bcl 0.2.9 → 0.3.0

Sign up to get free protection for your applications and to get access to all the features.
Binary file
@@ -9,6 +9,260 @@
9
9
  <level_2>
10
10
  <name>Fenestration</name>
11
11
  <description/>
12
+ <level_3>
13
+ <name>Door</name>
14
+ <description/>
15
+ <term>
16
+ <name>OpenStudio Type</name>
17
+ <description>Type of OpenStudio Object</description>
18
+ <row>0</row>
19
+ </term>
20
+ <term>
21
+ <name>Overall U-factor</name>
22
+ <data_type>double</data_type>
23
+ <row>5</row>
24
+ </term>
25
+ <term>
26
+ <name>Standard</name>
27
+ <data_type>enum</data_type>
28
+ <enumerations>
29
+ <enumeration>ASHRAE 90.1-2001</enumeration>
30
+ <enumeration>ASHRAE 90.1-2004</enumeration>
31
+ <enumeration>ASHRAE 90.1-2007</enumeration>
32
+ <enumeration>ASHRAE 90.1-2010</enumeration>
33
+ <enumeration>ASHRAE 90.1-2013</enumeration>
34
+ <enumeration>ASHRAE 189.1-2009</enumeration>
35
+ <enumeration>ASHRAE 189.1-2011</enumeration>
36
+ <enumeration>ASHRAE 50% AEDG Large Hospital</enumeration>
37
+ <enumeration>ASHRAE 50% AEDG Medium to Big Box Retail</enumeration>
38
+ <enumeration>ASHRAE 50% AEDG Small to Medium Office</enumeration>
39
+ <enumeration>ASHRAE 50% AEDG K-12 School</enumeration>
40
+ <enumeration>ASHRAE 30% AEDG Small Office</enumeration>
41
+ <enumeration>ASHRAE 30% AEDG Small Retail</enumeration>
42
+ <enumeration>ASHRAE 30% AEDG K-12 School</enumeration>
43
+ <enumeration>ASHRAE 30% AEDG Small Warehouse and Self-Storage</enumeration>
44
+ <enumeration>ASHRAE 30% AEDG Highway Lodging</enumeration>
45
+ <enumeration>ASHRAE 30% AEDG Small Hospital and Healthcare</enumeration>
46
+ <enumeration>CEC Title 24-2005</enumeration>
47
+ <enumeration>CEC Title 24-2008</enumeration>
48
+ <enumeration>CEC Title 24-2013</enumeration>
49
+ </enumerations>
50
+ <row>454</row>
51
+ </term>
52
+ <term>
53
+ <name>Standard Type</name>
54
+ <data_type>enum</data_type>
55
+ <enumerations>
56
+ <enumeration>Residential</enumeration>
57
+ <enumeration>Nonresidential</enumeration>
58
+ </enumerations>
59
+ <row>455</row>
60
+ </term>
61
+ <term>
62
+ <name>Climate Zone</name>
63
+ <data_type>enum</data_type>
64
+ <enumerations>
65
+ <enumeration>ASHRAE 169-2006-1A</enumeration>
66
+ <enumeration>ASHRAE 169-2006-1B</enumeration>
67
+ <enumeration>ASHRAE 169-2006-2A</enumeration>
68
+ <enumeration>ASHRAE 169-2006-2B</enumeration>
69
+ <enumeration>ASHRAE 169-2006-3A</enumeration>
70
+ <enumeration>ASHRAE 169-2006-3B</enumeration>
71
+ <enumeration>ASHRAE 169-2006-3C</enumeration>
72
+ <enumeration>ASHRAE 169-2006-4A</enumeration>
73
+ <enumeration>ASHRAE 169-2006-4B</enumeration>
74
+ <enumeration>ASHRAE 169-2006-4C</enumeration>
75
+ <enumeration>ASHRAE 169-2006-5A</enumeration>
76
+ <enumeration>ASHRAE 169-2006-5B</enumeration>
77
+ <enumeration>ASHRAE 169-2006-5C</enumeration>
78
+ <enumeration>ASHRAE 169-2006-6A</enumeration>
79
+ <enumeration>ASHRAE 169-2006-6B</enumeration>
80
+ <enumeration>ASHRAE 169-2006-7A</enumeration>
81
+ <enumeration>ASHRAE 169-2006-7B</enumeration>
82
+ <enumeration>ASHRAE 169-2006-8A</enumeration>
83
+ <enumeration>ASHRAE 169-2006-8B</enumeration>
84
+ <enumeration>CEC 2005-1</enumeration>
85
+ <enumeration>CEC 2005-2</enumeration>
86
+ <enumeration>CEC 2005-3</enumeration>
87
+ <enumeration>CEC 2005-4</enumeration>
88
+ <enumeration>CEC 2005-5</enumeration>
89
+ <enumeration>CEC 2005-6</enumeration>
90
+ <enumeration>CEC 2005-7</enumeration>
91
+ <enumeration>CEC 2005-8</enumeration>
92
+ <enumeration>CEC 2005-9</enumeration>
93
+ <enumeration>CEC 2005-10</enumeration>
94
+ <enumeration>CEC 2008-1</enumeration>
95
+ <enumeration>CEC 2008-2</enumeration>
96
+ <enumeration>CEC 2008-3</enumeration>
97
+ <enumeration>CEC 2008-4</enumeration>
98
+ <enumeration>CEC 2008-5</enumeration>
99
+ <enumeration>CEC 2008-6</enumeration>
100
+ <enumeration>CEC 2008-7</enumeration>
101
+ <enumeration>CEC 2008-8</enumeration>
102
+ <enumeration>CEC 2008-9</enumeration>
103
+ <enumeration>CEC 2008-10</enumeration>
104
+ </enumerations>
105
+ <row>456</row>
106
+ </term>
107
+ <term>
108
+ <name>Construction Type</name>
109
+ <data_type>enum</data_type>
110
+ <enumerations>
111
+ <enumeration>Non-Swinging</enumeration>
112
+ <enumeration>Swinging</enumeration>
113
+ </enumerations>
114
+ <row>466</row>
115
+ </term>
116
+ <term>
117
+ <name>Film Coefficients</name>
118
+ <data_type>enum</data_type>
119
+ <enumerations>
120
+ <enumeration>Yes</enumeration>
121
+ <enumeration>No</enumeration>
122
+ </enumerations>
123
+ <row>467</row>
124
+ </term>
125
+ </level_3>
126
+ <level_3>
127
+ <name>Skylight</name>
128
+ <description/>
129
+ <term>
130
+ <name>OpenStudio Type</name>
131
+ <description>Type of OpenStudio Object</description>
132
+ <row>0</row>
133
+ </term>
134
+ <term>
135
+ <name>Overall U-factor</name>
136
+ <data_type>double</data_type>
137
+ <row>5</row>
138
+ </term>
139
+ <term>
140
+ <name>Standard</name>
141
+ <data_type>enum</data_type>
142
+ <enumerations>
143
+ <enumeration>ASHRAE 90.1-2001</enumeration>
144
+ <enumeration>ASHRAE 90.1-2004</enumeration>
145
+ <enumeration>ASHRAE 90.1-2007</enumeration>
146
+ <enumeration>ASHRAE 90.1-2010</enumeration>
147
+ <enumeration>ASHRAE 90.1-2013</enumeration>
148
+ <enumeration>ASHRAE 189.1-2009</enumeration>
149
+ <enumeration>ASHRAE 189.1-2011</enumeration>
150
+ <enumeration>ASHRAE 50% AEDG Large Hospital</enumeration>
151
+ <enumeration>ASHRAE 50% AEDG Medium to Big Box Retail</enumeration>
152
+ <enumeration>ASHRAE 50% AEDG Small to Medium Office</enumeration>
153
+ <enumeration>ASHRAE 50% AEDG K-12 School</enumeration>
154
+ <enumeration>ASHRAE 30% AEDG Small Office</enumeration>
155
+ <enumeration>ASHRAE 30% AEDG Small Retail</enumeration>
156
+ <enumeration>ASHRAE 30% AEDG K-12 School</enumeration>
157
+ <enumeration>ASHRAE 30% AEDG Small Warehouse and Self-Storage</enumeration>
158
+ <enumeration>ASHRAE 30% AEDG Highway Lodging</enumeration>
159
+ <enumeration>ASHRAE 30% AEDG Small Hospital and Healthcare</enumeration>
160
+ <enumeration>CEC Title 24-2005</enumeration>
161
+ <enumeration>CEC Title 24-2008</enumeration>
162
+ <enumeration>CEC Title 24-2013</enumeration>
163
+ </enumerations>
164
+ <row>454</row>
165
+ </term>
166
+ <term>
167
+ <name>Standard Type</name>
168
+ <data_type>enum</data_type>
169
+ <enumerations>
170
+ <enumeration>Residential</enumeration>
171
+ <enumeration>Nonresidential</enumeration>
172
+ </enumerations>
173
+ <row>455</row>
174
+ </term>
175
+ <term>
176
+ <name>Climate Zone</name>
177
+ <data_type>enum</data_type>
178
+ <enumerations>
179
+ <enumeration>ASHRAE 169-2006-1A</enumeration>
180
+ <enumeration>ASHRAE 169-2006-1B</enumeration>
181
+ <enumeration>ASHRAE 169-2006-2A</enumeration>
182
+ <enumeration>ASHRAE 169-2006-2B</enumeration>
183
+ <enumeration>ASHRAE 169-2006-3A</enumeration>
184
+ <enumeration>ASHRAE 169-2006-3B</enumeration>
185
+ <enumeration>ASHRAE 169-2006-3C</enumeration>
186
+ <enumeration>ASHRAE 169-2006-4A</enumeration>
187
+ <enumeration>ASHRAE 169-2006-4B</enumeration>
188
+ <enumeration>ASHRAE 169-2006-4C</enumeration>
189
+ <enumeration>ASHRAE 169-2006-5A</enumeration>
190
+ <enumeration>ASHRAE 169-2006-5B</enumeration>
191
+ <enumeration>ASHRAE 169-2006-5C</enumeration>
192
+ <enumeration>ASHRAE 169-2006-6A</enumeration>
193
+ <enumeration>ASHRAE 169-2006-6B</enumeration>
194
+ <enumeration>ASHRAE 169-2006-7A</enumeration>
195
+ <enumeration>ASHRAE 169-2006-7B</enumeration>
196
+ <enumeration>ASHRAE 169-2006-8A</enumeration>
197
+ <enumeration>ASHRAE 169-2006-8B</enumeration>
198
+ <enumeration>CEC 2005-1</enumeration>
199
+ <enumeration>CEC 2005-2</enumeration>
200
+ <enumeration>CEC 2005-3</enumeration>
201
+ <enumeration>CEC 2005-4</enumeration>
202
+ <enumeration>CEC 2005-5</enumeration>
203
+ <enumeration>CEC 2005-6</enumeration>
204
+ <enumeration>CEC 2005-7</enumeration>
205
+ <enumeration>CEC 2005-8</enumeration>
206
+ <enumeration>CEC 2005-9</enumeration>
207
+ <enumeration>CEC 2005-10</enumeration>
208
+ <enumeration>CEC 2008-1</enumeration>
209
+ <enumeration>CEC 2008-2</enumeration>
210
+ <enumeration>CEC 2008-3</enumeration>
211
+ <enumeration>CEC 2008-4</enumeration>
212
+ <enumeration>CEC 2008-5</enumeration>
213
+ <enumeration>CEC 2008-6</enumeration>
214
+ <enumeration>CEC 2008-7</enumeration>
215
+ <enumeration>CEC 2008-8</enumeration>
216
+ <enumeration>CEC 2008-9</enumeration>
217
+ <enumeration>CEC 2008-10</enumeration>
218
+ </enumerations>
219
+ <row>456</row>
220
+ </term>
221
+ <term>
222
+ <name>Construction Type</name>
223
+ <data_type>enum</data_type>
224
+ <enumerations>
225
+ <enumeration>All Skylights without Curb</enumeration>
226
+ <enumeration>Glass Skylight with Curb</enumeration>
227
+ <enumeration>Plastic Skylight with Curb</enumeration>
228
+ </enumerations>
229
+ <row>469</row>
230
+ </term>
231
+ <term>
232
+ <name>Solar Heat Gain Coefficient</name>
233
+ <abbr>SHGC</abbr>
234
+ <data_type>double</data_type>
235
+ <row>470</row>
236
+ </term>
237
+ <term>
238
+ <name>Visible Light Transmittance</name>
239
+ <abbr>VLT</abbr>
240
+ <data_type>double</data_type>
241
+ <row>471</row>
242
+ </term>
243
+ <term>
244
+ <name>Overall Conductivity</name>
245
+ <abbr>Overall U-factor</abbr>
246
+ <description>Thermal conductivity of material layer at a mean temperature of 75&#176;F under dry conditions.</description>
247
+ <data_type>double</data_type>
248
+ <ip_written>British Thermal Units Inches per Hour Square Foot Degree Rankine</ip_written>
249
+ <ip_symbol>Btu*in/hr*ft^2*R</ip_symbol>
250
+ <si_written>Watts per Meter Degree Kelvin</si_written>
251
+ <si_symbol>W/m*K</si_symbol>
252
+ <row>472</row>
253
+ <unit_conversion>IP == 6.93347 * SI</unit_conversion>
254
+ </term>
255
+ <term>
256
+ <name>Minimum Glazing Fraction</name>
257
+ <data_type>double</data_type>
258
+ <row>473</row>
259
+ </term>
260
+ <term>
261
+ <name>Maximum Glazing Fraction</name>
262
+ <data_type>double</data_type>
263
+ <row>474</row>
264
+ </term>
265
+ </level_3>
12
266
  <level_3>
13
267
  <name>Window</name>
14
268
  <description/>
@@ -49,6 +303,1019 @@
49
303
  <data_type>double</data_type>
50
304
  <row>11</row>
51
305
  </term>
306
+ <term>
307
+ <name>Standard</name>
308
+ <data_type>enum</data_type>
309
+ <enumerations>
310
+ <enumeration>ASHRAE 90.1-2001</enumeration>
311
+ <enumeration>ASHRAE 90.1-2004</enumeration>
312
+ <enumeration>ASHRAE 90.1-2007</enumeration>
313
+ <enumeration>ASHRAE 90.1-2010</enumeration>
314
+ <enumeration>ASHRAE 90.1-2013</enumeration>
315
+ <enumeration>ASHRAE 189.1-2009</enumeration>
316
+ <enumeration>ASHRAE 189.1-2011</enumeration>
317
+ <enumeration>ASHRAE 50% AEDG Large Hospital</enumeration>
318
+ <enumeration>ASHRAE 50% AEDG Medium to Big Box Retail</enumeration>
319
+ <enumeration>ASHRAE 50% AEDG Small to Medium Office</enumeration>
320
+ <enumeration>ASHRAE 50% AEDG K-12 School</enumeration>
321
+ <enumeration>ASHRAE 30% AEDG Small Office</enumeration>
322
+ <enumeration>ASHRAE 30% AEDG Small Retail</enumeration>
323
+ <enumeration>ASHRAE 30% AEDG K-12 School</enumeration>
324
+ <enumeration>ASHRAE 30% AEDG Small Warehouse and Self-Storage</enumeration>
325
+ <enumeration>ASHRAE 30% AEDG Highway Lodging</enumeration>
326
+ <enumeration>ASHRAE 30% AEDG Small Hospital and Healthcare</enumeration>
327
+ <enumeration>CEC Title 24-2005</enumeration>
328
+ <enumeration>CEC Title 24-2008</enumeration>
329
+ <enumeration>CEC Title 24-2013</enumeration>
330
+ </enumerations>
331
+ <row>454</row>
332
+ </term>
333
+ <term>
334
+ <name>Standard Type</name>
335
+ <data_type>enum</data_type>
336
+ <enumerations>
337
+ <enumeration>Residential</enumeration>
338
+ <enumeration>Nonresidential</enumeration>
339
+ </enumerations>
340
+ <row>455</row>
341
+ </term>
342
+ <term>
343
+ <name>Climate Zone</name>
344
+ <data_type>enum</data_type>
345
+ <enumerations>
346
+ <enumeration>ASHRAE 169-2006-1A</enumeration>
347
+ <enumeration>ASHRAE 169-2006-1B</enumeration>
348
+ <enumeration>ASHRAE 169-2006-2A</enumeration>
349
+ <enumeration>ASHRAE 169-2006-2B</enumeration>
350
+ <enumeration>ASHRAE 169-2006-3A</enumeration>
351
+ <enumeration>ASHRAE 169-2006-3B</enumeration>
352
+ <enumeration>ASHRAE 169-2006-3C</enumeration>
353
+ <enumeration>ASHRAE 169-2006-4A</enumeration>
354
+ <enumeration>ASHRAE 169-2006-4B</enumeration>
355
+ <enumeration>ASHRAE 169-2006-4C</enumeration>
356
+ <enumeration>ASHRAE 169-2006-5A</enumeration>
357
+ <enumeration>ASHRAE 169-2006-5B</enumeration>
358
+ <enumeration>ASHRAE 169-2006-5C</enumeration>
359
+ <enumeration>ASHRAE 169-2006-6A</enumeration>
360
+ <enumeration>ASHRAE 169-2006-6B</enumeration>
361
+ <enumeration>ASHRAE 169-2006-7A</enumeration>
362
+ <enumeration>ASHRAE 169-2006-7B</enumeration>
363
+ <enumeration>ASHRAE 169-2006-8A</enumeration>
364
+ <enumeration>ASHRAE 169-2006-8B</enumeration>
365
+ <enumeration>CEC 2005-1</enumeration>
366
+ <enumeration>CEC 2005-2</enumeration>
367
+ <enumeration>CEC 2005-3</enumeration>
368
+ <enumeration>CEC 2005-4</enumeration>
369
+ <enumeration>CEC 2005-5</enumeration>
370
+ <enumeration>CEC 2005-6</enumeration>
371
+ <enumeration>CEC 2005-7</enumeration>
372
+ <enumeration>CEC 2005-8</enumeration>
373
+ <enumeration>CEC 2005-9</enumeration>
374
+ <enumeration>CEC 2005-10</enumeration>
375
+ <enumeration>CEC 2008-1</enumeration>
376
+ <enumeration>CEC 2008-2</enumeration>
377
+ <enumeration>CEC 2008-3</enumeration>
378
+ <enumeration>CEC 2008-4</enumeration>
379
+ <enumeration>CEC 2008-5</enumeration>
380
+ <enumeration>CEC 2008-6</enumeration>
381
+ <enumeration>CEC 2008-7</enumeration>
382
+ <enumeration>CEC 2008-8</enumeration>
383
+ <enumeration>CEC 2008-9</enumeration>
384
+ <enumeration>CEC 2008-10</enumeration>
385
+ </enumerations>
386
+ <row>456</row>
387
+ </term>
388
+ <term>
389
+ <name>Construction Type</name>
390
+ <data_type>enum</data_type>
391
+ <enumerations>
392
+ <enumeration>Metal Framing (All Other)</enumeration>
393
+ <enumeration>Metal Framing (Curtainwall/Storefront)</enumeration>
394
+ <enumeration>Metal Framing (Entrance Door)</enumeration>
395
+ <enumeration>Non-Metal Framing</enumeration>
396
+ <enumeration>Fixed</enumeration>
397
+ </enumerations>
398
+ <row>459</row>
399
+ </term>
400
+ <term>
401
+ <name>Solar Heat Gain Coefficient</name>
402
+ <abbr>SHGC</abbr>
403
+ <data_type>double</data_type>
404
+ <row>460</row>
405
+ </term>
406
+ <term>
407
+ <name>Visible Light Transmittance</name>
408
+ <abbr>VLT</abbr>
409
+ <data_type>double</data_type>
410
+ <row>461</row>
411
+ </term>
412
+ <term>
413
+ <name>Overall Conductivity</name>
414
+ <abbr>Overall U-factor</abbr>
415
+ <description>Thermal conductivity of material layer at a mean temperature of 75&#176;F under dry conditions.</description>
416
+ <data_type>double</data_type>
417
+ <ip_written>British Thermal Units Inches per Hour Square Foot Degree Rankine</ip_written>
418
+ <ip_symbol>Btu*in/hr*ft^2*R</ip_symbol>
419
+ <si_written>Watts per Meter Degree Kelvin</si_written>
420
+ <si_symbol>W/m*K</si_symbol>
421
+ <row>462</row>
422
+ <unit_conversion>IP == 6.93347 * SI</unit_conversion>
423
+ </term>
424
+ <term>
425
+ <name>Minimum Glazing Fraction</name>
426
+ <data_type>double</data_type>
427
+ <row>463</row>
428
+ </term>
429
+ <term>
430
+ <name>Maximum Glazing Fraction</name>
431
+ <data_type>double</data_type>
432
+ <row>464</row>
433
+ </term>
434
+ </level_3>
435
+ </level_2>
436
+ <level_2>
437
+ <name>Floor</name>
438
+ <description/>
439
+ <level_3>
440
+ <name>Attic Floor</name>
441
+ <description/>
442
+ <term>
443
+ <name>OpenStudio Type</name>
444
+ <description>Type of OpenStudio Object</description>
445
+ <row>0</row>
446
+ </term>
447
+ <term>
448
+ <name>Standard</name>
449
+ <data_type>enum</data_type>
450
+ <enumerations>
451
+ <enumeration>ASHRAE 90.1-2001</enumeration>
452
+ <enumeration>ASHRAE 90.1-2004</enumeration>
453
+ <enumeration>ASHRAE 90.1-2007</enumeration>
454
+ <enumeration>ASHRAE 90.1-2010</enumeration>
455
+ <enumeration>ASHRAE 90.1-2013</enumeration>
456
+ <enumeration>ASHRAE 189.1-2009</enumeration>
457
+ <enumeration>ASHRAE 189.1-2011</enumeration>
458
+ <enumeration>ASHRAE 50% AEDG Large Hospital</enumeration>
459
+ <enumeration>ASHRAE 50% AEDG Medium to Big Box Retail</enumeration>
460
+ <enumeration>ASHRAE 50% AEDG Small to Medium Office</enumeration>
461
+ <enumeration>ASHRAE 50% AEDG K-12 School</enumeration>
462
+ <enumeration>ASHRAE 30% AEDG Small Office</enumeration>
463
+ <enumeration>ASHRAE 30% AEDG Small Retail</enumeration>
464
+ <enumeration>ASHRAE 30% AEDG K-12 School</enumeration>
465
+ <enumeration>ASHRAE 30% AEDG Small Warehouse and Self-Storage</enumeration>
466
+ <enumeration>ASHRAE 30% AEDG Highway Lodging</enumeration>
467
+ <enumeration>ASHRAE 30% AEDG Small Hospital and Healthcare</enumeration>
468
+ <enumeration>CEC Title 24-2005</enumeration>
469
+ <enumeration>CEC Title 24-2008</enumeration>
470
+ <enumeration>CEC Title 24-2013</enumeration>
471
+ </enumerations>
472
+ <row>454</row>
473
+ </term>
474
+ <term>
475
+ <name>Standard Type</name>
476
+ <data_type>enum</data_type>
477
+ <enumerations>
478
+ <enumeration>Residential</enumeration>
479
+ <enumeration>Nonresidential</enumeration>
480
+ </enumerations>
481
+ <row>455</row>
482
+ </term>
483
+ <term>
484
+ <name>Climate Zone</name>
485
+ <data_type>enum</data_type>
486
+ <enumerations>
487
+ <enumeration>ASHRAE 169-2006-1A</enumeration>
488
+ <enumeration>ASHRAE 169-2006-1B</enumeration>
489
+ <enumeration>ASHRAE 169-2006-2A</enumeration>
490
+ <enumeration>ASHRAE 169-2006-2B</enumeration>
491
+ <enumeration>ASHRAE 169-2006-3A</enumeration>
492
+ <enumeration>ASHRAE 169-2006-3B</enumeration>
493
+ <enumeration>ASHRAE 169-2006-3C</enumeration>
494
+ <enumeration>ASHRAE 169-2006-4A</enumeration>
495
+ <enumeration>ASHRAE 169-2006-4B</enumeration>
496
+ <enumeration>ASHRAE 169-2006-4C</enumeration>
497
+ <enumeration>ASHRAE 169-2006-5A</enumeration>
498
+ <enumeration>ASHRAE 169-2006-5B</enumeration>
499
+ <enumeration>ASHRAE 169-2006-5C</enumeration>
500
+ <enumeration>ASHRAE 169-2006-6A</enumeration>
501
+ <enumeration>ASHRAE 169-2006-6B</enumeration>
502
+ <enumeration>ASHRAE 169-2006-7A</enumeration>
503
+ <enumeration>ASHRAE 169-2006-7B</enumeration>
504
+ <enumeration>ASHRAE 169-2006-8A</enumeration>
505
+ <enumeration>ASHRAE 169-2006-8B</enumeration>
506
+ <enumeration>CEC 2005-1</enumeration>
507
+ <enumeration>CEC 2005-2</enumeration>
508
+ <enumeration>CEC 2005-3</enumeration>
509
+ <enumeration>CEC 2005-4</enumeration>
510
+ <enumeration>CEC 2005-5</enumeration>
511
+ <enumeration>CEC 2005-6</enumeration>
512
+ <enumeration>CEC 2005-7</enumeration>
513
+ <enumeration>CEC 2005-8</enumeration>
514
+ <enumeration>CEC 2005-9</enumeration>
515
+ <enumeration>CEC 2005-10</enumeration>
516
+ <enumeration>CEC 2008-1</enumeration>
517
+ <enumeration>CEC 2008-2</enumeration>
518
+ <enumeration>CEC 2008-3</enumeration>
519
+ <enumeration>CEC 2008-4</enumeration>
520
+ <enumeration>CEC 2008-5</enumeration>
521
+ <enumeration>CEC 2008-6</enumeration>
522
+ <enumeration>CEC 2008-7</enumeration>
523
+ <enumeration>CEC 2008-8</enumeration>
524
+ <enumeration>CEC 2008-9</enumeration>
525
+ <enumeration>CEC 2008-10</enumeration>
526
+ </enumerations>
527
+ <row>456</row>
528
+ </term>
529
+ <term>
530
+ <name>Film Coefficients</name>
531
+ <data_type>enum</data_type>
532
+ <enumerations>
533
+ <enumeration>Yes</enumeration>
534
+ <enumeration>No</enumeration>
535
+ </enumerations>
536
+ <row>484</row>
537
+ </term>
538
+ <term>
539
+ <name>Resistance</name>
540
+ <description>Thermal resistance of material layer at a mean temperature of 75&#176;F under dry conditions; no film coefficients included.</description>
541
+ <data_type>double</data_type>
542
+ <ip_written>Hours Square Feet Degrees Rankine per British Thermal Unit</ip_written>
543
+ <ip_symbol>hr*ft^2*R/Btu</ip_symbol>
544
+ <si_written>Square Meters Degree Kelvin per Watt</si_written>
545
+ <si_symbol>m^2*K/W</si_symbol>
546
+ <row>485</row>
547
+ <unit_conversion>IP = 5.678263 * SI</unit_conversion>
548
+ </term>
549
+ <term>
550
+ <name>Construction Type</name>
551
+ <data_type>enum</data_type>
552
+ <enumerations>
553
+ <enumeration>Attic Floor</enumeration>
554
+ </enumerations>
555
+ <row>489</row>
556
+ </term>
557
+ <term>
558
+ <name>Insulation Minimum R-Value (ft^2*F*hr/Btu)</name>
559
+ <abbr>Insulation Minimum Thermal Resistance</abbr>
560
+ <description>R-13 + R-7.5 ci or R-5.7 ci</description>
561
+ <data_type>string</data_type>
562
+ <row>490</row>
563
+ </term>
564
+ </level_3>
565
+ <level_3>
566
+ <name>Exposed Floor</name>
567
+ <description/>
568
+ <term>
569
+ <name>OpenStudio Type</name>
570
+ <description>Type of OpenStudio Object</description>
571
+ <row>0</row>
572
+ </term>
573
+ <term>
574
+ <name>Standard</name>
575
+ <data_type>enum</data_type>
576
+ <enumerations>
577
+ <enumeration>ASHRAE 90.1-2001</enumeration>
578
+ <enumeration>ASHRAE 90.1-2004</enumeration>
579
+ <enumeration>ASHRAE 90.1-2007</enumeration>
580
+ <enumeration>ASHRAE 90.1-2010</enumeration>
581
+ <enumeration>ASHRAE 90.1-2013</enumeration>
582
+ <enumeration>ASHRAE 189.1-2009</enumeration>
583
+ <enumeration>ASHRAE 189.1-2011</enumeration>
584
+ <enumeration>ASHRAE 50% AEDG Large Hospital</enumeration>
585
+ <enumeration>ASHRAE 50% AEDG Medium to Big Box Retail</enumeration>
586
+ <enumeration>ASHRAE 50% AEDG Small to Medium Office</enumeration>
587
+ <enumeration>ASHRAE 50% AEDG K-12 School</enumeration>
588
+ <enumeration>ASHRAE 30% AEDG Small Office</enumeration>
589
+ <enumeration>ASHRAE 30% AEDG Small Retail</enumeration>
590
+ <enumeration>ASHRAE 30% AEDG K-12 School</enumeration>
591
+ <enumeration>ASHRAE 30% AEDG Small Warehouse and Self-Storage</enumeration>
592
+ <enumeration>ASHRAE 30% AEDG Highway Lodging</enumeration>
593
+ <enumeration>ASHRAE 30% AEDG Small Hospital and Healthcare</enumeration>
594
+ <enumeration>CEC Title 24-2005</enumeration>
595
+ <enumeration>CEC Title 24-2008</enumeration>
596
+ <enumeration>CEC Title 24-2013</enumeration>
597
+ </enumerations>
598
+ <row>454</row>
599
+ </term>
600
+ <term>
601
+ <name>Standard Type</name>
602
+ <data_type>enum</data_type>
603
+ <enumerations>
604
+ <enumeration>Residential</enumeration>
605
+ <enumeration>Nonresidential</enumeration>
606
+ </enumerations>
607
+ <row>455</row>
608
+ </term>
609
+ <term>
610
+ <name>Climate Zone</name>
611
+ <data_type>enum</data_type>
612
+ <enumerations>
613
+ <enumeration>ASHRAE 169-2006-1A</enumeration>
614
+ <enumeration>ASHRAE 169-2006-1B</enumeration>
615
+ <enumeration>ASHRAE 169-2006-2A</enumeration>
616
+ <enumeration>ASHRAE 169-2006-2B</enumeration>
617
+ <enumeration>ASHRAE 169-2006-3A</enumeration>
618
+ <enumeration>ASHRAE 169-2006-3B</enumeration>
619
+ <enumeration>ASHRAE 169-2006-3C</enumeration>
620
+ <enumeration>ASHRAE 169-2006-4A</enumeration>
621
+ <enumeration>ASHRAE 169-2006-4B</enumeration>
622
+ <enumeration>ASHRAE 169-2006-4C</enumeration>
623
+ <enumeration>ASHRAE 169-2006-5A</enumeration>
624
+ <enumeration>ASHRAE 169-2006-5B</enumeration>
625
+ <enumeration>ASHRAE 169-2006-5C</enumeration>
626
+ <enumeration>ASHRAE 169-2006-6A</enumeration>
627
+ <enumeration>ASHRAE 169-2006-6B</enumeration>
628
+ <enumeration>ASHRAE 169-2006-7A</enumeration>
629
+ <enumeration>ASHRAE 169-2006-7B</enumeration>
630
+ <enumeration>ASHRAE 169-2006-8A</enumeration>
631
+ <enumeration>ASHRAE 169-2006-8B</enumeration>
632
+ <enumeration>CEC 2005-1</enumeration>
633
+ <enumeration>CEC 2005-2</enumeration>
634
+ <enumeration>CEC 2005-3</enumeration>
635
+ <enumeration>CEC 2005-4</enumeration>
636
+ <enumeration>CEC 2005-5</enumeration>
637
+ <enumeration>CEC 2005-6</enumeration>
638
+ <enumeration>CEC 2005-7</enumeration>
639
+ <enumeration>CEC 2005-8</enumeration>
640
+ <enumeration>CEC 2005-9</enumeration>
641
+ <enumeration>CEC 2005-10</enumeration>
642
+ <enumeration>CEC 2008-1</enumeration>
643
+ <enumeration>CEC 2008-2</enumeration>
644
+ <enumeration>CEC 2008-3</enumeration>
645
+ <enumeration>CEC 2008-4</enumeration>
646
+ <enumeration>CEC 2008-5</enumeration>
647
+ <enumeration>CEC 2008-6</enumeration>
648
+ <enumeration>CEC 2008-7</enumeration>
649
+ <enumeration>CEC 2008-8</enumeration>
650
+ <enumeration>CEC 2008-9</enumeration>
651
+ <enumeration>CEC 2008-10</enumeration>
652
+ </enumerations>
653
+ <row>456</row>
654
+ </term>
655
+ <term>
656
+ <name>Film Coefficients</name>
657
+ <data_type>enum</data_type>
658
+ <enumerations>
659
+ <enumeration>Yes</enumeration>
660
+ <enumeration>No</enumeration>
661
+ </enumerations>
662
+ <row>484</row>
663
+ </term>
664
+ <term>
665
+ <name>Resistance</name>
666
+ <description>Thermal resistance of material layer at a mean temperature of 75&#176;F under dry conditions; no film coefficients included.</description>
667
+ <data_type>double</data_type>
668
+ <ip_written>Hours Square Feet Degrees Rankine per British Thermal Unit</ip_written>
669
+ <ip_symbol>hr*ft^2*R/Btu</ip_symbol>
670
+ <si_written>Square Meters Degree Kelvin per Watt</si_written>
671
+ <si_symbol>m^2*K/W</si_symbol>
672
+ <row>485</row>
673
+ <unit_conversion>IP = 5.678263 * SI</unit_conversion>
674
+ </term>
675
+ <term>
676
+ <name>Construction Type</name>
677
+ <data_type>enum</data_type>
678
+ <enumerations>
679
+ <enumeration>Mass</enumeration>
680
+ </enumerations>
681
+ <row>492</row>
682
+ </term>
683
+ <term>
684
+ <name>Insulation Minimum R-Value (ft^2*F*hr/Btu)</name>
685
+ <abbr>Insulation Minimum Thermal Resistance</abbr>
686
+ <description>R-13 + R-7.5 ci or R-5.7 ci</description>
687
+ <data_type>string</data_type>
688
+ <row>493</row>
689
+ </term>
690
+ </level_3>
691
+ <level_3>
692
+ <name>Exterior Slab</name>
693
+ <description/>
694
+ <term>
695
+ <name>OpenStudio Type</name>
696
+ <description>Type of OpenStudio Object</description>
697
+ <row>0</row>
698
+ </term>
699
+ <term>
700
+ <name>Standard</name>
701
+ <data_type>enum</data_type>
702
+ <enumerations>
703
+ <enumeration>ASHRAE 90.1-2001</enumeration>
704
+ <enumeration>ASHRAE 90.1-2004</enumeration>
705
+ <enumeration>ASHRAE 90.1-2007</enumeration>
706
+ <enumeration>ASHRAE 90.1-2010</enumeration>
707
+ <enumeration>ASHRAE 90.1-2013</enumeration>
708
+ <enumeration>ASHRAE 189.1-2009</enumeration>
709
+ <enumeration>ASHRAE 189.1-2011</enumeration>
710
+ <enumeration>ASHRAE 50% AEDG Large Hospital</enumeration>
711
+ <enumeration>ASHRAE 50% AEDG Medium to Big Box Retail</enumeration>
712
+ <enumeration>ASHRAE 50% AEDG Small to Medium Office</enumeration>
713
+ <enumeration>ASHRAE 50% AEDG K-12 School</enumeration>
714
+ <enumeration>ASHRAE 30% AEDG Small Office</enumeration>
715
+ <enumeration>ASHRAE 30% AEDG Small Retail</enumeration>
716
+ <enumeration>ASHRAE 30% AEDG K-12 School</enumeration>
717
+ <enumeration>ASHRAE 30% AEDG Small Warehouse and Self-Storage</enumeration>
718
+ <enumeration>ASHRAE 30% AEDG Highway Lodging</enumeration>
719
+ <enumeration>ASHRAE 30% AEDG Small Hospital and Healthcare</enumeration>
720
+ <enumeration>CEC Title 24-2005</enumeration>
721
+ <enumeration>CEC Title 24-2008</enumeration>
722
+ <enumeration>CEC Title 24-2013</enumeration>
723
+ </enumerations>
724
+ <row>454</row>
725
+ </term>
726
+ <term>
727
+ <name>Standard Type</name>
728
+ <data_type>enum</data_type>
729
+ <enumerations>
730
+ <enumeration>Residential</enumeration>
731
+ <enumeration>Nonresidential</enumeration>
732
+ </enumerations>
733
+ <row>455</row>
734
+ </term>
735
+ <term>
736
+ <name>Climate Zone</name>
737
+ <data_type>enum</data_type>
738
+ <enumerations>
739
+ <enumeration>ASHRAE 169-2006-1A</enumeration>
740
+ <enumeration>ASHRAE 169-2006-1B</enumeration>
741
+ <enumeration>ASHRAE 169-2006-2A</enumeration>
742
+ <enumeration>ASHRAE 169-2006-2B</enumeration>
743
+ <enumeration>ASHRAE 169-2006-3A</enumeration>
744
+ <enumeration>ASHRAE 169-2006-3B</enumeration>
745
+ <enumeration>ASHRAE 169-2006-3C</enumeration>
746
+ <enumeration>ASHRAE 169-2006-4A</enumeration>
747
+ <enumeration>ASHRAE 169-2006-4B</enumeration>
748
+ <enumeration>ASHRAE 169-2006-4C</enumeration>
749
+ <enumeration>ASHRAE 169-2006-5A</enumeration>
750
+ <enumeration>ASHRAE 169-2006-5B</enumeration>
751
+ <enumeration>ASHRAE 169-2006-5C</enumeration>
752
+ <enumeration>ASHRAE 169-2006-6A</enumeration>
753
+ <enumeration>ASHRAE 169-2006-6B</enumeration>
754
+ <enumeration>ASHRAE 169-2006-7A</enumeration>
755
+ <enumeration>ASHRAE 169-2006-7B</enumeration>
756
+ <enumeration>ASHRAE 169-2006-8A</enumeration>
757
+ <enumeration>ASHRAE 169-2006-8B</enumeration>
758
+ <enumeration>CEC 2005-1</enumeration>
759
+ <enumeration>CEC 2005-2</enumeration>
760
+ <enumeration>CEC 2005-3</enumeration>
761
+ <enumeration>CEC 2005-4</enumeration>
762
+ <enumeration>CEC 2005-5</enumeration>
763
+ <enumeration>CEC 2005-6</enumeration>
764
+ <enumeration>CEC 2005-7</enumeration>
765
+ <enumeration>CEC 2005-8</enumeration>
766
+ <enumeration>CEC 2005-9</enumeration>
767
+ <enumeration>CEC 2005-10</enumeration>
768
+ <enumeration>CEC 2008-1</enumeration>
769
+ <enumeration>CEC 2008-2</enumeration>
770
+ <enumeration>CEC 2008-3</enumeration>
771
+ <enumeration>CEC 2008-4</enumeration>
772
+ <enumeration>CEC 2008-5</enumeration>
773
+ <enumeration>CEC 2008-6</enumeration>
774
+ <enumeration>CEC 2008-7</enumeration>
775
+ <enumeration>CEC 2008-8</enumeration>
776
+ <enumeration>CEC 2008-9</enumeration>
777
+ <enumeration>CEC 2008-10</enumeration>
778
+ </enumerations>
779
+ <row>456</row>
780
+ </term>
781
+ <term>
782
+ <name>Film Coefficients</name>
783
+ <data_type>enum</data_type>
784
+ <enumerations>
785
+ <enumeration>Yes</enumeration>
786
+ <enumeration>No</enumeration>
787
+ </enumerations>
788
+ <row>484</row>
789
+ </term>
790
+ <term>
791
+ <name>Resistance</name>
792
+ <description>Thermal resistance of material layer at a mean temperature of 75&#176;F under dry conditions; no film coefficients included.</description>
793
+ <data_type>double</data_type>
794
+ <ip_written>Hours Square Feet Degrees Rankine per British Thermal Unit</ip_written>
795
+ <ip_symbol>hr*ft^2*R/Btu</ip_symbol>
796
+ <si_written>Square Meters Degree Kelvin per Watt</si_written>
797
+ <si_symbol>m^2*K/W</si_symbol>
798
+ <row>485</row>
799
+ <unit_conversion>IP = 5.678263 * SI</unit_conversion>
800
+ </term>
801
+ <term>
802
+ <name>Construction Type</name>
803
+ <data_type>enum</data_type>
804
+ <enumerations>
805
+ <enumeration>Unheated - 4in Slab with Carpet</enumeration>
806
+ <enumeration>Unheated - 4in Slab without Carpet</enumeration>
807
+ <enumeration>Unheated - 8in Slab with Carpet</enumeration>
808
+ <enumeration>Unheated - 8in Slab without Carpet</enumeration>
809
+ </enumerations>
810
+ <row>487</row>
811
+ </term>
812
+ </level_3>
813
+ </level_2>
814
+ <level_2>
815
+ <name>Roof Ceiling</name>
816
+ <description/>
817
+ <level_3>
818
+ <name>Attic Roof</name>
819
+ <description/>
820
+ <term>
821
+ <name>OpenStudio Type</name>
822
+ <description>Type of OpenStudio Object</description>
823
+ <row>0</row>
824
+ </term>
825
+ <term>
826
+ <name>Standard</name>
827
+ <data_type>enum</data_type>
828
+ <enumerations>
829
+ <enumeration>ASHRAE 90.1-2001</enumeration>
830
+ <enumeration>ASHRAE 90.1-2004</enumeration>
831
+ <enumeration>ASHRAE 90.1-2007</enumeration>
832
+ <enumeration>ASHRAE 90.1-2010</enumeration>
833
+ <enumeration>ASHRAE 90.1-2013</enumeration>
834
+ <enumeration>ASHRAE 189.1-2009</enumeration>
835
+ <enumeration>ASHRAE 189.1-2011</enumeration>
836
+ <enumeration>ASHRAE 50% AEDG Large Hospital</enumeration>
837
+ <enumeration>ASHRAE 50% AEDG Medium to Big Box Retail</enumeration>
838
+ <enumeration>ASHRAE 50% AEDG Small to Medium Office</enumeration>
839
+ <enumeration>ASHRAE 50% AEDG K-12 School</enumeration>
840
+ <enumeration>ASHRAE 30% AEDG Small Office</enumeration>
841
+ <enumeration>ASHRAE 30% AEDG Small Retail</enumeration>
842
+ <enumeration>ASHRAE 30% AEDG K-12 School</enumeration>
843
+ <enumeration>ASHRAE 30% AEDG Small Warehouse and Self-Storage</enumeration>
844
+ <enumeration>ASHRAE 30% AEDG Highway Lodging</enumeration>
845
+ <enumeration>ASHRAE 30% AEDG Small Hospital and Healthcare</enumeration>
846
+ <enumeration>CEC Title 24-2005</enumeration>
847
+ <enumeration>CEC Title 24-2008</enumeration>
848
+ <enumeration>CEC Title 24-2013</enumeration>
849
+ </enumerations>
850
+ <row>454</row>
851
+ </term>
852
+ <term>
853
+ <name>Standard Type</name>
854
+ <data_type>enum</data_type>
855
+ <enumerations>
856
+ <enumeration>Residential</enumeration>
857
+ <enumeration>Nonresidential</enumeration>
858
+ </enumerations>
859
+ <row>455</row>
860
+ </term>
861
+ <term>
862
+ <name>Climate Zone</name>
863
+ <data_type>enum</data_type>
864
+ <enumerations>
865
+ <enumeration>ASHRAE 169-2006-1A</enumeration>
866
+ <enumeration>ASHRAE 169-2006-1B</enumeration>
867
+ <enumeration>ASHRAE 169-2006-2A</enumeration>
868
+ <enumeration>ASHRAE 169-2006-2B</enumeration>
869
+ <enumeration>ASHRAE 169-2006-3A</enumeration>
870
+ <enumeration>ASHRAE 169-2006-3B</enumeration>
871
+ <enumeration>ASHRAE 169-2006-3C</enumeration>
872
+ <enumeration>ASHRAE 169-2006-4A</enumeration>
873
+ <enumeration>ASHRAE 169-2006-4B</enumeration>
874
+ <enumeration>ASHRAE 169-2006-4C</enumeration>
875
+ <enumeration>ASHRAE 169-2006-5A</enumeration>
876
+ <enumeration>ASHRAE 169-2006-5B</enumeration>
877
+ <enumeration>ASHRAE 169-2006-5C</enumeration>
878
+ <enumeration>ASHRAE 169-2006-6A</enumeration>
879
+ <enumeration>ASHRAE 169-2006-6B</enumeration>
880
+ <enumeration>ASHRAE 169-2006-7A</enumeration>
881
+ <enumeration>ASHRAE 169-2006-7B</enumeration>
882
+ <enumeration>ASHRAE 169-2006-8A</enumeration>
883
+ <enumeration>ASHRAE 169-2006-8B</enumeration>
884
+ <enumeration>CEC 2005-1</enumeration>
885
+ <enumeration>CEC 2005-2</enumeration>
886
+ <enumeration>CEC 2005-3</enumeration>
887
+ <enumeration>CEC 2005-4</enumeration>
888
+ <enumeration>CEC 2005-5</enumeration>
889
+ <enumeration>CEC 2005-6</enumeration>
890
+ <enumeration>CEC 2005-7</enumeration>
891
+ <enumeration>CEC 2005-8</enumeration>
892
+ <enumeration>CEC 2005-9</enumeration>
893
+ <enumeration>CEC 2005-10</enumeration>
894
+ <enumeration>CEC 2008-1</enumeration>
895
+ <enumeration>CEC 2008-2</enumeration>
896
+ <enumeration>CEC 2008-3</enumeration>
897
+ <enumeration>CEC 2008-4</enumeration>
898
+ <enumeration>CEC 2008-5</enumeration>
899
+ <enumeration>CEC 2008-6</enumeration>
900
+ <enumeration>CEC 2008-7</enumeration>
901
+ <enumeration>CEC 2008-8</enumeration>
902
+ <enumeration>CEC 2008-9</enumeration>
903
+ <enumeration>CEC 2008-10</enumeration>
904
+ </enumerations>
905
+ <row>456</row>
906
+ </term>
907
+ <term>
908
+ <name>Film Coefficients</name>
909
+ <data_type>enum</data_type>
910
+ <enumerations>
911
+ <enumeration>Yes</enumeration>
912
+ <enumeration>No</enumeration>
913
+ </enumerations>
914
+ <row>495</row>
915
+ </term>
916
+ <term>
917
+ <name>Resistance</name>
918
+ <description>Thermal resistance of material layer at a mean temperature of 75&#176;F under dry conditions; no film coefficients included.</description>
919
+ <data_type>double</data_type>
920
+ <ip_written>Hours Square Feet Degrees Rankine per British Thermal Unit</ip_written>
921
+ <ip_symbol>hr*ft^2*R/Btu</ip_symbol>
922
+ <si_written>Square Meters Degree Kelvin per Watt</si_written>
923
+ <si_symbol>m^2*K/W</si_symbol>
924
+ <row>496</row>
925
+ <unit_conversion>IP = 5.678263 * SI</unit_conversion>
926
+ </term>
927
+ <term>
928
+ <name>Construction Type</name>
929
+ <data_type>enum</data_type>
930
+ <enumerations>
931
+ <enumeration>Attic and Other</enumeration>
932
+ </enumerations>
933
+ <row>501</row>
934
+ </term>
935
+ <term>
936
+ <name>Insulation Minimum R-Value (ft^2*F*hr/Btu)</name>
937
+ <abbr>Insulation Minimum Thermal Resistance</abbr>
938
+ <description>R-13 + R-7.5 ci or R-5.7 ci</description>
939
+ <data_type>string</data_type>
940
+ <row>502</row>
941
+ </term>
942
+ </level_3>
943
+ <level_3>
944
+ <name>Exterior Roof</name>
945
+ <description/>
946
+ <term>
947
+ <name>OpenStudio Type</name>
948
+ <description>Type of OpenStudio Object</description>
949
+ <row>0</row>
950
+ </term>
951
+ <term>
952
+ <name>Standard</name>
953
+ <data_type>enum</data_type>
954
+ <enumerations>
955
+ <enumeration>ASHRAE 90.1-2001</enumeration>
956
+ <enumeration>ASHRAE 90.1-2004</enumeration>
957
+ <enumeration>ASHRAE 90.1-2007</enumeration>
958
+ <enumeration>ASHRAE 90.1-2010</enumeration>
959
+ <enumeration>ASHRAE 90.1-2013</enumeration>
960
+ <enumeration>ASHRAE 189.1-2009</enumeration>
961
+ <enumeration>ASHRAE 189.1-2011</enumeration>
962
+ <enumeration>ASHRAE 50% AEDG Large Hospital</enumeration>
963
+ <enumeration>ASHRAE 50% AEDG Medium to Big Box Retail</enumeration>
964
+ <enumeration>ASHRAE 50% AEDG Small to Medium Office</enumeration>
965
+ <enumeration>ASHRAE 50% AEDG K-12 School</enumeration>
966
+ <enumeration>ASHRAE 30% AEDG Small Office</enumeration>
967
+ <enumeration>ASHRAE 30% AEDG Small Retail</enumeration>
968
+ <enumeration>ASHRAE 30% AEDG K-12 School</enumeration>
969
+ <enumeration>ASHRAE 30% AEDG Small Warehouse and Self-Storage</enumeration>
970
+ <enumeration>ASHRAE 30% AEDG Highway Lodging</enumeration>
971
+ <enumeration>ASHRAE 30% AEDG Small Hospital and Healthcare</enumeration>
972
+ <enumeration>CEC Title 24-2005</enumeration>
973
+ <enumeration>CEC Title 24-2008</enumeration>
974
+ <enumeration>CEC Title 24-2013</enumeration>
975
+ </enumerations>
976
+ <row>454</row>
977
+ </term>
978
+ <term>
979
+ <name>Standard Type</name>
980
+ <data_type>enum</data_type>
981
+ <enumerations>
982
+ <enumeration>Residential</enumeration>
983
+ <enumeration>Nonresidential</enumeration>
984
+ </enumerations>
985
+ <row>455</row>
986
+ </term>
987
+ <term>
988
+ <name>Climate Zone</name>
989
+ <data_type>enum</data_type>
990
+ <enumerations>
991
+ <enumeration>ASHRAE 169-2006-1A</enumeration>
992
+ <enumeration>ASHRAE 169-2006-1B</enumeration>
993
+ <enumeration>ASHRAE 169-2006-2A</enumeration>
994
+ <enumeration>ASHRAE 169-2006-2B</enumeration>
995
+ <enumeration>ASHRAE 169-2006-3A</enumeration>
996
+ <enumeration>ASHRAE 169-2006-3B</enumeration>
997
+ <enumeration>ASHRAE 169-2006-3C</enumeration>
998
+ <enumeration>ASHRAE 169-2006-4A</enumeration>
999
+ <enumeration>ASHRAE 169-2006-4B</enumeration>
1000
+ <enumeration>ASHRAE 169-2006-4C</enumeration>
1001
+ <enumeration>ASHRAE 169-2006-5A</enumeration>
1002
+ <enumeration>ASHRAE 169-2006-5B</enumeration>
1003
+ <enumeration>ASHRAE 169-2006-5C</enumeration>
1004
+ <enumeration>ASHRAE 169-2006-6A</enumeration>
1005
+ <enumeration>ASHRAE 169-2006-6B</enumeration>
1006
+ <enumeration>ASHRAE 169-2006-7A</enumeration>
1007
+ <enumeration>ASHRAE 169-2006-7B</enumeration>
1008
+ <enumeration>ASHRAE 169-2006-8A</enumeration>
1009
+ <enumeration>ASHRAE 169-2006-8B</enumeration>
1010
+ <enumeration>CEC 2005-1</enumeration>
1011
+ <enumeration>CEC 2005-2</enumeration>
1012
+ <enumeration>CEC 2005-3</enumeration>
1013
+ <enumeration>CEC 2005-4</enumeration>
1014
+ <enumeration>CEC 2005-5</enumeration>
1015
+ <enumeration>CEC 2005-6</enumeration>
1016
+ <enumeration>CEC 2005-7</enumeration>
1017
+ <enumeration>CEC 2005-8</enumeration>
1018
+ <enumeration>CEC 2005-9</enumeration>
1019
+ <enumeration>CEC 2005-10</enumeration>
1020
+ <enumeration>CEC 2008-1</enumeration>
1021
+ <enumeration>CEC 2008-2</enumeration>
1022
+ <enumeration>CEC 2008-3</enumeration>
1023
+ <enumeration>CEC 2008-4</enumeration>
1024
+ <enumeration>CEC 2008-5</enumeration>
1025
+ <enumeration>CEC 2008-6</enumeration>
1026
+ <enumeration>CEC 2008-7</enumeration>
1027
+ <enumeration>CEC 2008-8</enumeration>
1028
+ <enumeration>CEC 2008-9</enumeration>
1029
+ <enumeration>CEC 2008-10</enumeration>
1030
+ </enumerations>
1031
+ <row>456</row>
1032
+ </term>
1033
+ <term>
1034
+ <name>Film Coefficients</name>
1035
+ <data_type>enum</data_type>
1036
+ <enumerations>
1037
+ <enumeration>Yes</enumeration>
1038
+ <enumeration>No</enumeration>
1039
+ </enumerations>
1040
+ <row>495</row>
1041
+ </term>
1042
+ <term>
1043
+ <name>Resistance</name>
1044
+ <description>Thermal resistance of material layer at a mean temperature of 75&#176;F under dry conditions; no film coefficients included.</description>
1045
+ <data_type>double</data_type>
1046
+ <ip_written>Hours Square Feet Degrees Rankine per British Thermal Unit</ip_written>
1047
+ <ip_symbol>hr*ft^2*R/Btu</ip_symbol>
1048
+ <si_written>Square Meters Degree Kelvin per Watt</si_written>
1049
+ <si_symbol>m^2*K/W</si_symbol>
1050
+ <row>496</row>
1051
+ <unit_conversion>IP = 5.678263 * SI</unit_conversion>
1052
+ </term>
1053
+ <term>
1054
+ <name>Construction Type</name>
1055
+ <data_type>enum</data_type>
1056
+ <enumerations>
1057
+ <enumeration>Metal Building</enumeration>
1058
+ <enumeration>Insulation Entirely Above Deck</enumeration>
1059
+ </enumerations>
1060
+ <row>498</row>
1061
+ </term>
1062
+ <term>
1063
+ <name>Insulation Minimum R-Value (ft^2*F*hr/Btu)</name>
1064
+ <abbr>Insulation Minimum Thermal Resistance</abbr>
1065
+ <description>R-13 + R-7.5 ci or R-5.7 ci</description>
1066
+ <data_type>string</data_type>
1067
+ <row>499</row>
1068
+ </term>
1069
+ </level_3>
1070
+ </level_2>
1071
+ <level_2>
1072
+ <name>Wall</name>
1073
+ <description/>
1074
+ <level_3>
1075
+ <name>Exterior Wall</name>
1076
+ <description/>
1077
+ <term>
1078
+ <name>OpenStudio Type</name>
1079
+ <description>Type of OpenStudio Object</description>
1080
+ <row>0</row>
1081
+ </term>
1082
+ <term>
1083
+ <name>Standard</name>
1084
+ <data_type>enum</data_type>
1085
+ <enumerations>
1086
+ <enumeration>ASHRAE 90.1-2001</enumeration>
1087
+ <enumeration>ASHRAE 90.1-2004</enumeration>
1088
+ <enumeration>ASHRAE 90.1-2007</enumeration>
1089
+ <enumeration>ASHRAE 90.1-2010</enumeration>
1090
+ <enumeration>ASHRAE 90.1-2013</enumeration>
1091
+ <enumeration>ASHRAE 189.1-2009</enumeration>
1092
+ <enumeration>ASHRAE 189.1-2011</enumeration>
1093
+ <enumeration>ASHRAE 50% AEDG Large Hospital</enumeration>
1094
+ <enumeration>ASHRAE 50% AEDG Medium to Big Box Retail</enumeration>
1095
+ <enumeration>ASHRAE 50% AEDG Small to Medium Office</enumeration>
1096
+ <enumeration>ASHRAE 50% AEDG K-12 School</enumeration>
1097
+ <enumeration>ASHRAE 30% AEDG Small Office</enumeration>
1098
+ <enumeration>ASHRAE 30% AEDG Small Retail</enumeration>
1099
+ <enumeration>ASHRAE 30% AEDG K-12 School</enumeration>
1100
+ <enumeration>ASHRAE 30% AEDG Small Warehouse and Self-Storage</enumeration>
1101
+ <enumeration>ASHRAE 30% AEDG Highway Lodging</enumeration>
1102
+ <enumeration>ASHRAE 30% AEDG Small Hospital and Healthcare</enumeration>
1103
+ <enumeration>CEC Title 24-2005</enumeration>
1104
+ <enumeration>CEC Title 24-2008</enumeration>
1105
+ <enumeration>CEC Title 24-2013</enumeration>
1106
+ </enumerations>
1107
+ <row>454</row>
1108
+ </term>
1109
+ <term>
1110
+ <name>Standard Type</name>
1111
+ <data_type>enum</data_type>
1112
+ <enumerations>
1113
+ <enumeration>Residential</enumeration>
1114
+ <enumeration>Nonresidential</enumeration>
1115
+ </enumerations>
1116
+ <row>455</row>
1117
+ </term>
1118
+ <term>
1119
+ <name>Climate Zone</name>
1120
+ <data_type>enum</data_type>
1121
+ <enumerations>
1122
+ <enumeration>ASHRAE 169-2006-1A</enumeration>
1123
+ <enumeration>ASHRAE 169-2006-1B</enumeration>
1124
+ <enumeration>ASHRAE 169-2006-2A</enumeration>
1125
+ <enumeration>ASHRAE 169-2006-2B</enumeration>
1126
+ <enumeration>ASHRAE 169-2006-3A</enumeration>
1127
+ <enumeration>ASHRAE 169-2006-3B</enumeration>
1128
+ <enumeration>ASHRAE 169-2006-3C</enumeration>
1129
+ <enumeration>ASHRAE 169-2006-4A</enumeration>
1130
+ <enumeration>ASHRAE 169-2006-4B</enumeration>
1131
+ <enumeration>ASHRAE 169-2006-4C</enumeration>
1132
+ <enumeration>ASHRAE 169-2006-5A</enumeration>
1133
+ <enumeration>ASHRAE 169-2006-5B</enumeration>
1134
+ <enumeration>ASHRAE 169-2006-5C</enumeration>
1135
+ <enumeration>ASHRAE 169-2006-6A</enumeration>
1136
+ <enumeration>ASHRAE 169-2006-6B</enumeration>
1137
+ <enumeration>ASHRAE 169-2006-7A</enumeration>
1138
+ <enumeration>ASHRAE 169-2006-7B</enumeration>
1139
+ <enumeration>ASHRAE 169-2006-8A</enumeration>
1140
+ <enumeration>ASHRAE 169-2006-8B</enumeration>
1141
+ <enumeration>CEC 2005-1</enumeration>
1142
+ <enumeration>CEC 2005-2</enumeration>
1143
+ <enumeration>CEC 2005-3</enumeration>
1144
+ <enumeration>CEC 2005-4</enumeration>
1145
+ <enumeration>CEC 2005-5</enumeration>
1146
+ <enumeration>CEC 2005-6</enumeration>
1147
+ <enumeration>CEC 2005-7</enumeration>
1148
+ <enumeration>CEC 2005-8</enumeration>
1149
+ <enumeration>CEC 2005-9</enumeration>
1150
+ <enumeration>CEC 2005-10</enumeration>
1151
+ <enumeration>CEC 2008-1</enumeration>
1152
+ <enumeration>CEC 2008-2</enumeration>
1153
+ <enumeration>CEC 2008-3</enumeration>
1154
+ <enumeration>CEC 2008-4</enumeration>
1155
+ <enumeration>CEC 2008-5</enumeration>
1156
+ <enumeration>CEC 2008-6</enumeration>
1157
+ <enumeration>CEC 2008-7</enumeration>
1158
+ <enumeration>CEC 2008-8</enumeration>
1159
+ <enumeration>CEC 2008-9</enumeration>
1160
+ <enumeration>CEC 2008-10</enumeration>
1161
+ </enumerations>
1162
+ <row>456</row>
1163
+ </term>
1164
+ <term>
1165
+ <name>Film Coefficients</name>
1166
+ <data_type>enum</data_type>
1167
+ <enumerations>
1168
+ <enumeration>No enum found</enumeration>
1169
+ </enumerations>
1170
+ <row>476</row>
1171
+ </term>
1172
+ <term>
1173
+ <name>Resistance</name>
1174
+ <description>Thermal resistance of material layer at a mean temperature of 75&#176;F under dry conditions; no film coefficients included.</description>
1175
+ <data_type>double</data_type>
1176
+ <ip_written>Hours Square Feet Degrees Rankine per British Thermal Unit</ip_written>
1177
+ <ip_symbol>hr*ft^2*R/Btu</ip_symbol>
1178
+ <si_written>Square Meters Degree Kelvin per Watt</si_written>
1179
+ <si_symbol>m^2*K/W</si_symbol>
1180
+ <row>477</row>
1181
+ <unit_conversion>IP = 5.678263 * SI</unit_conversion>
1182
+ </term>
1183
+ <term>
1184
+ <name>Construction Type</name>
1185
+ <data_type>enum</data_type>
1186
+ <enumerations>
1187
+ <enumeration>Metal Building</enumeration>
1188
+ <enumeration>Mass</enumeration>
1189
+ <enumeration>Wood-Framed and Other</enumeration>
1190
+ <enumeration>Steel-Framed</enumeration>
1191
+ </enumerations>
1192
+ <row>479</row>
1193
+ </term>
1194
+ <term>
1195
+ <name>Insulation Minimum R-Value (ft^2*F*hr/Btu)</name>
1196
+ <abbr>Insulation Minimum Thermal Resistance</abbr>
1197
+ <description>R-13 + R-7.5 ci or R-5.7 ci</description>
1198
+ <data_type>string</data_type>
1199
+ <row>480</row>
1200
+ </term>
1201
+ </level_3>
1202
+ <level_3>
1203
+ <name>Interior Wall</name>
1204
+ <description/>
1205
+ <term>
1206
+ <name>OpenStudio Type</name>
1207
+ <description>Type of OpenStudio Object</description>
1208
+ <row>0</row>
1209
+ </term>
1210
+ <term>
1211
+ <name>Standard</name>
1212
+ <data_type>enum</data_type>
1213
+ <enumerations>
1214
+ <enumeration>ASHRAE 90.1-2001</enumeration>
1215
+ <enumeration>ASHRAE 90.1-2004</enumeration>
1216
+ <enumeration>ASHRAE 90.1-2007</enumeration>
1217
+ <enumeration>ASHRAE 90.1-2010</enumeration>
1218
+ <enumeration>ASHRAE 90.1-2013</enumeration>
1219
+ <enumeration>ASHRAE 189.1-2009</enumeration>
1220
+ <enumeration>ASHRAE 189.1-2011</enumeration>
1221
+ <enumeration>ASHRAE 50% AEDG Large Hospital</enumeration>
1222
+ <enumeration>ASHRAE 50% AEDG Medium to Big Box Retail</enumeration>
1223
+ <enumeration>ASHRAE 50% AEDG Small to Medium Office</enumeration>
1224
+ <enumeration>ASHRAE 50% AEDG K-12 School</enumeration>
1225
+ <enumeration>ASHRAE 30% AEDG Small Office</enumeration>
1226
+ <enumeration>ASHRAE 30% AEDG Small Retail</enumeration>
1227
+ <enumeration>ASHRAE 30% AEDG K-12 School</enumeration>
1228
+ <enumeration>ASHRAE 30% AEDG Small Warehouse and Self-Storage</enumeration>
1229
+ <enumeration>ASHRAE 30% AEDG Highway Lodging</enumeration>
1230
+ <enumeration>ASHRAE 30% AEDG Small Hospital and Healthcare</enumeration>
1231
+ <enumeration>CEC Title 24-2005</enumeration>
1232
+ <enumeration>CEC Title 24-2008</enumeration>
1233
+ <enumeration>CEC Title 24-2013</enumeration>
1234
+ </enumerations>
1235
+ <row>454</row>
1236
+ </term>
1237
+ <term>
1238
+ <name>Standard Type</name>
1239
+ <data_type>enum</data_type>
1240
+ <enumerations>
1241
+ <enumeration>Residential</enumeration>
1242
+ <enumeration>Nonresidential</enumeration>
1243
+ </enumerations>
1244
+ <row>455</row>
1245
+ </term>
1246
+ <term>
1247
+ <name>Climate Zone</name>
1248
+ <data_type>enum</data_type>
1249
+ <enumerations>
1250
+ <enumeration>ASHRAE 169-2006-1A</enumeration>
1251
+ <enumeration>ASHRAE 169-2006-1B</enumeration>
1252
+ <enumeration>ASHRAE 169-2006-2A</enumeration>
1253
+ <enumeration>ASHRAE 169-2006-2B</enumeration>
1254
+ <enumeration>ASHRAE 169-2006-3A</enumeration>
1255
+ <enumeration>ASHRAE 169-2006-3B</enumeration>
1256
+ <enumeration>ASHRAE 169-2006-3C</enumeration>
1257
+ <enumeration>ASHRAE 169-2006-4A</enumeration>
1258
+ <enumeration>ASHRAE 169-2006-4B</enumeration>
1259
+ <enumeration>ASHRAE 169-2006-4C</enumeration>
1260
+ <enumeration>ASHRAE 169-2006-5A</enumeration>
1261
+ <enumeration>ASHRAE 169-2006-5B</enumeration>
1262
+ <enumeration>ASHRAE 169-2006-5C</enumeration>
1263
+ <enumeration>ASHRAE 169-2006-6A</enumeration>
1264
+ <enumeration>ASHRAE 169-2006-6B</enumeration>
1265
+ <enumeration>ASHRAE 169-2006-7A</enumeration>
1266
+ <enumeration>ASHRAE 169-2006-7B</enumeration>
1267
+ <enumeration>ASHRAE 169-2006-8A</enumeration>
1268
+ <enumeration>ASHRAE 169-2006-8B</enumeration>
1269
+ <enumeration>CEC 2005-1</enumeration>
1270
+ <enumeration>CEC 2005-2</enumeration>
1271
+ <enumeration>CEC 2005-3</enumeration>
1272
+ <enumeration>CEC 2005-4</enumeration>
1273
+ <enumeration>CEC 2005-5</enumeration>
1274
+ <enumeration>CEC 2005-6</enumeration>
1275
+ <enumeration>CEC 2005-7</enumeration>
1276
+ <enumeration>CEC 2005-8</enumeration>
1277
+ <enumeration>CEC 2005-9</enumeration>
1278
+ <enumeration>CEC 2005-10</enumeration>
1279
+ <enumeration>CEC 2008-1</enumeration>
1280
+ <enumeration>CEC 2008-2</enumeration>
1281
+ <enumeration>CEC 2008-3</enumeration>
1282
+ <enumeration>CEC 2008-4</enumeration>
1283
+ <enumeration>CEC 2008-5</enumeration>
1284
+ <enumeration>CEC 2008-6</enumeration>
1285
+ <enumeration>CEC 2008-7</enumeration>
1286
+ <enumeration>CEC 2008-8</enumeration>
1287
+ <enumeration>CEC 2008-9</enumeration>
1288
+ <enumeration>CEC 2008-10</enumeration>
1289
+ </enumerations>
1290
+ <row>456</row>
1291
+ </term>
1292
+ <term>
1293
+ <name>Film Coefficients</name>
1294
+ <data_type>enum</data_type>
1295
+ <enumerations>
1296
+ <enumeration>No enum found</enumeration>
1297
+ </enumerations>
1298
+ <row>476</row>
1299
+ </term>
1300
+ <term>
1301
+ <name>Resistance</name>
1302
+ <description>Thermal resistance of material layer at a mean temperature of 75&#176;F under dry conditions; no film coefficients included.</description>
1303
+ <data_type>double</data_type>
1304
+ <ip_written>Hours Square Feet Degrees Rankine per British Thermal Unit</ip_written>
1305
+ <ip_symbol>hr*ft^2*R/Btu</ip_symbol>
1306
+ <si_written>Square Meters Degree Kelvin per Watt</si_written>
1307
+ <si_symbol>m^2*K/W</si_symbol>
1308
+ <row>477</row>
1309
+ <unit_conversion>IP = 5.678263 * SI</unit_conversion>
1310
+ </term>
1311
+ <term>
1312
+ <name>Construction Type</name>
1313
+ <data_type>enum</data_type>
1314
+ <enumerations>
1315
+ <enumeration>Standard</enumeration>
1316
+ </enumerations>
1317
+ <row>482</row>
1318
+ </term>
52
1319
  </level_3>
53
1320
  </level_2>
54
1321
  </level_1>
@@ -3786,8 +5053,7 @@ Example: Product family X uses product numbers that contain eight alphanumeric
3786
5053
  <data_type>enum</data_type>
3787
5054
  <allow_multiple>false</allow_multiple>
3788
5055
  <enumerations>
3789
- <enumeration>Yes</enumeration>
3790
- <enumeration>No</enumeration>
5056
+ <enumeration>No enum found</enumeration>
3791
5057
  </enumerations>
3792
5058
  <row>197</row>
3793
5059
  <tp_include>true</tp_include>
data/lib/bcl/version.rb CHANGED
@@ -18,5 +18,5 @@
18
18
  ######################################################################
19
19
 
20
20
  module BCL
21
- VERSION = "0.2.9"
21
+ VERSION = "0.3.0"
22
22
  end
metadata CHANGED
@@ -1,13 +1,13 @@
1
1
  --- !ruby/object:Gem::Specification
2
2
  name: bcl
3
3
  version: !ruby/object:Gem::Version
4
- hash: 5
4
+ hash: 19
5
5
  prerelease:
6
6
  segments:
7
7
  - 0
8
- - 2
9
- - 9
10
- version: 0.2.9
8
+ - 3
9
+ - 0
10
+ version: 0.3.0
11
11
  platform: ruby
12
12
  authors:
13
13
  - Daniel Macumber
@@ -18,7 +18,7 @@ autorequire:
18
18
  bindir: bin
19
19
  cert_chain: []
20
20
 
21
- date: 2013-09-03 00:00:00 Z
21
+ date: 2013-09-04 00:00:00 Z
22
22
  dependencies:
23
23
  - !ruby/object:Gem::Dependency
24
24
  name: uuid