : "1"
813
+ },
814
+ "abmEntered" : {
815
+ "nodetype" : "namednumber",
816
+ "number" : "2"
817
+ },
818
+ "abmeEntered" : {
819
+ "nodetype" : "namednumber",
820
+ "number" : "3"
821
+ },
822
+ "abmReset" : {
823
+ "nodetype" : "namednumber",
824
+ "number" : "4"
825
+ },
826
+ "abmeReset" : {
827
+ "nodetype" : "namednumber",
828
+ "number" : "5"
829
+ },
830
+ "dmReceived" : {
831
+ "nodetype" : "namednumber",
832
+ "number" : "6"
833
+ },
834
+ "dmSent" : {
835
+ "nodetype" : "namednumber",
836
+ "number" : "7"
837
+ },
838
+ "discReceived" : {
839
+ "nodetype" : "namednumber",
840
+ "number" : "8"
841
+ },
842
+ "discSent" : {
843
+ "nodetype" : "namednumber",
844
+ "number" : "9"
845
+ },
846
+ "frmrReceived" : {
847
+ "nodetype" : "namednumber",
848
+ "number" : "10"
849
+ },
850
+ "frmrSent" : {
851
+ "nodetype" : "namednumber",
852
+ "number" : "11"
853
+ },
854
+ "n2Timeout" : {
855
+ "nodetype" : "namednumber",
856
+ "number" : "12"
857
+ },
858
+ "other" : {
859
+ "nodetype" : "namednumber",
860
+ "number" : "13"
861
+ },
862
+ },
863
+ },
864
+ "access" : "readonly",
865
+ "description" :
866
+ """The reason for the most recent incrementing
867
+ of lapbFlowStateChanges. A DM or DISC frame
868
+ generated to initiate link set-up does not
869
+ alter this object. When the MIB-II object
870
+ ifOperStatus does not have a value of
871
+ testing, there exists a correlation between
872
+ this object and ifOperStatus. IfOperStatus
873
+ will have a value of up when this object
874
+ contains: abmEntered, abmeEntered,
875
+ abmReset, or abmeReset. IfOperStatus will
876
+ have a value of down when this object has a
877
+ value of notStarted, or dmReceived through
878
+ n2Timeout. There is no correlation when
879
+ this object has the value other.""",
880
+ }, # column
881
+ "lapbFlowCurrentMode" : {
882
+ "nodetype" : "column",
883
+ "moduleName" : "RFC1381-MIB",
884
+ "oid" : "1.3.6.1.2.1.10.16.3.1.4",
885
+ "status" : "current",
886
+ "syntax" : {
887
+ "type" : {
888
+ "basetype" : "Enumeration",
889
+ "disconnected" : {
890
+ "nodetype" : "namednumber",
891
+ "number" : "1"
892
+ },
893
+ "linkSetup" : {
894
+ "nodetype" : "namednumber",
895
+ "number" : "2"
896
+ },
897
+ "frameReject" : {
898
+ "nodetype" : "namednumber",
899
+ "number" : "3"
900
+ },
901
+ "disconnectRequest" : {
902
+ "nodetype" : "namednumber",
903
+ "number" : "4"
904
+ },
905
+ "informationTransfer" : {
906
+ "nodetype" : "namednumber",
907
+ "number" : "5"
908
+ },
909
+ "rejFrameSent" : {
910
+ "nodetype" : "namednumber",
911
+ "number" : "6"
912
+ },
913
+ "waitingAcknowledgement" : {
914
+ "nodetype" : "namednumber",
915
+ "number" : "7"
916
+ },
917
+ "stationBusy" : {
918
+ "nodetype" : "namednumber",
919
+ "number" : "8"
920
+ },
921
+ "remoteStationBusy" : {
922
+ "nodetype" : "namednumber",
923
+ "number" : "9"
924
+ },
925
+ "bothStationsBusy" : {
926
+ "nodetype" : "namednumber",
927
+ "number" : "10"
928
+ },
929
+ "waitingAckStationBusy" : {
930
+ "nodetype" : "namednumber",
931
+ "number" : "11"
932
+ },
933
+ "waitingAckRemoteBusy" : {
934
+ "nodetype" : "namednumber",
935
+ "number" : "12"
936
+ },
937
+ "waitingAckBothBusy" : {
938
+ "nodetype" : "namednumber",
939
+ "number" : "13"
940
+ },
941
+ "rejFrameSentRemoteBusy" : {
942
+ "nodetype" : "namednumber",
943
+ "number" : "14"
944
+ },
945
+ "xidFrameSent" : {
946
+ "nodetype" : "namednumber",
947
+ "number" : "15"
948
+ },
949
+ "error" : {
950
+ "nodetype" : "namednumber",
951
+ "number" : "16"
952
+ },
953
+ "other" : {
954
+ "nodetype" : "namednumber",
955
+ "number" : "17"
956
+ },
957
+ },
958
+ },
959
+ "access" : "readonly",
960
+ "description" :
961
+ """The current condition of the conversation.""",
962
+ }, # column
963
+ "lapbFlowBusyDefers" : {
964
+ "nodetype" : "column",
965
+ "moduleName" : "RFC1381-MIB",
966
+ "oid" : "1.3.6.1.2.1.10.16.3.1.5",
967
+ "status" : "current",
968
+ "syntax" : {
969
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
970
+ },
971
+ "access" : "readonly",
972
+ "description" :
973
+ """The number of times this device was unable
974
+ to transmit a frame due to a perceived
975
+ remote busy condition. Busy conditions can
976
+ result from the receipt of an RNR from the
977
+ remote device, the lack of valid sequence
978
+ number space (window saturation), or other
979
+ conditions.""",
980
+ }, # column
981
+ "lapbFlowRejOutPkts" : {
982
+ "nodetype" : "column",
983
+ "moduleName" : "RFC1381-MIB",
984
+ "oid" : "1.3.6.1.2.1.10.16.3.1.6",
985
+ "status" : "current",
986
+ "syntax" : {
987
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
988
+ },
989
+ "access" : "readonly",
990
+ "description" :
991
+ """The number of REJ or SREJ frames sent by
992
+ this station.""",
993
+ }, # column
994
+ "lapbFlowRejInPkts" : {
995
+ "nodetype" : "column",
996
+ "moduleName" : "RFC1381-MIB",
997
+ "oid" : "1.3.6.1.2.1.10.16.3.1.7",
998
+ "status" : "current",
999
+ "syntax" : {
1000
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1001
+ },
1002
+ "access" : "readonly",
1003
+ "description" :
1004
+ """The number of REJ or SREJ frames received
1005
+ by this station.""",
1006
+ }, # column
1007
+ "lapbFlowT1Timeouts" : {
1008
+ "nodetype" : "column",
1009
+ "moduleName" : "RFC1381-MIB",
1010
+ "oid" : "1.3.6.1.2.1.10.16.3.1.8",
1011
+ "status" : "current",
1012
+ "syntax" : {
1013
+ "type" : { "module" :"RFC1155-SMI", "name" : "Counter"},
1014
+ },
1015
+ "access" : "readonly",
1016
+ "description" :
1017
+ """The number of times a re-transmission was
1018
+ effected by the T1 Timer expiring.""",
1019
+ }, # column
1020
+ "lapbFlowFrmrSent" : {
1021
+ "nodetype" : "column",
1022
+ "moduleName" : "RFC1381-MIB",
1023
+ "oid" : "1.3.6.1.2.1.10.16.3.1.9",
1024
+ "status" : "current",
1025
+ "syntax" : {
1026
+ "type" : {
1027
+ "basetype" : "OctetString",
1028
+ "ranges" : [
1029
+ {
1030
+ "min" : "0",
1031
+ "max" : "7"
1032
+ },
1033
+ ],
1034
+ "range" : {
1035
+ "min" : "0",
1036
+ "max" : "7"
1037
+ },
1038
+ },
1039
+ },
1040
+ "access" : "readonly",
1041
+ "description" :
1042
+ """The Information Field of the FRMR most
1043
+ recently sent. If no FRMR has been sent
1044
+ (the normal case) or the information isn't
1045
+ available, this will be an OCTET STRING of
1046
+ zero length.""",
1047
+ "reference" :
1048
+ """ISO 7776 Section 4.3.9, tables 7 and 8""",
1049
+ }, # column
1050
+ "lapbFlowFrmrReceived" : {
1051
+ "nodetype" : "column",
1052
+ "moduleName" : "RFC1381-MIB",
1053
+ "oid" : "1.3.6.1.2.1.10.16.3.1.10",
1054
+ "status" : "current",
1055
+ "syntax" : {
1056
+ "type" : {
1057
+ "basetype" : "OctetString",
1058
+ "ranges" : [
1059
+ {
1060
+ "min" : "0",
1061
+ "max" : "7"
1062
+ },
1063
+ ],
1064
+ "range" : {
1065
+ "min" : "0",
1066
+ "max" : "7"
1067
+ },
1068
+ },
1069
+ },
1070
+ "access" : "readonly",
1071
+ "description" :
1072
+ """The Information Field of the FRMR most
1073
+ recently received. If no FRMR has been
1074
+ received (the normal case) or the
1075
+ information isn't available, this will be an
1076
+ OCTET STRING of zero length.""",
1077
+ "reference" :
1078
+ """ISO 7776 Section 4.3.9, tables 7 and 8""",
1079
+ }, # column
1080
+ "lapbFlowXidReceived" : {
1081
+ "nodetype" : "column",
1082
+ "moduleName" : "RFC1381-MIB",
1083
+ "oid" : "1.3.6.1.2.1.10.16.3.1.11",
1084
+ "status" : "current",
1085
+ "syntax" : {
1086
+ "type" : {
1087
+ "basetype" : "OctetString",
1088
+ "ranges" : [
1089
+ {
1090
+ "min" : "0",
1091
+ "max" : "8206"
1092
+ },
1093
+ ],
1094
+ "range" : {
1095
+ "min" : "0",
1096
+ "max" : "8206"
1097
+ },
1098
+ },
1099
+ },
1100
+ "access" : "readonly",
1101
+ "description" :
1102
+ """The Information Field of the XID frame most
1103
+ recently received. If no XID frame has been
1104
+ received, this will be an OCTET STRING of
1105
+ zero length.""",
1106
+ "reference" :
1107
+ """ISO 8885""",
1108
+ }, # column
1109
+ "lapbXidTable" : {
1110
+ "nodetype" : "table",
1111
+ "moduleName" : "RFC1381-MIB",
1112
+ "oid" : "1.3.6.1.2.1.10.16.4",
1113
+ "status" : "current",
1114
+ "description" :
1115
+ """This table defines values to use for XID
1116
+ negotiation that are not found in the
1117
+ lapbAdmnTable. This table is optional for
1118
+ implementations that don't support XID and
1119
+ mandatory for implementations that do
1120
+ initiate XID negotiation.""",
1121
+ }, # table
1122
+ "lapbXidEntry" : {
1123
+ "nodetype" : "row",
1124
+ "moduleName" : "RFC1381-MIB",
1125
+ "oid" : "1.3.6.1.2.1.10.16.4.1",
1126
+ "status" : "current",
1127
+ "linkage" : [
1128
+ "lapbXidIndex",
1129
+ ],
1130
+ "description" :
1131
+ """XId negotiation parameter values for a
1132
+ specific LAPB.""",
1133
+ }, # row
1134
+ "lapbXidIndex" : {
1135
+ "nodetype" : "column",
1136
+ "moduleName" : "RFC1381-MIB",
1137
+ "oid" : "1.3.6.1.2.1.10.16.4.1.1",
1138
+ "status" : "current",
1139
+ "syntax" : {
1140
+ "type" : { "module" :"RFC1381-MIB", "name" : "IfIndexType"},
1141
+ },
1142
+ "access" : "readonly",
1143
+ "description" :
1144
+ """The ifIndex value for the LAPB interface.""",
1145
+ }, # column
1146
+ "lapbXidAdRIdentifier" : {
1147
+ "nodetype" : "column",
1148
+ "moduleName" : "RFC1381-MIB",
1149
+ "oid" : "1.3.6.1.2.1.10.16.4.1.2",
1150
+ "status" : "current",
1151
+ "syntax" : {
1152
+ "type" : {
1153
+ "basetype" : "OctetString",
1154
+ "ranges" : [
1155
+ {
1156
+ "min" : "0",
1157
+ "max" : "255"
1158
+ },
1159
+ ],
1160
+ "range" : {
1161
+ "min" : "0",
1162
+ "max" : "255"
1163
+ },
1164
+ },
1165
+ },
1166
+ "access" : "readwrite",
1167
+ "default" : "",
1168
+ "description" :
1169
+ """The value of the Address Resolution
1170
+ Identifier. A zero length string indicates
1171
+ no Identifier value has been assigned.""",
1172
+ "reference" :
1173
+ """ISO 8885 Table 2, Name: Identifier""",
1174
+ }, # column
1175
+ "lapbXidAdRAddress" : {
1176
+ "nodetype" : "column",
1177
+ "moduleName" : "RFC1381-MIB",
1178
+ "oid" : "1.3.6.1.2.1.10.16.4.1.3",
1179
+ "status" : "current",
1180
+ "syntax" : {
1181
+ "type" : {
1182
+ "basetype" : "OctetString",
1183
+ "ranges" : [
1184
+ {
1185
+ "min" : "0",
1186
+ "max" : "255"
1187
+ },
1188
+ ],
1189
+ "range" : {
1190
+ "min" : "0",
1191
+ "max" : "255"
1192
+ },
1193
+ },
1194
+ },
1195
+ "access" : "readwrite",
1196
+ "default" : "",
1197
+ "description" :
1198
+ """The value of the Address Resolution
1199
+ Address. A zero length string indicates no
1200
+ Address value has been assigned.""",
1201
+ "reference" :
1202
+ """ISO 8885 Table 2, Name: Address""",
1203
+ }, # column
1204
+ "lapbXidParameterUniqueIdentifier" : {
1205
+ "nodetype" : "column",
1206
+ "moduleName" : "RFC1381-MIB",
1207
+ "oid" : "1.3.6.1.2.1.10.16.4.1.4",
1208
+ "status" : "current",
1209
+ "syntax" : {
1210
+ "type" : {
1211
+ "basetype" : "OctetString",
1212
+ "ranges" : [
1213
+ {
1214
+ "min" : "0",
1215
+ "max" : "255"
1216
+ },
1217
+ ],
1218
+ "range" : {
1219
+ "min" : "0",
1220
+ "max" : "255"
1221
+ },
1222
+ },
1223
+ },
1224
+ "access" : "readwrite",
1225
+ "default" : "",
1226
+ "description" :
1227
+ """The value of the parameter unique
1228
+ Identifier. A zero length string indicates
1229
+ no Unique identifier value has been
1230
+ assigned.""",
1231
+ "reference" :
1232
+ """ISO 8885 Table 3, Name: Identifier""",
1233
+ }, # column
1234
+ "lapbXidGroupAddress" : {
1235
+ "nodetype" : "column",
1236
+ "moduleName" : "RFC1381-MIB",
1237
+ "oid" : "1.3.6.1.2.1.10.16.4.1.5",
1238
+ "status" : "current",
1239
+ "syntax" : {
1240
+ "type" : {
1241
+ "basetype" : "OctetString",
1242
+ "ranges" : [
1243
+ {
1244
+ "min" : "0",
1245
+ "max" : "255"
1246
+ },
1247
+ ],
1248
+ "range" : {
1249
+ "min" : "0",
1250
+ "max" : "255"
1251
+ },
1252
+ },
1253
+ },
1254
+ "access" : "readwrite",
1255
+ "default" : "",
1256
+ "description" :
1257
+ """The value of the parameter Group address.
1258
+ A zero length string indicates no Group
1259
+ address value has been assigned.""",
1260
+ "reference" :
1261
+ """ISO 8885 Table 3, Name: Group address""",
1262
+ }, # column
1263
+ "lapbXidPortNumber" : {
1264
+ "nodetype" : "column",
1265
+ "moduleName" : "RFC1381-MIB",
1266
+ "oid" : "1.3.6.1.2.1.10.16.4.1.6",
1267
+ "status" : "current",
1268
+ "syntax" : {
1269
+ "type" : {
1270
+ "basetype" : "OctetString",
1271
+ "ranges" : [
1272
+ {
1273
+ "min" : "0",
1274
+ "max" : "255"
1275
+ },
1276
+ ],
1277
+ "range" : {
1278
+ "min" : "0",
1279
+ "max" : "255"
1280
+ },
1281
+ },
1282
+ },
1283
+ "access" : "readwrite",
1284
+ "default" : "",
1285
+ "description" :
1286
+ """The port number assigned for this link. A
1287
+ zero length string indicates no local port
1288
+ number identifier has been assigned.""",
1289
+ "reference" :
1290
+ """ISO 8885 Table 3, Name: Port number""",
1291
+ }, # column
1292
+ "lapbXidUserDataSubfield" : {
1293
+ "nodetype" : "column",
1294
+ "moduleName" : "RFC1381-MIB",
1295
+ "oid" : "1.3.6.1.2.1.10.16.4.1.7",
1296
+ "status" : "current",
1297
+ "syntax" : {
1298
+ "type" : {
1299
+ "basetype" : "OctetString",
1300
+ "ranges" : [
1301
+ {
1302
+ "min" : "0",
1303
+ "max" : "8206"
1304
+ },
1305
+ ],
1306
+ "range" : {
1307
+ "min" : "0",
1308
+ "max" : "8206"
1309
+ },
1310
+ },
1311
+ },
1312
+ "access" : "readwrite",
1313
+ "default" : "",
1314
+ "description" :
1315
+ """A user data subfield, if any, to be
1316
+ transmitted in an XID frame. A zero length
1317
+ frame indicates no user data subfield has
1318
+ been assigned. The octet string should
1319
+ include both the User data identifier and
1320
+ User data field as shown in Figures 1 and
1321
+ 4.""",
1322
+ "reference" :
1323
+ """ISO 8885 section 4.3""",
1324
+ }, # column
1325
+ "lapbProtocolVersion" : {
1326
+ "nodetype" : "node",
1327
+ "moduleName" : "RFC1381-MIB",
1328
+ "oid" : "1.3.6.1.2.1.10.16.5",
1329
+ }, # node
1330
+ "lapbProtocolIso7776v1986" : {
1331
+ "nodetype" : "node",
1332
+ "moduleName" : "RFC1381-MIB",
1333
+ "oid" : "1.3.6.1.2.1.10.16.5.1",
1334
+ }, # node
1335
+ "lapbProtocolCcittV1980" : {
1336
+ "nodetype" : "node",
1337
+ "moduleName" : "RFC1381-MIB",
1338
+ "oid" : "1.3.6.1.2.1.10.16.5.2",
1339
+ }, # node
1340
+ "lapbProtocolCcittV1984" : {
1341
+ "nodetype" : "node",
1342
+ "moduleName" : "RFC1381-MIB",
1343
+ "oid" : "1.3.6.1.2.1.10.16.5.3",
1344
+ }, # node
1345
+ }, # nodes
1346
+
1347
+ }