logstash-input-snmp 0.1.0.beta4 → 0.1.0.beta5

Sign up to get free protection for your applications and to get access to all the features.
Files changed (309) hide show
  1. checksums.yaml +4 -4
  2. data/CHANGELOG.md +5 -0
  3. data/lib/logstash/inputs/snmp.rb +75 -12
  4. data/lib/logstash/inputs/snmp/base_client.rb +162 -0
  5. data/lib/logstash/inputs/snmp/client.rb +11 -109
  6. data/lib/logstash/inputs/snmp/clientv3.rb +139 -0
  7. data/lib/logstash/inputs/snmp/mib.rb +22 -20
  8. data/lib/mibs/ietf/ACCOUNTING-CONTROL-MIB.dic +1316 -0
  9. data/lib/mibs/ietf/ADSL-LINE-EXT-MIB.dic +1724 -0
  10. data/lib/mibs/ietf/ADSL-LINE-MIB.dic +7297 -0
  11. data/lib/mibs/ietf/ADSL-TC-MIB.dic +160 -0
  12. data/lib/mibs/ietf/ADSL2-LINE-MIB.dic +8663 -0
  13. data/lib/mibs/ietf/ADSL2-LINE-TC-MIB.dic +1462 -0
  14. data/lib/mibs/ietf/AGENTX-MIB.dic +817 -0
  15. data/lib/mibs/ietf/AGGREGATE-MIB.dic +708 -0
  16. data/lib/mibs/ietf/ALARM-MIB.dic +1734 -0
  17. data/lib/mibs/ietf/APM-MIB.dic +2870 -0
  18. data/lib/mibs/ietf/APPC-MIB.dic +8687 -0
  19. data/lib/mibs/ietf/APPLETALK-MIB.dic +4399 -0
  20. data/lib/mibs/ietf/APPLICATION-MIB.dic +3750 -0
  21. data/lib/mibs/ietf/APPN-DLUR-MIB.dic +972 -0
  22. data/lib/mibs/ietf/APPN-MIB.dic +9364 -0
  23. data/lib/mibs/ietf/APPN-TRAP-MIB.dic +664 -0
  24. data/lib/mibs/ietf/APS-MIB.dic +2430 -0
  25. data/lib/mibs/ietf/ARC-MIB.dic +552 -0
  26. data/lib/mibs/ietf/ATM-ACCOUNTING-INFORMATION-MIB.dic +816 -0
  27. data/lib/mibs/ietf/ATM-MIB.dic +4104 -0
  28. data/lib/mibs/ietf/ATM-TC-MIB.dic +914 -0
  29. data/lib/mibs/ietf/ATM2-MIB.dic +4715 -0
  30. data/lib/mibs/ietf/BFD-STD-MIB.dic +2367 -0
  31. data/lib/mibs/ietf/BFD-TC-STD-MIB.dic +202 -0
  32. data/lib/mibs/ietf/BGP4-MIB.dic +1931 -0
  33. data/lib/mibs/ietf/BLDG-HVAC-MIB.dic +812 -0
  34. data/lib/mibs/ietf/BRIDGE-MIB.dic +2257 -0
  35. data/lib/mibs/ietf/CAPWAP-BASE-MIB.dic +4128 -0
  36. data/lib/mibs/ietf/CAPWAP-DOT11-MIB.dic +482 -0
  37. data/lib/mibs/ietf/CHARACTER-MIB.dic +1140 -0
  38. data/lib/mibs/ietf/CIRCUIT-IF-MIB.dic +493 -0
  39. data/lib/mibs/ietf/CLNS-MIB.dic +1702 -0
  40. data/lib/mibs/ietf/COFFEE-POT-MIB.dic +282 -0
  41. data/lib/mibs/ietf/COPS-CLIENT-MIB.dic +1270 -0
  42. data/lib/mibs/ietf/DECNET-PHIV-MIB.dic +5837 -0
  43. data/lib/mibs/ietf/DIAL-CONTROL-MIB.dic +2139 -0
  44. data/lib/mibs/ietf/DIFFSERV-CONFIG-MIB.dic +378 -0
  45. data/lib/mibs/ietf/DIFFSERV-MIB.dic +5073 -0
  46. data/lib/mibs/ietf/DIRECTORY-SERVER-MIB.dic +1041 -0
  47. data/lib/mibs/ietf/DISMAN-EVENT-MIB.dic +3151 -0
  48. data/lib/mibs/ietf/DISMAN-EXPRESSION-MIB.dic +1716 -0
  49. data/lib/mibs/ietf/DISMAN-NSLOOKUP-MIB.dic +698 -0
  50. data/lib/mibs/ietf/DISMAN-PING-MIB.dic +2635 -0
  51. data/lib/mibs/ietf/DISMAN-SCHEDULE-MIB.dic +1744 -0
  52. data/lib/mibs/ietf/DISMAN-SCRIPT-MIB.dic +2820 -0
  53. data/lib/mibs/ietf/DISMAN-TRACEROUTE-MIB.dic +3239 -0
  54. data/lib/mibs/ietf/DLSW-MIB.dic +5635 -0
  55. data/lib/mibs/ietf/DNS-RESOLVER-MIB.dic +1765 -0
  56. data/lib/mibs/ietf/DNS-SERVER-MIB.dic +1593 -0
  57. data/lib/mibs/ietf/DOCS-BPI-MIB.dic +2634 -0
  58. data/lib/mibs/ietf/DOCS-CABLE-DEVICE-MIB.dic +5042 -0
  59. data/lib/mibs/ietf/DOCS-IETF-BPI2-MIB.dic +5478 -0
  60. data/lib/mibs/ietf/DOCS-IETF-CABLE-DEVICE-NOTIFICATION-MIB.dic +2447 -0
  61. data/lib/mibs/ietf/DOCS-IETF-QOS-MIB.dic +4886 -0
  62. data/lib/mibs/ietf/DOCS-IETF-SUBMGT-MIB.dic +1331 -0
  63. data/lib/mibs/ietf/DOCS-IF-MIB.dic +7980 -0
  64. data/lib/mibs/ietf/DOT12-IF-MIB.dic +1066 -0
  65. data/lib/mibs/ietf/DOT12-RPTR-MIB.dic +2669 -0
  66. data/lib/mibs/ietf/DOT3-EPON-MIB.dic +3297 -0
  67. data/lib/mibs/ietf/DOT3-OAM-MIB.dic +2830 -0
  68. data/lib/mibs/ietf/DS0-MIB.dic +466 -0
  69. data/lib/mibs/ietf/DS0BUNDLE-MIB.dic +468 -0
  70. data/lib/mibs/ietf/DS1-MIB.dic +4890 -0
  71. data/lib/mibs/ietf/DS3-MIB.dic +2719 -0
  72. data/lib/mibs/ietf/DSA-MIB.dic +888 -0
  73. data/lib/mibs/ietf/DSMON-MIB.dic +6177 -0
  74. data/lib/mibs/ietf/DVB-RCS-MIB.dic +5764 -0
  75. data/lib/mibs/ietf/EBN-MIB.dic +1026 -0
  76. data/lib/mibs/ietf/EFM-CU-MIB.dic +4335 -0
  77. data/lib/mibs/ietf/ENTITY-MIB.dic +2235 -0
  78. data/lib/mibs/ietf/ENTITY-SENSOR-MIB.dic +653 -0
  79. data/lib/mibs/ietf/ENTITY-STATE-MIB.dic +457 -0
  80. data/lib/mibs/ietf/ENTITY-STATE-TC-MIB.dic +260 -0
  81. data/lib/mibs/ietf/ETHER-CHIPSET-MIB.dic +787 -0
  82. data/lib/mibs/ietf/EtherLike-MIB.dic +2548 -0
  83. data/lib/mibs/ietf/FC-MGMT-MIB.dic +3465 -0
  84. data/lib/mibs/ietf/FCIP-MGMT-MIB.dic +1596 -0
  85. data/lib/mibs/ietf/FDDI-SMT73-MIB.dic +3378 -0
  86. data/lib/mibs/ietf/FIBRE-CHANNEL-FE-MIB.dic +2504 -0
  87. data/lib/mibs/ietf/FLOAT-TC-MIB.dic +128 -0
  88. data/lib/mibs/ietf/FLOW-METER-MIB.dic +3201 -0
  89. data/lib/mibs/ietf/FORCES-MIB.dic +598 -0
  90. data/lib/mibs/ietf/FR-ATM-PVC-SERVICE-IWF-MIB.dic +1601 -0
  91. data/lib/mibs/ietf/FR-MFR-MIB.dic +1351 -0
  92. data/lib/mibs/ietf/FRAME-RELAY-DTE-MIB.dic +1688 -0
  93. data/lib/mibs/ietf/FRNETSERV-MIB.dic +3940 -0
  94. data/lib/mibs/ietf/FRSLD-MIB.dic +2580 -0
  95. data/lib/mibs/ietf/Finisher-MIB.dic +1416 -0
  96. data/lib/mibs/ietf/GMPLS-LABEL-STD-MIB.dic +965 -0
  97. data/lib/mibs/ietf/GMPLS-LSR-STD-MIB.dic +693 -0
  98. data/lib/mibs/ietf/GMPLS-TC-STD-MIB.dic +180 -0
  99. data/lib/mibs/ietf/GMPLS-TE-STD-MIB.dic +2542 -0
  100. data/lib/mibs/ietf/GSMP-MIB.dic +2468 -0
  101. data/lib/mibs/ietf/HC-ALARM-MIB.dic +1050 -0
  102. data/lib/mibs/ietf/HC-PerfHist-TC-MIB.dic +310 -0
  103. data/lib/mibs/ietf/HC-RMON-MIB.dic +4456 -0
  104. data/lib/mibs/ietf/HDSL2-SHDSL-LINE-MIB.dic +3955 -0
  105. data/lib/mibs/ietf/HOST-RESOURCES-MIB.dic +2453 -0
  106. data/lib/mibs/ietf/HPR-IP-MIB.dic +640 -0
  107. data/lib/mibs/ietf/HPR-MIB.dic +1959 -0
  108. data/lib/mibs/ietf/IANA-ITU-ALARM-TC-MIB.dic +936 -0
  109. data/lib/mibs/ietf/IF-CAP-STACK-MIB.dic +356 -0
  110. data/lib/mibs/ietf/IF-INVERTED-STACK-MIB.dic +220 -0
  111. data/lib/mibs/ietf/IF-MIB.dic +2753 -0
  112. data/lib/mibs/ietf/IFCP-MGMT-MIB.dic +1717 -0
  113. data/lib/mibs/ietf/IGMP-STD-MIB.dic +809 -0
  114. data/lib/mibs/ietf/INET-ADDRESS-MIB.dic +570 -0
  115. data/lib/mibs/ietf/INTEGRATED-SERVICES-GUARANTEED-MIB.dic +319 -0
  116. data/lib/mibs/ietf/INTEGRATED-SERVICES-MIB.dic +1196 -0
  117. data/lib/mibs/ietf/INTERFACETOPN-MIB.dic +1705 -0
  118. data/lib/mibs/ietf/IP-FORWARD-MIB.dic +1853 -0
  119. data/lib/mibs/ietf/IP-MIB.dic +7064 -0
  120. data/lib/mibs/ietf/IPATM-IPMC-MIB.dic +4830 -0
  121. data/lib/mibs/ietf/IPFIX-MIB.dic +2334 -0
  122. data/lib/mibs/ietf/IPFIX-SELECTOR-MIB.dic +215 -0
  123. data/lib/mibs/ietf/IPMCAST-MIB.dic +3390 -0
  124. data/lib/mibs/ietf/IPMROUTE-STD-MIB.dic +1246 -0
  125. data/lib/mibs/ietf/IPOA-MIB.dic +2372 -0
  126. data/lib/mibs/ietf/IPS-AUTH-MIB.dic +1609 -0
  127. data/lib/mibs/ietf/IPSEC-SPD-MIB.dic +3989 -0
  128. data/lib/mibs/ietf/IPV6-FLOW-LABEL-MIB.dic +110 -0
  129. data/lib/mibs/ietf/IPV6-ICMP-MIB.dic +748 -0
  130. data/lib/mibs/ietf/IPV6-MIB.dic +2028 -0
  131. data/lib/mibs/ietf/IPV6-MLD-MIB.dic +659 -0
  132. data/lib/mibs/ietf/IPV6-TCP-MIB.dic +332 -0
  133. data/lib/mibs/ietf/IPV6-UDP-MIB.dic +209 -0
  134. data/lib/mibs/ietf/ISCSI-MIB.dic +4613 -0
  135. data/lib/mibs/ietf/ISDN-MIB.dic +1796 -0
  136. data/lib/mibs/ietf/ISIS-MIB.dic +6215 -0
  137. data/lib/mibs/ietf/ISNS-MIB.dic +6578 -0
  138. data/lib/mibs/ietf/ITU-ALARM-MIB.dic +665 -0
  139. data/lib/mibs/ietf/ITU-ALARM-TC-MIB.dic +137 -0
  140. data/lib/mibs/ietf/Job-Monitoring-MIB.dic +2519 -0
  141. data/lib/mibs/ietf/L2TP-MIB.dic +4050 -0
  142. data/lib/mibs/ietf/LANGTAG-TC-MIB.dic +104 -0
  143. data/lib/mibs/ietf/LISP-MIB.dic +4067 -0
  144. data/lib/mibs/ietf/LMP-MIB.dic +5166 -0
  145. data/lib/mibs/ietf/MALLOC-MIB.dic +2156 -0
  146. data/lib/mibs/ietf/MAU-MIB.dic +2619 -0
  147. data/lib/mibs/ietf/MIDCOM-MIB.dic +2856 -0
  148. data/lib/mibs/ietf/MIOX25-MIB.dic +828 -0
  149. data/lib/mibs/ietf/MIP-MIB.dic +3473 -0
  150. data/lib/mibs/ietf/MOBILEIPV6-MIB.dic +5228 -0
  151. data/lib/mibs/ietf/MPLS-FTN-STD-MIB.dic +1594 -0
  152. data/lib/mibs/ietf/MPLS-L3VPN-STD-MIB.dic +2548 -0
  153. data/lib/mibs/ietf/MPLS-LC-ATM-STD-MIB.dic +491 -0
  154. data/lib/mibs/ietf/MPLS-LC-FR-STD-MIB.dic +395 -0
  155. data/lib/mibs/ietf/MPLS-LDP-ATM-STD-MIB.dic +1019 -0
  156. data/lib/mibs/ietf/MPLS-LDP-FRAME-RELAY-STD-MIB.dic +862 -0
  157. data/lib/mibs/ietf/MPLS-LDP-GENERIC-STD-MIB.dic +445 -0
  158. data/lib/mibs/ietf/MPLS-LDP-STD-MIB.dic +3657 -0
  159. data/lib/mibs/ietf/MPLS-LSR-STD-MIB.dic +3103 -0
  160. data/lib/mibs/ietf/MPLS-TC-STD-MIB.dic +911 -0
  161. data/lib/mibs/ietf/MPLS-TE-STD-MIB.dic +3673 -0
  162. data/lib/mibs/ietf/MSDP-MIB.dic +1893 -0
  163. data/lib/mibs/ietf/MTA-MIB.dic +1898 -0
  164. data/lib/mibs/ietf/Modem-MIB.dic +2054 -0
  165. data/lib/mibs/ietf/NAT-MIB.dic +3866 -0
  166. data/lib/mibs/ietf/NETWORK-SERVICES-MIB.dic +1034 -0
  167. data/lib/mibs/ietf/NHDP-MIB.dic +3005 -0
  168. data/lib/mibs/ietf/NHRP-MIB.dic +3660 -0
  169. data/lib/mibs/ietf/NOTIFICATION-LOG-MIB.dic +1156 -0
  170. data/lib/mibs/ietf/NTPv4-MIB.dic +1535 -0
  171. data/lib/mibs/ietf/OPT-IF-MIB.dic +8972 -0
  172. data/lib/mibs/ietf/OSPF-MIB.dic +5963 -0
  173. data/lib/mibs/ietf/OSPF-TRAP-MIB.dic +1190 -0
  174. data/lib/mibs/ietf/OSPFV3-MIB.dic +5708 -0
  175. data/lib/mibs/ietf/P-BRIDGE-MIB.dic +1499 -0
  176. data/lib/mibs/ietf/PARALLEL-MIB.dic +476 -0
  177. data/lib/mibs/ietf/PIM-MIB.dic +1393 -0
  178. data/lib/mibs/ietf/PIM-STD-MIB.dic +6819 -0
  179. data/lib/mibs/ietf/PINT-MIB.dic +830 -0
  180. data/lib/mibs/ietf/PKTC-IETF-MTA-MIB.dic +3191 -0
  181. data/lib/mibs/ietf/PKTC-IETF-SIG-MIB.dic +4713 -0
  182. data/lib/mibs/ietf/PMIPV6-MIB.dic +3010 -0
  183. data/lib/mibs/ietf/PMIPV6-TC-MIB.dic +293 -0
  184. data/lib/mibs/ietf/POLICY-BASED-MANAGEMENT-MIB.dic +3316 -0
  185. data/lib/mibs/ietf/POWER-ETHERNET-MIB.dic +959 -0
  186. data/lib/mibs/ietf/PPP-BRIDGE-NCP-MIB.dic +587 -0
  187. data/lib/mibs/ietf/PPP-IP-NCP-MIB.dic +269 -0
  188. data/lib/mibs/ietf/PPP-LCP-MIB.dic +994 -0
  189. data/lib/mibs/ietf/PPP-SEC-MIB.dic +411 -0
  190. data/lib/mibs/ietf/PSAMP-MIB.dic +998 -0
  191. data/lib/mibs/ietf/PTOPO-MIB.dic +1135 -0
  192. data/lib/mibs/ietf/PW-ATM-MIB.dic +1642 -0
  193. data/lib/mibs/ietf/PW-CEP-STD-MIB.dic +3661 -0
  194. data/lib/mibs/ietf/PW-STD-MIB.dic +3592 -0
  195. data/lib/mibs/ietf/PW-TC-STD-MIB.dic +437 -0
  196. data/lib/mibs/ietf/PW-TDM-MIB.dic +1896 -0
  197. data/lib/mibs/ietf/PerfHist-TC-MIB.dic +152 -0
  198. data/lib/mibs/ietf/Printer-MIB.dic +6665 -0
  199. data/lib/mibs/ietf/Q-BRIDGE-MIB.dic +3115 -0
  200. data/lib/mibs/ietf/RADIUS-ACC-CLIENT-MIB.dic +991 -0
  201. data/lib/mibs/ietf/RADIUS-ACC-SERVER-MIB.dic +1183 -0
  202. data/lib/mibs/ietf/RADIUS-AUTH-CLIENT-MIB.dic +1073 -0
  203. data/lib/mibs/ietf/RADIUS-AUTH-SERVER-MIB.dic +1251 -0
  204. data/lib/mibs/ietf/RADIUS-DYNAUTH-CLIENT-MIB.dic +1116 -0
  205. data/lib/mibs/ietf/RADIUS-DYNAUTH-SERVER-MIB.dic +1003 -0
  206. data/lib/mibs/ietf/RAQMON-MIB.dic +2695 -0
  207. data/lib/mibs/ietf/RBRIDGE-MIB.dic +2981 -0
  208. data/lib/mibs/ietf/RDBMS-MIB.dic +1935 -0
  209. data/lib/mibs/ietf/RFC1065-SMI.dic +108 -0
  210. data/lib/mibs/ietf/RFC1155-SMI.dic +118 -0
  211. data/lib/mibs/ietf/RFC1158-MIB.dic +2440 -0
  212. data/lib/mibs/ietf/RFC1213-MIB.dic +3434 -0
  213. data/lib/mibs/ietf/RFC1269-MIB.dic +557 -0
  214. data/lib/mibs/ietf/RFC1271-MIB.dic +4135 -0
  215. data/lib/mibs/ietf/RFC1285-MIB.dic +2842 -0
  216. data/lib/mibs/ietf/RFC1316-MIB.dic +800 -0
  217. data/lib/mibs/ietf/RFC1381-MIB.dic +1347 -0
  218. data/lib/mibs/ietf/RFC1382-MIB.dic +3820 -0
  219. data/lib/mibs/ietf/RFC1414-MIB.dic +214 -0
  220. data/lib/mibs/ietf/RIPv2-MIB.dic +773 -0
  221. data/lib/mibs/ietf/RMON-MIB.dic +5551 -0
  222. data/lib/mibs/ietf/RMON2-MIB.dic +8224 -0
  223. data/lib/mibs/ietf/ROHC-MIB.dic +1613 -0
  224. data/lib/mibs/ietf/ROHC-RTP-MIB.dic +859 -0
  225. data/lib/mibs/ietf/ROHC-UNCOMPRESSED-MIB.dic +267 -0
  226. data/lib/mibs/ietf/RPKI-ROUTER-MIB.dic +1363 -0
  227. data/lib/mibs/ietf/RS-232-MIB.dic +1335 -0
  228. data/lib/mibs/ietf/RSERPOOL-MIB.dic +2501 -0
  229. data/lib/mibs/ietf/RSTP-MIB.dic +427 -0
  230. data/lib/mibs/ietf/RSVP-MIB.dic +4135 -0
  231. data/lib/mibs/ietf/RTP-MIB.dic +1376 -0
  232. data/lib/mibs/ietf/SCSI-MIB.dic +3804 -0
  233. data/lib/mibs/ietf/SCTP-MIB.dic +1924 -0
  234. data/lib/mibs/ietf/SFLOW-MIB.dic +568 -0
  235. data/lib/mibs/ietf/SIP-COMMON-MIB.dic +2769 -0
  236. data/lib/mibs/ietf/SIP-MIB.dic +1438 -0
  237. data/lib/mibs/ietf/SIP-SERVER-MIB.dic +1150 -0
  238. data/lib/mibs/ietf/SIP-TC-MIB.dic +257 -0
  239. data/lib/mibs/ietf/SIP-UA-MIB.dic +268 -0
  240. data/lib/mibs/ietf/SLAPM-MIB.dic +4527 -0
  241. data/lib/mibs/ietf/SMON-MIB.dic +1758 -0
  242. data/lib/mibs/ietf/SNA-NAU-MIB.dic +4042 -0
  243. data/lib/mibs/ietf/SNA-SDLC-MIB.dic +3858 -0
  244. data/lib/mibs/ietf/SNMP-COMMUNITY-MIB.dic +715 -0
  245. data/lib/mibs/ietf/SNMP-FRAMEWORK-MIB.dic +709 -0
  246. data/lib/mibs/ietf/SNMP-MPD-MIB.dic +230 -0
  247. data/lib/mibs/ietf/SNMP-NOTIFICATION-MIB.dic +859 -0
  248. data/lib/mibs/ietf/SNMP-PROXY-MIB.dic +414 -0
  249. data/lib/mibs/ietf/SNMP-REPEATER-MIB.dic +4335 -0
  250. data/lib/mibs/ietf/SNMP-SSH-TM-MIB.dic +447 -0
  251. data/lib/mibs/ietf/SNMP-TARGET-MIB.dic +924 -0
  252. data/lib/mibs/ietf/SNMP-TLS-TM-MIB.dic +1449 -0
  253. data/lib/mibs/ietf/SNMP-TSM-MIB.dic +315 -0
  254. data/lib/mibs/ietf/SNMP-USER-BASED-SM-MIB.dic +1164 -0
  255. data/lib/mibs/ietf/SNMP-USM-AES-MIB.dic +95 -0
  256. data/lib/mibs/ietf/SNMP-USM-DH-OBJECTS-MIB.dic +653 -0
  257. data/lib/mibs/ietf/SNMP-VIEW-BASED-ACM-MIB.dic +1202 -0
  258. data/lib/mibs/ietf/SNMPv2-MIB.dic +1382 -0
  259. data/lib/mibs/ietf/SNMPv2-SMI.dic +223 -0
  260. data/lib/mibs/ietf/SNMPv2-USEC-MIB.dic +405 -0
  261. data/lib/mibs/ietf/SONET-MIB.dic +3308 -0
  262. data/lib/mibs/ietf/SOURCE-ROUTING-MIB.dic +542 -0
  263. data/lib/mibs/ietf/SSPM-MIB.dic +1530 -0
  264. data/lib/mibs/ietf/SYSAPPL-MIB.dic +2092 -0
  265. data/lib/mibs/ietf/T11-FC-FABRIC-ADDR-MGR-MIB.dic +1779 -0
  266. data/lib/mibs/ietf/T11-FC-FABRIC-CONFIG-SERVER-MIB.dic +2822 -0
  267. data/lib/mibs/ietf/T11-FC-FABRIC-LOCK-MIB.dic +700 -0
  268. data/lib/mibs/ietf/T11-FC-FSPF-MIB.dic +1889 -0
  269. data/lib/mibs/ietf/T11-FC-NAME-SERVER-MIB.dic +1775 -0
  270. data/lib/mibs/ietf/T11-FC-ROUTE-MIB.dic +655 -0
  271. data/lib/mibs/ietf/T11-FC-RSCN-MIB.dic +1110 -0
  272. data/lib/mibs/ietf/T11-FC-VIRTUAL-FABRIC-MIB.dic +770 -0
  273. data/lib/mibs/ietf/T11-FC-ZONE-SERVER-MIB.dic +3886 -0
  274. data/lib/mibs/ietf/T11-TC-MIB.dic +110 -0
  275. data/lib/mibs/ietf/TCP-ESTATS-MIB.dic +3926 -0
  276. data/lib/mibs/ietf/TCP-MIB.dic +1319 -0
  277. data/lib/mibs/ietf/TCPIPX-MIB.dic +457 -0
  278. data/lib/mibs/ietf/TE-LINK-STD-MIB.dic +2876 -0
  279. data/lib/mibs/ietf/TE-MIB.dic +2924 -0
  280. data/lib/mibs/ietf/TED-MIB.dic +1749 -0
  281. data/lib/mibs/ietf/TIME-AGGREGATE-MIB.dic +550 -0
  282. data/lib/mibs/ietf/TN3270E-MIB.dic +2785 -0
  283. data/lib/mibs/ietf/TN3270E-RT-MIB.dic +1317 -0
  284. data/lib/mibs/ietf/TOKEN-RING-RMON-MIB.dic +2820 -0
  285. data/lib/mibs/ietf/TOKENRING-MIB.dic +1184 -0
  286. data/lib/mibs/ietf/TOKENRING-STATION-SR-MIB.dic +292 -0
  287. data/lib/mibs/ietf/TRANSPORT-ADDRESS-MIB.dic +610 -0
  288. data/lib/mibs/ietf/TRIP-MIB.dic +3159 -0
  289. data/lib/mibs/ietf/TRIP-TC-MIB.dic +241 -0
  290. data/lib/mibs/ietf/TUNNEL-MIB.dic +1095 -0
  291. data/lib/mibs/ietf/UDP-MIB.dic +751 -0
  292. data/lib/mibs/ietf/UDPLITE-MIB.dic +704 -0
  293. data/lib/mibs/ietf/UPS-MIB.dic +3088 -0
  294. data/lib/mibs/ietf/URI-TC-MIB.dic +193 -0
  295. data/lib/mibs/ietf/UUID-TC-MIB.dic +135 -0
  296. data/lib/mibs/ietf/VDSL-LINE-EXT-MCM-MIB.dic +989 -0
  297. data/lib/mibs/ietf/VDSL-LINE-EXT-SCM-MIB.dic +605 -0
  298. data/lib/mibs/ietf/VDSL-LINE-MIB.dic +4518 -0
  299. data/lib/mibs/ietf/VDSL2-LINE-MIB.dic +11029 -0
  300. data/lib/mibs/ietf/VDSL2-LINE-TC-MIB.dic +3152 -0
  301. data/lib/mibs/ietf/VPN-TC-STD-MIB.dic +121 -0
  302. data/lib/mibs/ietf/VRRP-MIB.dic +1163 -0
  303. data/lib/mibs/ietf/VRRPV3-MIB.dic +1403 -0
  304. data/lib/mibs/ietf/WWW-MIB.dic +1810 -0
  305. data/lib/mibs/logstash/iso.dic +18 -0
  306. data/logstash-input-snmp.gemspec +1 -1
  307. data/spec/inputs/snmp/mib_spec.rb +10 -17
  308. data/spec/inputs/snmp_spec.rb +27 -1
  309. metadata +302 -2
@@ -0,0 +1,4713 @@
1
+ # python version 1.0 DO NOT EDIT
2
+ #
3
+ # This python file has been generated by smidump version 0.5.0:
4
+ #
5
+ # smidump -f python PKTC-IETF-SIG-MIB
6
+
7
+ FILENAME = "./libsmi-0.5.0/mibs/ietf/PKTC-IETF-SIG-MIB"
8
+
9
+ MIB = {
10
+ "moduleName" : "PKTC-IETF-SIG-MIB",
11
+
12
+ "PKTC-IETF-SIG-MIB" : {
13
+ "nodetype" : "module",
14
+ "language" : "SMIv2",
15
+ "organization" :
16
+ """IETF IPCDN Working Group""",
17
+ "contact" :
18
+ """Sumanth Channabasappa
19
+ Cable Television Laboratories, Inc.
20
+ 858 Coal Creek Circle,
21
+ Louisville, CO 80027, USA
22
+ Phone: +1 303-661-3307
23
+ Email: Sumanth@cablelabs.com
24
+
25
+ Gordon Beacham
26
+ Motorola, Inc.
27
+ 6450 Sequence Drive, Bldg. 1
28
+ San Diego, CA 92121, USA
29
+ Phone: +1 858-404-2334
30
+ Email: gordon.beacham@motorola.com
31
+
32
+ Satish Kumar Mudugere Eswaraiah
33
+ Texas Instruments India (P) Ltd.,
34
+ Golf view, Wind Tunnel Road
35
+ Murugesh Palya
36
+ Bangalore 560 017, INDIA
37
+ Phone: +91 80 5269451
38
+ Email: satish.kumar@ti.com
39
+
40
+ IETF IPCDN Working Group
41
+ General Discussion: ipcdn@ietf.org
42
+ Subscribe: http://www.ietf.org/mailman/listinfo/ipcdn
43
+ Archive: ftp://ftp.ietf.org/ietf-mail-archive/ipcdn
44
+ Co-Chair: Jean-Francois Mule, jf.mule@cablelabs.com
45
+ Co-Chair: Richard Woundy, Richard_Woundy@cable.comcast.com""",
46
+ "description" :
47
+ """This MIB module supplies the basic management
48
+ objects for the PacketCable and IPCablecom Signaling
49
+ protocols. This version of the MIB includes
50
+ common signaling and Network Call Signaling
51
+
52
+
53
+
54
+ (NCS)-related signaling objects.
55
+
56
+ Copyright (C) The IETF Trust (2008). This version of
57
+ this MIB module is part of RFC 5098; see the RFC itself for
58
+ full legal notices.""",
59
+ "revisions" : (
60
+ {
61
+ "date" : "2007-12-18 00:00",
62
+ "description" :
63
+ """Initial version, published as RFC 5098.""",
64
+ },
65
+ ),
66
+ "identity node" : "pktcIetfSigMib",
67
+ },
68
+
69
+ "imports" : (
70
+ {"module" : "SNMPv2-SMI", "name" : "MODULE-IDENTITY"},
71
+ {"module" : "SNMPv2-SMI", "name" : "OBJECT-TYPE"},
72
+ {"module" : "SNMPv2-SMI", "name" : "Integer32"},
73
+ {"module" : "SNMPv2-SMI", "name" : "Unsigned32"},
74
+ {"module" : "SNMPv2-SMI", "name" : "mib-2"},
75
+ {"module" : "INET-ADDRESS-MIB", "name" : "InetAddressType"},
76
+ {"module" : "INET-ADDRESS-MIB", "name" : "InetAddress"},
77
+ {"module" : "INET-ADDRESS-MIB", "name" : "InetPortNumber"},
78
+ {"module" : "SNMPv2-TC", "name" : "TEXTUAL-CONVENTION"},
79
+ {"module" : "SNMPv2-TC", "name" : "RowStatus"},
80
+ {"module" : "SNMPv2-TC", "name" : "TruthValue"},
81
+ {"module" : "SNMPv2-CONF", "name" : "OBJECT-GROUP"},
82
+ {"module" : "SNMPv2-CONF", "name" : "MODULE-COMPLIANCE"},
83
+ {"module" : "SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
84
+ {"module" : "IF-MIB", "name" : "ifIndex"},
85
+ {"module" : "DIFFSERV-DSCP-TC", "name" : "Dscp"},
86
+ ),
87
+
88
+ "typedefs" : {
89
+ "TenthdBm" : {
90
+ "basetype" : "Integer32",
91
+ "status" : "current",
92
+ "format" : "d-1",
93
+ "description" :
94
+ """This TEXTUAL-CONVENTION represents power levels that are
95
+ normally expressed in dBm. Units are in tenths of a dBm;
96
+ for example, -13.5 dBm will be represented as -135.""",
97
+ },
98
+ "PktcCodecType" : {
99
+ "basetype" : "Enumeration",
100
+ "status" : "current",
101
+ "other" : {
102
+ "nodetype" : "namednumber",
103
+ "number" : "1"
104
+ },
105
+ "unknown" : {
106
+ "nodetype" : "namednumber",
107
+ "number" : "2"
108
+ },
109
+ "g729" : {
110
+ "nodetype" : "namednumber",
111
+ "number" : "3"
112
+ },
113
+ "reserved" : {
114
+ "nodetype" : "namednumber",
115
+ "number" : "4"
116
+ },
117
+ "g729E" : {
118
+ "nodetype" : "namednumber",
119
+ "number" : "5"
120
+ },
121
+ "pcmu" : {
122
+ "nodetype" : "namednumber",
123
+ "number" : "6"
124
+ },
125
+ "g726at32" : {
126
+ "nodetype" : "namednumber",
127
+ "number" : "7"
128
+ },
129
+ "g728" : {
130
+ "nodetype" : "namednumber",
131
+ "number" : "8"
132
+ },
133
+ "pcma" : {
134
+ "nodetype" : "namednumber",
135
+ "number" : "9"
136
+ },
137
+ "g726at16" : {
138
+ "nodetype" : "namednumber",
139
+ "number" : "10"
140
+ },
141
+ "g726at24" : {
142
+ "nodetype" : "namednumber",
143
+ "number" : "11"
144
+ },
145
+ "g726at40" : {
146
+ "nodetype" : "namednumber",
147
+ "number" : "12"
148
+ },
149
+ "ilbc" : {
150
+ "nodetype" : "namednumber",
151
+ "number" : "13"
152
+ },
153
+ "bv16" : {
154
+ "nodetype" : "namednumber",
155
+ "number" : "14"
156
+ },
157
+ "description" :
158
+ """ This TEXTUAL-CONVENTION defines various types of codecs
159
+ that MAY be supported. The description for each
160
+ enumeration is listed below:
161
+
162
+ Enumeration Description
163
+ other a defined codec not in the enumeration
164
+ unknown a codec not defined by the PacketCable
165
+ Codec Specification
166
+ g729 ITU-T Recommendation G.729
167
+ reserved for future use
168
+ g729E ITU-T Recommendation G.729E
169
+ pcmu Pulse Code Modulation u-law (PCMU)
170
+ g726at32 ITU-T Recommendation G.726-32 (32 kbit/s)
171
+ g728 ITU-T Recommendation G.728
172
+ pcma Pulse Code Modulation a-law (PCMA)
173
+ g726at16 ITU-T Recommendation G.726-16 (16 kbit/s)
174
+ g726at24 ITU-T Recommendation G.726-24 (24 kbit/s)
175
+ g726at40 ITU-T Recommendation G.726-40 (40 kbit/s)
176
+ ilbc IETF Internet low-bit rate codec
177
+ bv16 Broadcom BroadVoice16
178
+
179
+ The list of codecs is consistent with the IETF
180
+ Real-Time Transport Protocol (RTP) Profile registry and
181
+
182
+
183
+
184
+ the RTP Map Parameters Table in PacketCable Audio/Video
185
+ Codecs Specification [PKT-SP-CODEC]. The literal codec
186
+ name for each codec is listed below:
187
+
188
+ Codec Literal Codec Name
189
+ g729 G729
190
+ g729E G729E
191
+ pcmu PCMU
192
+ g726at32 G726-32
193
+ g728 G728
194
+ pcma PCMA
195
+ g726at16 G726-16
196
+ g726at24 G726-24
197
+ g726at40 G726-40
198
+ ilbc iLBC
199
+ bv16 BV16
200
+
201
+ The literal codec name is the second column of the table
202
+ with codec RTP Map Parameters. The Literal Codec Name Column
203
+ contains the codec name used in the local connection
204
+ options (LCO) of the NCS messages create connection
205
+ (CRCX)/modify connection (MDCX) and is also used to
206
+ identify the codec in the Call Management System (CMS)
207
+ Provisioning Specification. The RTP Map Parameter column of
208
+ the Table contains the string used in the media attribute
209
+ line (a=) of the session description protocol (SDP)
210
+ parameters in NCS messages.""",
211
+ },
212
+ "PktcRingCadence" : {
213
+ "basetype" : "OctetString",
214
+ "status" : "current",
215
+ "ranges" : [
216
+ {
217
+ "min" : "4",
218
+ "max" : "36"
219
+ },
220
+ ],
221
+ "range" : {
222
+ "min" : "4",
223
+ "max" : "36"
224
+ },
225
+ "description" :
226
+ """This object provides an encoding scheme for ring
227
+
228
+
229
+
230
+ cadences, including repeatability characteristics. All
231
+ fields in this object MUST be encoded in network-byte
232
+ order.
233
+
234
+ The first three higher-order octets are reserved. The
235
+ octets that follow are used to encode a 'bit-string', with
236
+ each bit corresponding to 50 milliseconds. A bit value of
237
+ '1' indicates the presence of a ring-tone, and a bit value
238
+ of '0' indicates the absence of a ring-tone, for that
239
+ duration (50 ms) (Note: A minimum number of octets
240
+ required to encode the bit-string MUST be used).
241
+
242
+ The first two of the reserved octets MUST indicate the
243
+ length of the encoded cadence (in bits) and MUST range
244
+ between 1 and 264. (Note: The length in bits MUST also be
245
+ consistent with the number of octets that encode the
246
+ cadence). The MTA MUST ignore any unused bits in the last
247
+ octet, but MUST reflect the value as provided on
248
+ subsequent SNMP GETs.
249
+
250
+ The third of the reserved octets indicates 'repeatability'
251
+ and MUST be either 0x80 or 0x00 -- the former value
252
+ indicating 'non-repeatability', and the latter indicating
253
+ 'repeatability'.
254
+
255
+ The MTA MUST reject attempts to set a value that violates
256
+ any of the above requirements.""",
257
+ },
258
+ "PktcSigType" : {
259
+ "basetype" : "Enumeration",
260
+ "status" : "current",
261
+ "other" : {
262
+ "nodetype" : "namednumber",
263
+ "number" : "1"
264
+ },
265
+ "ncs" : {
266
+ "nodetype" : "namednumber",
267
+ "number" : "2"
268
+ },
269
+ "description" :
270
+ """ This object lists the various types of signaling that may
271
+ be supported:
272
+
273
+ other(1) - set when signaling other than NCS is used
274
+ ncs(2) - Network Call Signaling is a derivation of MGCP
275
+ (Media Gateway Control Protocol) defined for
276
+ IPCablecom/PacketCable MTAs.""",
277
+ },
278
+ "DtmfCode" : {
279
+ "basetype" : "Enumeration",
280
+ "status" : "current",
281
+ "dtmfcode0" : {
282
+ "nodetype" : "namednumber",
283
+ "number" : "0"
284
+ },
285
+ "dtmfcode1" : {
286
+ "nodetype" : "namednumber",
287
+ "number" : "1"
288
+ },
289
+ "dtmfcode2" : {
290
+ "nodetype" : "namednumber",
291
+ "number" : "2"
292
+ },
293
+ "dtmfcode3" : {
294
+ "nodetype" : "namednumber",
295
+ "number" : "3"
296
+ },
297
+ "dtmfcode4" : {
298
+ "nodetype" : "namednumber",
299
+ "number" : "4"
300
+ },
301
+ "dtmfcode5" : {
302
+ "nodetype" : "namednumber",
303
+ "number" : "5"
304
+ },
305
+ "dtmfcode6" : {
306
+ "nodetype" : "namednumber",
307
+ "number" : "6"
308
+ },
309
+ "dtmfcode7" : {
310
+ "nodetype" : "namednumber",
311
+ "number" : "7"
312
+ },
313
+ "dtmfcode8" : {
314
+ "nodetype" : "namednumber",
315
+ "number" : "8"
316
+ },
317
+ "dtmfcode9" : {
318
+ "nodetype" : "namednumber",
319
+ "number" : "9"
320
+ },
321
+ "dtmfcodeStar" : {
322
+ "nodetype" : "namednumber",
323
+ "number" : "10"
324
+ },
325
+ "dtmfcodeHash" : {
326
+ "nodetype" : "namednumber",
327
+ "number" : "11"
328
+ },
329
+ "dtmfcodeA" : {
330
+ "nodetype" : "namednumber",
331
+ "number" : "12"
332
+ },
333
+ "dtmfcodeB" : {
334
+ "nodetype" : "namednumber",
335
+ "number" : "13"
336
+ },
337
+ "dtmfcodeC" : {
338
+ "nodetype" : "namednumber",
339
+ "number" : "14"
340
+ },
341
+ "dtmfcodeD" : {
342
+ "nodetype" : "namednumber",
343
+ "number" : "15"
344
+ },
345
+ "description" :
346
+ """This TEXTUAL-CONVENTION represents the Dual-Tone
347
+ Multi-Frequency (DTMF) Character used
348
+ to indicate the start or end of the digit transition
349
+ sequence used for caller id or Visual Message Waiting
350
+ Indicator (VMWI).
351
+
352
+ Note: The DTMF code '*' is indicated using 'dtmfcodeStar',
353
+ and the DTMF code '#' is indicated using ' dtmfcodeHash'.""",
354
+ },
355
+ "PktcSubscriberSideSigProtocol" : {
356
+ "basetype" : "Enumeration",
357
+ "status" : "current",
358
+ "fsk" : {
359
+ "nodetype" : "namednumber",
360
+ "number" : "1"
361
+ },
362
+ "dtmf" : {
363
+ "nodetype" : "namednumber",
364
+ "number" : "2"
365
+ },
366
+ "description" :
367
+ """This TEXTUAL-CONVENTION represents the Signaling
368
+ protocol being used for purposes such as caller id
369
+ or VMWI.
370
+
371
+ A value of fsk(1) indicates Frequency Shift Keying
372
+ (FSK).
373
+ A value of dtmf(2) indicates Dual-Tone Multi-Frequency
374
+ (DTMF).""",
375
+ },
376
+ }, # typedefs
377
+
378
+ "nodes" : {
379
+ "pktcIetfSigMib" : {
380
+ "nodetype" : "node",
381
+ "moduleName" : "PKTC-IETF-SIG-MIB",
382
+ "oid" : "1.3.6.1.2.1.169",
383
+ "status" : "current",
384
+ }, # node
385
+ "pktcSigNotification" : {
386
+ "nodetype" : "node",
387
+ "moduleName" : "PKTC-IETF-SIG-MIB",
388
+ "oid" : "1.3.6.1.2.1.169.0",
389
+ }, # node
390
+ "pktcSigMibObjects" : {
391
+ "nodetype" : "node",
392
+ "moduleName" : "PKTC-IETF-SIG-MIB",
393
+ "oid" : "1.3.6.1.2.1.169.1",
394
+ }, # node
395
+ "pktcSigDevObjects" : {
396
+ "nodetype" : "node",
397
+ "moduleName" : "PKTC-IETF-SIG-MIB",
398
+ "oid" : "1.3.6.1.2.1.169.1.1",
399
+ }, # node
400
+ "pktcSigDevCodecTable" : {
401
+ "nodetype" : "table",
402
+ "moduleName" : "PKTC-IETF-SIG-MIB",
403
+ "oid" : "1.3.6.1.2.1.169.1.1.1",
404
+ "status" : "current",
405
+ "description" :
406
+ """ This table describes the MTA-supported codec types. An MTA
407
+ MUST populate this table with all possible combinations of
408
+ codecs it supports for simultaneous operation. For example,
409
+ an MTA with two endpoints may be designed with a particular
410
+ Digital Signal Processing (DSP) and memory architecture that
411
+ allows it to support the following fixed combinations of
412
+ codecs for simultaneous operation:
413
+
414
+ Codec Type Maximum Number of Simultaneous Codecs
415
+ PCMA 3
416
+
417
+ PCMA 2
418
+ PCMU 1
419
+
420
+ PCMA 1
421
+
422
+ PCMU 2
423
+
424
+ PCMU 3
425
+
426
+ PCMA 1
427
+ G729 1
428
+
429
+ G729 2
430
+
431
+ PCMU 1
432
+ G729 1
433
+
434
+ Based on this example, the entries in the codec table
435
+ would be:
436
+
437
+ pktcSigDev pktcSigDev pktcSigDev
438
+ CodecComboIndex CodecType CodecMax
439
+ 1 pcma 3
440
+ 2 pcma 2
441
+ 2 pcmu 1
442
+
443
+
444
+
445
+ 3 pcma 1
446
+ 3 pcmu 2
447
+ 4 pcmu 3
448
+ 5 pcma 1
449
+ 5 g729 1
450
+ 6 g729 2
451
+ 7 pcmu 1
452
+ 7 g729 1
453
+
454
+ An operator querying this table is able to determine all
455
+ possible codec combinations the MTA is capable of
456
+ simultaneously supporting.
457
+
458
+ This table MUST NOT include non-voice codecs.""",
459
+ }, # table
460
+ "pktcSigDevCodecEntry" : {
461
+ "nodetype" : "row",
462
+ "moduleName" : "PKTC-IETF-SIG-MIB",
463
+ "oid" : "1.3.6.1.2.1.169.1.1.1.1",
464
+ "status" : "current",
465
+ "linkage" : [
466
+ "pktcSigDevCodecComboIndex",
467
+ "pktcSigDevCodecType",
468
+ ],
469
+ "description" :
470
+ """Each entry represents the maximum number of active
471
+ connections with a particular codec the MTA is capable of
472
+ supporting. Each row is indexed by a composite key
473
+ consisting of a number enumerating the particular codec
474
+ combination and the codec type.""",
475
+ }, # row
476
+ "pktcSigDevCodecComboIndex" : {
477
+ "nodetype" : "column",
478
+ "moduleName" : "PKTC-IETF-SIG-MIB",
479
+ "oid" : "1.3.6.1.2.1.169.1.1.1.1.1",
480
+ "status" : "current",
481
+ "syntax" : {
482
+ "type" : {
483
+ "basetype" : "Unsigned32",
484
+ "ranges" : [
485
+ {
486
+ "min" : "1",
487
+ "max" : "255"
488
+ },
489
+ ],
490
+ "range" : {
491
+ "min" : "1",
492
+ "max" : "255"
493
+ },
494
+ },
495
+ },
496
+ "access" : "noaccess",
497
+ "description" :
498
+ """ The index value that enumerates a particular codec
499
+ combination in the pktcSigDevCodecTable.""",
500
+ }, # column
501
+ "pktcSigDevCodecType" : {
502
+ "nodetype" : "column",
503
+ "moduleName" : "PKTC-IETF-SIG-MIB",
504
+ "oid" : "1.3.6.1.2.1.169.1.1.1.1.2",
505
+ "status" : "current",
506
+ "syntax" : {
507
+ "type" : { "module" :"PKTC-IETF-SIG-MIB", "name" : "PktcCodecType"},
508
+ },
509
+ "access" : "noaccess",
510
+ "description" :
511
+ """ A codec type supported by this MTA.""",
512
+ }, # column
513
+ "pktcSigDevCodecMax" : {
514
+ "nodetype" : "column",
515
+ "moduleName" : "PKTC-IETF-SIG-MIB",
516
+ "oid" : "1.3.6.1.2.1.169.1.1.1.1.3",
517
+ "status" : "current",
518
+ "syntax" : {
519
+ "type" : {
520
+ "basetype" : "Unsigned32",
521
+ "ranges" : [
522
+ {
523
+ "min" : "1",
524
+ "max" : "255"
525
+ },
526
+ ],
527
+ "range" : {
528
+ "min" : "1",
529
+ "max" : "255"
530
+ },
531
+ },
532
+ },
533
+ "access" : "readonly",
534
+ "description" :
535
+ """ The maximum number of simultaneous sessions of a
536
+ particular codec that the MTA can support.""",
537
+ }, # column
538
+ "pktcSigDevEchoCancellation" : {
539
+ "nodetype" : "scalar",
540
+ "moduleName" : "PKTC-IETF-SIG-MIB",
541
+ "oid" : "1.3.6.1.2.1.169.1.1.2",
542
+ "status" : "current",
543
+ "syntax" : {
544
+ "type" : { "module" :"SNMPv2-TC", "name" : "TruthValue"},
545
+ },
546
+ "access" : "readonly",
547
+ "description" :
548
+ """ This object specifies if the device is capable of echo
549
+ cancellation. The MTA MUST set this MIB object to a
550
+ value of true(1) if it is capable of echo
551
+ cancellation, and a value of false(2) if not.""",
552
+ }, # scalar
553
+ "pktcSigDevSilenceSuppression" : {
554
+ "nodetype" : "scalar",
555
+ "moduleName" : "PKTC-IETF-SIG-MIB",
556
+ "oid" : "1.3.6.1.2.1.169.1.1.3",
557
+ "status" : "current",
558
+ "syntax" : {
559
+ "type" : { "module" :"SNMPv2-TC", "name" : "TruthValue"},
560
+ },
561
+ "access" : "readonly",
562
+ "description" :
563
+ """ This object specifies if the device is capable of
564
+ silence suppression (as a result of Voice Activity
565
+ Detection). The MTA MUST set this MIB object to a
566
+ value of true(1) if it is capable of silence
567
+ suppression, and a value of false(2) if not.""",
568
+ }, # scalar
569
+ "pktcSigDevCidSigProtocol" : {
570
+ "nodetype" : "scalar",
571
+ "moduleName" : "PKTC-IETF-SIG-MIB",
572
+ "oid" : "1.3.6.1.2.1.169.1.1.4",
573
+ "status" : "current",
574
+ "syntax" : {
575
+ "type" : { "module" :"PKTC-IETF-SIG-MIB", "name" : "PktcSubscriberSideSigProtocol"},
576
+ },
577
+ "access" : "readwrite",
578
+ "default" : "fsk",
579
+ "description" :
580
+ """This object is used to configure the subscriber-line
581
+ protocol used for signaling on-hook caller id information.
582
+
583
+
584
+
585
+ Different countries define different caller id signaling
586
+ protocols to support caller identification.
587
+
588
+ Setting this object at a value fsk(1) sets the subscriber
589
+ line protocol to be Frequency Shift Keying (FSK).
590
+
591
+ Setting this object at a value dtmf(2) sets the subscriber
592
+ line protocol to be Dual-Tone Multi-Frequency (DTMF).
593
+
594
+ The value of this MIB object MUST NOT persist across MTA
595
+ reboots.""",
596
+ "reference" :
597
+ """ETSI-EN-300-659-1 Specification""",
598
+ }, # scalar
599
+ "pktcSigDevR0Cadence" : {
600
+ "nodetype" : "scalar",
601
+ "moduleName" : "PKTC-IETF-SIG-MIB",
602
+ "oid" : "1.3.6.1.2.1.169.1.1.5",
603
+ "status" : "current",
604
+ "syntax" : {
605
+ "type" : { "module" :"PKTC-IETF-SIG-MIB", "name" : "PktcRingCadence"},
606
+ },
607
+ "access" : "readwrite",
608
+ "description" :
609
+ """ This object specifies ring cadence 0 (a user-defined
610
+ field).
611
+
612
+ The value of this MIB object MUST NOT persist across MTA
613
+ reboots.""",
614
+ }, # scalar
615
+ "pktcSigDevR1Cadence" : {
616
+ "nodetype" : "scalar",
617
+ "moduleName" : "PKTC-IETF-SIG-MIB",
618
+ "oid" : "1.3.6.1.2.1.169.1.1.6",
619
+ "status" : "current",
620
+ "syntax" : {
621
+ "type" : { "module" :"PKTC-IETF-SIG-MIB", "name" : "PktcRingCadence"},
622
+ },
623
+ "access" : "readwrite",
624
+ "description" :
625
+ """ This object specifies ring cadence 1 (a user-defined
626
+ field).
627
+
628
+ The value of this MIB object MUST NOT persist across MTA
629
+ reboots.""",
630
+ }, # scalar
631
+ "pktcSigDevR2Cadence" : {
632
+ "nodetype" : "scalar",
633
+ "moduleName" : "PKTC-IETF-SIG-MIB",
634
+ "oid" : "1.3.6.1.2.1.169.1.1.7",
635
+ "status" : "current",
636
+ "syntax" : {
637
+ "type" : { "module" :"PKTC-IETF-SIG-MIB", "name" : "PktcRingCadence"},
638
+ },
639
+ "access" : "readwrite",
640
+ "description" :
641
+ """ This object specifies ring cadence 2 (a user-defined
642
+ field).
643
+
644
+
645
+
646
+
647
+ The value of this MIB object MUST NOT persist across MTA
648
+ reboots.""",
649
+ }, # scalar
650
+ "pktcSigDevR3Cadence" : {
651
+ "nodetype" : "scalar",
652
+ "moduleName" : "PKTC-IETF-SIG-MIB",
653
+ "oid" : "1.3.6.1.2.1.169.1.1.8",
654
+ "status" : "current",
655
+ "syntax" : {
656
+ "type" : { "module" :"PKTC-IETF-SIG-MIB", "name" : "PktcRingCadence"},
657
+ },
658
+ "access" : "readwrite",
659
+ "description" :
660
+ """ This object specifies ring cadence 3 (a user-defined
661
+ field).
662
+
663
+ The value of this MIB object MUST NOT persist across MTA
664
+ reboots.""",
665
+ }, # scalar
666
+ "pktcSigDevR4Cadence" : {
667
+ "nodetype" : "scalar",
668
+ "moduleName" : "PKTC-IETF-SIG-MIB",
669
+ "oid" : "1.3.6.1.2.1.169.1.1.9",
670
+ "status" : "current",
671
+ "syntax" : {
672
+ "type" : { "module" :"PKTC-IETF-SIG-MIB", "name" : "PktcRingCadence"},
673
+ },
674
+ "access" : "readwrite",
675
+ "description" :
676
+ """ This object specifies ring cadence 4 (a user-defined
677
+ field).
678
+
679
+ The value of this MIB object MUST NOT persist across MTA
680
+ reboots.""",
681
+ }, # scalar
682
+ "pktcSigDevR5Cadence" : {
683
+ "nodetype" : "scalar",
684
+ "moduleName" : "PKTC-IETF-SIG-MIB",
685
+ "oid" : "1.3.6.1.2.1.169.1.1.10",
686
+ "status" : "current",
687
+ "syntax" : {
688
+ "type" : { "module" :"PKTC-IETF-SIG-MIB", "name" : "PktcRingCadence"},
689
+ },
690
+ "access" : "readwrite",
691
+ "description" :
692
+ """ This object specifies ring cadence 5 (a user-defined
693
+ field).
694
+
695
+ The value of this MIB object MUST NOT persist across MTA
696
+ reboots.""",
697
+ }, # scalar
698
+ "pktcSigDevR6Cadence" : {
699
+ "nodetype" : "scalar",
700
+ "moduleName" : "PKTC-IETF-SIG-MIB",
701
+ "oid" : "1.3.6.1.2.1.169.1.1.11",
702
+ "status" : "current",
703
+ "syntax" : {
704
+ "type" : { "module" :"PKTC-IETF-SIG-MIB", "name" : "PktcRingCadence"},
705
+ },
706
+ "access" : "readwrite",
707
+ "description" :
708
+ """ This object specifies ring cadence 6 (a user-defined
709
+ field).
710
+
711
+
712
+
713
+
714
+ The value of this MIB object MUST NOT persist across MTA
715
+ reboots.""",
716
+ }, # scalar
717
+ "pktcSigDevR7Cadence" : {
718
+ "nodetype" : "scalar",
719
+ "moduleName" : "PKTC-IETF-SIG-MIB",
720
+ "oid" : "1.3.6.1.2.1.169.1.1.12",
721
+ "status" : "current",
722
+ "syntax" : {
723
+ "type" : { "module" :"PKTC-IETF-SIG-MIB", "name" : "PktcRingCadence"},
724
+ },
725
+ "access" : "readwrite",
726
+ "description" :
727
+ """ This object specifies ring cadence 7 (a user-defined
728
+ field).
729
+
730
+ The value of this MIB object MUST NOT persist across MTA
731
+ reboots.""",
732
+ }, # scalar
733
+ "pktcSigDevRgCadence" : {
734
+ "nodetype" : "scalar",
735
+ "moduleName" : "PKTC-IETF-SIG-MIB",
736
+ "oid" : "1.3.6.1.2.1.169.1.1.13",
737
+ "status" : "current",
738
+ "syntax" : {
739
+ "type" : { "module" :"PKTC-IETF-SIG-MIB", "name" : "PktcRingCadence"},
740
+ },
741
+ "access" : "readwrite",
742
+ "description" :
743
+ """ This object specifies ring cadence rg (a user-defined
744
+ field).
745
+
746
+ The value of this MIB object MUST NOT persist across MTA
747
+ reboots.""",
748
+ }, # scalar
749
+ "pktcSigDevRsCadence" : {
750
+ "nodetype" : "scalar",
751
+ "moduleName" : "PKTC-IETF-SIG-MIB",
752
+ "oid" : "1.3.6.1.2.1.169.1.1.14",
753
+ "status" : "current",
754
+ "syntax" : {
755
+ "type" : { "module" :"PKTC-IETF-SIG-MIB", "name" : "PktcRingCadence"},
756
+ },
757
+ "access" : "readwrite",
758
+ "description" :
759
+ """ This object specifies ring cadence rs (a user-defined
760
+ field). The MTA MUST reject any attempt to make this object
761
+ repeatable.
762
+
763
+ The value of this MIB object MUST NOT persist across MTA
764
+ reboots.""",
765
+ }, # scalar
766
+ "pktcSigDefCallSigDscp" : {
767
+ "nodetype" : "scalar",
768
+ "moduleName" : "PKTC-IETF-SIG-MIB",
769
+ "oid" : "1.3.6.1.2.1.169.1.1.15",
770
+ "status" : "current",
771
+ "syntax" : {
772
+ "type" : { "module" :"DIFFSERV-DSCP-TC", "name" : "Dscp"},
773
+ },
774
+ "access" : "readwrite",
775
+ "default" : "0",
776
+ "description" :
777
+ """ The default value used in the IP header for setting the
778
+ Differentiated Services Code Point (DSCP) value for call
779
+
780
+
781
+
782
+ signaling.
783
+
784
+ The value of this MIB object MUST NOT persist across MTA
785
+ reboots.""",
786
+ }, # scalar
787
+ "pktcSigDefMediaStreamDscp" : {
788
+ "nodetype" : "scalar",
789
+ "moduleName" : "PKTC-IETF-SIG-MIB",
790
+ "oid" : "1.3.6.1.2.1.169.1.1.16",
791
+ "status" : "current",
792
+ "syntax" : {
793
+ "type" : { "module" :"DIFFSERV-DSCP-TC", "name" : "Dscp"},
794
+ },
795
+ "access" : "readwrite",
796
+ "default" : "0",
797
+ "description" :
798
+ """ This object contains the default value used in the IP
799
+ header for setting the Differentiated Services Code Point
800
+ (DSCP) value for media stream packets. The MTA MUST NOT
801
+ update this object with the value supplied by the CMS in
802
+ the NCS messages (if present). Any currently active
803
+ connections are not affected by updates to this object.
804
+ When the value of this object is updated by SNMP, the MTA
805
+ MUST use the new value as a default starting only from
806
+ new connections.
807
+
808
+ The value of this MIB object MUST NOT persist across MTA
809
+ reboots.""",
810
+ }, # scalar
811
+ "pktcSigCapabilityTable" : {
812
+ "nodetype" : "table",
813
+ "moduleName" : "PKTC-IETF-SIG-MIB",
814
+ "oid" : "1.3.6.1.2.1.169.1.1.17",
815
+ "status" : "current",
816
+ "description" :
817
+ """ This table describes the signaling types supported by this
818
+ MTA.""",
819
+ }, # table
820
+ "pktcSigCapabilityEntry" : {
821
+ "nodetype" : "row",
822
+ "moduleName" : "PKTC-IETF-SIG-MIB",
823
+ "oid" : "1.3.6.1.2.1.169.1.1.17.1",
824
+ "status" : "current",
825
+ "linkage" : [
826
+ "pktcSigCapabilityIndex",
827
+ ],
828
+ "description" :
829
+ """ Entries in pktcMtaDevSigCapabilityTable - list of
830
+ supported signaling types, versions, and vendor extensions
831
+
832
+
833
+
834
+ for this MTA. Each entry in the list provides for one
835
+ signaling type and version combination. If the device
836
+ supports multiple versions of the same signaling type, it
837
+ will require multiple entries.""",
838
+ }, # row
839
+ "pktcSigCapabilityIndex" : {
840
+ "nodetype" : "column",
841
+ "moduleName" : "PKTC-IETF-SIG-MIB",
842
+ "oid" : "1.3.6.1.2.1.169.1.1.17.1.1",
843
+ "status" : "current",
844
+ "syntax" : {
845
+ "type" : {
846
+ "basetype" : "Unsigned32",
847
+ "ranges" : [
848
+ {
849
+ "min" : "1",
850
+ "max" : "255"
851
+ },
852
+ ],
853
+ "range" : {
854
+ "min" : "1",
855
+ "max" : "255"
856
+ },
857
+ },
858
+ },
859
+ "access" : "noaccess",
860
+ "description" :
861
+ """ The index value that uniquely identifies an entry in the
862
+ pktcSigCapabilityTable.""",
863
+ }, # column
864
+ "pktcSigCapabilityType" : {
865
+ "nodetype" : "column",
866
+ "moduleName" : "PKTC-IETF-SIG-MIB",
867
+ "oid" : "1.3.6.1.2.1.169.1.1.17.1.2",
868
+ "status" : "current",
869
+ "syntax" : {
870
+ "type" : { "module" :"PKTC-IETF-SIG-MIB", "name" : "PktcSigType"},
871
+ },
872
+ "access" : "readonly",
873
+ "description" :
874
+ """ This object identifies the type of signaling used. This
875
+ value has to be associated with a single signaling
876
+ version.""",
877
+ }, # column
878
+ "pktcSigCapabilityVersion" : {
879
+ "nodetype" : "column",
880
+ "moduleName" : "PKTC-IETF-SIG-MIB",
881
+ "oid" : "1.3.6.1.2.1.169.1.1.17.1.3",
882
+ "status" : "current",
883
+ "syntax" : {
884
+ "type" : { "module" :"SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
885
+ },
886
+ "access" : "readonly",
887
+ "description" :
888
+ """ Provides the version of the signaling type - reference
889
+ pktcSigCapabilityType. Examples would be 1.0 or 2.33 etc.""",
890
+ }, # column
891
+ "pktcSigCapabilityVendorExt" : {
892
+ "nodetype" : "column",
893
+ "moduleName" : "PKTC-IETF-SIG-MIB",
894
+ "oid" : "1.3.6.1.2.1.169.1.1.17.1.4",
895
+ "status" : "current",
896
+ "syntax" : {
897
+ "type" : { "module" :"SNMP-FRAMEWORK-MIB", "name" : "SnmpAdminString"},
898
+ },
899
+ "access" : "readonly",
900
+ "description" :
901
+ """ The vendor extension allows vendors to provide a list of
902
+
903
+
904
+
905
+ additional capabilities.
906
+
907
+ The syntax for this MIB object in ABNF ([RFC5234]) is
908
+ specified to be zero or more occurrences of vendor
909
+ extensions, as follows:
910
+
911
+ pktcSigCapabilityVendorExt = *(vendor-extension)
912
+ vendor-extension = (ext symbol alphanum) DQUOTE ; DQUOTE
913
+ ext = DQUOTE %x58 DQUOTE
914
+ symbol = (DQUOTE %x2D DQUOTE)/(DQUOTE %x2D DQUOTE)
915
+ alphanum = 1*6(ALPHA/DIGIT)""",
916
+ }, # column
917
+ "pktcSigDefNcsReceiveUdpPort" : {
918
+ "nodetype" : "scalar",
919
+ "moduleName" : "PKTC-IETF-SIG-MIB",
920
+ "oid" : "1.3.6.1.2.1.169.1.1.18",
921
+ "status" : "current",
922
+ "syntax" : {
923
+ "type" : {
924
+ "basetype" : "Unsigned32",
925
+ "parent module" : {
926
+ "name" : "INET-ADDRESS-MIB",
927
+ "type" : "InetPortNumber",
928
+ },
929
+ "ranges" : [
930
+ {
931
+ "min" : "1025",
932
+ "max" : "65535"
933
+ },
934
+ ],
935
+ "range" : {
936
+ "min" : "1025",
937
+ "max" : "65535"
938
+ },
939
+ },
940
+ },
941
+ "access" : "readonly",
942
+ "description" :
943
+ """ This object contains the MTA User Datagram Protocol (UDP)
944
+ receive port that is being used for NCS call signaling.
945
+ This object should only be changed by the configuration
946
+ file.
947
+
948
+ Unless changed via configuration, this MIB object MUST
949
+ reflect a value of '2427'.""",
950
+ "reference" :
951
+ """PacketCable NCS Specification""",
952
+ }, # scalar
953
+ "pktcSigPowerRingFrequency" : {
954
+ "nodetype" : "scalar",
955
+ "moduleName" : "PKTC-IETF-SIG-MIB",
956
+ "oid" : "1.3.6.1.2.1.169.1.1.19",
957
+ "status" : "current",
958
+ "syntax" : {
959
+ "type" : {
960
+ "basetype" : "Enumeration",
961
+ "f20Hz" : {
962
+ "nodetype" : "namednumber",
963
+ "number" : "1"
964
+ },
965
+ "f25Hz" : {
966
+ "nodetype" : "namednumber",
967
+ "number" : "2"
968
+ },
969
+ "f33Point33Hz" : {
970
+ "nodetype" : "namednumber",
971
+ "number" : "3"
972
+ },
973
+ "f50Hz" : {
974
+ "nodetype" : "namednumber",
975
+ "number" : "4"
976
+ },
977
+ "f15Hz" : {
978
+ "nodetype" : "namednumber",
979
+ "number" : "5"
980
+ },
981
+ "f16Hz" : {
982
+ "nodetype" : "namednumber",
983
+ "number" : "6"
984
+ },
985
+ "f22Hz" : {
986
+ "nodetype" : "namednumber",
987
+ "number" : "7"
988
+ },
989
+ "f23Hz" : {
990
+ "nodetype" : "namednumber",
991
+ "number" : "8"
992
+ },
993
+ "f45Hz" : {
994
+ "nodetype" : "namednumber",
995
+ "number" : "9"
996
+ },
997
+ },
998
+ },
999
+ "access" : "readonly",
1000
+ "description" :
1001
+ """ This object must only be provided via the configuration
1002
+ file during the provisioning process. The power ring
1003
+
1004
+
1005
+
1006
+ frequency is the frequency at which the sinusoidal voltage
1007
+ must travel down the twisted pair to make terminal
1008
+ equipment ring. Different countries define different
1009
+ electrical characteristics to make terminal equipment
1010
+ ring.
1011
+
1012
+ The f20Hz setting corresponds to a power ring frequency
1013
+ of 20 Hertz. The f25Hz setting corresponds to a power ring
1014
+ frequency of 25 Hertz. The f33Point33Hz setting
1015
+ corresponds to a power ring frequency of 33.33 Hertz. The
1016
+ f50Hz setting corresponds to a power ring frequency of 50
1017
+ Hertz. The f15Hz setting corresponds to a power ring
1018
+ frequency of 15 Hertz. The f16Hz setting corresponds to a
1019
+ power ring frequency of 16 Hertz. The f22Hz setting
1020
+ corresponds to a power ring frequency of 22 Hertz. The
1021
+ f23Hz setting corresponds to a power ring frequency of 23
1022
+ Hertz. The f45Hz setting corresponds to a power ring
1023
+ frequency of 45 Hertz.""",
1024
+ "reference" :
1025
+ """ETSI-EN-300-001""",
1026
+ }, # scalar
1027
+ "pktcSigPulseSignalTable" : {
1028
+ "nodetype" : "table",
1029
+ "moduleName" : "PKTC-IETF-SIG-MIB",
1030
+ "oid" : "1.3.6.1.2.1.169.1.1.20",
1031
+ "status" : "current",
1032
+ "description" :
1033
+ """ The Pulse signal table defines the pulse signal operation.
1034
+ There are nine types of international pulse signals,
1035
+ with each signal having a set of provisionable parameters.
1036
+ The values of the MIB objects in this table take effect
1037
+ only if these parameters are not defined via signaling, in
1038
+ which case, the latter determines the values of the
1039
+ parameters. The MIB objects in this table do not persist
1040
+ across MTA reboots.""",
1041
+ "reference" :
1042
+ """ETSI-TS-101-909-4 Specification""",
1043
+ }, # table
1044
+ "pktcSigPulseSignalEntry" : {
1045
+ "nodetype" : "row",
1046
+ "moduleName" : "PKTC-IETF-SIG-MIB",
1047
+ "oid" : "1.3.6.1.2.1.169.1.1.20.1",
1048
+ "status" : "current",
1049
+ "linkage" : [
1050
+ "pktcSigPulseSignalType",
1051
+ ],
1052
+ "description" :
1053
+ """ This object defines the set of parameters associated with
1054
+ each particular value of pktcSigPulseSignalType. Each
1055
+ entry in the pktcSigPulseSignalTable is indexed by the
1056
+ pktcSigPulseSignalType object.
1057
+
1058
+
1059
+
1060
+ The conceptual rows MUST NOT persist across MTA reboots.""",
1061
+ }, # row
1062
+ "pktcSigPulseSignalType" : {
1063
+ "nodetype" : "column",
1064
+ "moduleName" : "PKTC-IETF-SIG-MIB",
1065
+ "oid" : "1.3.6.1.2.1.169.1.1.20.1.1",
1066
+ "status" : "current",
1067
+ "syntax" : {
1068
+ "type" : {
1069
+ "basetype" : "Enumeration",
1070
+ "initialRing" : {
1071
+ "nodetype" : "namednumber",
1072
+ "number" : "1"
1073
+ },
1074
+ "pulseLoopClose" : {
1075
+ "nodetype" : "namednumber",
1076
+ "number" : "2"
1077
+ },
1078
+ "pulseLoopOpen" : {
1079
+ "nodetype" : "namednumber",
1080
+ "number" : "3"
1081
+ },
1082
+ "enableMeterPulse" : {
1083
+ "nodetype" : "namednumber",
1084
+ "number" : "4"
1085
+ },
1086
+ "meterPulseBurst" : {
1087
+ "nodetype" : "namednumber",
1088
+ "number" : "5"
1089
+ },
1090
+ "pulseNoBattery" : {
1091
+ "nodetype" : "namednumber",
1092
+ "number" : "6"
1093
+ },
1094
+ "pulseNormalPolarity" : {
1095
+ "nodetype" : "namednumber",
1096
+ "number" : "7"
1097
+ },
1098
+ "pulseReducedBattery" : {
1099
+ "nodetype" : "namednumber",
1100
+ "number" : "8"
1101
+ },
1102
+ "pulseReversePolarity" : {
1103
+ "nodetype" : "namednumber",
1104
+ "number" : "9"
1105
+ },
1106
+ },
1107
+ },
1108
+ "access" : "noaccess",
1109
+ "description" :
1110
+ """There are nine types of international pulse signals. These
1111
+ signals are defined as follows:
1112
+ initial ring
1113
+ pulse loop close
1114
+ pulse loop open
1115
+ enable meter pulse
1116
+ meter pulse burst
1117
+ pulse no battery
1118
+ pulse normal polarity
1119
+ pulse reduced battery
1120
+ pulse reverse polarity""",
1121
+ "reference" :
1122
+ """ETSI-EN-300-324-1 Specification""",
1123
+ }, # column
1124
+ "pktcSigPulseSignalFrequency" : {
1125
+ "nodetype" : "column",
1126
+ "moduleName" : "PKTC-IETF-SIG-MIB",
1127
+ "oid" : "1.3.6.1.2.1.169.1.1.20.1.2",
1128
+ "status" : "current",
1129
+ "syntax" : {
1130
+ "type" : {
1131
+ "basetype" : "Enumeration",
1132
+ "twentyfive" : {
1133
+ "nodetype" : "namednumber",
1134
+ "number" : "1"
1135
+ },
1136
+ "twelvethousand" : {
1137
+ "nodetype" : "namednumber",
1138
+ "number" : "2"
1139
+ },
1140
+ "sixteenthousand" : {
1141
+ "nodetype" : "namednumber",
1142
+ "number" : "3"
1143
+ },
1144
+ },
1145
+ },
1146
+ "access" : "readwrite",
1147
+ "description" :
1148
+ """ This object is only applicable to the initialRing,
1149
+ enableMeterPulse, and meterPulseBurst signal types. This
1150
+ object identifies the frequency of the generated signal.
1151
+ The following table defines the default values for this
1152
+ object depending on signal type:
1153
+
1154
+ pktcSigPulseSignalType Default
1155
+ initialRing 25
1156
+ enableMeterPulse 16000
1157
+ meterPulseBurst 16000
1158
+
1159
+ The value of twentyfive MUST only be used for the
1160
+ initialRing signal type. The values of twelvethousand and
1161
+ sixteenthousand MUST only be used for enableMeterPulse and
1162
+ meterPulseBurst signal types. An attempt to set this
1163
+ object while the value of pktcSigPulseSignalType is not
1164
+ initialRing, enableMeterPulse, or meterPulseBurst will
1165
+ result in an 'inconsistentValue' error.""",
1166
+ "reference" :
1167
+ """ETSI-EN-300-001 Specification""",
1168
+ }, # column
1169
+ "pktcSigPulseSignalDbLevel" : {
1170
+ "nodetype" : "column",
1171
+ "moduleName" : "PKTC-IETF-SIG-MIB",
1172
+ "oid" : "1.3.6.1.2.1.169.1.1.20.1.3",
1173
+ "status" : "current",
1174
+ "syntax" : {
1175
+ "type" : {
1176
+ "basetype" : "Integer32",
1177
+ "parent module" : {
1178
+ "name" : "PKTC-IETF-SIG-MIB",
1179
+ "type" : "TenthdBm",
1180
+ },
1181
+ "ranges" : [
1182
+ {
1183
+ "min" : "-350",
1184
+ "max" : "0"
1185
+ },
1186
+ ],
1187
+ "range" : {
1188
+ "min" : "-350",
1189
+ "max" : "0"
1190
+ },
1191
+ },
1192
+ },
1193
+ "access" : "readwrite",
1194
+ "default" : "-135",
1195
+ "units" : "1/10 of a dBm",
1196
+ "description" :
1197
+ """ This object is only applicable to the enableMeterPulse and
1198
+ meterPulseBurst signal types. This is the decibel level
1199
+ for each frequency at which tones could be generated at
1200
+ the a and b terminals (TE connection point). An attempt to
1201
+ set this object while the value of pktcSigPulseSignalType
1202
+ is not enableMeterPulse or meterPulseBurst will result in
1203
+ an 'inconsistentValue' error.""",
1204
+ "reference" :
1205
+ """ETSI-EN-300-001 Specification""",
1206
+ }, # column
1207
+ "pktcSigPulseSignalDuration" : {
1208
+ "nodetype" : "column",
1209
+ "moduleName" : "PKTC-IETF-SIG-MIB",
1210
+ "oid" : "1.3.6.1.2.1.169.1.1.20.1.4",
1211
+ "status" : "current",
1212
+ "syntax" : {
1213
+ "type" : {
1214
+ "basetype" : "Unsigned32",
1215
+ "ranges" : [
1216
+ {
1217
+ "min" : "0",
1218
+ "max" : "5000"
1219
+ },
1220
+ ],
1221
+ "range" : {
1222
+ "min" : "0",
1223
+ "max" : "5000"
1224
+ },
1225
+ },
1226
+ },
1227
+ "access" : "readwrite",
1228
+ "units" : "Milliseconds",
1229
+ "description" :
1230
+ """ This object specifies the pulse duration for each
1231
+ signal type. In addition, the MTA must accept the values
1232
+ in the incremental steps specific for each signal type.
1233
+ The following table defines the default values and the
1234
+ incremental steps for this object depending on the signal
1235
+ type:
1236
+
1237
+ pktcSigPulseSignaltype Default (ms) Increment (ms)
1238
+ initialRing 200 50
1239
+ pulseLoopClose 200 10
1240
+ pulseLoopOpen 200 10
1241
+ enableMeterPulse 150 10
1242
+ meterPulseBurst 150 10
1243
+ pulseNoBattery 200 10
1244
+ pulseNormalPolarity 200 10
1245
+ pulseReducedBattery 200 10
1246
+ pulseReversePolarity 200 10
1247
+
1248
+ An attempt to set this object to a value that does not
1249
+ fall on one of the increment boundaries, or on the wrong
1250
+ increment boundary for the specific signal type, will
1251
+ result in an 'inconsistentValue' error.""",
1252
+ "reference" :
1253
+ """ETSI-EN-300-324-1 Specification""",
1254
+ }, # column
1255
+ "pktcSigPulseSignalPulseInterval" : {
1256
+ "nodetype" : "column",
1257
+ "moduleName" : "PKTC-IETF-SIG-MIB",
1258
+ "oid" : "1.3.6.1.2.1.169.1.1.20.1.5",
1259
+ "status" : "current",
1260
+ "syntax" : {
1261
+ "type" : {
1262
+ "basetype" : "Unsigned32",
1263
+ "ranges" : [
1264
+ {
1265
+ "min" : "0",
1266
+ "max" : "5000"
1267
+ },
1268
+ ],
1269
+ "range" : {
1270
+ "min" : "0",
1271
+ "max" : "5000"
1272
+ },
1273
+ },
1274
+ },
1275
+ "access" : "readwrite",
1276
+ "units" : "Milliseconds",
1277
+ "description" :
1278
+ """ This object specifies the repeat interval, or the period,
1279
+ for each signal type. In addition, the MTA must accept
1280
+ the values in the incremental steps specific for each
1281
+ signal type. The following table defines the default
1282
+ values and the incremental steps for this object, depending
1283
+ on the signal type:
1284
+
1285
+ pktcSigPulseSignaltype Default (ms) Increment (ms)
1286
+ initialRing 200 50
1287
+ pulseLoopClose 1000 10
1288
+ pulseLoopOpen 1000 10
1289
+
1290
+
1291
+
1292
+ enableMeterPulse 1000 10
1293
+ meterPulseBurst 1000 10
1294
+ pulseNoBattery 1000 10
1295
+ pulseNormalPolarity 1000 10
1296
+ pulseReducedBattery 1000 10
1297
+ pulseReversePolarity 1000 10
1298
+
1299
+ An attempt to set this object to a value that does not
1300
+ fall on one of the increment boundaries, or on the wrong
1301
+ increment boundary for the specific signal type, will
1302
+ result in an 'inconsistentValue' error.""",
1303
+ "reference" :
1304
+ """ETSI-EN-300-324-1 Specification""",
1305
+ }, # column
1306
+ "pktcSigPulseSignalRepeatCount" : {
1307
+ "nodetype" : "column",
1308
+ "moduleName" : "PKTC-IETF-SIG-MIB",
1309
+ "oid" : "1.3.6.1.2.1.169.1.1.20.1.6",
1310
+ "status" : "current",
1311
+ "syntax" : {
1312
+ "type" : {
1313
+ "basetype" : "Unsigned32",
1314
+ "ranges" : [
1315
+ {
1316
+ "min" : "1",
1317
+ "max" : "50"
1318
+ },
1319
+ ],
1320
+ "range" : {
1321
+ "min" : "1",
1322
+ "max" : "50"
1323
+ },
1324
+ },
1325
+ },
1326
+ "access" : "readwrite",
1327
+ "description" :
1328
+ """ This object specifies how many times to repeat a pulse.
1329
+ This object is not used by the enableMeterPulse signal
1330
+ type, and in that case, the value is irrelevant. The
1331
+ following table defines the default values and the valid
1332
+ ranges for this object, depending on the signal type:
1333
+
1334
+ pktcSigPulseSignaltype Default Range
1335
+
1336
+ initialRing 1 1-5
1337
+ pulseLoopClose 1 1-50
1338
+ pulseLoopOpen 1 1-50
1339
+ enableMeterPulse (any value)(but not used)
1340
+ meterPulseBurst 1 1-50
1341
+ pulseNoBattery 1 1-50
1342
+ pulseNormalPolarity 1 1-50
1343
+ pulseReducedBattery 1 1-50
1344
+ pulseReversePolarity 1 1-50
1345
+
1346
+ An attempt to set this object to a value that does not
1347
+ fall within the range for the specific
1348
+ signal type will result in an 'inconsistentValue' error.""",
1349
+ }, # column
1350
+ "pktcSigDevCidMode" : {
1351
+ "nodetype" : "scalar",
1352
+ "moduleName" : "PKTC-IETF-SIG-MIB",
1353
+ "oid" : "1.3.6.1.2.1.169.1.1.21",
1354
+ "status" : "current",
1355
+ "syntax" : {
1356
+ "type" : {
1357
+ "basetype" : "Enumeration",
1358
+ "duringRingingETS" : {
1359
+ "nodetype" : "namednumber",
1360
+ "number" : "1"
1361
+ },
1362
+ "dtAsETS" : {
1363
+ "nodetype" : "namednumber",
1364
+ "number" : "2"
1365
+ },
1366
+ "rpAsETS" : {
1367
+ "nodetype" : "namednumber",
1368
+ "number" : "3"
1369
+ },
1370
+ "lrAsETS" : {
1371
+ "nodetype" : "namednumber",
1372
+ "number" : "4"
1373
+ },
1374
+ "lrETS" : {
1375
+ "nodetype" : "namednumber",
1376
+ "number" : "5"
1377
+ },
1378
+ },
1379
+ },
1380
+ "access" : "readwrite",
1381
+ "default" : "rpAsETS",
1382
+ "description" :
1383
+ """ For on-hook caller id, pktcSigDevCidMode selects the method
1384
+ for representing and signaling caller identification. For
1385
+ the duringRingingETS method, the Frequency Shift Keying
1386
+ (FSK) or the Dual-Tone Multi-Frequency (DTMF) containing
1387
+ the caller identification information is sent between the
1388
+ first and second ring pattern.
1389
+
1390
+ For the dtAsETS,rpAsETS, lrAsETS and lrETS
1391
+ methods, the FSK or DTMF containing the caller id
1392
+ information is sent before the first ring pattern.
1393
+
1394
+ For the dtAsETS method, the FSK or DTMF is sent after the
1395
+ Dual Tone Alert Signal. For the rpAsETS method, the FSK or
1396
+ DTMF is sent after a Ring Pulse.
1397
+
1398
+ For the lrAsETS method, the Line Reversal occurs first,
1399
+ then the Dual Tone Alert Signal, and, finally, the FSK or
1400
+ DTMF is sent.
1401
+
1402
+ For the lrETS method, the Line Reversal occurs first,
1403
+ then the FSK or DTMF is sent.
1404
+
1405
+ The value of this MIB object MUST NOT persist across MTA
1406
+ reboots.""",
1407
+ }, # scalar
1408
+ "pktcSigDevCidAfterRing" : {
1409
+ "nodetype" : "scalar",
1410
+ "moduleName" : "PKTC-IETF-SIG-MIB",
1411
+ "oid" : "1.3.6.1.2.1.169.1.1.22",
1412
+ "status" : "current",
1413
+ "syntax" : {
1414
+ "type" : {
1415
+ "basetype" : "Unsigned32",
1416
+ "ranges" : [
1417
+ {
1418
+ "min" : "0",
1419
+ "max" : "0"
1420
+ },
1421
+ {
1422
+ "min" : "50",
1423
+ "max" : "2000"
1424
+ },
1425
+ ],
1426
+ "range" : {
1427
+ "min" : "0",
1428
+ "max" : "2000"
1429
+ },
1430
+ },
1431
+ },
1432
+ "access" : "readwrite",
1433
+ "default" : "550",
1434
+ "units" : "Milliseconds",
1435
+ "description" :
1436
+ """ This object specifies the delay between the end of first
1437
+ ringing pattern and the start of the transmission of the
1438
+ FSK or DTMF containing the caller id information. It is
1439
+ only used when pktcSigDevCidMode is set to a value of
1440
+ 'duringRingingETS'.
1441
+
1442
+ The following table defines the default values
1443
+ for this MIB object, depending on the signal type
1444
+
1445
+
1446
+
1447
+ (pktcSigDevCidMode), and MUST be followed:
1448
+
1449
+ Value of pktcSigDevCidMode Default value
1450
+
1451
+ duringringingETS 550 ms
1452
+ dtAsETS any value (not used)
1453
+ rpAsETS any value (not used)
1454
+ lrAsETS any value (not used)
1455
+ lrETS any value (not used)
1456
+
1457
+ An attempt to set this object while the value of
1458
+ pktcSigDevCidMode is not duringringingETS will result in
1459
+ an 'inconsistentValue' error.
1460
+
1461
+ The value of this MIB object MUST NOT persist across MTA
1462
+ reboots.""",
1463
+ "reference" :
1464
+ """ETSI-EN-300-659-1 Specification""",
1465
+ }, # scalar
1466
+ "pktcSigDevCidAfterDTAS" : {
1467
+ "nodetype" : "scalar",
1468
+ "moduleName" : "PKTC-IETF-SIG-MIB",
1469
+ "oid" : "1.3.6.1.2.1.169.1.1.23",
1470
+ "status" : "current",
1471
+ "syntax" : {
1472
+ "type" : {
1473
+ "basetype" : "Unsigned32",
1474
+ "ranges" : [
1475
+ {
1476
+ "min" : "0",
1477
+ "max" : "0"
1478
+ },
1479
+ {
1480
+ "min" : "45",
1481
+ "max" : "500"
1482
+ },
1483
+ ],
1484
+ "range" : {
1485
+ "min" : "0",
1486
+ "max" : "500"
1487
+ },
1488
+ },
1489
+ },
1490
+ "access" : "readwrite",
1491
+ "default" : "50",
1492
+ "units" : "Milliseconds",
1493
+ "description" :
1494
+ """ This object specifies the delay between the end of the
1495
+ Dual Tone Alert Signal (DT-AS) and the start of the
1496
+ transmission of the FSK or DTMF containing the caller id
1497
+ information. This object is only used when
1498
+ pktcSigDevCidMode is set to a value of 'dtAsETS' or
1499
+ 'lrAsETS'.
1500
+
1501
+ The following table defines the default values
1502
+ for this MIB object, depending on the signal type
1503
+ (pktcSigDevCidMode), and MUST be followed:
1504
+
1505
+ Value of pktcSigDevCidMode Default value
1506
+
1507
+
1508
+ duringringingETS any value (not used)
1509
+ dtAsETS 50 ms
1510
+ rpAsETS any value (not used)
1511
+ lrAsETS 50 ms
1512
+ lrETS any value (not used)
1513
+
1514
+ An attempt to set this object while the value of
1515
+
1516
+
1517
+
1518
+ pktcSigDevCidMode is not 'dtAsETS' or 'lrAsETS' will
1519
+ result in an 'inconsistentValue' error.
1520
+
1521
+ The value of this MIB object MUST NOT persist across MTA
1522
+ reboots.""",
1523
+ "reference" :
1524
+ """ETSI-EN-300-659-1 Specification""",
1525
+ }, # scalar
1526
+ "pktcSigDevCidAfterRPAS" : {
1527
+ "nodetype" : "scalar",
1528
+ "moduleName" : "PKTC-IETF-SIG-MIB",
1529
+ "oid" : "1.3.6.1.2.1.169.1.1.24",
1530
+ "status" : "current",
1531
+ "syntax" : {
1532
+ "type" : {
1533
+ "basetype" : "Unsigned32",
1534
+ "ranges" : [
1535
+ {
1536
+ "min" : "0",
1537
+ "max" : "0"
1538
+ },
1539
+ {
1540
+ "min" : "500",
1541
+ "max" : "800"
1542
+ },
1543
+ ],
1544
+ "range" : {
1545
+ "min" : "0",
1546
+ "max" : "800"
1547
+ },
1548
+ },
1549
+ },
1550
+ "access" : "readwrite",
1551
+ "default" : "650",
1552
+ "units" : "Milliseconds",
1553
+ "description" :
1554
+ """ This object specifies the delay between the end of the
1555
+ Ring Pulse Alert Signal (RP-AS) and the start of the
1556
+ transmission of the FSK or DTMF containing the caller id
1557
+ information. This MIB object is only used when
1558
+ pktcSigDevCidMode is set to a value of 'rpAsETS'.
1559
+ The following table defines the default values
1560
+ for this MIB object, depending on the signal type
1561
+ (pktcSigDevCidMode), and MUST be followed:
1562
+
1563
+ Value of pktcSigDevCidMode Default value
1564
+
1565
+ duringringingETS any value (not used)
1566
+ dtAsETS any value (not used)
1567
+ rpAsETS 650 ms
1568
+ lrAsETS any value (not used)
1569
+ lrETS any value (not used)
1570
+
1571
+ An attempt to set this object while the value of
1572
+ pktcSigDevCidMode is not 'rpAsETS' will result in an
1573
+ 'inconsistentValue' error.
1574
+
1575
+ The value of this MIB object MUST NOT persist across MTA
1576
+ reboots.""",
1577
+ "reference" :
1578
+ """ETSI-EN-300-659-1 Specification""",
1579
+ }, # scalar
1580
+ "pktcSigDevRingAfterCID" : {
1581
+ "nodetype" : "scalar",
1582
+ "moduleName" : "PKTC-IETF-SIG-MIB",
1583
+ "oid" : "1.3.6.1.2.1.169.1.1.25",
1584
+ "status" : "current",
1585
+ "syntax" : {
1586
+ "type" : {
1587
+ "basetype" : "Unsigned32",
1588
+ "ranges" : [
1589
+ {
1590
+ "min" : "0",
1591
+ "max" : "0"
1592
+ },
1593
+ {
1594
+ "min" : "50",
1595
+ "max" : "500"
1596
+ },
1597
+ ],
1598
+ "range" : {
1599
+ "min" : "0",
1600
+ "max" : "500"
1601
+ },
1602
+ },
1603
+ },
1604
+ "access" : "readwrite",
1605
+ "default" : "250",
1606
+ "units" : "Milliseconds",
1607
+ "description" :
1608
+ """ This object specifies the delay between the end of the
1609
+ complete transmission of the FSK or DTMF containing the
1610
+ caller id information and the start of the first ring
1611
+ pattern. It is only used when pktcSigDevCidMode is
1612
+ set to a value of 'dtAsETS', 'rpAsETS', 'lrAsETS' or
1613
+ 'lrETS'.
1614
+
1615
+ The following table defines the default values
1616
+ for this MIB object, depending on the signal type
1617
+ (pktcSigDevCidMode), and MUST be followed:
1618
+
1619
+ Value of pktcSigDevCidMode Default value
1620
+
1621
+ duringringingETS any value (not used)
1622
+ dtAsETS 250 ms
1623
+ rpAsETS 250 ms
1624
+ lrAsETS 250 ms
1625
+ lrETS 250 ms
1626
+
1627
+ An attempt to set this object while the value of
1628
+ pktcSigDevCidMode is not 'dtAsETS', 'rpAsETS',
1629
+ 'lrAsETS', or 'lrETS' will result in an 'inconsistent
1630
+ value' error.
1631
+
1632
+ The value of this MIB object MUST NOT persist across MTA
1633
+ reboots.""",
1634
+ "reference" :
1635
+ """ETSI-EN-300-659-1 Specification""",
1636
+ }, # scalar
1637
+ "pktcSigDevCidDTASAfterLR" : {
1638
+ "nodetype" : "scalar",
1639
+ "moduleName" : "PKTC-IETF-SIG-MIB",
1640
+ "oid" : "1.3.6.1.2.1.169.1.1.26",
1641
+ "status" : "current",
1642
+ "syntax" : {
1643
+ "type" : {
1644
+ "basetype" : "Unsigned32",
1645
+ "ranges" : [
1646
+ {
1647
+ "min" : "50",
1648
+ "max" : "655"
1649
+ },
1650
+ ],
1651
+ "range" : {
1652
+ "min" : "50",
1653
+ "max" : "655"
1654
+ },
1655
+ },
1656
+ },
1657
+ "access" : "readwrite",
1658
+ "default" : "250",
1659
+ "units" : "Milliseconds",
1660
+ "description" :
1661
+ """ This object specifies the delay between the end of the
1662
+ Line Reversal and the start of the Dual Tone Alert Signal
1663
+ (DT-AS). This object is only used when pktcSigDevCidMode
1664
+ is set to a value of 'lrAsETS'.
1665
+
1666
+ The following table defines the default values
1667
+ for this MIB object, depending on the signal type
1668
+ (pktcSigDevCidMode), and MUST be followed:
1669
+
1670
+
1671
+
1672
+
1673
+ Value of pktcSigDevCidMode Default value
1674
+
1675
+ duringringingETS any value (not used)
1676
+ dtAsETS any value (not used)
1677
+ rpAsETS any value (not used)
1678
+ lrAsETS 250 ms
1679
+ lrETS any value (not used)
1680
+
1681
+ An attempt to set this object while the value of
1682
+ pktcSigDevCidMode is not lrAsETS will result in an
1683
+ 'inconsistentValue' error.
1684
+
1685
+ The value of this MIB object MUST NOT persist across MTA
1686
+ reboots.""",
1687
+ "reference" :
1688
+ """ETSI-EN-300-659-1 Specification""",
1689
+ }, # scalar
1690
+ "pktcSigDevVmwiMode" : {
1691
+ "nodetype" : "scalar",
1692
+ "moduleName" : "PKTC-IETF-SIG-MIB",
1693
+ "oid" : "1.3.6.1.2.1.169.1.1.27",
1694
+ "status" : "current",
1695
+ "syntax" : {
1696
+ "type" : {
1697
+ "basetype" : "Enumeration",
1698
+ "dtAsETS" : {
1699
+ "nodetype" : "namednumber",
1700
+ "number" : "1"
1701
+ },
1702
+ "rpAsETS" : {
1703
+ "nodetype" : "namednumber",
1704
+ "number" : "2"
1705
+ },
1706
+ "lrAsETS" : {
1707
+ "nodetype" : "namednumber",
1708
+ "number" : "3"
1709
+ },
1710
+ "osi" : {
1711
+ "nodetype" : "namednumber",
1712
+ "number" : "4"
1713
+ },
1714
+ "lrETS" : {
1715
+ "nodetype" : "namednumber",
1716
+ "number" : "5"
1717
+ },
1718
+ },
1719
+ },
1720
+ "access" : "readwrite",
1721
+ "default" : "rpAsETS",
1722
+ "description" :
1723
+ """ For visual message waiting indicator (VMWI),
1724
+ pktcSigDevVmwiMode selects the alerting signal method. For
1725
+ the dtAsETS, rpAsETS, lrAsETS, osi, and lrETS methods,
1726
+ the FSK containing the VMWI information is sent after an
1727
+ alerting signal.
1728
+
1729
+ For the dtAsETS method, the FSK, or DTMF
1730
+ is sent after the Dual Tone Alert Signal. For the rpAsETS
1731
+ method, the FSK or DTMF is sent after a Ring Pulse.
1732
+
1733
+ For the lrAsETS method, the Line Reversal occurs first,
1734
+ then the Dual Tone Alert Signal, and, finally, the FSK or
1735
+ DTMF is sent.
1736
+
1737
+ For the OSI method, the FSK or DTMF is sent after the Open
1738
+ Switching Interval.
1739
+
1740
+
1741
+
1742
+
1743
+ For the lrETS method, the Line Reversal occurs first,
1744
+ then the FSK or DTMF is sent.
1745
+
1746
+ The value of this MIB object MUST NOT persist across MTA
1747
+ reboots.""",
1748
+ }, # scalar
1749
+ "pktcSigDevVmwiAfterDTAS" : {
1750
+ "nodetype" : "scalar",
1751
+ "moduleName" : "PKTC-IETF-SIG-MIB",
1752
+ "oid" : "1.3.6.1.2.1.169.1.1.28",
1753
+ "status" : "current",
1754
+ "syntax" : {
1755
+ "type" : {
1756
+ "basetype" : "Unsigned32",
1757
+ "ranges" : [
1758
+ {
1759
+ "min" : "0",
1760
+ "max" : "0"
1761
+ },
1762
+ {
1763
+ "min" : "45",
1764
+ "max" : "500"
1765
+ },
1766
+ ],
1767
+ "range" : {
1768
+ "min" : "0",
1769
+ "max" : "500"
1770
+ },
1771
+ },
1772
+ },
1773
+ "access" : "readwrite",
1774
+ "default" : "50",
1775
+ "units" : "Milliseconds",
1776
+ "description" :
1777
+ """ This object specifies the delay between the end of the
1778
+ Dual Tone Alert Signal (DT-AS) and the start of the
1779
+ transmission of the FSK or DTMF containing the VMWI
1780
+ information.
1781
+
1782
+ This object is only used when pktcSigDevVmwiMode is
1783
+ set to a value of 'dtAsETS' or 'lrAsETS'.
1784
+
1785
+ The following table defines the default values
1786
+ for this MIB object, depending on the signal type
1787
+ (pktcSigDevVmwiMode), and MUST be followed:
1788
+
1789
+ Value of pktcSigDevVmwiMode Default value
1790
+
1791
+ dtAsETS 50 ms
1792
+ rpAsETS any value (not used)
1793
+ lrAsETS 50 ms
1794
+ lrETS any value (not used)
1795
+
1796
+ An attempt to set this object while the value of
1797
+ pktcSigDevVmwiMode is not 'dtAsETS' or 'lrAsETS' will
1798
+ result in an 'inconsistentValue' error.
1799
+
1800
+ The value of this MIB object MUST NOT persist across MTA
1801
+ reboots.""",
1802
+ "reference" :
1803
+ """ETSI-EN-300-659-1 Specification""",
1804
+ }, # scalar
1805
+ "pktcSigDevVmwiAfterRPAS" : {
1806
+ "nodetype" : "scalar",
1807
+ "moduleName" : "PKTC-IETF-SIG-MIB",
1808
+ "oid" : "1.3.6.1.2.1.169.1.1.29",
1809
+ "status" : "current",
1810
+ "syntax" : {
1811
+ "type" : {
1812
+ "basetype" : "Unsigned32",
1813
+ "ranges" : [
1814
+ {
1815
+ "min" : "0",
1816
+ "max" : "0"
1817
+ },
1818
+ {
1819
+ "min" : "500",
1820
+ "max" : "800"
1821
+ },
1822
+ ],
1823
+ "range" : {
1824
+ "min" : "0",
1825
+ "max" : "800"
1826
+ },
1827
+ },
1828
+ },
1829
+ "access" : "readwrite",
1830
+ "default" : "650",
1831
+ "units" : "Milliseconds",
1832
+ "description" :
1833
+ """ This object specifies the delay between the end of the
1834
+ Ring Pulse Alert Signal (RP-AS) and the start of the
1835
+ transmission of the FSK or DTMF containing the VMWI
1836
+ information.
1837
+
1838
+ This object is only used when pktcSigDevVmwiMode is
1839
+ set to a value of 'rpAsETS'.
1840
+
1841
+ The following table defines the default values
1842
+ for this MIB object, depending on the signal type
1843
+ (pktcSigDevVmwiMode), and MUST be followed:
1844
+
1845
+ Value of pktcSigDevVmwiMode Default value
1846
+
1847
+ dtAsETS any value (not used)
1848
+ rpAsETS 650 ms
1849
+ lrAsETS any value (not used)
1850
+ lrETS any value (not used)
1851
+
1852
+ An attempt to set this object while the value of
1853
+ pktcSigDevVmwiMode is not 'rpAsETS' will result in an
1854
+ 'inconsistentValue' error.
1855
+
1856
+ The value of this MIB object MUST NOT persist across MTA
1857
+ reboots.""",
1858
+ "reference" :
1859
+ """ETSI-EN-300-659-1 Specification""",
1860
+ }, # scalar
1861
+ "pktcSigDevVmwiDTASAfterLR" : {
1862
+ "nodetype" : "scalar",
1863
+ "moduleName" : "PKTC-IETF-SIG-MIB",
1864
+ "oid" : "1.3.6.1.2.1.169.1.1.30",
1865
+ "status" : "current",
1866
+ "syntax" : {
1867
+ "type" : {
1868
+ "basetype" : "Unsigned32",
1869
+ "ranges" : [
1870
+ {
1871
+ "min" : "0",
1872
+ "max" : "0"
1873
+ },
1874
+ {
1875
+ "min" : "50",
1876
+ "max" : "655"
1877
+ },
1878
+ ],
1879
+ "range" : {
1880
+ "min" : "0",
1881
+ "max" : "655"
1882
+ },
1883
+ },
1884
+ },
1885
+ "access" : "readwrite",
1886
+ "default" : "250",
1887
+ "units" : "Milliseconds",
1888
+ "description" :
1889
+ """ This object specifies the delay between the end of the
1890
+ Line Reversal and the start of the Dual Tone Alert Signal
1891
+ (DT-AS) for VMWI information. This object is only used
1892
+ when pktcSigDevVmwiMode is set to a value of 'lrAsETS'.
1893
+
1894
+ The following table defines the default values
1895
+ for this MIB object, depending on the signal type
1896
+ (pktcSigDevVmwiMode), and MUST be followed:
1897
+
1898
+
1899
+
1900
+
1901
+ Value of pktcSigDevVmwiMode Default value
1902
+
1903
+ dtAsETS any value (not used)
1904
+ rpAsETS any value (not used)
1905
+ lrAsETS 250 ms
1906
+ lrETS any value (not used)
1907
+
1908
+ An attempt to set this object while the value of
1909
+ pktcSigDevVmwiMode is not 'lrAsETS' will result in an
1910
+ 'inconsistentValue' error.
1911
+
1912
+ The value of this MIB object MUST NOT persist across MTA
1913
+ reboots.""",
1914
+ "reference" :
1915
+ """ETSI-EN-300-659-1 Specification""",
1916
+ }, # scalar
1917
+ "pktcSigDevRingCadenceTable" : {
1918
+ "nodetype" : "table",
1919
+ "moduleName" : "PKTC-IETF-SIG-MIB",
1920
+ "oid" : "1.3.6.1.2.1.169.1.1.31",
1921
+ "status" : "current",
1922
+ "description" :
1923
+ """Cadence rings are defined by the telco governing
1924
+ body for each country. The MTA must be able to support
1925
+ various ranges of cadence patterns and cadence periods.
1926
+ The MTA will be able to support country-specific
1927
+ provisioning of the cadence and idle period. Each
1928
+ cadence pattern will be assigned a unique value ranging
1929
+ from 0-127 (inclusive) corresponding to the value of x,
1930
+ where x is the value sent in the cadence ringing (cr)
1931
+ signal cr(x), requested per the appropriate NCS
1932
+ message, and defined in the E package. The MTA will derive
1933
+ the cadence periods from the ring cadence table entry, as
1934
+ provisioned by the customer. The MTA is allowed to provide
1935
+ appropriate default values for each of the ring cadences.
1936
+ This table only needs to be supported when the MTA
1937
+ implements the E package.""",
1938
+ "reference" :
1939
+ """ETSI-TS-101-909-4 Specification""",
1940
+ }, # table
1941
+ "pktcSigDevRingCadenceEntry" : {
1942
+ "nodetype" : "row",
1943
+ "moduleName" : "PKTC-IETF-SIG-MIB",
1944
+ "oid" : "1.3.6.1.2.1.169.1.1.31.1",
1945
+ "status" : "current",
1946
+ "linkage" : [
1947
+ "pktcSigDevRingCadenceIndex",
1948
+ ],
1949
+ "description" :
1950
+ """ Each entry in this row corresponds to a ring cadence
1951
+ that is being supported by the device. The conceptual
1952
+ rows MUST NOT persist across MTA reboots.""",
1953
+ }, # row
1954
+ "pktcSigDevRingCadenceIndex" : {
1955
+ "nodetype" : "column",
1956
+ "moduleName" : "PKTC-IETF-SIG-MIB",
1957
+ "oid" : "1.3.6.1.2.1.169.1.1.31.1.1",
1958
+ "status" : "current",
1959
+ "syntax" : {
1960
+ "type" : {
1961
+ "basetype" : "Unsigned32",
1962
+ "ranges" : [
1963
+ {
1964
+ "min" : "0",
1965
+ "max" : "127"
1966
+ },
1967
+ ],
1968
+ "range" : {
1969
+ "min" : "0",
1970
+ "max" : "127"
1971
+ },
1972
+ },
1973
+ },
1974
+ "access" : "noaccess",
1975
+ "description" :
1976
+ """ A unique value ranging from 0 to 127 that corresponds to the
1977
+ value sent by the LE based on country-specific cadences,
1978
+ one row per cadence cycle. In any given system
1979
+ implementation for a particular country, it is anticipated
1980
+ that a small number of ring cadences will be in use. Thus,
1981
+ this table most likely will not be populated to its full
1982
+ size.""",
1983
+ }, # column
1984
+ "pktcSigDevRingCadence" : {
1985
+ "nodetype" : "column",
1986
+ "moduleName" : "PKTC-IETF-SIG-MIB",
1987
+ "oid" : "1.3.6.1.2.1.169.1.1.31.1.2",
1988
+ "status" : "current",
1989
+ "syntax" : {
1990
+ "type" : { "module" :"PKTC-IETF-SIG-MIB", "name" : "PktcRingCadence"},
1991
+ },
1992
+ "access" : "readwrite",
1993
+ "description" :
1994
+ """This is the Ring Cadence.""",
1995
+ }, # column
1996
+ "pktcSigDevToneTable" : {
1997
+ "nodetype" : "table",
1998
+ "moduleName" : "PKTC-IETF-SIG-MIB",
1999
+ "oid" : "1.3.6.1.2.1.169.1.1.32",
2000
+ "status" : "current",
2001
+ "description" :
2002
+ """ The Tone Table defines the composition of tones and
2003
+ various tone operations.
2004
+
2005
+ The definition of the tones callWaiting1 through
2006
+ callWaiting4 in this table MUST only contain the
2007
+ audible tone itself; the delay between tones or the value
2008
+ of the tone repeat count are not applicable for the call
2009
+ waiting tones.
2010
+
2011
+
2012
+
2013
+
2014
+ The delay between tones or the repeat count is controlled
2015
+ by the objects pktcSigEndPntConfigCallWaitingDelay and
2016
+ pktcSigEndPntConfigCallWaitingMaxRep. If the
2017
+ pktcSigDevToneType is set to either of the values
2018
+ callWaiting1, callWaiting2, callWaiting3, or callWaiting4,
2019
+ then the value of the pktcSigDevToneWholeToneRepeatCount
2020
+ object indicates that the particular frequency group is
2021
+ applicable, as a repeatable part of the tone, based on the
2022
+ value of the MIB object
2023
+ pktcSigDevToneWholeToneRepeatCount.
2024
+
2025
+ The MTA MUST make sure that, after the provisioning
2026
+ cycle, the table is fully populated (i.e., for each
2027
+ possible index, an entry MUST be defined) using
2028
+ reasonable defaults for each row that was not defined
2029
+ by the provisioning information delivered via MTA
2030
+ Configuration.
2031
+
2032
+ The frequency composition of each tone is defined by the
2033
+ pktcSigDevMultiFreqToneTable. For each tone type defined
2034
+ in pktcSigDevToneTable, the MTA MUST populate at least
2035
+ one entry in the pktcSigDevMultiFreqToneTable.
2036
+
2037
+ For each particular value of pktcSigDevToneType, the
2038
+ pktcSigDevToneTable table can define non-repeating and
2039
+ repeating groups of the frequencies defined by the
2040
+ pktcSigDevMultiFreqToneTable, such that each group is
2041
+ represented by the set of the consecutive rows
2042
+ (frequency group) in the pktcSigDevMultiFreqToneTable.
2043
+
2044
+ Objects in this table do not persist across MTA reboots.
2045
+ For tones with multiple frequencies refer to the MIB table
2046
+ pktcSigDevMultiFreqToneTable.""",
2047
+ "reference" :
2048
+ """PacketCable NCS Specification, ETSI-TS-101-909-4
2049
+ Specification.""",
2050
+ }, # table
2051
+ "pktcSigDevToneEntry" : {
2052
+ "nodetype" : "row",
2053
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2054
+ "oid" : "1.3.6.1.2.1.169.1.1.32.1",
2055
+ "status" : "current",
2056
+ "linkage" : [
2057
+ "pktcSigDevToneType",
2058
+ "pktcSigDevToneFreqGroup",
2059
+ ],
2060
+ "description" :
2061
+ """ The different tone types that can be provisioned based on
2062
+ country-specific needs.
2063
+
2064
+ Each entry contains the tone generation parameters for
2065
+ a specific frequency group of the specific Tone Type.
2066
+
2067
+
2068
+
2069
+ The different parameters can be provisioned via MTA
2070
+ configuration based on country specific needs.
2071
+ An MTA MUST populate all entries of this table for each
2072
+ tone type.""",
2073
+ }, # row
2074
+ "pktcSigDevToneType" : {
2075
+ "nodetype" : "column",
2076
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2077
+ "oid" : "1.3.6.1.2.1.169.1.1.32.1.1",
2078
+ "status" : "current",
2079
+ "syntax" : {
2080
+ "type" : {
2081
+ "basetype" : "Enumeration",
2082
+ "busy" : {
2083
+ "nodetype" : "namednumber",
2084
+ "number" : "1"
2085
+ },
2086
+ "confirmation" : {
2087
+ "nodetype" : "namednumber",
2088
+ "number" : "2"
2089
+ },
2090
+ "dial" : {
2091
+ "nodetype" : "namednumber",
2092
+ "number" : "3"
2093
+ },
2094
+ "messageWaiting" : {
2095
+ "nodetype" : "namednumber",
2096
+ "number" : "4"
2097
+ },
2098
+ "offHookWarning" : {
2099
+ "nodetype" : "namednumber",
2100
+ "number" : "5"
2101
+ },
2102
+ "ringBack" : {
2103
+ "nodetype" : "namednumber",
2104
+ "number" : "6"
2105
+ },
2106
+ "reOrder" : {
2107
+ "nodetype" : "namednumber",
2108
+ "number" : "7"
2109
+ },
2110
+ "stutterdial" : {
2111
+ "nodetype" : "namednumber",
2112
+ "number" : "8"
2113
+ },
2114
+ "callWaiting1" : {
2115
+ "nodetype" : "namednumber",
2116
+ "number" : "9"
2117
+ },
2118
+ "callWaiting2" : {
2119
+ "nodetype" : "namednumber",
2120
+ "number" : "10"
2121
+ },
2122
+ "callWaiting3" : {
2123
+ "nodetype" : "namednumber",
2124
+ "number" : "11"
2125
+ },
2126
+ "callWaiting4" : {
2127
+ "nodetype" : "namednumber",
2128
+ "number" : "12"
2129
+ },
2130
+ "alertingSignal" : {
2131
+ "nodetype" : "namednumber",
2132
+ "number" : "13"
2133
+ },
2134
+ "specialDial" : {
2135
+ "nodetype" : "namednumber",
2136
+ "number" : "14"
2137
+ },
2138
+ "specialInfo" : {
2139
+ "nodetype" : "namednumber",
2140
+ "number" : "15"
2141
+ },
2142
+ "release" : {
2143
+ "nodetype" : "namednumber",
2144
+ "number" : "16"
2145
+ },
2146
+ "congestion" : {
2147
+ "nodetype" : "namednumber",
2148
+ "number" : "17"
2149
+ },
2150
+ "userDefined1" : {
2151
+ "nodetype" : "namednumber",
2152
+ "number" : "18"
2153
+ },
2154
+ "userDefined2" : {
2155
+ "nodetype" : "namednumber",
2156
+ "number" : "19"
2157
+ },
2158
+ "userDefined3" : {
2159
+ "nodetype" : "namednumber",
2160
+ "number" : "20"
2161
+ },
2162
+ "userDefined4" : {
2163
+ "nodetype" : "namednumber",
2164
+ "number" : "21"
2165
+ },
2166
+ },
2167
+ },
2168
+ "access" : "noaccess",
2169
+ "description" :
2170
+ """A unique value that will correspond to the different
2171
+ tone types. These tones can be provisioned based on
2172
+ country-specific needs. This object defines the type
2173
+ of tone being accessed.
2174
+
2175
+ The alertingSignal, specialDial, specialInfo, release,
2176
+
2177
+
2178
+
2179
+ congestion, userDefined1, userDefined2, userDefined3,
2180
+ and userDefined4 tone types are used in
2181
+ the E line package.""",
2182
+ }, # column
2183
+ "pktcSigDevToneFreqGroup" : {
2184
+ "nodetype" : "column",
2185
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2186
+ "oid" : "1.3.6.1.2.1.169.1.1.32.1.2",
2187
+ "status" : "current",
2188
+ "syntax" : {
2189
+ "type" : {
2190
+ "basetype" : "Unsigned32",
2191
+ "ranges" : [
2192
+ {
2193
+ "min" : "1",
2194
+ "max" : "4"
2195
+ },
2196
+ ],
2197
+ "range" : {
2198
+ "min" : "1",
2199
+ "max" : "4"
2200
+ },
2201
+ },
2202
+ },
2203
+ "access" : "noaccess",
2204
+ "description" :
2205
+ """This MIB object represents the Tone Sequence reference
2206
+ of a multi-sequence tone.""",
2207
+ }, # column
2208
+ "pktcSigDevToneFreqCounter" : {
2209
+ "nodetype" : "column",
2210
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2211
+ "oid" : "1.3.6.1.2.1.169.1.1.32.1.3",
2212
+ "status" : "current",
2213
+ "syntax" : {
2214
+ "type" : {
2215
+ "basetype" : "Unsigned32",
2216
+ "ranges" : [
2217
+ {
2218
+ "min" : "1",
2219
+ "max" : "8"
2220
+ },
2221
+ ],
2222
+ "range" : {
2223
+ "min" : "1",
2224
+ "max" : "8"
2225
+ },
2226
+ },
2227
+ },
2228
+ "access" : "readonly",
2229
+ "description" :
2230
+ """This MIB object represents the number of consecutive
2231
+ multi-frequency tones for the particular tone type in
2232
+ the multi-frequency table (pktcSigDevMultiFreqToneTable).
2233
+
2234
+ Such a sequence of the consecutive multi-frequency tones
2235
+ forms the tone group for the particular tone type in the
2236
+ pktcSigDevToneTable.""",
2237
+ }, # column
2238
+ "pktcSigDevToneWholeToneRepeatCount" : {
2239
+ "nodetype" : "column",
2240
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2241
+ "oid" : "1.3.6.1.2.1.169.1.1.32.1.4",
2242
+ "status" : "current",
2243
+ "syntax" : {
2244
+ "type" : {
2245
+ "basetype" : "Unsigned32",
2246
+ "ranges" : [
2247
+ {
2248
+ "min" : "0",
2249
+ "max" : "5000"
2250
+ },
2251
+ ],
2252
+ "range" : {
2253
+ "min" : "0",
2254
+ "max" : "5000"
2255
+ },
2256
+ },
2257
+ },
2258
+ "access" : "readonly",
2259
+ "description" :
2260
+ """This is the repeat count, which signifies how many times
2261
+ to repeat the entire on-off cadence sequence. Setting this
2262
+ object may result in a cadence duration longer or shorter
2263
+ than the overall signal duration specified by the time out
2264
+ (TO) object for a particular signal. If the repeat count
2265
+ results in a longer tone duration than the signal duration
2266
+ specified by the TO, the tone duration defined by the
2267
+ TO object for a particular signal always represents
2268
+ the overall signal duration for a tone. In this case, the
2269
+ tone duration repeat count will not be fully exercised, and
2270
+ the desired tone duration will be truncated per the TO
2271
+ setting. If the repeat count results in a shorter tone
2272
+ duration than the signal duration specified by the TO, the
2273
+ tone duration defined by the repeat count takes precedence
2274
+ over the TO and will end the signal event. In this case,
2275
+
2276
+
2277
+
2278
+ the TO represents a time not to be exceeded for the signal.
2279
+ It is recommended to ensure proper telephony signaling so that
2280
+ the TO duration setting should always be longer than the
2281
+ desired repeat count-time duration.""",
2282
+ }, # column
2283
+ "pktcSigDevToneSteady" : {
2284
+ "nodetype" : "column",
2285
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2286
+ "oid" : "1.3.6.1.2.1.169.1.1.32.1.5",
2287
+ "status" : "current",
2288
+ "syntax" : {
2289
+ "type" : { "module" :"SNMPv2-TC", "name" : "TruthValue"},
2290
+ },
2291
+ "access" : "readonly",
2292
+ "description" :
2293
+ """This MIB object represents the steady tone status. A value
2294
+ of 'true(1)' indicates that the steady tone is applied, and
2295
+ a value of 'false(2)' indicates otherwise.
2296
+ Devices must play out the on-off cadence sequence for
2297
+ the number of times indicated by the MIB object
2298
+ 'pktcSigDevToneWholeToneRepeatCount' prior to applying the
2299
+ last tone steadily, indefinitely. If the MIB table
2300
+ 'pktcSigDevToneTable' contains multiple rows with this
2301
+ Object set to a value of 'true(1)', the steady tone is
2302
+ applied to the last repeating frequency group of the tone.
2303
+
2304
+ Setting this MIB object may result in a tone duration that is
2305
+ longer or shorter than the overall signal duration
2306
+ specified by the time out (TO) MIB object for a particular
2307
+ signal. If the repeat count results in a longer tone
2308
+ duration than the signal duration specified by the TO, the
2309
+ tone duration defined by the TO object for a particular
2310
+ signal always represents the overall signal duration for a
2311
+ tone. In this case, the tone duration repeat count will
2312
+ not be fully exercised, and the desired tone duration will
2313
+ be truncated per the TO setting. If the repeat count
2314
+ results in a shorter tone duration than the signal duration
2315
+ specified by the TO, the tone duration defined by the
2316
+ repeat count takes precedence over the TO and will end the
2317
+ signal event. In this case, the TO represents a time not to
2318
+ be exceeded for the signal.
2319
+
2320
+ It is recommended to ensure proper telephony signaling that
2321
+ The TO duration setting should always be longer than the
2322
+ desired repeat count-time duration, plus the desired maximum
2323
+ steady tone period.""",
2324
+ }, # column
2325
+ "pktcSigDevMultiFreqToneTable" : {
2326
+ "nodetype" : "table",
2327
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2328
+ "oid" : "1.3.6.1.2.1.169.1.1.33",
2329
+ "status" : "current",
2330
+ "description" :
2331
+ """ This MIB table defines the characteristics of tones
2332
+ with multiple frequencies. The constraints imposed
2333
+ on the tones by the MIB table pktcSigDevToneTable
2334
+ need to be considered for MIB objects in this table
2335
+ as well.
2336
+
2337
+ The MTA MUST populate the corresponding row(s)
2338
+ of the pktcSigDevMultiFreqToneTable for each tone
2339
+ defined in the pktcSigDevToneTable.
2340
+
2341
+ The contents of the table may be provisioned via
2342
+ MTA configuration.""",
2343
+ "reference" :
2344
+ """PacketCable NCS Specification, ETSI-TS-101-909-4
2345
+ Specification.""",
2346
+ }, # table
2347
+ "pktcSigDevMultiFreqToneEntry" : {
2348
+ "nodetype" : "row",
2349
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2350
+ "oid" : "1.3.6.1.2.1.169.1.1.33.1",
2351
+ "status" : "current",
2352
+ "linkage" : [
2353
+ "pktcSigDevToneType",
2354
+ "pktcSigDevToneNumber",
2355
+ ],
2356
+ "description" :
2357
+ """ The different tone types with multiple frequencies
2358
+ that can be provisioned based on country-specific
2359
+ needs.""",
2360
+ }, # row
2361
+ "pktcSigDevToneNumber" : {
2362
+ "nodetype" : "column",
2363
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2364
+ "oid" : "1.3.6.1.2.1.169.1.1.33.1.1",
2365
+ "status" : "current",
2366
+ "syntax" : {
2367
+ "type" : {
2368
+ "basetype" : "Unsigned32",
2369
+ "ranges" : [
2370
+ {
2371
+ "min" : "1",
2372
+ "max" : "8"
2373
+ },
2374
+ ],
2375
+ "range" : {
2376
+ "min" : "1",
2377
+ "max" : "8"
2378
+ },
2379
+ },
2380
+ },
2381
+ "access" : "noaccess",
2382
+ "description" :
2383
+ """This MIB object represents the frequency reference
2384
+ of a multi-frequency tone.""",
2385
+ }, # column
2386
+ "pktcSigDevToneFirstFreqValue" : {
2387
+ "nodetype" : "column",
2388
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2389
+ "oid" : "1.3.6.1.2.1.169.1.1.33.1.2",
2390
+ "status" : "current",
2391
+ "syntax" : {
2392
+ "type" : {
2393
+ "basetype" : "Unsigned32",
2394
+ "ranges" : [
2395
+ {
2396
+ "min" : "0",
2397
+ "max" : "4000"
2398
+ },
2399
+ ],
2400
+ "range" : {
2401
+ "min" : "0",
2402
+ "max" : "4000"
2403
+ },
2404
+ },
2405
+ },
2406
+ "access" : "readonly",
2407
+ "description" :
2408
+ """This MIB object represents the value of the first
2409
+ frequency of a tone type. A value of zero implies
2410
+ absence of the referenced frequency.""",
2411
+ }, # column
2412
+ "pktcSigDevToneSecondFreqValue" : {
2413
+ "nodetype" : "column",
2414
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2415
+ "oid" : "1.3.6.1.2.1.169.1.1.33.1.3",
2416
+ "status" : "current",
2417
+ "syntax" : {
2418
+ "type" : {
2419
+ "basetype" : "Unsigned32",
2420
+ "ranges" : [
2421
+ {
2422
+ "min" : "0",
2423
+ "max" : "4000"
2424
+ },
2425
+ ],
2426
+ "range" : {
2427
+ "min" : "0",
2428
+ "max" : "4000"
2429
+ },
2430
+ },
2431
+ },
2432
+ "access" : "readonly",
2433
+ "description" :
2434
+ """This MIB object represents the value of the second
2435
+ frequency of a tone type. A value of zero implies
2436
+ absence of the referenced frequency.""",
2437
+ }, # column
2438
+ "pktcSigDevToneThirdFreqValue" : {
2439
+ "nodetype" : "column",
2440
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2441
+ "oid" : "1.3.6.1.2.1.169.1.1.33.1.4",
2442
+ "status" : "current",
2443
+ "syntax" : {
2444
+ "type" : {
2445
+ "basetype" : "Unsigned32",
2446
+ "ranges" : [
2447
+ {
2448
+ "min" : "0",
2449
+ "max" : "4000"
2450
+ },
2451
+ ],
2452
+ "range" : {
2453
+ "min" : "0",
2454
+ "max" : "4000"
2455
+ },
2456
+ },
2457
+ },
2458
+ "access" : "readonly",
2459
+ "description" :
2460
+ """This MIB object represents the value of the third
2461
+ frequency of a tone type. A value of zero implies
2462
+ absence of the referenced frequency.""",
2463
+ }, # column
2464
+ "pktcSigDevToneFourthFreqValue" : {
2465
+ "nodetype" : "column",
2466
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2467
+ "oid" : "1.3.6.1.2.1.169.1.1.33.1.5",
2468
+ "status" : "current",
2469
+ "syntax" : {
2470
+ "type" : {
2471
+ "basetype" : "Unsigned32",
2472
+ "ranges" : [
2473
+ {
2474
+ "min" : "0",
2475
+ "max" : "4000"
2476
+ },
2477
+ ],
2478
+ "range" : {
2479
+ "min" : "0",
2480
+ "max" : "4000"
2481
+ },
2482
+ },
2483
+ },
2484
+ "access" : "readonly",
2485
+ "description" :
2486
+ """This MIB object represents the value of the fourth
2487
+ frequency of a tone type. A value of zero implies
2488
+ absence of the referenced frequency.""",
2489
+ }, # column
2490
+ "pktcSigDevToneFreqMode" : {
2491
+ "nodetype" : "column",
2492
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2493
+ "oid" : "1.3.6.1.2.1.169.1.1.33.1.6",
2494
+ "status" : "current",
2495
+ "syntax" : {
2496
+ "type" : {
2497
+ "basetype" : "Enumeration",
2498
+ "firstModulatedBySecond" : {
2499
+ "nodetype" : "namednumber",
2500
+ "number" : "1"
2501
+ },
2502
+ "summation" : {
2503
+ "nodetype" : "namednumber",
2504
+ "number" : "2"
2505
+ },
2506
+ },
2507
+ },
2508
+ "access" : "readonly",
2509
+ "description" :
2510
+ """This MIB object provides directive on the
2511
+ modulation or summation of the frequencies
2512
+ involved in the tone.
2513
+
2514
+ It is to be noted that while summation can
2515
+ be done without any constraint on the number
2516
+ of frequencies, the modulation (amplitude)
2517
+ holds good only when there are two frequencies
2518
+ (first and second).
2519
+
2520
+ Thus:
2521
+ - If the mode is set to a value of
2522
+ 'firstModulatedBySecond(1)', the first frequency
2523
+ MUST be modulated by the second, and the remaining
2524
+ frequencies (third and fourth) ignored. The
2525
+ percentage of amplitude modulation to be applied
2526
+ is defined by the MIB object
2527
+ pktcSigDevToneFreqAmpModePrtg.
2528
+
2529
+ - If the mode is set to a value of
2530
+ 'summation(2)', all the frequencies MUST be
2531
+ summed without any modulation.""",
2532
+ }, # column
2533
+ "pktcSigDevToneFreqAmpModePrtg" : {
2534
+ "nodetype" : "column",
2535
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2536
+ "oid" : "1.3.6.1.2.1.169.1.1.33.1.7",
2537
+ "status" : "current",
2538
+ "syntax" : {
2539
+ "type" : {
2540
+ "basetype" : "Unsigned32",
2541
+ "ranges" : [
2542
+ {
2543
+ "min" : "0",
2544
+ "max" : "100"
2545
+ },
2546
+ ],
2547
+ "range" : {
2548
+ "min" : "0",
2549
+ "max" : "100"
2550
+ },
2551
+ },
2552
+ },
2553
+ "access" : "readonly",
2554
+ "description" :
2555
+ """This MIB object represents the percentage of amplitude
2556
+ modulation applied to the second frequency
2557
+ when the MIB object pktcSigDevToneFreqMode is
2558
+ set to a value of 'firstModulatedBySecond (1)'.
2559
+
2560
+ If the MIB object pktcSigDevToneFreqMode is set to
2561
+ value of 'summation (2)', then this MIB object MUST be
2562
+ ignored.""",
2563
+ }, # column
2564
+ "pktcSigDevToneDbLevel" : {
2565
+ "nodetype" : "column",
2566
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2567
+ "oid" : "1.3.6.1.2.1.169.1.1.33.1.8",
2568
+ "status" : "current",
2569
+ "syntax" : {
2570
+ "type" : {
2571
+ "basetype" : "Integer32",
2572
+ "parent module" : {
2573
+ "name" : "PKTC-IETF-SIG-MIB",
2574
+ "type" : "TenthdBm",
2575
+ },
2576
+ "ranges" : [
2577
+ {
2578
+ "min" : "-250",
2579
+ "max" : "-110"
2580
+ },
2581
+ ],
2582
+ "range" : {
2583
+ "min" : "-250",
2584
+ "max" : "-110"
2585
+ },
2586
+ },
2587
+ },
2588
+ "access" : "readonly",
2589
+ "default" : "-120",
2590
+ "units" : "1/10 of a dBm",
2591
+ "description" :
2592
+ """This MIB object contains the decibel level for each
2593
+ analog signal (tone) that is locally generated
2594
+ (versus in-band supervisory tones) and sourced to
2595
+ the a-b terminals (TE connection point). Each tone
2596
+ in itself may consist of multiple frequencies, as
2597
+ defined by the MIB table pktcSigDevMultiFreqToneTable.
2598
+
2599
+ This MIB object reflects the desired level at
2600
+ the Telco (POTS) a-b (T/R) terminals, including the
2601
+ effect of any MTA receiver gain (loss). This is required
2602
+ so that locally generated tones are consistent with
2603
+ remotely generated in-band tones at the a-b terminals,
2604
+ consistent with user expectations.
2605
+
2606
+ This MIB object must be set for each tone.
2607
+ When tones are formed by combining multi-frequencies,
2608
+ the level of each frequency shall be set so as to result
2609
+ in the tone level specified in this object at the a-b
2610
+ (T/R) terminals.
2611
+
2612
+ The wide range of levels for this Object is required
2613
+ to provide signal-generator levels across the wide
2614
+ range of gains (losses) -- but does not imply the entire
2615
+ range is to be achievable given the range of gains (losses)
2616
+ in the MTA.""",
2617
+ }, # column
2618
+ "pktcSigDevToneFreqOnDuration" : {
2619
+ "nodetype" : "column",
2620
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2621
+ "oid" : "1.3.6.1.2.1.169.1.1.33.1.9",
2622
+ "status" : "current",
2623
+ "syntax" : {
2624
+ "type" : {
2625
+ "basetype" : "Unsigned32",
2626
+ "ranges" : [
2627
+ {
2628
+ "min" : "0",
2629
+ "max" : "5000"
2630
+ },
2631
+ ],
2632
+ "range" : {
2633
+ "min" : "0",
2634
+ "max" : "5000"
2635
+ },
2636
+ },
2637
+ },
2638
+ "access" : "readonly",
2639
+ "units" : "milliseconds",
2640
+ "description" :
2641
+ """This MIB object represents the duration for which the
2642
+ frequency reference corresponding to the tone type
2643
+ is turned on.""",
2644
+ }, # column
2645
+ "pktcSigDevToneFreqOffDuration" : {
2646
+ "nodetype" : "column",
2647
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2648
+ "oid" : "1.3.6.1.2.1.169.1.1.33.1.10",
2649
+ "status" : "current",
2650
+ "syntax" : {
2651
+ "type" : {
2652
+ "basetype" : "Unsigned32",
2653
+ "ranges" : [
2654
+ {
2655
+ "min" : "0",
2656
+ "max" : "5000"
2657
+ },
2658
+ ],
2659
+ "range" : {
2660
+ "min" : "0",
2661
+ "max" : "5000"
2662
+ },
2663
+ },
2664
+ },
2665
+ "access" : "readonly",
2666
+ "units" : "milliseconds",
2667
+ "description" :
2668
+ """This MIB object represents the duration for which the
2669
+
2670
+
2671
+
2672
+ frequency reference corresponding to the tone type
2673
+ is turned off.""",
2674
+ }, # column
2675
+ "pktcSigDevToneFreqRepeatCount" : {
2676
+ "nodetype" : "column",
2677
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2678
+ "oid" : "1.3.6.1.2.1.169.1.1.33.1.11",
2679
+ "status" : "current",
2680
+ "syntax" : {
2681
+ "type" : {
2682
+ "basetype" : "Unsigned32",
2683
+ "ranges" : [
2684
+ {
2685
+ "min" : "0",
2686
+ "max" : "5000"
2687
+ },
2688
+ ],
2689
+ "range" : {
2690
+ "min" : "0",
2691
+ "max" : "5000"
2692
+ },
2693
+ },
2694
+ },
2695
+ "access" : "readonly",
2696
+ "description" :
2697
+ """This MIB object indicates the number of times
2698
+ to repeat the cadence cycle represented by the
2699
+ on/off durations (refer to the MIB objects
2700
+ pktcSigDevToneFreqOnDuration and
2701
+ pktcSigDevToneFreqOffDuration).
2702
+
2703
+ Setting this object may result in a tone duration that is
2704
+ longer or shorter than the overall signal duration
2705
+ specified by the time out (TO) object for the
2706
+ corresponding tone type. If the value of this MIB
2707
+ Object indicates a longer duration than that
2708
+ specified by the TO, the latter overrules the former,
2709
+ and the desired tone duration will be truncated according
2710
+ to the TO.
2711
+
2712
+ However, if the repeat count results in a shorter
2713
+ tone duration than the signal duration specified by
2714
+ the TO, the tone duration defined by the repeat count
2715
+ takes precedence over the TO and will end the signal
2716
+ event. In this case, the TO represents a time not to
2717
+ be exceeded for the signal. It is recommended, to
2718
+ ensure proper telephony signaling, that the TO
2719
+ duration setting should always be longer than the
2720
+ desired repeat count-time duration. A value of zero
2721
+ means the tone sequence is to be played once but not
2722
+ repeated.""",
2723
+ }, # column
2724
+ "pktcSigDevCidDelayAfterLR" : {
2725
+ "nodetype" : "scalar",
2726
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2727
+ "oid" : "1.3.6.1.2.1.169.1.1.34",
2728
+ "status" : "current",
2729
+ "syntax" : {
2730
+ "type" : {
2731
+ "basetype" : "Unsigned32",
2732
+ "ranges" : [
2733
+ {
2734
+ "min" : "300",
2735
+ "max" : "800"
2736
+ },
2737
+ ],
2738
+ "range" : {
2739
+ "min" : "300",
2740
+ "max" : "800"
2741
+ },
2742
+ },
2743
+ },
2744
+ "access" : "readwrite",
2745
+ "default" : "400",
2746
+ "units" : "Milliseconds",
2747
+ "description" :
2748
+ """This object specifies the delay between the end of the
2749
+ Line Reversal and the start of the FSK or DTMF signal.
2750
+ This MIB object is used only when pktcSigDevCidMode is
2751
+ set to a value of 'lrETS'. This timing has a range of
2752
+ 300 to 800 ms.
2753
+
2754
+
2755
+
2756
+ The following table defines the default values
2757
+ for this MIB object, depending on the signal type
2758
+ (pktcSigDevCidMode), and MUST be followed:
2759
+
2760
+ Value of pktcSigDevCidMode Default value
2761
+
2762
+ duringringingETS any value (not used)
2763
+ dtAsETS any value (not used)
2764
+ rpAsETS any value (not used)
2765
+ lrAsETS any value (not used)
2766
+ lrETS 400
2767
+
2768
+ An attempt to set this object while the value of
2769
+ pktcSigDevCidMode is not set to a value of 'lrETS' will
2770
+ result in an 'inconsistentValue' error.
2771
+
2772
+ The value of this MIB object MUST NOT persist across MTA
2773
+ reboots.""",
2774
+ }, # scalar
2775
+ "pktcSigDevCidDtmfStartCode" : {
2776
+ "nodetype" : "scalar",
2777
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2778
+ "oid" : "1.3.6.1.2.1.169.1.1.35",
2779
+ "status" : "current",
2780
+ "syntax" : {
2781
+ "type" : { "module" :"PKTC-IETF-SIG-MIB", "name" : "DtmfCode"},
2782
+ },
2783
+ "access" : "readwrite",
2784
+ "default" : "dtmfcodeA",
2785
+ "description" :
2786
+ """This object identifies optional start codes used when
2787
+ the MIB object pktcSigDevCidSigProtocol is set
2788
+ to a value of 'dtmf(2)'.
2789
+
2790
+ Different countries define different caller id signaling
2791
+ codes to support caller identification. When Dual-Tone
2792
+ Multi-Frequency (DTMF) is used, the caller id digits are
2793
+ preceded by a 'start code' digit, followed by the digit
2794
+ transmission sequence <S1>...<Sn> (where Sx represents
2795
+ the digits 0-9), and terminated by the 'end code' digit.
2796
+
2797
+ For example,
2798
+ <A><S1>...<Sn> <D><S1>...<Sn> <B><S1>...<Sn> <C>.
2799
+ The start code for calling number delivery may be DTMF
2800
+ 'A' or 'D'. The start code for redirecting a number may be
2801
+ DTMF 'D'. The DTMF code 'B' may be sent by the network
2802
+ as a start code for the transfer of information values,
2803
+ through which special events can be indicated to the
2804
+ user. In some countries, the '*' or '#' may be used
2805
+ instead of 'A', 'B', 'C', or 'D'.
2806
+
2807
+ The value of this MIB object MUST NOT persist across MTA
2808
+
2809
+
2810
+
2811
+ reboots.""",
2812
+ "reference" :
2813
+ """ETSI-EN-300-659-1 specification""",
2814
+ }, # scalar
2815
+ "pktcSigDevCidDtmfEndCode" : {
2816
+ "nodetype" : "scalar",
2817
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2818
+ "oid" : "1.3.6.1.2.1.169.1.1.36",
2819
+ "status" : "current",
2820
+ "syntax" : {
2821
+ "type" : { "module" :"PKTC-IETF-SIG-MIB", "name" : "DtmfCode"},
2822
+ },
2823
+ "access" : "readwrite",
2824
+ "default" : "dtmfcodeC",
2825
+ "description" :
2826
+ """This object identifies optional end codes used when the
2827
+ pktcSigDevCidSigProtocol is set to a value of
2828
+ 'dtmf(2)'.
2829
+
2830
+ Different countries define different caller id signaling
2831
+ protocols to support caller identification. When
2832
+ Dual-Tone Multi-Frequency (DTMF) is used, the caller id
2833
+ digits are preceded by a 'start code' digit, followed by
2834
+ the digit transmission sequence <S1>...<Sn> (where Sx
2835
+ represents the digits 0-9), and terminated by the 'end
2836
+ code' digit.
2837
+
2838
+ For example,
2839
+ <A><S1>...<Sn> <D><S1>...<Sn> <B><S1>...<Sn> <C>.
2840
+
2841
+ The DTMF code 'C' may be sent by the network as an
2842
+ end code for the transfer of information values, through
2843
+ which special events can be indicated to the user. In
2844
+ some countries, the '*' or '#' may be used instead of
2845
+ 'A', 'B', 'C', or 'D'.
2846
+
2847
+ The value of this MIB object MUST NOT persist across MTA
2848
+ reboots.""",
2849
+ "reference" :
2850
+ """ETSI-EN-300-659-1 specification""",
2851
+ }, # scalar
2852
+ "pktcSigDevVmwiSigProtocol" : {
2853
+ "nodetype" : "scalar",
2854
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2855
+ "oid" : "1.3.6.1.2.1.169.1.1.37",
2856
+ "status" : "current",
2857
+ "syntax" : {
2858
+ "type" : { "module" :"PKTC-IETF-SIG-MIB", "name" : "PktcSubscriberSideSigProtocol"},
2859
+ },
2860
+ "access" : "readwrite",
2861
+ "default" : "fsk",
2862
+ "description" :
2863
+ """This object identifies the subscriber line protocol used
2864
+ for signaling the information on Visual Message Waiting
2865
+ Indicator (VMWI). Different countries define different
2866
+ VMWI signaling protocols to support VMWI service.
2867
+
2868
+
2869
+
2870
+ Frequency shift keying (FSK) is most commonly used.
2871
+ DTMF is an alternative.
2872
+
2873
+ The value of this MIB object MUST NOT persist across MTA
2874
+ reboots.""",
2875
+ }, # scalar
2876
+ "pktcSigDevVmwiDelayAfterLR" : {
2877
+ "nodetype" : "scalar",
2878
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2879
+ "oid" : "1.3.6.1.2.1.169.1.1.38",
2880
+ "status" : "current",
2881
+ "syntax" : {
2882
+ "type" : {
2883
+ "basetype" : "Unsigned32",
2884
+ "ranges" : [
2885
+ {
2886
+ "min" : "0",
2887
+ "max" : "0"
2888
+ },
2889
+ {
2890
+ "min" : "300",
2891
+ "max" : "800"
2892
+ },
2893
+ ],
2894
+ "range" : {
2895
+ "min" : "0",
2896
+ "max" : "800"
2897
+ },
2898
+ },
2899
+ },
2900
+ "access" : "readwrite",
2901
+ "default" : "400",
2902
+ "units" : "Milliseconds",
2903
+ "description" :
2904
+ """This object specifies the delay between the end of the
2905
+ Line Reversal and the start of the FSK or DTMF signal.
2906
+ This object is only used when pktcSigDevVmwiMode is
2907
+ set to a value of 'lrETS'.
2908
+ This timing has a range of 300 to 800 ms.
2909
+
2910
+ The following table defines the default values
2911
+ for this MIB object, depending on the signal type
2912
+ (pktcSigDevVmwiMode), and MUST be followed:
2913
+
2914
+ Value of pktcSigDevVmwiMode Default value
2915
+
2916
+ duringringingETS any value (not used)
2917
+ dtAsETS any value (not used)
2918
+ rpAsETS any value (not used)
2919
+ lrAsETS any value (not used)
2920
+ lrETS 400
2921
+
2922
+ An attempt to set this object while the value of
2923
+ pktcSigDevVmwiMode is not 'lrETS' will result in an
2924
+ 'inconsistentValue' error.
2925
+
2926
+ The value of this MIB object MUST NOT persist across MTA
2927
+ reboots.""",
2928
+ }, # scalar
2929
+ "pktcSigDevVmwiDtmfStartCode" : {
2930
+ "nodetype" : "scalar",
2931
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2932
+ "oid" : "1.3.6.1.2.1.169.1.1.39",
2933
+ "status" : "current",
2934
+ "syntax" : {
2935
+ "type" : { "module" :"PKTC-IETF-SIG-MIB", "name" : "DtmfCode"},
2936
+ },
2937
+ "access" : "readwrite",
2938
+ "default" : "dtmfcodeA",
2939
+ "description" :
2940
+ """This object identifies optional start codes used when
2941
+
2942
+
2943
+
2944
+ the pktcSigDevVmwiSigProtocol is set to a value of
2945
+ 'dtmf(2)'. Different countries define different On Hook
2946
+ Data Transmission Protocol signaling codes to support
2947
+ VMWI.
2948
+
2949
+ When Dual-Tone Multi-Frequency (DTMF) is used, the VMWI
2950
+ digits are preceded by a 'start code' digit, followed
2951
+ by the digit transmission sequence <S1>...<Sn> (where
2952
+ Sx represents the digits 0-9), and terminated by the 'end
2953
+ code' digit.
2954
+
2955
+ For example,
2956
+ <A><S1>...<Sn> <D><S1>...<Sn> <B><S1>...<Sn> <C>.
2957
+
2958
+ The start code for redirecting VMWI may be DTMF 'D'
2959
+ The DTMF code 'B' may be sent by the network as a start
2960
+ code for the transfer of information values, through
2961
+ which special events can be indicated to the user. In
2962
+ some countries, the '*' or '#' may be used instead of
2963
+ 'A', 'B', 'C', or 'D'.
2964
+
2965
+ The value of this MIB object MUST NOT persist across MTA
2966
+ reboots.""",
2967
+ "reference" :
2968
+ """ETSI-EN-300-659-1 specification""",
2969
+ }, # scalar
2970
+ "pktcSigDevVmwiDtmfEndCode" : {
2971
+ "nodetype" : "scalar",
2972
+ "moduleName" : "PKTC-IETF-SIG-MIB",
2973
+ "oid" : "1.3.6.1.2.1.169.1.1.40",
2974
+ "status" : "current",
2975
+ "syntax" : {
2976
+ "type" : { "module" :"PKTC-IETF-SIG-MIB", "name" : "DtmfCode"},
2977
+ },
2978
+ "access" : "readwrite",
2979
+ "default" : "dtmfcodeC",
2980
+ "description" :
2981
+ """This object identifies an optional end code used when the
2982
+ pktcSigDevVmwiSigProtocol is set to a value of
2983
+ 'dtmf(2)'. Different countries define different on-hook
2984
+ Data Transmission Protocol signaling codes to support
2985
+ VMWI.
2986
+
2987
+ When Dual-Tone Multi-Frequency (DTMF) is used, the VMWI
2988
+ digits are preceded by a 'start code' digit, followed
2989
+ by the digit transmission sequence <S1>...<Sn> (where
2990
+ Sx represents the digits 0-9), and terminated by the 'end
2991
+ code' digit.
2992
+
2993
+ For example,
2994
+ <A><S1>...<Sn> <D><S1>...<Sn> <B><S1>...<Sn> <C>.
2995
+
2996
+
2997
+
2998
+
2999
+ The DTMF code 'C' may be sent by the network as an end code
3000
+ for the transfer of information values, through which
3001
+ special events can be indicated to the user. In some
3002
+ countries, the '*' or '#' may be used instead of 'A',
3003
+ 'B', 'C', or 'D'.
3004
+
3005
+ The value of this MIB object MUST NOT persist across MTA
3006
+ reboots.""",
3007
+ "reference" :
3008
+ """ETSI-EN-300-659-1 specification""",
3009
+ }, # scalar
3010
+ "pktcSigDevrpAsDtsDuration" : {
3011
+ "nodetype" : "scalar",
3012
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3013
+ "oid" : "1.3.6.1.2.1.169.1.1.41",
3014
+ "status" : "current",
3015
+ "syntax" : {
3016
+ "type" : {
3017
+ "basetype" : "Unsigned32",
3018
+ "ranges" : [
3019
+ {
3020
+ "min" : "0",
3021
+ "max" : "0"
3022
+ },
3023
+ {
3024
+ "min" : "200",
3025
+ "max" : "500"
3026
+ },
3027
+ ],
3028
+ "range" : {
3029
+ "min" : "0",
3030
+ "max" : "500"
3031
+ },
3032
+ },
3033
+ },
3034
+ "access" : "readwrite",
3035
+ "default" : "250",
3036
+ "units" : "Milliseconds",
3037
+ "description" :
3038
+ """ This object specifies the duration of the rpASDTS ring
3039
+ pulse prior to the start of the transmission of the
3040
+ FSK or DTMF containing the caller id information. It is
3041
+ only used when pktcSigDevCidMode is set to a value of
3042
+ 'rpAsETS'.
3043
+
3044
+ The following table defines the default values
3045
+ for this MIB object, depending on the signal type
3046
+ (pktcSigDevCidMode), and MUST be followed:
3047
+
3048
+ Value of pktcSigDevCidMode Default value
3049
+
3050
+ duringringingETS any value (not used)
3051
+ dtAsETS any value (not used)
3052
+ rpAsETS 250
3053
+ lrAsETS any value (not used)
3054
+ lrETS any value (not used)
3055
+
3056
+ An attempt to set this object while the value of
3057
+ pktcSigDevCidMode is not 'rpAsETS' will result in
3058
+ an 'inconsistentValue' error.
3059
+
3060
+ The value of this MIB object MUST NOT persist across MTA
3061
+ reboots.""",
3062
+ "reference" :
3063
+ """ETSI-EN-300-659-1 Specification and Belgacom
3064
+ BGC_D_48_9811_30_09_EDOC version 3.3""",
3065
+ }, # scalar
3066
+ "pktcSigEndPntConfigObjects" : {
3067
+ "nodetype" : "node",
3068
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3069
+ "oid" : "1.3.6.1.2.1.169.1.2",
3070
+ }, # node
3071
+ "pktcSigEndPntConfigTable" : {
3072
+ "nodetype" : "table",
3073
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3074
+ "oid" : "1.3.6.1.2.1.169.1.2.1",
3075
+ "status" : "current",
3076
+ "description" :
3077
+ """ This table describes the information pertaining to each
3078
+ endpoint of the MTA. All entries in this table represent
3079
+ the provisioned endpoints provisioned with the information
3080
+ required by the MTA to maintain the NCS protocol
3081
+ communication with the CMS. Each endpoint can be assigned
3082
+ to its own CMS. If the specific endpoint does not have
3083
+ the corresponding CMS information in this table, the
3084
+ endpoint is considered as not provisioned with voice
3085
+ services. Objects in this table do not persist across
3086
+ MTA reboots.""",
3087
+ }, # table
3088
+ "pktcSigEndPntConfigEntry" : {
3089
+ "nodetype" : "row",
3090
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3091
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1",
3092
+ "create" : "true",
3093
+ "status" : "current",
3094
+ "linkage" : [
3095
+ "ifIndex",
3096
+ ],
3097
+ "description" :
3098
+ """Each entry in the pktcSigEndPntConfigTable represents
3099
+ required signaling parameters for the specific endpoint
3100
+ provisioned with voice services. The conceptual rows MUST
3101
+ NOT persist across MTA reboots.""",
3102
+ }, # row
3103
+ "pktcSigEndPntConfigCallAgentId" : {
3104
+ "nodetype" : "column",
3105
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3106
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.1",
3107
+ "status" : "current",
3108
+ "syntax" : {
3109
+ "type" : {
3110
+ "basetype" : "OctetString",
3111
+ "parent module" : {
3112
+ "name" : "SNMP-FRAMEWORK-MIB",
3113
+ "type" : "SnmpAdminString",
3114
+ },
3115
+ "ranges" : [
3116
+ {
3117
+ "min" : "3",
3118
+ "max" : "255"
3119
+ },
3120
+ ],
3121
+ "range" : {
3122
+ "min" : "3",
3123
+ "max" : "255"
3124
+ },
3125
+ },
3126
+ },
3127
+ "access" : "readwrite",
3128
+ "description" :
3129
+ """ This object contains a string indicating the call agent
3130
+ name (e.g., ca@example.com). The call agent name, after
3131
+ the character '@', MUST be a fully qualified domain name
3132
+ (FQDN) and MUST have a corresponding pktcMtaDevCmsFqdn
3133
+ entry in the pktcMtaDevCmsTable. The object
3134
+ pktcMtaDevCmsFqdn is defined in the PacketCable MIBMTA
3135
+ Specification. For each particular endpoint, the MTA MUST
3136
+ use the current value of this object to communicate with
3137
+ the corresponding CMS. The MTA MUST update this object
3138
+ with the value of the 'Notified Entity' parameter of the
3139
+ NCS message. Because of the high importance of this object
3140
+ to the ability of the MTA to maintain reliable NCS
3141
+ communication with the CMS, it is highly recommended not
3142
+ to change this object's value using SNMP during normal
3143
+ operation.""",
3144
+ }, # column
3145
+ "pktcSigEndPntConfigCallAgentUdpPort" : {
3146
+ "nodetype" : "column",
3147
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3148
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.2",
3149
+ "status" : "current",
3150
+ "syntax" : {
3151
+ "type" : {
3152
+ "basetype" : "Unsigned32",
3153
+ "parent module" : {
3154
+ "name" : "INET-ADDRESS-MIB",
3155
+ "type" : "InetPortNumber",
3156
+ },
3157
+ "ranges" : [
3158
+ {
3159
+ "min" : "1025",
3160
+ "max" : "65535"
3161
+ },
3162
+ ],
3163
+ "range" : {
3164
+ "min" : "1025",
3165
+ "max" : "65535"
3166
+ },
3167
+ },
3168
+ },
3169
+ "access" : "readwrite",
3170
+ "default" : "2727",
3171
+ "description" :
3172
+ """ This object contains the current value of the User
3173
+ Datagram Protocol (UDP) receive port on which the
3174
+ call agent will receive NCS from the endpoint.
3175
+ For each particular endpoint, the MTA MUST use the current
3176
+ value of this object to communicate with the corresponding
3177
+ CMS. The MTA MUST update this object with the value of the
3178
+ 'Notified Entity' parameter of the NCS message. If the
3179
+ Notified Entity parameter does not contain a CallAgent
3180
+ port, the MTA MUST update this object with the default
3181
+ value of 2727. Because of the high importance of this
3182
+ object to the ability of the MTA to maintain reliable NCS
3183
+ communication with the CMS, it is highly recommended not
3184
+ to change this object's value using SNMP during normal
3185
+ operation.""",
3186
+ "reference" :
3187
+ """PacketCable NCS Specification""",
3188
+ }, # column
3189
+ "pktcSigEndPntConfigPartialDialTO" : {
3190
+ "nodetype" : "column",
3191
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3192
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.3",
3193
+ "status" : "current",
3194
+ "syntax" : {
3195
+ "type" : { "module" :"", "name" : "Unsigned32"},
3196
+ },
3197
+ "access" : "readwrite",
3198
+ "default" : "16",
3199
+ "units" : "seconds",
3200
+ "description" :
3201
+ """This object contains the value of the partial dial
3202
+ time out.
3203
+ The time out (TO) elements are intended to limit the time a
3204
+ tone or frequency is generated. When this MIB object is set
3205
+ to a value of '0', the MTA MUST NOT generate the
3206
+ corresponding frequency or tone, regardless of the
3207
+ definitions pertaining to frequency, tone duration, or
3208
+ cadence.""",
3209
+ "reference" :
3210
+ """PacketCable NCS Specification""",
3211
+ }, # column
3212
+ "pktcSigEndPntConfigCriticalDialTO" : {
3213
+ "nodetype" : "column",
3214
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3215
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.4",
3216
+ "status" : "current",
3217
+ "syntax" : {
3218
+ "type" : { "module" :"", "name" : "Unsigned32"},
3219
+ },
3220
+ "access" : "readwrite",
3221
+ "default" : "4",
3222
+ "units" : "seconds",
3223
+ "description" :
3224
+ """This object contains the value of the critical
3225
+ dial time out.
3226
+ The time out (TO) elements are intended to limit the time a
3227
+ tone or frequency is generated. When this MIB object is set
3228
+ to a value of '0', the MTA MUST NOT generate the
3229
+ corresponding frequency or tone, regardless of the
3230
+ definitions pertaining to frequency, tone duration, or
3231
+ cadence.""",
3232
+ "reference" :
3233
+ """PacketCable NCS Specification""",
3234
+ }, # column
3235
+ "pktcSigEndPntConfigBusyToneTO" : {
3236
+ "nodetype" : "column",
3237
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3238
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.5",
3239
+ "status" : "current",
3240
+ "syntax" : {
3241
+ "type" : { "module" :"", "name" : "Unsigned32"},
3242
+ },
3243
+ "access" : "readwrite",
3244
+ "default" : "30",
3245
+ "units" : "seconds",
3246
+ "description" :
3247
+ """ This object contains the default time out value for busy
3248
+ tone. The MTA MUST NOT update this object with the
3249
+ value provided in the NCS message (if present). If
3250
+ the value of the object is modified by the SNMP Management
3251
+ Station, the MTA MUST use the new value as a default only
3252
+ for a new signal requested by the NCS message.
3253
+ The time out (TO) elements are intended to limit the time
3254
+ a tone or frequency is generated. When this MIB object is
3255
+ set to a value of '0', the MTA MUST NOT generate the
3256
+ corresponding frequency or tone, regardless of the
3257
+ definitions pertaining to frequency, tone duration, or
3258
+ cadence.""",
3259
+ "reference" :
3260
+ """PacketCable NCS Specification""",
3261
+ }, # column
3262
+ "pktcSigEndPntConfigDialToneTO" : {
3263
+ "nodetype" : "column",
3264
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3265
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.6",
3266
+ "status" : "current",
3267
+ "syntax" : {
3268
+ "type" : { "module" :"", "name" : "Unsigned32"},
3269
+ },
3270
+ "access" : "readwrite",
3271
+ "default" : "16",
3272
+ "units" : "seconds",
3273
+ "description" :
3274
+ """ This object contains the default time out value for dial
3275
+ tone. The MTA MUST NOT update this object with the
3276
+ value provided in the NCS message (if present). If
3277
+
3278
+
3279
+
3280
+ the value of the object is modified by the SNMP Management
3281
+ Station, the MTA MUST use the new value as a default only
3282
+ for a new signal requested by the NCS message.
3283
+ The time out (TO) elements are intended to limit the time
3284
+ a tone or frequency is generated. When this MIB object is
3285
+ set to a value of '0', the MTA MUST NOT generate the
3286
+ corresponding frequency or tone, regardless of the
3287
+ definitions pertaining to frequency, tone duration, or
3288
+ cadence.""",
3289
+ "reference" :
3290
+ """PacketCable NCS Specification""",
3291
+ }, # column
3292
+ "pktcSigEndPntConfigMessageWaitingTO" : {
3293
+ "nodetype" : "column",
3294
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3295
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.7",
3296
+ "status" : "current",
3297
+ "syntax" : {
3298
+ "type" : { "module" :"", "name" : "Unsigned32"},
3299
+ },
3300
+ "access" : "readwrite",
3301
+ "default" : "16",
3302
+ "units" : "seconds",
3303
+ "description" :
3304
+ """ This object contains the default time out value for message
3305
+ waiting indicator. The MTA MUST NOT update this object
3306
+ with the value provided in the NCS message (if
3307
+ present). If the value of the object is modified by the
3308
+ SNMP Manager application, the MTA MUST use the new value
3309
+ as a default only for a new signal requested by the NCS
3310
+ message.
3311
+ The time out (TO) elements are intended to limit the time
3312
+ a tone or frequency is generated. When this MIB object is
3313
+ set to a value of '0', the MTA MUST NOT generate the
3314
+ corresponding frequency or tone, regardless of the
3315
+ definitions pertaining to frequency, tone duration, or
3316
+ cadence.""",
3317
+ "reference" :
3318
+ """PacketCable NCS Specification""",
3319
+ }, # column
3320
+ "pktcSigEndPntConfigOffHookWarnToneTO" : {
3321
+ "nodetype" : "column",
3322
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3323
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.8",
3324
+ "status" : "current",
3325
+ "syntax" : {
3326
+ "type" : { "module" :"", "name" : "Unsigned32"},
3327
+ },
3328
+ "access" : "readwrite",
3329
+ "default" : "0",
3330
+ "units" : "seconds",
3331
+ "description" :
3332
+ """ This object contains the default time out value for the
3333
+ off-hook warning tone. The MTA MUST NOT update this object
3334
+ with the value provided in the NCS message (if present). If
3335
+ the value of the object is modified by the SNMP Manager
3336
+
3337
+
3338
+
3339
+ application, the MTA MUST use the new value as a default
3340
+ only for a new signal requested by the NCS message. The
3341
+ time out (TO) elements are intended to limit the time a tone
3342
+ or frequency is generated. When this MIB object is set to a
3343
+ value of '0', the MTA MUST NOT generate the corresponding
3344
+ frequency or tone, regardless of the definitions pertaining
3345
+ to frequency, tone duration, or cadence.""",
3346
+ "reference" :
3347
+ """PacketCable NCS Specification""",
3348
+ }, # column
3349
+ "pktcSigEndPntConfigRingingTO" : {
3350
+ "nodetype" : "column",
3351
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3352
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.9",
3353
+ "status" : "current",
3354
+ "syntax" : {
3355
+ "type" : { "module" :"", "name" : "Unsigned32"},
3356
+ },
3357
+ "access" : "readwrite",
3358
+ "default" : "180",
3359
+ "units" : "seconds",
3360
+ "description" :
3361
+ """ This object contains the default time out value for
3362
+ ringing. The MTA MUST NOT update this object with the
3363
+ value provided in the NCS message (if present). If
3364
+ the value of the object is modified by the SNMP Management
3365
+ Station, the MTA MUST use the new value as a default only
3366
+ for a new signal requested by the NCS message.
3367
+ The time out (TO) elements are intended to limit the time
3368
+ a tone or frequency is generated. When this MIB object is
3369
+ set to a value of '0', the MTA MUST NOT generate the
3370
+ corresponding frequency or tone, regardless of the
3371
+ definitions pertaining to frequency, tone duration, or
3372
+ cadence.""",
3373
+ "reference" :
3374
+ """PacketCable NCS Specification""",
3375
+ }, # column
3376
+ "pktcSigEndPntConfigRingBackTO" : {
3377
+ "nodetype" : "column",
3378
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3379
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.10",
3380
+ "status" : "current",
3381
+ "syntax" : {
3382
+ "type" : { "module" :"", "name" : "Unsigned32"},
3383
+ },
3384
+ "access" : "readwrite",
3385
+ "default" : "180",
3386
+ "units" : "seconds",
3387
+ "description" :
3388
+ """ This object contains the default time out value for ring
3389
+ back. The MTA MUST NOT update this object with the
3390
+ value provided in the NCS message (if present). If
3391
+ the value of the object is modified by the SNMP Management
3392
+ Station, the MTA MUST use the new value as a default only
3393
+ for a new signal requested by the NCS message.
3394
+ The time out (TO) elements are intended to limit the time
3395
+
3396
+
3397
+
3398
+ a tone or frequency is generated. When this MIB object is
3399
+ set to a value of '0', the MTA MUST NOT generate the
3400
+ corresponding frequency or tone, regardless of the
3401
+ definitions pertaining to frequency, tone duration, or
3402
+ cadence.""",
3403
+ "reference" :
3404
+ """PacketCable NCS Specification""",
3405
+ }, # column
3406
+ "pktcSigEndPntConfigReorderToneTO" : {
3407
+ "nodetype" : "column",
3408
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3409
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.11",
3410
+ "status" : "current",
3411
+ "syntax" : {
3412
+ "type" : { "module" :"", "name" : "Unsigned32"},
3413
+ },
3414
+ "access" : "readwrite",
3415
+ "default" : "30",
3416
+ "units" : "seconds",
3417
+ "description" :
3418
+ """ This object contains the default time out value for reorder
3419
+ tone. The MTA MUST NOT update this object with the
3420
+ value provided in the NCS message (if present). If
3421
+ the value of the object is modified by the SNMP Management
3422
+ Station, the MTA MUST use the new value as a default only
3423
+ for a new signal requested by the NCS message.
3424
+ The time out (TO) elements are intended to limit the time
3425
+ a tone or frequency is generated. When this MIB object is
3426
+ set to a value of '0', the MTA MUST NOT generate the
3427
+ corresponding frequency or tone, regardless of the
3428
+ definitions pertaining to frequency, tone duration, or
3429
+ cadence.""",
3430
+ "reference" :
3431
+ """PacketCable NCS Specification""",
3432
+ }, # column
3433
+ "pktcSigEndPntConfigStutterDialToneTO" : {
3434
+ "nodetype" : "column",
3435
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3436
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.12",
3437
+ "status" : "current",
3438
+ "syntax" : {
3439
+ "type" : { "module" :"", "name" : "Unsigned32"},
3440
+ },
3441
+ "access" : "readwrite",
3442
+ "default" : "16",
3443
+ "units" : "seconds",
3444
+ "description" :
3445
+ """ This object contains the default time out value for stutter
3446
+ dial tone. The MTA MUST NOT update this object with the
3447
+ value provided in the NCS message (if present). If
3448
+ the value of the object is modified by the SNMP Management
3449
+ Station, the MTA MUST use the new value as a default only
3450
+ for a new signal requested by the NCS message.
3451
+ The time out (TO) elements are intended to limit the time
3452
+ a tone or frequency is generated. When this MIB object is
3453
+ set to a value of '0', the MTA MUST NOT generate the
3454
+
3455
+
3456
+
3457
+ corresponding frequency or tone, regardless of the
3458
+ definitions pertaining to frequency, tone duration, or
3459
+ cadence.""",
3460
+ "reference" :
3461
+ """PacketCable NCS Specification""",
3462
+ }, # column
3463
+ "pktcSigEndPntConfigTSMax" : {
3464
+ "nodetype" : "column",
3465
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3466
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.13",
3467
+ "status" : "current",
3468
+ "syntax" : {
3469
+ "type" : { "module" :"", "name" : "Unsigned32"},
3470
+ },
3471
+ "access" : "readwrite",
3472
+ "default" : "20",
3473
+ "description" :
3474
+ """This MIB object is used as part of an NCS
3475
+ retransmission algorithm. Prior to any retransmission,
3476
+ the MTA must check to make sure that the time elapsed
3477
+ since the sending of the initial datagram does not
3478
+ exceed the value specified by this MIB object. If more
3479
+ than Tsmax time has elapsed, then the retransmissions
3480
+ MUST cease.
3481
+
3482
+ Refer to the MIB object pktcSigEndPntConfigThist for
3483
+ information on when the endpoint becomes disconnected.""",
3484
+ "reference" :
3485
+ """PacketCable NCS Specification""",
3486
+ }, # column
3487
+ "pktcSigEndPntConfigMax1" : {
3488
+ "nodetype" : "column",
3489
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3490
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.14",
3491
+ "status" : "current",
3492
+ "syntax" : {
3493
+ "type" : { "module" :"", "name" : "Unsigned32"},
3494
+ },
3495
+ "access" : "readwrite",
3496
+ "default" : "5",
3497
+ "description" :
3498
+ """This object contains the suspicious error threshold for
3499
+ signaling messages. The pktcSigEndPntConfigMax1 object
3500
+ indicates the retransmission threshold at which the MTA MAY
3501
+ actively query the domain name server (DNS) in order to
3502
+ detect the possible change of call agent interfaces.""",
3503
+ "reference" :
3504
+ """PacketCable NCS Specification""",
3505
+ }, # column
3506
+ "pktcSigEndPntConfigMax2" : {
3507
+ "nodetype" : "column",
3508
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3509
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.15",
3510
+ "status" : "current",
3511
+ "syntax" : {
3512
+ "type" : { "module" :"", "name" : "Unsigned32"},
3513
+ },
3514
+ "access" : "readwrite",
3515
+ "default" : "7",
3516
+ "description" :
3517
+ """This object contains the disconnect error threshold for
3518
+ signaling messages. The pktcSigEndPntConfigMax2 object
3519
+ indicates the retransmission threshold at which the MTA
3520
+ SHOULD contact the DNS one more time to see if any other
3521
+ interfaces to the call agent have become available.""",
3522
+ "reference" :
3523
+ """PacketCable NCS Specification""",
3524
+ }, # column
3525
+ "pktcSigEndPntConfigMax1QEnable" : {
3526
+ "nodetype" : "column",
3527
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3528
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.16",
3529
+ "status" : "current",
3530
+ "syntax" : {
3531
+ "type" : { "module" :"SNMPv2-TC", "name" : "TruthValue"},
3532
+ },
3533
+ "access" : "readwrite",
3534
+ "default" : "true",
3535
+ "description" :
3536
+ """This object enables/disables the Max1 domain name server
3537
+ (DNS) query operation when the pktcSigEndPntConfigMax1
3538
+ threshold has been reached.
3539
+ A value of true(1) indicates enabling, and a value of
3540
+ false(2) indicates disabling.""",
3541
+ }, # column
3542
+ "pktcSigEndPntConfigMax2QEnable" : {
3543
+ "nodetype" : "column",
3544
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3545
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.17",
3546
+ "status" : "current",
3547
+ "syntax" : {
3548
+ "type" : { "module" :"SNMPv2-TC", "name" : "TruthValue"},
3549
+ },
3550
+ "access" : "readwrite",
3551
+ "default" : "true",
3552
+ "description" :
3553
+ """This object enables/disables the Max2 domain name server
3554
+ (DNS) query operation when the pktcSigEndPntConfigMax2
3555
+ threshold has been reached.
3556
+ A value of true(1) indicates enabling, and a value of
3557
+ false(2) indicates disabling.""",
3558
+ }, # column
3559
+ "pktcSigEndPntConfigMWD" : {
3560
+ "nodetype" : "column",
3561
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3562
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.18",
3563
+ "status" : "current",
3564
+ "syntax" : {
3565
+ "type" : { "module" :"", "name" : "Unsigned32"},
3566
+ },
3567
+ "access" : "readwrite",
3568
+ "default" : "600",
3569
+ "units" : "seconds",
3570
+ "description" :
3571
+ """Maximum Waiting Delay (MWD) contains the maximum number of
3572
+ seconds an MTA waits, after powering on, before initiating
3573
+ the restart procedure with the call agent.""",
3574
+ "reference" :
3575
+ """PacketCable NCS Specification""",
3576
+ }, # column
3577
+ "pktcSigEndPntConfigTdinit" : {
3578
+ "nodetype" : "column",
3579
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3580
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.19",
3581
+ "status" : "current",
3582
+ "syntax" : {
3583
+ "type" : { "module" :"", "name" : "Unsigned32"},
3584
+ },
3585
+ "access" : "readwrite",
3586
+ "default" : "15",
3587
+ "units" : "seconds",
3588
+ "description" :
3589
+ """This MIB object represents the 'disconnected' initial
3590
+ waiting delay within the context of an MTA's 'disconnected
3591
+ procedure'. The 'disconnected procedure' is initiated when
3592
+ an endpoint becomes 'disconnected' while attempting to
3593
+ communicate with a call agent.
3594
+
3595
+ The 'disconnected timer' associated with the 'disconnected
3596
+ Procedure' is initialized to a random value, uniformly
3597
+ distributed between zero and the value contained in this
3598
+ MIB object.
3599
+
3600
+ For more information on the usage of this timer, please
3601
+ refer to the PacketCable NCS Specification.""",
3602
+ "reference" :
3603
+ """PacketCable NCS Specification""",
3604
+ }, # column
3605
+ "pktcSigEndPntConfigTdmin" : {
3606
+ "nodetype" : "column",
3607
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3608
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.20",
3609
+ "status" : "current",
3610
+ "syntax" : {
3611
+ "type" : { "module" :"", "name" : "Unsigned32"},
3612
+ },
3613
+ "access" : "readwrite",
3614
+ "default" : "15",
3615
+ "units" : "seconds",
3616
+ "description" :
3617
+ """This MIB object represents the 'disconnected' minimum
3618
+ waiting delay within the context of an MTA's
3619
+ 'disconnected procedure', specifically when local user
3620
+ activity is detected.
3621
+ The 'disconnected procedure' is initiated when
3622
+ an endpoint becomes 'disconnected' while attempting to
3623
+ communicate with a call agent.
3624
+ For more information on the usage of this timer, please
3625
+ refer to the PacketCable NCS Specification.""",
3626
+ "reference" :
3627
+ """PacketCable NCS Specification""",
3628
+ }, # column
3629
+ "pktcSigEndPntConfigTdmax" : {
3630
+ "nodetype" : "column",
3631
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3632
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.21",
3633
+ "status" : "current",
3634
+ "syntax" : {
3635
+ "type" : { "module" :"", "name" : "Unsigned32"},
3636
+ },
3637
+ "access" : "readwrite",
3638
+ "default" : "600",
3639
+ "units" : "seconds",
3640
+ "description" :
3641
+ """ This object contains the maximum number of seconds the MTA
3642
+ waits, after a disconnect, before initiating the
3643
+ disconnected procedure with the call agent.
3644
+ """,
3645
+ "reference" :
3646
+ """PacketCable NCS Specification""",
3647
+ }, # column
3648
+ "pktcSigEndPntConfigRtoMax" : {
3649
+ "nodetype" : "column",
3650
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3651
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.22",
3652
+ "status" : "current",
3653
+ "syntax" : {
3654
+ "type" : { "module" :"", "name" : "Unsigned32"},
3655
+ },
3656
+ "access" : "readwrite",
3657
+ "default" : "4",
3658
+ "units" : "seconds",
3659
+ "description" :
3660
+ """This object specifies the maximum number of seconds the MTA
3661
+ waits for a response to an NCS message before initiating
3662
+ a retransmission.""",
3663
+ "reference" :
3664
+ """PacketCable NCS Specification""",
3665
+ }, # column
3666
+ "pktcSigEndPntConfigRtoInit" : {
3667
+ "nodetype" : "column",
3668
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3669
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.23",
3670
+ "status" : "current",
3671
+ "syntax" : {
3672
+ "type" : { "module" :"", "name" : "Unsigned32"},
3673
+ },
3674
+ "access" : "readwrite",
3675
+ "default" : "200",
3676
+ "units" : "milliseconds",
3677
+ "description" :
3678
+ """ This object contains the initial number of seconds for the
3679
+ retransmission timer.""",
3680
+ "reference" :
3681
+ """PacketCable NCS Specification""",
3682
+ }, # column
3683
+ "pktcSigEndPntConfigLongDurationKeepAlive" : {
3684
+ "nodetype" : "column",
3685
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3686
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.24",
3687
+ "status" : "current",
3688
+ "syntax" : {
3689
+ "type" : { "module" :"", "name" : "Unsigned32"},
3690
+ },
3691
+ "access" : "readwrite",
3692
+ "default" : "60",
3693
+ "units" : "minutes",
3694
+ "description" :
3695
+ """ Specifies a time out value, in minutes, for sending long
3696
+ duration call notification messages.""",
3697
+ "reference" :
3698
+ """PacketCable NCS Specification""",
3699
+ }, # column
3700
+ "pktcSigEndPntConfigThist" : {
3701
+ "nodetype" : "column",
3702
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3703
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.25",
3704
+ "status" : "current",
3705
+ "syntax" : {
3706
+ "type" : { "module" :"", "name" : "Unsigned32"},
3707
+ },
3708
+ "access" : "readwrite",
3709
+ "default" : "30",
3710
+ "units" : "seconds",
3711
+ "description" :
3712
+ """ Time out period, in seconds, before no response is declared.""",
3713
+ "reference" :
3714
+ """PacketCable NCS Specification""",
3715
+ }, # column
3716
+ "pktcSigEndPntConfigStatus" : {
3717
+ "nodetype" : "column",
3718
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3719
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.26",
3720
+ "status" : "current",
3721
+ "syntax" : {
3722
+ "type" : { "module" :"SNMPv2-TC", "name" : "RowStatus"},
3723
+ },
3724
+ "access" : "readwrite",
3725
+ "description" :
3726
+ """ This object contains the Row Status associated with the
3727
+ pktcSigEndPntConfigTable. There are no restrictions or
3728
+ dependencies amidst the columnar objects before this
3729
+ row can be activated or for modifications of the
3730
+ columnar objects when this object is set to a
3731
+ value of 'active(1).""",
3732
+ }, # column
3733
+ "pktcSigEndPntConfigCallWaitingMaxRep" : {
3734
+ "nodetype" : "column",
3735
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3736
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.27",
3737
+ "status" : "current",
3738
+ "syntax" : {
3739
+ "type" : {
3740
+ "basetype" : "Unsigned32",
3741
+ "ranges" : [
3742
+ {
3743
+ "min" : "0",
3744
+ "max" : "10"
3745
+ },
3746
+ ],
3747
+ "range" : {
3748
+ "min" : "0",
3749
+ "max" : "10"
3750
+ },
3751
+ },
3752
+ },
3753
+ "access" : "readwrite",
3754
+ "default" : "1",
3755
+ "description" :
3756
+ """ This object contains the default value of the maximum
3757
+ number of repetitions of the Call Waiting tone that the
3758
+ MTA will play from a single CMS request. The MTA MUST NOT
3759
+ update this object with the information provided in the
3760
+ NCS message (if present). If the value of the object is
3761
+ modified by the SNMP Manager application, the MTA MUST use
3762
+ the new value as a default only for a new signal
3763
+ requested by the NCS message.""",
3764
+ }, # column
3765
+ "pktcSigEndPntConfigCallWaitingDelay" : {
3766
+ "nodetype" : "column",
3767
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3768
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.28",
3769
+ "status" : "current",
3770
+ "syntax" : {
3771
+ "type" : {
3772
+ "basetype" : "Unsigned32",
3773
+ "ranges" : [
3774
+ {
3775
+ "min" : "1",
3776
+ "max" : "100"
3777
+ },
3778
+ ],
3779
+ "range" : {
3780
+ "min" : "1",
3781
+ "max" : "100"
3782
+ },
3783
+ },
3784
+ },
3785
+ "access" : "readwrite",
3786
+ "default" : "10",
3787
+ "units" : "seconds",
3788
+ "description" :
3789
+ """ This object contains the delay between repetitions of the
3790
+ Call Waiting tone that the MTA will play from a single CMS
3791
+ request.""",
3792
+ }, # column
3793
+ "pktcSigEndPntStatusCallIpAddressType" : {
3794
+ "nodetype" : "column",
3795
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3796
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.29",
3797
+ "status" : "current",
3798
+ "syntax" : {
3799
+ "type" : { "module" :"INET-ADDRESS-MIB", "name" : "InetAddressType"},
3800
+ },
3801
+ "access" : "readonly",
3802
+ "description" :
3803
+ """ This object contains the type of Internet address contained
3804
+ in the MIB object 'pktcSigEndPntStatusCallIpAddress'.
3805
+
3806
+ Since pktcSigEndPntStatusCallIpAddress is expected to
3807
+ contain an IP address, a value of dns(16) is disallowed.""",
3808
+ }, # column
3809
+ "pktcSigEndPntStatusCallIpAddress" : {
3810
+ "nodetype" : "column",
3811
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3812
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.30",
3813
+ "status" : "current",
3814
+ "syntax" : {
3815
+ "type" : { "module" :"INET-ADDRESS-MIB", "name" : "InetAddress"},
3816
+ },
3817
+ "access" : "readonly",
3818
+ "description" :
3819
+ """ This MIB object contains the chosen IP address of the CMS
3820
+ currently being used for the corresponding endpoint.
3821
+
3822
+ The device determines the IP address by using DNS to
3823
+ resolve the IP address of the CMS from the FQDN stored in
3824
+ the MIB object 'pktcSigEndPntConfigCallAgentId'. The
3825
+ processes are outlined in the PacketCable NCS and Security
3826
+ specifications, and MUST be followed by the MTA.
3827
+
3828
+ The IP address type contained in this MIB object is
3829
+ indicated by pktcSigEndPntStatusCallIpAddressType.""",
3830
+ "reference" :
3831
+ """PacketCable NCS Specification;
3832
+ PacketCable Security specification, [PKT-SP-SEC].""",
3833
+ }, # column
3834
+ "pktcSigEndPntStatusError" : {
3835
+ "nodetype" : "column",
3836
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3837
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.31",
3838
+ "status" : "current",
3839
+ "syntax" : {
3840
+ "type" : {
3841
+ "basetype" : "Enumeration",
3842
+ "operational" : {
3843
+ "nodetype" : "namednumber",
3844
+ "number" : "1"
3845
+ },
3846
+ "noSecurityAssociation" : {
3847
+ "nodetype" : "namednumber",
3848
+ "number" : "2"
3849
+ },
3850
+ "disconnected" : {
3851
+ "nodetype" : "namednumber",
3852
+ "number" : "3"
3853
+ },
3854
+ },
3855
+ },
3856
+ "access" : "readonly",
3857
+ "description" :
3858
+ """ This object contains the error status for this interface.
3859
+ The operational status indicates that all operations
3860
+ necessary to put the line in service have occurred, and the
3861
+ CMS has acknowledged the Restart In Progress (RSIP)
3862
+ message successfully. If pktcMtaDevCmsIpsecCtrl is enabled
3863
+ for the associated call agent, the noSecurityAssociation
3864
+ status indicates that no Security Association (SA) yet
3865
+ exists for this endpoint. If pktcMtaDevCmsIpsecCtrl is
3866
+ disabled for the associated call agent, the
3867
+ noSecurityAssociation status is not applicable and should
3868
+ not be used by the MTA. The disconnected status indicates
3869
+ one of the following two:
3870
+ If pktcMtaDevCmsIpsecCtrl is disabled, then no security
3871
+ association is involved with this endpoint. The NCS
3872
+ signaling software is in process of establishing the NCS
3873
+ signaling link via an RSIP exchange.
3874
+ Otherwise, when pktcMtaDevCmsIpsecCtrl is enabled,
3875
+ security Association has been established, and the NCS
3876
+ signaling software is in process of establishing the NCS
3877
+ signaling link via an RSIP exchange.""",
3878
+ }, # column
3879
+ "pktcSigEndPntConfigMinHookFlash" : {
3880
+ "nodetype" : "column",
3881
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3882
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.32",
3883
+ "status" : "current",
3884
+ "syntax" : {
3885
+ "type" : {
3886
+ "basetype" : "Unsigned32",
3887
+ "ranges" : [
3888
+ {
3889
+ "min" : "20",
3890
+ "max" : "1550"
3891
+ },
3892
+ ],
3893
+ "range" : {
3894
+ "min" : "20",
3895
+ "max" : "1550"
3896
+ },
3897
+ },
3898
+ },
3899
+ "access" : "readonly",
3900
+ "default" : "300",
3901
+ "units" : "Milliseconds",
3902
+ "description" :
3903
+ """ This is the minimum time a line needs to be on-hook for a
3904
+ valid hook flash. The value of this object MUST be
3905
+ greater than the value of
3906
+ pktcSigEndPntConfigPulseDialMaxBreakTime. The value of
3907
+ pktcSigEndPntConfigMinHookFlash MUST be less than
3908
+ pktcSigEndPntConfigMaxHookFlash. This object MUST only be
3909
+ set via the MTA configuration during the provisioning
3910
+ process.
3911
+ Furthermore, given the possibility for the 'pulse dial'
3912
+ and 'hook flash' to overlap, the value of this object
3913
+ MUST be greater than the value contained by the MIB
3914
+ Object 'pktcSigEndPntConfigPulseDialMaxMakeTime'.""",
3915
+ }, # column
3916
+ "pktcSigEndPntConfigMaxHookFlash" : {
3917
+ "nodetype" : "column",
3918
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3919
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.33",
3920
+ "status" : "current",
3921
+ "syntax" : {
3922
+ "type" : {
3923
+ "basetype" : "Unsigned32",
3924
+ "ranges" : [
3925
+ {
3926
+ "min" : "20",
3927
+ "max" : "1550"
3928
+ },
3929
+ ],
3930
+ "range" : {
3931
+ "min" : "20",
3932
+ "max" : "1550"
3933
+ },
3934
+ },
3935
+ },
3936
+ "access" : "readonly",
3937
+ "default" : "800",
3938
+ "units" : "Milliseconds",
3939
+ "description" :
3940
+ """ This is the maximum time a line needs to be on-hook for a
3941
+ valid hook flash. The value of
3942
+ pktcSigEndPntConfigMaxHookFlash MUST be greater than
3943
+ pktcSigEndPntConfigMinHookFlash. This object MUST only be
3944
+ set via the MTA configuration during the provisioning
3945
+ process.""",
3946
+ }, # column
3947
+ "pktcSigEndPntConfigPulseDialInterdigitTime" : {
3948
+ "nodetype" : "column",
3949
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3950
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.34",
3951
+ "status" : "current",
3952
+ "syntax" : {
3953
+ "type" : {
3954
+ "basetype" : "Unsigned32",
3955
+ "ranges" : [
3956
+ {
3957
+ "min" : "100",
3958
+ "max" : "1500"
3959
+ },
3960
+ ],
3961
+ "range" : {
3962
+ "min" : "100",
3963
+ "max" : "1500"
3964
+ },
3965
+ },
3966
+ },
3967
+ "access" : "readonly",
3968
+ "default" : "100",
3969
+ "units" : "Milliseconds",
3970
+ "description" :
3971
+ """ This is the pulse dial inter-digit time out. This object
3972
+ MUST only be set via the MTA configuration during the
3973
+ provisioning process.""",
3974
+ }, # column
3975
+ "pktcSigEndPntConfigPulseDialMinMakeTime" : {
3976
+ "nodetype" : "column",
3977
+ "moduleName" : "PKTC-IETF-SIG-MIB",
3978
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.35",
3979
+ "status" : "current",
3980
+ "syntax" : {
3981
+ "type" : {
3982
+ "basetype" : "Unsigned32",
3983
+ "ranges" : [
3984
+ {
3985
+ "min" : "20",
3986
+ "max" : "200"
3987
+ },
3988
+ ],
3989
+ "range" : {
3990
+ "min" : "20",
3991
+ "max" : "200"
3992
+ },
3993
+ },
3994
+ },
3995
+ "access" : "readonly",
3996
+ "default" : "25",
3997
+ "units" : "Milliseconds",
3998
+ "description" :
3999
+ """ This is the minimum make pulse width for the dial pulse.
4000
+ The value of pktcSigEndPntConfigPulseDialMinMakeTime MUST
4001
+ be less than pktcSigEndPntConfigPulseDialMaxMakeTime. This
4002
+ object MUST only be set via the MTA configuration during
4003
+ the provisioning process.""",
4004
+ }, # column
4005
+ "pktcSigEndPntConfigPulseDialMaxMakeTime" : {
4006
+ "nodetype" : "column",
4007
+ "moduleName" : "PKTC-IETF-SIG-MIB",
4008
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.36",
4009
+ "status" : "current",
4010
+ "syntax" : {
4011
+ "type" : {
4012
+ "basetype" : "Unsigned32",
4013
+ "ranges" : [
4014
+ {
4015
+ "min" : "20",
4016
+ "max" : "200"
4017
+ },
4018
+ ],
4019
+ "range" : {
4020
+ "min" : "20",
4021
+ "max" : "200"
4022
+ },
4023
+ },
4024
+ },
4025
+ "access" : "readonly",
4026
+ "default" : "55",
4027
+ "units" : "Milliseconds",
4028
+ "description" :
4029
+ """ This is the maximum make pulse width for the dial pulse.
4030
+
4031
+
4032
+
4033
+ The value of pktcSigEndPntConfigPulseDialMaxMakeTime MUST
4034
+ be greater than pktcSigEndPntConfigPulseDialMinMakeTime.
4035
+ This object MUST only be provided via the configuration
4036
+ file during the provisioning process.
4037
+ Furthermore, given the possibility for the 'pulse dial'
4038
+ and 'hook flash' to overlap, the value of this object MUST
4039
+ be less than the value contained by the MIB object
4040
+ pktcSigEndPntConfigMinHookFlash.""",
4041
+ }, # column
4042
+ "pktcSigEndPntConfigPulseDialMinBreakTime" : {
4043
+ "nodetype" : "column",
4044
+ "moduleName" : "PKTC-IETF-SIG-MIB",
4045
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.37",
4046
+ "status" : "current",
4047
+ "syntax" : {
4048
+ "type" : {
4049
+ "basetype" : "Unsigned32",
4050
+ "ranges" : [
4051
+ {
4052
+ "min" : "20",
4053
+ "max" : "200"
4054
+ },
4055
+ ],
4056
+ "range" : {
4057
+ "min" : "20",
4058
+ "max" : "200"
4059
+ },
4060
+ },
4061
+ },
4062
+ "access" : "readonly",
4063
+ "default" : "45",
4064
+ "units" : "Milliseconds",
4065
+ "description" :
4066
+ """ This is the minimum break pulse width for the dial pulse.
4067
+ The value of pktcSigEndPntConfigPulseDialMinBreakTime MUST
4068
+ be less than pktcSigEndPntConfigPulseDialMaxBreakTime.
4069
+ This object must only be provided via the configuration
4070
+ file during the provisioning process.""",
4071
+ }, # column
4072
+ "pktcSigEndPntConfigPulseDialMaxBreakTime" : {
4073
+ "nodetype" : "column",
4074
+ "moduleName" : "PKTC-IETF-SIG-MIB",
4075
+ "oid" : "1.3.6.1.2.1.169.1.2.1.1.38",
4076
+ "status" : "current",
4077
+ "syntax" : {
4078
+ "type" : {
4079
+ "basetype" : "Unsigned32",
4080
+ "ranges" : [
4081
+ {
4082
+ "min" : "20",
4083
+ "max" : "200"
4084
+ },
4085
+ ],
4086
+ "range" : {
4087
+ "min" : "20",
4088
+ "max" : "200"
4089
+ },
4090
+ },
4091
+ },
4092
+ "access" : "readonly",
4093
+ "default" : "75",
4094
+ "units" : "Milliseconds",
4095
+ "description" :
4096
+ """ This is the maximum break pulse width for the dial pulse.
4097
+ The value of pktcSigEndPntConfigPulseDialMaxBreakTime MUST
4098
+ be greater than pktcSigEndPntConfigPulseDialMinBreakTime.
4099
+ This object MUST only be provided via the configuration
4100
+ file during the provisioning process.""",
4101
+ }, # column
4102
+ "pktcSigConformance" : {
4103
+ "nodetype" : "node",
4104
+ "moduleName" : "PKTC-IETF-SIG-MIB",
4105
+ "oid" : "1.3.6.1.2.1.169.2",
4106
+ }, # node
4107
+ "pktcSigCompliances" : {
4108
+ "nodetype" : "node",
4109
+ "moduleName" : "PKTC-IETF-SIG-MIB",
4110
+ "oid" : "1.3.6.1.2.1.169.2.1",
4111
+ }, # node
4112
+ "pktcSigGroups" : {
4113
+ "nodetype" : "node",
4114
+ "moduleName" : "PKTC-IETF-SIG-MIB",
4115
+ "oid" : "1.3.6.1.2.1.169.2.2",
4116
+ }, # node
4117
+ }, # nodes
4118
+
4119
+ "groups" : {
4120
+ "pktcSigDeviceGroup" : {
4121
+ "nodetype" : "group",
4122
+ "moduleName" : "PKTC-IETF-SIG-MIB",
4123
+ "oid" : "1.3.6.1.2.1.169.2.2.1",
4124
+ "status" : "current",
4125
+ "members" : {
4126
+ "pktcSigDevCodecMax" : {
4127
+ "nodetype" : "member",
4128
+ "module" : "PKTC-IETF-SIG-MIB"
4129
+ },
4130
+ "pktcSigDevEchoCancellation" : {
4131
+ "nodetype" : "member",
4132
+ "module" : "PKTC-IETF-SIG-MIB"
4133
+ },
4134
+ "pktcSigDevSilenceSuppression" : {
4135
+ "nodetype" : "member",
4136
+ "module" : "PKTC-IETF-SIG-MIB"
4137
+ },
4138
+ "pktcSigDevR0Cadence" : {
4139
+ "nodetype" : "member",
4140
+ "module" : "PKTC-IETF-SIG-MIB"
4141
+ },
4142
+ "pktcSigDevR1Cadence" : {
4143
+ "nodetype" : "member",
4144
+ "module" : "PKTC-IETF-SIG-MIB"
4145
+ },
4146
+ "pktcSigDevR2Cadence" : {
4147
+ "nodetype" : "member",
4148
+ "module" : "PKTC-IETF-SIG-MIB"
4149
+ },
4150
+ "pktcSigDevR3Cadence" : {
4151
+ "nodetype" : "member",
4152
+ "module" : "PKTC-IETF-SIG-MIB"
4153
+ },
4154
+ "pktcSigDevR4Cadence" : {
4155
+ "nodetype" : "member",
4156
+ "module" : "PKTC-IETF-SIG-MIB"
4157
+ },
4158
+ "pktcSigDevR5Cadence" : {
4159
+ "nodetype" : "member",
4160
+ "module" : "PKTC-IETF-SIG-MIB"
4161
+ },
4162
+ "pktcSigDevR6Cadence" : {
4163
+ "nodetype" : "member",
4164
+ "module" : "PKTC-IETF-SIG-MIB"
4165
+ },
4166
+ "pktcSigDevR7Cadence" : {
4167
+ "nodetype" : "member",
4168
+ "module" : "PKTC-IETF-SIG-MIB"
4169
+ },
4170
+ "pktcSigDevRgCadence" : {
4171
+ "nodetype" : "member",
4172
+ "module" : "PKTC-IETF-SIG-MIB"
4173
+ },
4174
+ "pktcSigDevRsCadence" : {
4175
+ "nodetype" : "member",
4176
+ "module" : "PKTC-IETF-SIG-MIB"
4177
+ },
4178
+ "pktcSigDefCallSigDscp" : {
4179
+ "nodetype" : "member",
4180
+ "module" : "PKTC-IETF-SIG-MIB"
4181
+ },
4182
+ "pktcSigDefMediaStreamDscp" : {
4183
+ "nodetype" : "member",
4184
+ "module" : "PKTC-IETF-SIG-MIB"
4185
+ },
4186
+ "pktcSigDevVmwiMode" : {
4187
+ "nodetype" : "member",
4188
+ "module" : "PKTC-IETF-SIG-MIB"
4189
+ },
4190
+ "pktcSigCapabilityType" : {
4191
+ "nodetype" : "member",
4192
+ "module" : "PKTC-IETF-SIG-MIB"
4193
+ },
4194
+ "pktcSigCapabilityVersion" : {
4195
+ "nodetype" : "member",
4196
+ "module" : "PKTC-IETF-SIG-MIB"
4197
+ },
4198
+ "pktcSigCapabilityVendorExt" : {
4199
+ "nodetype" : "member",
4200
+ "module" : "PKTC-IETF-SIG-MIB"
4201
+ },
4202
+ "pktcSigDefNcsReceiveUdpPort" : {
4203
+ "nodetype" : "member",
4204
+ "module" : "PKTC-IETF-SIG-MIB"
4205
+ },
4206
+ }, # members
4207
+ "description" :
4208
+ """Group of MIB objects containing signaling configuration
4209
+ information that is applicable per-device.""",
4210
+ }, # group
4211
+ "pktcSigEndpointGroup" : {
4212
+ "nodetype" : "group",
4213
+ "moduleName" : "PKTC-IETF-SIG-MIB",
4214
+ "oid" : "1.3.6.1.2.1.169.2.2.2",
4215
+ "status" : "current",
4216
+ "members" : {
4217
+ "pktcSigEndPntConfigCallAgentId" : {
4218
+ "nodetype" : "member",
4219
+ "module" : "PKTC-IETF-SIG-MIB"
4220
+ },
4221
+ "pktcSigEndPntConfigCallAgentUdpPort" : {
4222
+ "nodetype" : "member",
4223
+ "module" : "PKTC-IETF-SIG-MIB"
4224
+ },
4225
+ "pktcSigEndPntConfigPartialDialTO" : {
4226
+ "nodetype" : "member",
4227
+ "module" : "PKTC-IETF-SIG-MIB"
4228
+ },
4229
+ "pktcSigEndPntConfigCriticalDialTO" : {
4230
+ "nodetype" : "member",
4231
+ "module" : "PKTC-IETF-SIG-MIB"
4232
+ },
4233
+ "pktcSigEndPntConfigBusyToneTO" : {
4234
+ "nodetype" : "member",
4235
+ "module" : "PKTC-IETF-SIG-MIB"
4236
+ },
4237
+ "pktcSigEndPntConfigDialToneTO" : {
4238
+ "nodetype" : "member",
4239
+ "module" : "PKTC-IETF-SIG-MIB"
4240
+ },
4241
+ "pktcSigEndPntConfigMessageWaitingTO" : {
4242
+ "nodetype" : "member",
4243
+ "module" : "PKTC-IETF-SIG-MIB"
4244
+ },
4245
+ "pktcSigEndPntConfigOffHookWarnToneTO" : {
4246
+ "nodetype" : "member",
4247
+ "module" : "PKTC-IETF-SIG-MIB"
4248
+ },
4249
+ "pktcSigEndPntConfigRingingTO" : {
4250
+ "nodetype" : "member",
4251
+ "module" : "PKTC-IETF-SIG-MIB"
4252
+ },
4253
+ "pktcSigEndPntConfigRingBackTO" : {
4254
+ "nodetype" : "member",
4255
+ "module" : "PKTC-IETF-SIG-MIB"
4256
+ },
4257
+ "pktcSigEndPntConfigReorderToneTO" : {
4258
+ "nodetype" : "member",
4259
+ "module" : "PKTC-IETF-SIG-MIB"
4260
+ },
4261
+ "pktcSigEndPntConfigStutterDialToneTO" : {
4262
+ "nodetype" : "member",
4263
+ "module" : "PKTC-IETF-SIG-MIB"
4264
+ },
4265
+ "pktcSigEndPntConfigTSMax" : {
4266
+ "nodetype" : "member",
4267
+ "module" : "PKTC-IETF-SIG-MIB"
4268
+ },
4269
+ "pktcSigEndPntConfigMax1" : {
4270
+ "nodetype" : "member",
4271
+ "module" : "PKTC-IETF-SIG-MIB"
4272
+ },
4273
+ "pktcSigEndPntConfigMax2" : {
4274
+ "nodetype" : "member",
4275
+ "module" : "PKTC-IETF-SIG-MIB"
4276
+ },
4277
+ "pktcSigEndPntConfigMax1QEnable" : {
4278
+ "nodetype" : "member",
4279
+ "module" : "PKTC-IETF-SIG-MIB"
4280
+ },
4281
+ "pktcSigEndPntConfigMax2QEnable" : {
4282
+ "nodetype" : "member",
4283
+ "module" : "PKTC-IETF-SIG-MIB"
4284
+ },
4285
+ "pktcSigEndPntConfigMWD" : {
4286
+ "nodetype" : "member",
4287
+ "module" : "PKTC-IETF-SIG-MIB"
4288
+ },
4289
+ "pktcSigEndPntConfigTdinit" : {
4290
+ "nodetype" : "member",
4291
+ "module" : "PKTC-IETF-SIG-MIB"
4292
+ },
4293
+ "pktcSigEndPntConfigTdmin" : {
4294
+ "nodetype" : "member",
4295
+ "module" : "PKTC-IETF-SIG-MIB"
4296
+ },
4297
+ "pktcSigEndPntConfigTdmax" : {
4298
+ "nodetype" : "member",
4299
+ "module" : "PKTC-IETF-SIG-MIB"
4300
+ },
4301
+ "pktcSigEndPntConfigRtoMax" : {
4302
+ "nodetype" : "member",
4303
+ "module" : "PKTC-IETF-SIG-MIB"
4304
+ },
4305
+ "pktcSigEndPntConfigRtoInit" : {
4306
+ "nodetype" : "member",
4307
+ "module" : "PKTC-IETF-SIG-MIB"
4308
+ },
4309
+ "pktcSigEndPntConfigLongDurationKeepAlive" : {
4310
+ "nodetype" : "member",
4311
+ "module" : "PKTC-IETF-SIG-MIB"
4312
+ },
4313
+ "pktcSigEndPntConfigThist" : {
4314
+ "nodetype" : "member",
4315
+ "module" : "PKTC-IETF-SIG-MIB"
4316
+ },
4317
+ "pktcSigEndPntConfigStatus" : {
4318
+ "nodetype" : "member",
4319
+ "module" : "PKTC-IETF-SIG-MIB"
4320
+ },
4321
+ "pktcSigEndPntConfigCallWaitingMaxRep" : {
4322
+ "nodetype" : "member",
4323
+ "module" : "PKTC-IETF-SIG-MIB"
4324
+ },
4325
+ "pktcSigEndPntConfigCallWaitingDelay" : {
4326
+ "nodetype" : "member",
4327
+ "module" : "PKTC-IETF-SIG-MIB"
4328
+ },
4329
+ "pktcSigEndPntStatusCallIpAddressType" : {
4330
+ "nodetype" : "member",
4331
+ "module" : "PKTC-IETF-SIG-MIB"
4332
+ },
4333
+ "pktcSigEndPntStatusCallIpAddress" : {
4334
+ "nodetype" : "member",
4335
+ "module" : "PKTC-IETF-SIG-MIB"
4336
+ },
4337
+ "pktcSigEndPntStatusError" : {
4338
+ "nodetype" : "member",
4339
+ "module" : "PKTC-IETF-SIG-MIB"
4340
+ },
4341
+ }, # members
4342
+ "description" :
4343
+ """Group of MIB objects containing signaling configuration
4344
+ information that is applicable per-endpoint.""",
4345
+ }, # group
4346
+ "pktcInternationalGroup" : {
4347
+ "nodetype" : "group",
4348
+ "moduleName" : "PKTC-IETF-SIG-MIB",
4349
+ "oid" : "1.3.6.1.2.1.169.2.2.3",
4350
+ "status" : "current",
4351
+ "members" : {
4352
+ "pktcSigEndPntConfigMinHookFlash" : {
4353
+ "nodetype" : "member",
4354
+ "module" : "PKTC-IETF-SIG-MIB"
4355
+ },
4356
+ "pktcSigEndPntConfigMaxHookFlash" : {
4357
+ "nodetype" : "member",
4358
+ "module" : "PKTC-IETF-SIG-MIB"
4359
+ },
4360
+ "pktcSigEndPntConfigPulseDialInterdigitTime" : {
4361
+ "nodetype" : "member",
4362
+ "module" : "PKTC-IETF-SIG-MIB"
4363
+ },
4364
+ "pktcSigEndPntConfigPulseDialMinMakeTime" : {
4365
+ "nodetype" : "member",
4366
+ "module" : "PKTC-IETF-SIG-MIB"
4367
+ },
4368
+ "pktcSigEndPntConfigPulseDialMaxMakeTime" : {
4369
+ "nodetype" : "member",
4370
+ "module" : "PKTC-IETF-SIG-MIB"
4371
+ },
4372
+ "pktcSigEndPntConfigPulseDialMinBreakTime" : {
4373
+ "nodetype" : "member",
4374
+ "module" : "PKTC-IETF-SIG-MIB"
4375
+ },
4376
+ "pktcSigEndPntConfigPulseDialMaxBreakTime" : {
4377
+ "nodetype" : "member",
4378
+ "module" : "PKTC-IETF-SIG-MIB"
4379
+ },
4380
+ "pktcSigDevRingCadence" : {
4381
+ "nodetype" : "member",
4382
+ "module" : "PKTC-IETF-SIG-MIB"
4383
+ },
4384
+ "pktcSigDevCidSigProtocol" : {
4385
+ "nodetype" : "member",
4386
+ "module" : "PKTC-IETF-SIG-MIB"
4387
+ },
4388
+ "pktcSigDevCidDelayAfterLR" : {
4389
+ "nodetype" : "member",
4390
+ "module" : "PKTC-IETF-SIG-MIB"
4391
+ },
4392
+ "pktcSigDevCidDtmfStartCode" : {
4393
+ "nodetype" : "member",
4394
+ "module" : "PKTC-IETF-SIG-MIB"
4395
+ },
4396
+ "pktcSigDevCidDtmfEndCode" : {
4397
+ "nodetype" : "member",
4398
+ "module" : "PKTC-IETF-SIG-MIB"
4399
+ },
4400
+ "pktcSigDevVmwiSigProtocol" : {
4401
+ "nodetype" : "member",
4402
+ "module" : "PKTC-IETF-SIG-MIB"
4403
+ },
4404
+ "pktcSigDevVmwiDelayAfterLR" : {
4405
+ "nodetype" : "member",
4406
+ "module" : "PKTC-IETF-SIG-MIB"
4407
+ },
4408
+ "pktcSigDevVmwiDtmfStartCode" : {
4409
+ "nodetype" : "member",
4410
+ "module" : "PKTC-IETF-SIG-MIB"
4411
+ },
4412
+ "pktcSigDevVmwiDtmfEndCode" : {
4413
+ "nodetype" : "member",
4414
+ "module" : "PKTC-IETF-SIG-MIB"
4415
+ },
4416
+ "pktcSigDevrpAsDtsDuration" : {
4417
+ "nodetype" : "member",
4418
+ "module" : "PKTC-IETF-SIG-MIB"
4419
+ },
4420
+ "pktcSigDevCidMode" : {
4421
+ "nodetype" : "member",
4422
+ "module" : "PKTC-IETF-SIG-MIB"
4423
+ },
4424
+ "pktcSigDevCidAfterRing" : {
4425
+ "nodetype" : "member",
4426
+ "module" : "PKTC-IETF-SIG-MIB"
4427
+ },
4428
+ "pktcSigDevCidAfterDTAS" : {
4429
+ "nodetype" : "member",
4430
+ "module" : "PKTC-IETF-SIG-MIB"
4431
+ },
4432
+ "pktcSigDevCidAfterRPAS" : {
4433
+ "nodetype" : "member",
4434
+ "module" : "PKTC-IETF-SIG-MIB"
4435
+ },
4436
+ "pktcSigDevRingAfterCID" : {
4437
+ "nodetype" : "member",
4438
+ "module" : "PKTC-IETF-SIG-MIB"
4439
+ },
4440
+ "pktcSigDevCidDTASAfterLR" : {
4441
+ "nodetype" : "member",
4442
+ "module" : "PKTC-IETF-SIG-MIB"
4443
+ },
4444
+ "pktcSigDevVmwiMode" : {
4445
+ "nodetype" : "member",
4446
+ "module" : "PKTC-IETF-SIG-MIB"
4447
+ },
4448
+ "pktcSigDevVmwiAfterDTAS" : {
4449
+ "nodetype" : "member",
4450
+ "module" : "PKTC-IETF-SIG-MIB"
4451
+ },
4452
+ "pktcSigDevVmwiAfterRPAS" : {
4453
+ "nodetype" : "member",
4454
+ "module" : "PKTC-IETF-SIG-MIB"
4455
+ },
4456
+ "pktcSigDevVmwiDTASAfterLR" : {
4457
+ "nodetype" : "member",
4458
+ "module" : "PKTC-IETF-SIG-MIB"
4459
+ },
4460
+ "pktcSigPowerRingFrequency" : {
4461
+ "nodetype" : "member",
4462
+ "module" : "PKTC-IETF-SIG-MIB"
4463
+ },
4464
+ "pktcSigPulseSignalFrequency" : {
4465
+ "nodetype" : "member",
4466
+ "module" : "PKTC-IETF-SIG-MIB"
4467
+ },
4468
+ "pktcSigPulseSignalDbLevel" : {
4469
+ "nodetype" : "member",
4470
+ "module" : "PKTC-IETF-SIG-MIB"
4471
+ },
4472
+ "pktcSigPulseSignalDuration" : {
4473
+ "nodetype" : "member",
4474
+ "module" : "PKTC-IETF-SIG-MIB"
4475
+ },
4476
+ "pktcSigPulseSignalPulseInterval" : {
4477
+ "nodetype" : "member",
4478
+ "module" : "PKTC-IETF-SIG-MIB"
4479
+ },
4480
+ "pktcSigPulseSignalRepeatCount" : {
4481
+ "nodetype" : "member",
4482
+ "module" : "PKTC-IETF-SIG-MIB"
4483
+ },
4484
+ "pktcSigDevToneDbLevel" : {
4485
+ "nodetype" : "member",
4486
+ "module" : "PKTC-IETF-SIG-MIB"
4487
+ },
4488
+ "pktcSigDevToneFreqCounter" : {
4489
+ "nodetype" : "member",
4490
+ "module" : "PKTC-IETF-SIG-MIB"
4491
+ },
4492
+ "pktcSigDevToneWholeToneRepeatCount" : {
4493
+ "nodetype" : "member",
4494
+ "module" : "PKTC-IETF-SIG-MIB"
4495
+ },
4496
+ "pktcSigDevToneSteady" : {
4497
+ "nodetype" : "member",
4498
+ "module" : "PKTC-IETF-SIG-MIB"
4499
+ },
4500
+ "pktcSigDevToneFirstFreqValue" : {
4501
+ "nodetype" : "member",
4502
+ "module" : "PKTC-IETF-SIG-MIB"
4503
+ },
4504
+ "pktcSigDevToneSecondFreqValue" : {
4505
+ "nodetype" : "member",
4506
+ "module" : "PKTC-IETF-SIG-MIB"
4507
+ },
4508
+ "pktcSigDevToneThirdFreqValue" : {
4509
+ "nodetype" : "member",
4510
+ "module" : "PKTC-IETF-SIG-MIB"
4511
+ },
4512
+ "pktcSigDevToneFourthFreqValue" : {
4513
+ "nodetype" : "member",
4514
+ "module" : "PKTC-IETF-SIG-MIB"
4515
+ },
4516
+ "pktcSigDevToneFreqMode" : {
4517
+ "nodetype" : "member",
4518
+ "module" : "PKTC-IETF-SIG-MIB"
4519
+ },
4520
+ "pktcSigDevToneFreqAmpModePrtg" : {
4521
+ "nodetype" : "member",
4522
+ "module" : "PKTC-IETF-SIG-MIB"
4523
+ },
4524
+ "pktcSigDevToneFreqOnDuration" : {
4525
+ "nodetype" : "member",
4526
+ "module" : "PKTC-IETF-SIG-MIB"
4527
+ },
4528
+ "pktcSigDevToneFreqOffDuration" : {
4529
+ "nodetype" : "member",
4530
+ "module" : "PKTC-IETF-SIG-MIB"
4531
+ },
4532
+ "pktcSigDevToneFreqRepeatCount" : {
4533
+ "nodetype" : "member",
4534
+ "module" : "PKTC-IETF-SIG-MIB"
4535
+ },
4536
+ }, # members
4537
+ "description" :
4538
+ """ Group of objects that extend the behavior of existing
4539
+ objects to support operations in the widest possible set
4540
+ of international marketplaces. Note that many of these
4541
+ objects represent a superset of behaviors described in
4542
+ other objects within this MIB module.""",
4543
+ }, # group
4544
+ "pktcLLinePackageGroup" : {
4545
+ "nodetype" : "group",
4546
+ "moduleName" : "PKTC-IETF-SIG-MIB",
4547
+ "oid" : "1.3.6.1.2.1.169.2.2.4",
4548
+ "status" : "current",
4549
+ "members" : {
4550
+ "pktcSigDevR0Cadence" : {
4551
+ "nodetype" : "member",
4552
+ "module" : "PKTC-IETF-SIG-MIB"
4553
+ },
4554
+ "pktcSigDevR1Cadence" : {
4555
+ "nodetype" : "member",
4556
+ "module" : "PKTC-IETF-SIG-MIB"
4557
+ },
4558
+ "pktcSigDevR2Cadence" : {
4559
+ "nodetype" : "member",
4560
+ "module" : "PKTC-IETF-SIG-MIB"
4561
+ },
4562
+ "pktcSigDevR3Cadence" : {
4563
+ "nodetype" : "member",
4564
+ "module" : "PKTC-IETF-SIG-MIB"
4565
+ },
4566
+ "pktcSigDevR4Cadence" : {
4567
+ "nodetype" : "member",
4568
+ "module" : "PKTC-IETF-SIG-MIB"
4569
+ },
4570
+ "pktcSigDevR5Cadence" : {
4571
+ "nodetype" : "member",
4572
+ "module" : "PKTC-IETF-SIG-MIB"
4573
+ },
4574
+ "pktcSigDevR6Cadence" : {
4575
+ "nodetype" : "member",
4576
+ "module" : "PKTC-IETF-SIG-MIB"
4577
+ },
4578
+ "pktcSigDevR7Cadence" : {
4579
+ "nodetype" : "member",
4580
+ "module" : "PKTC-IETF-SIG-MIB"
4581
+ },
4582
+ "pktcSigDevRgCadence" : {
4583
+ "nodetype" : "member",
4584
+ "module" : "PKTC-IETF-SIG-MIB"
4585
+ },
4586
+ "pktcSigDevRsCadence" : {
4587
+ "nodetype" : "member",
4588
+ "module" : "PKTC-IETF-SIG-MIB"
4589
+ },
4590
+ }, # members
4591
+ "description" :
4592
+ """Group of Objects to support the L line package.""",
4593
+ }, # group
4594
+ "pktcELinePackageGroup" : {
4595
+ "nodetype" : "group",
4596
+ "moduleName" : "PKTC-IETF-SIG-MIB",
4597
+ "oid" : "1.3.6.1.2.1.169.2.2.5",
4598
+ "status" : "current",
4599
+ "members" : {
4600
+ "pktcSigDevR0Cadence" : {
4601
+ "nodetype" : "member",
4602
+ "module" : "PKTC-IETF-SIG-MIB"
4603
+ },
4604
+ "pktcSigDevR1Cadence" : {
4605
+ "nodetype" : "member",
4606
+ "module" : "PKTC-IETF-SIG-MIB"
4607
+ },
4608
+ "pktcSigDevR2Cadence" : {
4609
+ "nodetype" : "member",
4610
+ "module" : "PKTC-IETF-SIG-MIB"
4611
+ },
4612
+ "pktcSigDevR3Cadence" : {
4613
+ "nodetype" : "member",
4614
+ "module" : "PKTC-IETF-SIG-MIB"
4615
+ },
4616
+ "pktcSigDevR4Cadence" : {
4617
+ "nodetype" : "member",
4618
+ "module" : "PKTC-IETF-SIG-MIB"
4619
+ },
4620
+ "pktcSigDevR5Cadence" : {
4621
+ "nodetype" : "member",
4622
+ "module" : "PKTC-IETF-SIG-MIB"
4623
+ },
4624
+ "pktcSigDevR6Cadence" : {
4625
+ "nodetype" : "member",
4626
+ "module" : "PKTC-IETF-SIG-MIB"
4627
+ },
4628
+ "pktcSigDevR7Cadence" : {
4629
+ "nodetype" : "member",
4630
+ "module" : "PKTC-IETF-SIG-MIB"
4631
+ },
4632
+ "pktcSigDevRgCadence" : {
4633
+ "nodetype" : "member",
4634
+ "module" : "PKTC-IETF-SIG-MIB"
4635
+ },
4636
+ "pktcSigDevRsCadence" : {
4637
+ "nodetype" : "member",
4638
+ "module" : "PKTC-IETF-SIG-MIB"
4639
+ },
4640
+ "pktcSigPulseSignalFrequency" : {
4641
+ "nodetype" : "member",
4642
+ "module" : "PKTC-IETF-SIG-MIB"
4643
+ },
4644
+ "pktcSigPulseSignalDbLevel" : {
4645
+ "nodetype" : "member",
4646
+ "module" : "PKTC-IETF-SIG-MIB"
4647
+ },
4648
+ "pktcSigPulseSignalDuration" : {
4649
+ "nodetype" : "member",
4650
+ "module" : "PKTC-IETF-SIG-MIB"
4651
+ },
4652
+ "pktcSigPulseSignalPulseInterval" : {
4653
+ "nodetype" : "member",
4654
+ "module" : "PKTC-IETF-SIG-MIB"
4655
+ },
4656
+ "pktcSigPulseSignalRepeatCount" : {
4657
+ "nodetype" : "member",
4658
+ "module" : "PKTC-IETF-SIG-MIB"
4659
+ },
4660
+ "pktcSigDevRingCadence" : {
4661
+ "nodetype" : "member",
4662
+ "module" : "PKTC-IETF-SIG-MIB"
4663
+ },
4664
+ }, # members
4665
+ "description" :
4666
+ """Group of Objects to support the E line package.""",
4667
+ }, # group
4668
+ }, # groups
4669
+
4670
+ "compliances" : {
4671
+ "pktcSigBasicCompliance" : {
4672
+ "nodetype" : "compliance",
4673
+ "moduleName" : "PKTC-IETF-SIG-MIB",
4674
+ "oid" : "1.3.6.1.2.1.169.2.1.1",
4675
+ "status" : "current",
4676
+ "description" :
4677
+ """ The compliance statement for MTAs that implement
4678
+ NCS signaling.""",
4679
+ "requires" : {
4680
+ "pktcSigDeviceGroup" : {
4681
+ "nodetype" : "mandatory",
4682
+ "module" : "PKTC-IETF-SIG-MIB"
4683
+ },
4684
+ "pktcSigEndpointGroup" : {
4685
+ "nodetype" : "mandatory",
4686
+ "module" : "PKTC-IETF-SIG-MIB"
4687
+ },
4688
+ "pktcInternationalGroup" : {
4689
+ "nodetype" : "optional",
4690
+ "module" : "PKTC-IETF-SIG-MIB",
4691
+ "description" :
4692
+ """ This group is mandatory only for MTAs implementing
4693
+ international telephony features.""",
4694
+ },
4695
+ "pktcLLinePackageGroup" : {
4696
+ "nodetype" : "optional",
4697
+ "module" : "PKTC-IETF-SIG-MIB",
4698
+ "description" :
4699
+ """ This group is mandatory only for MTAs implementing the L
4700
+ line package.""",
4701
+ },
4702
+ "pktcELinePackageGroup" : {
4703
+ "nodetype" : "optional",
4704
+ "module" : "PKTC-IETF-SIG-MIB",
4705
+ "description" :
4706
+ """ This group is mandatory only for MTAs implementing the E
4707
+ Line Package.""",
4708
+ },
4709
+ }, # requires
4710
+ }, # compliance
4711
+ }, # compliances
4712
+
4713
+ }