epb_view_models 2.0.2 → 2.0.3

Sign up to get free protection for your applications and to get access to all the features.
checksums.yaml CHANGED
@@ -1,7 +1,7 @@
1
1
  ---
2
2
  SHA256:
3
- metadata.gz: eba0fe6457b3cf5f495a525078f3133925a4912aeb79d4bcc6cc51198ec6dde4
4
- data.tar.gz: 2cd6472f1cee4ccfcb204011e3934fea2869a1ee05ac92fc90134107a974cc2f
3
+ metadata.gz: 768d1bc10b159343564b8a6a1d9b7392798195b2d98f9657744466cc378bcce7
4
+ data.tar.gz: d63ea784d42ac5f2e9740a36001f6695010c08c776c75d39701b9f3ca61022e8
5
5
  SHA512:
6
- metadata.gz: eb77bd68775de7d39a2b6392b7db48a3b6270368538666ba01e28621f23575a12f2021815a10569fa52c24b250644ce90a4d20f28e97dd76dace2a163de2235b
7
- data.tar.gz: b307a6b3678c5de25174be0dce9bd0ff86f617127a1954ace9c218b0773e4bd742d14379fb07a228483fcb1e482f384d23c4f821d8705849f20a435951c568f6
6
+ metadata.gz: 5a988e042c962e0d0f12da4be1b2cc52a60a79fb581cddaa43ff897af2ab8ed9b182d56b97397785490924a5c033f4cddfc4ec17bcda35d42bbf7092cbe003e1
7
+ data.tar.gz: 407b7f502348d6b181d44027ce7db28420da8e1c6ea1cbd1508ed60c9fc5f364c3f71f530d82918ea24e62a25f4f1020ce3ec6e6a45e09157484af31c2bc24be
@@ -1,8 +1,8 @@
1
1
  <?xml version="1.0" encoding="UTF-8"?>
2
2
  <!--EPC Recommendations, RdSAP Addenda, Transaction Types, Tenures and Related Party Disclosure-->
3
3
  <EPC:ExternalDefinitions xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="EPC ExternalDefinitions.xsd" xmlns:EPC="EPC">
4
- <Revision-Number>6.1</Revision-Number>
5
- <Revision-Date>2019-06-11</Revision-Date>
4
+ <Revision-Number>8.0</Revision-Number>
5
+ <Revision-Date>2024-03-13</Revision-Date>
6
6
  <Country>
7
7
  <Country-Code>EAW</Country-Code>
8
8
  <Average-SAP-Rating>60</Average-SAP-Rating>
@@ -240,6 +240,24 @@
240
240
  <Improvement-Description language="1">Gas condensing boiler</Improvement-Description>
241
241
  <Improvement-Description language="2">Bwyler cyddwyso nwy</Improvement-Description>
242
242
  </Recommendation>
243
+ <Recommendation>
244
+ <Improvement-Number>72</Improvement-Number>
245
+ <Improvement-Summary language="1">Add PV battery</Improvement-Summary>
246
+ <Improvement-Summary language="2">Newid system wresogi i fwyler cyddwyso nwy</Improvement-Summary>
247
+ <Improvement-Heading language="1">Gas condensing boiler</Improvement-Heading>
248
+ <Improvement-Heading language="2">Bwyler cyddwyso nwy</Improvement-Heading>
249
+ <Improvement-Description language="1">Gas condensing boiler</Improvement-Description>
250
+ <Improvement-Description language="2">Bwyler cyddwyso nwy</Improvement-Description>
251
+ </Recommendation>
252
+ <Recommendation>
253
+ <Improvement-Number>73</Improvement-Number>
254
+ <Improvement-Summary language="1">Add PV diverter</Improvement-Summary>
255
+ <Improvement-Summary language="2">Newid system wresogi i fwyler cyddwyso nwy</Improvement-Summary>
256
+ <Improvement-Heading language="1">Gas condensing boiler</Improvement-Heading>
257
+ <Improvement-Heading language="2">Bwyler cyddwyso nwy</Improvement-Heading>
258
+ <Improvement-Description language="1">Gas condensing boiler</Improvement-Description>
259
+ <Improvement-Description language="2">Bwyler cyddwyso nwy</Improvement-Description>
260
+ </Recommendation>
243
261
  <Recommendation>
244
262
  <Improvement-Number>34</Improvement-Number>
245
263
  <Improvement-Summary language="1">Solar photovoltaic panels, 2.5 kWp</Improvement-Summary>
@@ -474,7 +492,7 @@
474
492
  <Improvement-Description language="1">High heat retention storage heaters</Improvement-Description>
475
493
  <Improvement-Description language="2">Gwresogyddion storio sy’n cadw llawer o wres</Improvement-Description>
476
494
  </Recommendation>
477
- <Recommendation>
495
+ <Recommendation>
478
496
  <Improvement-Number>63</Improvement-Number>
479
497
  <Improvement-Summary language="1">Party wall insulation</Improvement-Summary>
480
498
  <Improvement-Summary language="2">Insiwleiddio muriau cyd</Improvement-Summary>
@@ -517,36 +535,24 @@
517
535
  </Transaction-Type>
518
536
  <Transaction-Type>
519
537
  <Display-Order>6</Display-Order>
520
- <Transaction-Code>9</Transaction-Code>
521
- <Transaction-Text>Assessment for Green Deal</Transaction-Text>
538
+ <Transaction-Code>16</Transaction-Code>
539
+ <Transaction-Text>Grant scheme</Transaction-Text>
522
540
  <In-RdSAP>true</In-RdSAP>
523
541
  </Transaction-Type>
524
542
  <Transaction-Type>
525
543
  <Display-Order>7</Display-Order>
526
- <Transaction-Code>10</Transaction-Code>
527
- <Transaction-Text>Following Green Deal</Transaction-Text>
544
+ <Transaction-Code>17</Transaction-Code>
545
+ <Transaction-Text>Non-grant scheme</Transaction-Text>
528
546
  <In-RdSAP>true</In-RdSAP>
529
547
  </Transaction-Type>
530
548
  <Transaction-Type>
531
549
  <Display-Order>8</Display-Order>
532
- <Transaction-Code>11</Transaction-Code>
533
- <Transaction-Text>FiT application</Transaction-Text>
550
+ <Transaction-Code>15</Transaction-Code>
551
+ <Transaction-Text>Re-mortgaging</Transaction-Text>
534
552
  <In-RdSAP>true</In-RdSAP>
535
553
  </Transaction-Type>
536
554
  <Transaction-Type>
537
555
  <Display-Order>9</Display-Order>
538
- <Transaction-Code>12</Transaction-Code>
539
- <Transaction-Text>RHI application</Transaction-Text>
540
- <In-RdSAP>true</In-RdSAP>
541
- </Transaction-Type>
542
- <Transaction-Type>
543
- <Display-Order>10</Display-Order>
544
- <Transaction-Code>13</Transaction-Code>
545
- <Transaction-Text>ECO assessment</Transaction-Text>
546
- <In-RdSAP>true</In-RdSAP>
547
- </Transaction-Type>
548
- <Transaction-Type>
549
- <Display-Order>11</Display-Order>
550
556
  <Transaction-Code>5</Transaction-Code>
551
557
  <Transaction-Text>None of the above</Transaction-Text>
552
558
  <In-RdSAP>true</In-RdSAP>
@@ -674,7 +680,7 @@
674
680
  <Improvement-Summary-2 language="1">Internal or external wall insulation</Improvement-Summary-2>
675
681
  <Improvement-Heading language="1">Internal or external wall insulation</Improvement-Heading>
676
682
  <Improvement-Description language="1">Internal or external wall insulation involves adding a layer of insulation to either the inside or the outside surface of the external walls, which reduces heat loss and lowers fuel bills. As it is more expensive than cavity wall insulation it is only recommended for walls without a cavity, or where for technical reasons a cavity cannot be filled. Internal insulation, known as dry-lining, is where a layer of insulation is fixed to the inside surface of external walls; this type of insulation is best applied when rooms require redecorating. External solid wall insulation is the application of an insulant and a weather-protective finish to the outside of the wall. This may improve the look of the home, particularly where existing brickwork or rendering is poor, and will provide long-lasting weather protection. Further information can be obtained from the National Insulation Association (www.nationalinsulationassociation.org.uk). It should be noted that a building warrant is required for the installation of external wall insulation. Planning permission may also be required and that building regulations apply to external insulation so it is best to check with your local authority on both issues.
677
- </Improvement-Description>
683
+ </Improvement-Description>
678
684
  </Recommendation>
679
685
  <Recommendation>
680
686
  <Improvement-Number>8</Improvement-Number>
@@ -992,7 +998,7 @@
992
998
  <Improvement-Heading language="1">High heat retention storage heaters</Improvement-Heading>
993
999
  <Improvement-Description language="1">Modern storage heaters are less expensive to run than the direct acting, on-peak heating system in the property. A dual-rate electricity supply is required to provide the off-peak electricity that these heaters use; this is easily obtained by contacting the energy supplier. Ask for a quotation for high heat retention with automatic charge and output controls. Installations should be in accordance with the national wiring standards. Building regulations generally apply to this work and a building warrant may be required, so it is best to obtain advice from your local authority building standards department and from a qualified electrical heating engineer. Ask the heating engineer to explain the options, which might also include switching to other forms of electric heating.</Improvement-Description>
994
1000
  </Recommendation>
995
- <Recommendation>
1001
+ <Recommendation>
996
1002
  <Improvement-Number>63</Improvement-Number>
997
1003
  <Improvement-Summary language="1">Party wall insulation</Improvement-Summary>
998
1004
  <Improvement-Summary-2 language="1">Party wall insulation</Improvement-Summary-2>
@@ -1440,7 +1446,7 @@
1440
1446
  <Improvement-Heading language="1">High heat retention storage heaters</Improvement-Heading>
1441
1447
  <Improvement-Description language="1">Modern storage heaters are less expensive to run than the direct acting, on-peak heating system in the property. A dual-rate electricity supply is required to provide the off-peak electricity that these heaters use; this is easily obtained by contacting the energy supplier. Ask for a quotation for high heat retention heaters with automatic charge and output controls. As installations should be in accordance with the national wiring standards, only a qualified electrician should carry out the installation. It is best to obtain advice from a qualified electrical heating engineer. Ask a qualified electrical heating engineer to explain the options, which might also include switching to other forms of electric heating.</Improvement-Description>
1442
1448
  </Recommendation>
1443
- <Recommendation>
1449
+ <Recommendation>
1444
1450
  <Improvement-Number>63</Improvement-Number>
1445
1451
  <Improvement-Summary language="1">Party wall insulation</Improvement-Summary>
1446
1452
  <Improvement-Heading language="1">Party wall insulation</Improvement-Heading>
@@ -1567,9 +1573,39 @@
1567
1573
  <Addendum-Text language="1">The dwelling uses a type of fuel that is not included in the available options. The nearest equivalent fuel type was used for the assessment.</Addendum-Text>
1568
1574
  <Addendum-Text language="2">Nid yw’r math o danwydd y mae’r anheddiad yn ei ddefnyddio wedi ei restru yn yr opsiynau sydd ar gael. Defnyddiwyd y math cyfatebol tebycaf o danwydd ar gyfer yr asesiad.</Addendum-Text>
1569
1575
  </Addendum>
1576
+ <Addendum>
1577
+ <Addendum-Number>13</Addendum-Number>
1578
+ <Circumstances>13. Dwelling has a special energy saving feature </Circumstances>
1579
+ <Addendum-Text language="1">The dwelling has a special energy saving feature which is recognised in the assessment, but its impact on the savings shown for improvement measures is ignored.</Addendum-Text>
1580
+ <Addendum-Text language="2">[Welsh translation of the above]</Addendum-Text>
1581
+ </Addendum>
1570
1582
  <Addendum>
1571
1583
  <Addendum-Number>14</Addendum-Number>
1572
- <Circumstances>14. Dwelling has a special energy saving feature </Circumstances>
1584
+ <Circumstances>14. Conservation area </Circumstances>
1585
+ <Addendum-Text language="1">Conservation area.</Addendum-Text>
1586
+ <Addendum-Text language="2">[Welsh translation of the above]</Addendum-Text>
1587
+ </Addendum>
1588
+ <Addendum>
1589
+ <Addendum-Number>15</Addendum-Number>
1590
+ <Circumstances>15. PV recommended </Circumstances>
1591
+ <Addendum-Text language="1">When considering the PV installation consider installing PV battery and PV diverter for water heating.</Addendum-Text>
1592
+ <Addendum-Text language="2">[Welsh translation of the above]</Addendum-Text>
1593
+ </Addendum>
1594
+ <Addendum>
1595
+ <Addendum-Number>16</Addendum-Number>
1596
+ <Circumstances>16. PV-independent battery storage present </Circumstances>
1597
+ <Addendum-Text language="1">The dwelling has a special energy saving feature which is recognised in the assessment, but its impact on the savings shown for improvement measures is ignored.</Addendum-Text>
1598
+ <Addendum-Text language="2">[Welsh translation of the above]</Addendum-Text>
1599
+ </Addendum>
1600
+ <Addendum>
1601
+ <Addendum-Number>17</Addendum-Number>
1602
+ <Circumstances>17. 'Phase changing' heat storage present </Circumstances>
1603
+ <Addendum-Text language="1">The dwelling has a special energy saving feature which is recognised in the assessment, but its impact on the savings shown for improvement measures is ignored.</Addendum-Text>
1604
+ <Addendum-Text language="2">[Welsh translation of the above]</Addendum-Text>
1605
+ </Addendum>
1606
+ <Addendum>
1607
+ <Addendum-Number>18</Addendum-Number>
1608
+ <Circumstances>18. Party wall insulation </Circumstances>
1573
1609
  <Addendum-Text language="1">The dwelling has a special energy saving feature which is recognised in the assessment, but its impact on the savings shown for improvement measures is ignored.</Addendum-Text>
1574
1610
  <Addendum-Text language="2">[Welsh translation of the above]</Addendum-Text>
1575
1611
  </Addendum>
@@ -226,7 +226,6 @@ The Improved Energy Ratings that result from carrying out a Suggested Improvemen
226
226
  </xs:complexType>
227
227
  </xs:element>
228
228
  <xs:element name="Indicative-Cost" type="xs:string" minOccurs="0"/>
229
- <xs:element name="Green-Deal-Category" type="GreenDealCategoryCode"/>
230
229
  </xs:all>
231
230
  </xs:complexType>
232
231
  <xs:element name="PropertySummaryType" type="PropertySummaryType"/>
@@ -187,6 +187,36 @@ This is actually the type differentiator for Property but only a limited number
187
187
  <xs:documentation>If MVHR from pcdb.</xs:documentation>
188
188
  </xs:annotation>
189
189
  </xs:element>
190
+ <xs:element name="Kitchen-Room-Fans-Count" type="Count" minOccurs="0">
191
+ <xs:annotation>
192
+ <xs:documentation>MEV dc, number of fans in room, kitchen; if mechanical vent data from database or manufacturer declaration (MEV dc).</xs:documentation>
193
+ </xs:annotation>
194
+ </xs:element>
195
+ <xs:element name="Non-Kitchen-Room-Fans-Count" type="Count" minOccurs="0">
196
+ <xs:annotation>
197
+ <xs:documentation>MEV dc, number of fans in room, rooms other than kitchen; if mechanical vent data from database or manufacturer declaration (MEV dc).</xs:documentation>
198
+ </xs:annotation>
199
+ </xs:element>
200
+ <xs:element name="Kitchen-Duct-Fans-Count" type="Count" minOccurs="0">
201
+ <xs:annotation>
202
+ <xs:documentation>MEV dc, number of fans via duct, kitchen; if mechanical vent data from database or manufacturer declaration (MEV dc).</xs:documentation>
203
+ </xs:annotation>
204
+ </xs:element>
205
+ <xs:element name="Non-Kitchen-Duct-Fans-Count" type="Count" minOccurs="0">
206
+ <xs:annotation>
207
+ <xs:documentation>MEV dc, number of fans via duct, rooms other than kitchen; if mechanical vent data from database or manufacturer declaration (MEV dc).</xs:documentation>
208
+ </xs:annotation>
209
+ </xs:element>
210
+ <xs:element name="Kitchen-Wall-Fans-Count" type="Count" minOccurs="0">
211
+ <xs:annotation>
212
+ <xs:documentation>MEV dc, number of fans through wall, kitchen; if mechanical vent data from database or manufacturer declaration (MEV dc).</xs:documentation>
213
+ </xs:annotation>
214
+ </xs:element>
215
+ <xs:element name="Non-Kitchen-Wall-Fans-Count" type="Count" minOccurs="0">
216
+ <xs:annotation>
217
+ <xs:documentation>MEV dc, number of fans through wall, rooms other than kitchen; if mechanical vent data from database or manufacturer declaration (MEV dc).</xs:documentation>
218
+ </xs:annotation>
219
+ </xs:element>
190
220
  <xs:element name="Conservatory-Type" type="SAP-ConservatoryTypeCode">
191
221
  <xs:annotation>
192
222
  <xs:documentation>Type of Conservatory</xs:documentation>
@@ -225,6 +255,11 @@ This is actually the type differentiator for Property but only a limited number
225
255
  <xs:documentation>Number of insulated external doors</xs:documentation>
226
256
  </xs:annotation>
227
257
  </xs:element>
258
+ <xs:element name="Draughtproofed-Door-Count" type="Count" minOccurs="0">
259
+ <xs:annotation>
260
+ <xs:documentation>Number of draught proofed external doors</xs:documentation>
261
+ </xs:annotation>
262
+ </xs:element>
228
263
  <xs:element name="Insulated-Door-U-Value" type="xs:decimal" minOccurs="0"/>
229
264
  <xs:element name="Percent-Draughtproofed">
230
265
  <xs:annotation>
@@ -743,17 +778,6 @@ For the purpose of calculating the overall Energy Assessment for the property de
743
778
  <xs:all>
744
779
  <xs:element name="Floor-Area" type="Measurement"/>
745
780
  <xs:element name="Construction-Age-Band" type="ConstructionDateCode"/>
746
- <xs:element name="Insulation" type="SAP-RoomInRoofInsulationCode" minOccurs="0"/>
747
- <xs:element name="Roof-Room-Connected" type="Flag">
748
- <xs:annotation>
749
- <xs:documentation>Whether the roof room is connected to another building part of the same dwelling</xs:documentation>
750
- </xs:annotation>
751
- </xs:element>
752
- <xs:element name="Roof-Insulation-Thickness" type="RoofInsulationThicknessCode" minOccurs="0">
753
- <xs:annotation>
754
- <xs:documentation>Use ND when Room-In-Roof-Details is included</xs:documentation>
755
- </xs:annotation>
756
- </xs:element>
757
781
  <xs:element name="Room-In-Roof-Details" type="Room-In-Roof-Details" minOccurs="0">
758
782
  <xs:annotation>
759
783
  <xs:documentation>Omit when Room-In-Roof details not included</xs:documentation>
@@ -1000,6 +1024,11 @@ If the total peak power has been apportioned between different dwellings within
1000
1024
  <xs:documentation>Mutually exclusive with U-value. Either U-value provided, or thickness.</xs:documentation>
1001
1025
  </xs:annotation>
1002
1026
  </xs:element>
1027
+ <xs:element name="Flat-Ceiling-Insulation-Location-1" type="RoofInsulationLocationCode" minOccurs="0">
1028
+ <xs:annotation>
1029
+ <xs:documentation>Mutually exclusive with U-value and insulation type. Either U-value provided, or insulation type or location. To enable using table 16.</xs:documentation>
1030
+ </xs:annotation>
1031
+ </xs:element>
1003
1032
  <xs:element name="Flat-Ceiling-Length-2" type="Measurement" minOccurs="0"/>
1004
1033
  <xs:element name="Flat-Ceiling-Height-2" type="Measurement" minOccurs="0"/>
1005
1034
  <xs:element name="Flat-Ceiling-U-Value-2" type="xs:decimal" minOccurs="0"/>
@@ -1013,6 +1042,11 @@ If the total peak power has been apportioned between different dwellings within
1013
1042
  <xs:documentation>Mutually exclusive with U-value. Either U-value provided, or thickness.</xs:documentation>
1014
1043
  </xs:annotation>
1015
1044
  </xs:element>
1045
+ <xs:element name="Flat-Ceiling-Insulation-Location-2" type="RoofInsulationLocationCode" minOccurs="0">
1046
+ <xs:annotation>
1047
+ <xs:documentation>Mutually exclusive with U-value and insulation type. Either U-value provided, or insulation type or location. To enable using table 16.</xs:documentation>
1048
+ </xs:annotation>
1049
+ </xs:element>
1016
1050
  <xs:element name="Stud-Wall-Length-1" type="Measurement" minOccurs="0"/>
1017
1051
  <xs:element name="Stud-Wall-Height-1" type="Measurement" minOccurs="0"/>
1018
1052
  <xs:element name="Stud-Wall-U-Value-1" type="xs:decimal" minOccurs="0"/>
@@ -1068,9 +1102,19 @@ If the total peak power has been apportioned between different dwellings within
1068
1102
  <xs:element name="Gable-Wall-Length-1" type="Measurement" minOccurs="0"/>
1069
1103
  <xs:element name="Gable-Wall-Height-1" type="Measurement" minOccurs="0"/>
1070
1104
  <xs:element name="Gable-Wall-U-Value-1" type="xs:decimal" minOccurs="0"/>
1105
+ <xs:element name="Gable-Wall-Type-1" type="GableType" minOccurs="0">
1106
+ <xs:annotation>
1107
+ <xs:documentation>Mutually exclusive with U-value. Either U-value provided, or gable type to use table 4.</xs:documentation>
1108
+ </xs:annotation>
1109
+ </xs:element>
1071
1110
  <xs:element name="Gable-Wall-Length-2" type="Measurement" minOccurs="0"/>
1072
1111
  <xs:element name="Gable-Wall-Height-2" type="Measurement" minOccurs="0"/>
1073
1112
  <xs:element name="Gable-Wall-U-Value-2" type="xs:decimal" minOccurs="0"/>
1113
+ <xs:element name="Gable-Wall-Type-2" type="GableType" minOccurs="0">
1114
+ <xs:annotation>
1115
+ <xs:documentation>Mutually exclusive with U-value. Either U-value provided, or gable type to use table 4.</xs:documentation>
1116
+ </xs:annotation>
1117
+ </xs:element>
1074
1118
  <xs:element name="Common-Wall-Length-1" type="Measurement" minOccurs="0"/>
1075
1119
  <xs:element name="Common-Wall-Height-1" type="Measurement" minOccurs="0"/>
1076
1120
  <xs:element name="Common-Wall-U-Value-1" type="xs:decimal" minOccurs="0"/>
@@ -461,6 +461,41 @@
461
461
  <xs:documentation>Party wall insulation</xs:documentation>
462
462
  </xs:annotation>
463
463
  </xs:enumeration>
464
+ <xs:enumeration value="65">
465
+ <xs:annotation>
466
+ <xs:documentation>Internal insulation with cavity wall insulation</xs:documentation>
467
+ </xs:annotation>
468
+ </xs:enumeration>
469
+ <xs:enumeration value="66">
470
+ <xs:annotation>
471
+ <xs:documentation>Heating controls for wet central heating system</xs:documentation>
472
+ </xs:annotation>
473
+ </xs:enumeration>
474
+ <xs:enumeration value="70">
475
+ <xs:annotation>
476
+ <xs:documentation>Water Heating Controls</xs:documentation>
477
+ </xs:annotation>
478
+ </xs:enumeration>
479
+ <xs:enumeration value="72">
480
+ <xs:annotation>
481
+ <xs:documentation>PV Battery</xs:documentation>
482
+ </xs:annotation>
483
+ </xs:enumeration>
484
+ <xs:enumeration value="73">
485
+ <xs:annotation>
486
+ <xs:documentation>PV Diverter</xs:documentation>
487
+ </xs:annotation>
488
+ </xs:enumeration>
489
+ <xs:enumeration value="75">
490
+ <xs:annotation>
491
+ <xs:documentation>Ground source heat pump with radiators</xs:documentation>
492
+ </xs:annotation>
493
+ </xs:enumeration>
494
+ <xs:enumeration value="76">
495
+ <xs:annotation>
496
+ <xs:documentation>Ground source heat pump with underfloor heating</xs:documentation>
497
+ </xs:annotation>
498
+ </xs:enumeration>
464
499
  </xs:restriction>
465
500
  </xs:simpleType>
466
501
  <xs:simpleType name="GreenDealCategoryCode">